The text of a spec sheet · part 1 of 1
OD600-F4-8BPV Optical data coupler, pages 1 to 6
Pages 1 to 6 of 6
The original document is the PDF (109 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Pepperl+Fuchs OD600-F4-8BPV
Page 1
OD600-F4-8BPV
Optical data coupler
OD600-F4-8BPV Detection range up to 3000 mm
! 8-channel data transfer in both directions ! Control output for correct data transfer ! Stop input ! Large sensing range
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml
! Large offset angle
Subject to reasonable modifications due to technical advances.
1
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Page 2
Technical data
OD600-F4-8BPV
General specifications Effective detection range
0 ... 600 mm
Approvals
CE
Alignment aid
1 LED
Transmission mode
FSK
Transfer time
≤ 40 ms
Diameter of the light spot
300 mm at a distance of 600 mm
Angle of divergence
± 15 °
Ambient light limit
40000 Lux
Indicators/operating means Data flow display
16 LEDs for signaling the switch states of the in and outputs
Function display
1 LED for operating voltage 1 LED for correct data transfer
Electrical specifications Operating voltage
10 ... 30 V DC
Ripple
5 %
No-load supply current I0
≤ 80
Output Voltage drop Switching frequency
Ud
≤ 2.5 V f
12 Hz
Standard conformity Standards
EN 60947-5-2
Ambient conditions Ambient temperature
-10 ... 50 °C (263 ... 323 K)
Storage temperature
-20 ... 70 °C (253 ... 343 K)
Mechanical specifications Protection degree
IP66
Connection
2000 mm PVC cable
Material 80 g (240 g with 2000 mm cable)
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml
Mass
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
2
Page 3
OD600-F4-8BPV Curves/Diagrams Characteristic response curve Offset Y [m] 0.4 0.3 0.2 0.1 0 0.1 0.2 0.3 0.4 0
0.2
0.4
0.6
0.8
1.0 1.2 Distance X [m] y x
Dimensions
Mounting holes 2 x ø 4.5
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
70
1
20
10
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml
Center of the optical axis
80
Sensitivity adjuster
30 60
Subject to reasonable modifications due to technical advances.
3
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Page 4
OD600-F4-8BPV Electrical connection
Light blue
0V
Pink/black
+UB
Light blue/black White/black Gray/black Violet/black Blue/black Green/black Yellow/black Orange/black Red/black Brown/black
Gray Violet Blue Green Yellow Orange Red Brown White
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml
Pink
-UB control output D8OUT D7OUT D6OUT D5OUT D4OUT D3OUT D2OUT D1OUT
D8IN D7IN D6IN D5IN D4IN D3IN D2IN D1IN stop input operating mode o = light ON, • = dark ON
Function Assignment of the connections Supply voltage + Supply voltage Ground connection
Pink/Black Light blue/Black Light blue
For inputs and outputs:
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
4
Page 5
OD600-F4-8BPV Input
Conductor color
Output
Conductor color
1
Brown
1
Brown/Black
2
Red
2
Red/Black
3
Orange
3
Orange/Black
4
Yellow
4
Yellow/Black
5
Green
5
Green/Black
6
Blue
6
Blue/Black
7
Violet
7
Violet/Black
8
Gray
8
Gray/Black
Stop input
White
Stop input If this input is switched to +UB, the data transfer (transmitting and receiving) is disabled.
Switch of operating mode (Pink) This input is used to switch to ready for reception or transmission in idle mode. Jumpering this input with +UB causes the data transmission light beam switch to be ready for transmission, without the jumper it is ready for reception Ready for transmission means that as soon as it makes contact with another data transmission light beam switch, this data transmission light beam switch will first start to transmit its data and will then switch to reception. Ready for reception means that the data transmission light beam switch will wait in idle mode for transmitted data from another data transmission light beam switch, that it will immediately switch the data to the outputs when it is received, and that it will then switch to transmission.
Conntrol output (White/Black) This output is switched to +UB if the data transmission route works free of errors. The respective switching state is then indicated by the "GO" LED. Input switching Input voltage Input current
UI max = 35 V II max = 8 mA
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml
In accordance with DIN 19234 (NAMUR) a proximity switch can be connected at UB > 20.4 V.
Output switching Output voltage Operating current
UA= UB-2.5 V ILmax = 30 mA, short circuit-proof
Subject to reasonable modifications due to technical advances.
5
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Page 6
OD600-F4-8BPV Indicators „Power“ - LED operating voltage turned on.
„RCV“ - LED lights up if the optical radiation axes of the transmitter and receiver are within the permitted tolerance range (max. offset angle).
„GO“ - LED indicates the switching status of the control output.
Time response t1 = min. 30 ms The time for which data must be active at the INPUT t2 = max. 40 ms transfer time t3 = 90 ms The time between the interruption of the IR beam and the reset of the "GO" output and DATA-OUTPUT
Release date: 2007-06-18 14:54 Date of issue: 2007-06-18 021535_ENG.xml t4 = 110 ms The time between the establishment of the IR beam and the setting of the "GO" output and DATA-OUTPUT
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
6