Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of OD600-F4-8BPV Optical data coupler

Spec sheet · Pepperl+Fuchs

OD600-F4-8BPV Optical data coupler

Spec sheet6 pagesPDF 109 KB

Data sheet for the Pepperl+Fuchs OD600-F4-8BPV optical data coupler, an 8-channel bidirectional infrared data link.

Download the PDF109 KB

Covers · 1 model

The models it covers

Summary

What is in it

The Pepperl+Fuchs data sheet for the OD600-F4-8BPV optical data coupler, which transfers 8 channels of data in both directions over a light beam, with a control output for correct data transfer and a stop input. It lists general, electrical, ambient and mechanical specifications, the response curve and dimensions, the cable color assignment for inputs and outputs, the operating mode switch, LED indicators and the time response.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Data sheet for the Pepperl+Fuchs OD600-F4-8BPV optical data coupler, which passes eight data channels in both directions over an IR beam. It gives the technical data, dimensions, wire colors, the stop and mode inputs, the indicators and the timing.

Device
Optical data coupler, 8-channel data transfer in both directions p. 1
Operating voltage
10 ... 30 V DC, 5 % ripple p. 2
Transfer
FSK transmission, transfer time ≤ 40 ms p. 2
Outputs
UB-2.5 V, 30 mA max., short circuit-proof p. 5
Inputs
35 V max., 8 mA max. p. 5
Connection
2000 mm PVC cable p. 2
Supply wires
+UB pink/black, 0V light blue p. 4
Data wires
Input 1 brown to input 8 gray; output 1 brown/black to output 8 gray/black; stop input white p. 5
Protection degree
IP66 p. 2
Ambient temperature
-10 ... 50 °C p. 2
Light spot
300 mm at a distance of 600 mm, ± 15 ° divergence p. 2
Indicators
16 data flow LEDs, plus Power, RCV and GO LEDs p. 2, 6
Mass
80 g (240 g with 2000 mm cable) p. 2
Ambient light limit
40000 Lux p. 2

What this sheet walks you through

  • Wiring the supply, data inputs and outputs by conductor color p. 4, 5
  • Setting the unit to transmit or receive when idle p. 5
  • Reading the Power, RCV and GO LEDs p. 6
  • Data transfer timing p. 6
  • Mounting dimensions p. 3

Good to know

  • Switching the stop input to +UB disables both transmitting and receiving. p. 5
  • Data must be held at an input for at least 30 ms. p. 6
  • A NAMUR proximity switch can be connected only at UB above 20.4 V. p. 5

Questions this sheet answers

What supply voltage does the OD600-F4-8BPV need?

10 to 30 V DC, with 5 % ripple. p. 2

How many channels does the OD600-F4-8BPV transfer?

Eight, in both directions. p. 1

How do I set the OD600 to transmit or receive?

Jumpering the pink mode input to +UB makes it ready for transmission; without the jumper it is ready for reception. p. 5

What does the GO LED on the OD600 mean?

It shows the control output, which switches to +UB when the data transmission route works without errors. p. 5, 6

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6

The file

Revision and size

RevisionDate of issue: 2007-06-18, 021535_ENG
PublisherPepperl+Fuchs
Pages6
PDF109 KB
TextText from the PDF itself.

The first pages · 4 of 6

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 6
Page 2
Page 2of 6
Page 3
Page 3of 6
Page 4
Page 4of 6