AX4 Drive Application Manual, pages 11 to 20

Pages 11 to 20 of 37

The original document is the PDF (759 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Phase AX-4

Page 11

AX4 Drive

Application manual

Phase 1 1AX 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25.

MOTOR CURRENT ENCODER A ENC. C (& PROXY) TACHO ENABLE SPEED REF SIGNAL GND AUX +5 V READY SPEED REF + 10V REFERENCE CURRENT LIMIT AUX +24 V NC PROXIMITY BYPASS RAMP ALARM NC ALARM NO AUX 0V ALARM COM CURRENT SEL SIGNAL GND ENCODER B NC NC

Common mode inductance filter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

ENABLE

SPEED REF +

AUX 24V +

BYPASS RAMP AUX 0V

Connection table pag.14 - 15

CURRENT SEL. OFF = current ON = speed

1.1.3.2Moto r Sensor

ENC.

1.1.3.2.1 ND

1.1.3.1.1

11 .3 .U 5 .

1.1.3.4.1.1 Motor

11 .3 .V 3 . 11 .3 .W 4 .

1.1.3.6.1 ND Motor 1. Use shielded cable only, with shield coverage > 85 %

6 11 .3 .S .

2.

T BRBR+/DC+

Phase Motion Control S.r.l., Genova, Italy

AUX 24V +

LINE FILTER

S

Power cables longer than 20 meter may generate overvoltages on the motor and damage to the drives. Insert series inductance 1 H

R

1.1.3.7GROUND BAR 10

Suggested circuit for motor brake relay. Zener 50V 5W

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 12

AX4 Drive

Application manual

WARNING!! BEFORE CONNECTING EXTERNAL BRAKE DISCONNECT INTERNAL RESISTOR – LIVE CONTACTS

AUX 0V figure 4-B- Connection scheme for the speed reference with internal reference voltage and bidirectional functioning. The input selection relay has to be mounted as near as possible to the drive figure 4-C - Connection scheme for the speed reference with external reference signal (+/-10V f.s.)

figure 4-D - Connection scheme for the speed reference with external reference voltage and bidirectional operation

Phase Motion Control S.r.l., Genova, Italy

11

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 13

AX4 Drive

Application manual

TABLE 2.4-A COMMAND CONNECTOR - FUNCTIONALITY AND SIGNAL DESCRIPTION

N. Pin

Name

CONN. ON CARD - 25 PIN D-Type CANNON, REMOVABLE FEMALE Type Function Signal description

1

MOTOR CURRENT

Analog output

Instant indication of the motor current

The output signal refers to the Pin 7. The current can be obtained from the formula: Im = Ipk/9V. Output impedance: 10 kOhm

2

ENC A

Digital output

Channel A encoder (reversed)

Signal open collector 24V, 20mA. See note 2.

3

ENC C (& PROXY)

Digital output

Encoder index (logic AND between the Proximity input and zero encoder)

Signal open collector 24V, 20mA. See note 1 and 2.

4

TACHO

Analog output

Indication of motor speed

The output signal refers to the Pin 7. The speed can be obtained from the ratio: 850mV / 1000rpm Output impedance: 10 kOhm

5

ENABLE

Digital input

Drive enable

The drive is enabled for voltages from 14 to 30V compared to the Pin 7. Input impedance: 1 kOhm Disabling the drive the motor is free at any speed.

6

SPEED REF-

Analog input

Negative of reference +/10V input

If it is not used connect to the Pin 7. A positive voltage value corresponds to the clockwise rotation of the shaft seen from the torque side. Input impedance: 10 kOhm

7

SIGNAL GND

0V analog signals

8

AUX +5V

Auxiliary supply output

9

READY -

Digital output

NOR of protection logic output

Signal open collector 24V, 20mA. See note 2.

10

SPEED REF+

Analog input

Positive of reference +/10V input

If it is not used connect to the Pin 7. A positive voltage value corresponds to the anticlockwise rotation of the shaft seen from the torque side. Input impedance: 10 kOhm

11

10V ref

Analog output

Reference voltage

Stabilized voltage output. Max current: 5mA Regulation: +/-1%

12

CURRENT LIMIT

Analog input

Dynamic limitation of current/torque

It allows the variation of the current/torque limit via an analog input. Range: 0-10V = 0-100% If it is not connected the limit is 100%. The internal pull-up is 15V, 10 kOhm.

13

AUX +24V

Auxiliary supply

Aux supply for regulation circuits

Voltage: 24-30 V referred to Pin 19. Supply current: 600mA.

14

NC

Max current: 100mA Regulation: 0/+200 mV

Phase Motion Control S.r.l., Genova, Italy

12

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 14

AX4 Drive

Application manual

TABLE 5-1 COMMAND CONNECTOR - FUCTIONALITY AND SIGNAL DESCRIPTION N. Pin

CONN. ON CARD - 25 PIN FLOAT CHAMBER CANNON, EXTRACTABLE FEMALE Name Type Function Signal description

15

PROXIMITY

Digital input

Input for suppression of the encoder zeros

High signal for voltages from 14 to 30 V in comparison to the Pin 7. If it is not connected it is recalled to 0 internally. See note 1.

16

BYPASS RAMP

Digital input

Ramp clear

If enabled (voltages from 14 to 30 V in comparison to the Pin 7) it clears the ramp. Input impedance: 22 kOhm.

17

ALARM NC

Alarm relay

Normally closed contact

Contact isolated from power and signal. Max current: 1A Max voltage: 250V

18

ALARM NO

Alarm relay

Normally opened contact

Contact isolated from power and signal. Max current: 1A. Max voltage: 250V.

19

AUX 0V

0V auxiliary supply

Internally connected to the Pin 7. To be used only for the auxiliary supply.

20

ALARM COM

Alarm relay

Common on relay contacts

21

CURRENT SEL

Digital input

Regulation selection of current/speed

High: speed regulation. Low: current regulation. High signal for voltages from 14 to 30 V in comparison to the Pin 7. Input impedance: 10 kOhm

22

SIGNAL GND

23

ENC B

24

NC

25

NC

Digital output

Channel B denied encoder

Signal open collector 24V, 20mA. See note 2.

Note 1 - Using the circuit for the suppression of the encoder zeros When there is the presence of a simple mechanical transmission system, where the transmission ratio between the motor shaft and the activated axis is an integer, the signal of the motor encoder can be converted into a position signal of the activated axis. If R is the transmission ratio between the motor and the axis, in order to have the inidcation of the shaft position it is necessary to eliminate the R-1 zeros of the encoder signal. To this purpose it is sufficient to use a sensor with a low resolution (for example a proximity) which is able to supply a signal differnt from zero only in connection with the zero angular position of the activated axis. This function is enabled when the jumper S10 is taken away from the card. The proximity signal is taken by the Pin 15 of the Command Connector and the zero suppression circuit carries out a logic AND between the proximity signal and the encoder zeros. The operation result, equal to 1 in connection with the useful zero, is available on the Pin 3 of the Command Connector.

Note 2 - Open Collector Signal he drive is not provided with an internal pull-up resistance. If it is necessary use an external one connected to a potential not higher than 30 V.

Phase Motion Control S.r.l., Genova, Italy

13

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 15

AX4 Drive

Application manual

TABLE 2.4-B MOTOR SENSOR CONNECTOR: FUNCTIONALITY AND SIGNAL DESCRIPTION

Card Conn. Pin

CONN. ON CARD - 15 PIN D-Type CANNON, REMOVABLE MALE CONN. TO THE ULTRACT (*) MOTOR - TYPE IPT 06A-12-14S, MIL C 26482 Motor Terminal Name Type Function Signal Connect Block description or Pin

1

A

2

GND+PTC

0V

2

--

--

HALL 1N

Digital input

3

P

5

HALL 1

4

C

4

5

D

6

Digital input

Hall sensor phase 1 denied Hall sensor phase 1

Square wave 5V Square wave 5V

0-

HALL 2

Digital input

Hall sensor phase 2

Square wave 0-5V

11

HALL 3

Digital input

Hall sensor phase 3

Square wave 5V

0-

E

1

AUX +5V

Auxiliary supply

7

F

7

ENC A+

Digital input

Channel A encoder

Square wave 5V

0-

8

B

15

PTC

Digital input

Motor protection

9

H

9

ENC I-

Digital input

Denied encoder index

Square wave 5V

0-

10

--

--

HALL 2N

Digital input

--

--

HALL 3N

Digital input

12

J

8

ENC A-

Digital input

Square wave 5V Square wave 5V Square wave 5V

0-

11

Hall sensor phase 2 denied Hall sensor phase 3 denied Channel A denied encoder

13

K

13

ENC B-

Digital input

Channel encoder

Square wave 5V

0-

14

L

10

ENC I

Digital input

Encoder index

Square wave 5V

0-

15

M

14

ENC B

Digital input

Channel B encoder

Square wave 5V

0-

0- thermal

B denied

00-

(*) NOTE: As for motors different from the ULTRACT series, see figure 6-a.

Phase Motion Control S.r.l., Genova, Italy

14

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 16

AX4 Drive

Application manual

TABLE 2.4-C POWER CONNECTIONS MORS. ON CARD - PHOENIX PC4/10-ST 7.62 10 CONTACTS - REMOVABLE FEMALE CONN.TO THE ULTRACT MOTOR - MS/MIL C 5015 TYPE CVB 06A 22-22S Terminal

Description

ULTRACT Pin connector

Wire color in the ULTRACT motor

U

Motor phase U

B

Red

V

Motor phase V

A

Blue

W

Motor phase W

C

Yellow

R

Supply phase R

---

---

S

Supply phase S

---

---

T

Supply phase T

---

---

BR-

Resistance connection for external braking

---

---

Resistance connection for external braking

---

---

BR+

(Positive DC bus ) DC-

Negative DC bus

---

---

GND

Power circuit mass

D

Yellow-green

Phase Motion Control S.r.l., Genova, Italy

15

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 17

AX4 Drive

Application manual

5. EC norms and interference protection Brushless drives of the AX-4 series are components for PDS (Power Drive System), designed in accordance with the EMC 89/336/EEC and LVD 93/68/EEC norms and in particular with the EMC IEC-22G-21/CDV norm. They are specified for the application Fields 2,3. As Components the AX-4 drives comply with the IEC 1000-4-2 (IEC 801-2) and IEC 1000-4-4 (IEC 801-4), without any accessory or protection. The above mentioned IEC 22G norm specifies an electromagnetic interference limit for the active system and not for the component (it would not be possible in any case). As for applications similar to the reference one, the single or multi-axes coupling with the AX-S filtrated supply module, that is with the filter SHAFFNER FN351/25/33 or something equivalent, with up to 100 meters of shielded-conductor cable between the drive and the motor, allows the active system (PDS) to satisfy the requirements of the IEC-EN 55011 norm Class B, equivalent to the more urgent VDE 871 norms. If required, type test certificates are available. With these limits, the EC marking, even though it is not necessary, has been present on the AX4 series starting from 1.1.1996. Operative advice In order to minimize the electromagnetic interference, the signal cables have always to be shielded; the use of a shielded cable is suggested also for the power connections. As for the shields and ground connection see the figure 6-1. In order to reduce the interferences caused by the motor cable and the induced noises in the encoder connection cable, such cables have not to be longer than 20 meters. Such length is necessary also for the protection of the drive itself. It is important that the power wiloop is inserted in wireways different from the signal and supply one and that any cross between the power and signal cables is carried out at right angle. It is necessary to have always a mass cable between the motor and the drive, with a layout similar to the one belonging to the power cables. If the plant foresees the use of sensitive instruments (for example analog non preamplified transducers, load cells, thermocouples etc.) keep the maximum distance between the instrumentation ground and the power one. As the high voltage caused by the drive is partially coupled on the ground conductor, it is normal that a weak current with a high voltage crosses the conductor itself; because of this it could be impossible to use high sensitivity differential switches. For the same reason, the ground cable may represent a duct carrying the electromagnetic interference to the other parts of the plant; as a consequence, it is useful to remove the small signal cables from the ground cable even in the upper part of the drive. NOTE: as specified in the EMC IEC-22G-21/CDV norm, the AX4 drives are not destined to be used in a domestic environment and they may cause some interferences to the radio and television receptions.

Phase Motion Control S.r.l., Genova, Italy

16

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 18

AX4 Drive

Application manual figure 5-A - Ground connection diagram

Phase Motion Control S.r.l., Genova, Italy

17

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 19

AX4 Drive

Application manual

6. Commissioning 6.1 Encoder phasing IMPORTANT: The Ultract motors supplied for the use with AX4 drives are factory set and therefore the phasing has not to be carried out except after a possible replacement of the encoder. The following procedure has therefore to be used only in such a case or with the use of motors not belonging to the ULTRACT series. In order to allow a correct functioning of the drive it is necessary that the Hall effect encoder/sensors group mounted on the motor is located in a precise position consideloop the windings of the motor phases. Normally the encoder positioning, or phasing, is carried out with the motor construction and therefore no intervention is required to the user. Anyway, should this operation be necessary, act as follows: 1. Disengage the axis letting the motor free to rotate 2. Open the rear motor cap and loosen the screws of the encoder stator 3. Supply the drive both for power and signal and enable the drive without reference, with a current control. 4. Press the PHASE SET button and keep it pressed; the motor takes a direction and blocks itself. In this condition, if the encoder position is a wrong one, the two LD3-LD4 leds light up simultaneously 5. Rotate by hand the encoder body observing the LD3-LD4 leds till they change their condition simultaneously 6. Block the encoder screwing the screws with a 0.2-0.5 Nm clamping torque and depress the PHASE SET button 7. Close the rear cap screwing the screws with a 5 Nm torque We suggest to carry out the encoder phasing with the highest possible care. The max accepted error is 1 degree, equal to 0,5 mm on the encoder perimeter. NOTE 1:

Shold the phasing be impossible, that is the motor does not rotate uniformly in the current loop, control the sequence of the motor phases and of the Hall ducts as in figure 7-1.

NOTE 2: If, after the phasing, the motor operates regularly in the current loop but it presents a runaway effect in the speed loop, control the sequence of the encoder signals A,B and C as in figure 7-2.

Phase Motion Control S.r.l., Genova, Italy

18

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 20

AX4 Drive

Application manual figure 6-A - Motor phase sequence - Hall probes

Phase Motion Control S.r.l., Genova, Italy

19

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com