Spec sheet · Pepperl+Fuchs
OD600-F4-8BPV Optical data coupler
Spec sheet6 pagesPDF 109 KB
Data sheet for the Pepperl+Fuchs OD600-F4-8BPV optical data coupler, an 8-channel bidirectional infrared data link.
Covers · 1 model
The models it covers
Summary
What is in it
The Pepperl+Fuchs data sheet for the OD600-F4-8BPV optical data coupler, which transfers 8 channels of data in both directions over a light beam, with a control output for correct data transfer and a stop input. It lists general, electrical, ambient and mechanical specifications, the response curve and dimensions, the cable color assignment for inputs and outputs, the operating mode switch, LED indicators and the time response.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Data sheet for the Pepperl+Fuchs OD600-F4-8BPV optical data coupler, which passes eight data channels in both directions over an IR beam. It gives the technical data, dimensions, wire colors, the stop and mode inputs, the indicators and the timing.
- Device
- Optical data coupler, 8-channel data transfer in both directions p. 1
- Operating voltage
- 10 ... 30 V DC, 5 % ripple p. 2
- Transfer
- FSK transmission, transfer time ≤ 40 ms p. 2
- Outputs
- UB-2.5 V, 30 mA max., short circuit-proof p. 5
- Inputs
- 35 V max., 8 mA max. p. 5
- Connection
- 2000 mm PVC cable p. 2
- Supply wires
- +UB pink/black, 0V light blue p. 4
- Data wires
- Input 1 brown to input 8 gray; output 1 brown/black to output 8 gray/black; stop input white p. 5
- Protection degree
- IP66 p. 2
- Ambient temperature
- -10 ... 50 °C p. 2
- Light spot
- 300 mm at a distance of 600 mm, ± 15 ° divergence p. 2
- Indicators
- 16 data flow LEDs, plus Power, RCV and GO LEDs p. 2, 6
- Mass
- 80 g (240 g with 2000 mm cable) p. 2
- Ambient light limit
- 40000 Lux p. 2
What this sheet walks you through
- Wiring the supply, data inputs and outputs by conductor color p. 4, 5
- Setting the unit to transmit or receive when idle p. 5
- Reading the Power, RCV and GO LEDs p. 6
- Data transfer timing p. 6
- Mounting dimensions p. 3
Good to know
- Switching the stop input to +UB disables both transmitting and receiving. p. 5
- Data must be held at an input for at least 30 ms. p. 6
- A NAMUR proximity switch can be connected only at UB above 20.4 V. p. 5
Questions this sheet answers
What supply voltage does the OD600-F4-8BPV need?
10 to 30 V DC, with 5 % ripple. p. 2
How many channels does the OD600-F4-8BPV transfer?
Eight, in both directions. p. 1
How do I set the OD600 to transmit or receive?
Jumpering the pink mode input to +UB makes it ready for transmission; without the jumper it is ready for reception. p. 5