Manual · Phase

AX4 Drive Application Manual

Manual37 pagesPDF 759 KB

Application manual for the Phase Motion Control AX4 brushless servo motor drive series, covering installation, connections and tuning.

Download the PDF759 KB

Covers · 1 model

The models it covers

Summary

What is in it

The application manual for the Phase Motion Control AX4 series of IGBT drives for permanent magnet brushless servo motors (models AX5.7/11-2, AX12/16-2, AX04/08-3, AX8.5/14-3 and AX17/35-3). It gives technical, electrical, thermal, mechanical and environmental data, then covers mechanical installation, connections, EC norms and interference protection, commissioning with encoder phasing and tuning, LED diagnostics and alarm handling, and an application guide for choosing transmission, feedback and motor size.

Its parts

  1. In General
  2. Mechanical Installation
  3. Connections
  4. EC Norms and Interference Protection
  5. Commissioning
  6. Diagnostic
  7. Application Guide

From the manual

Key facts from this manual

Each line names its page in the PDF.

The Phase Motion Control application manual for the AX4 drive, a series of IGBT drives for permanent magnet brushless servo motors. It covers the AX5.7/11-2, AX12/16-2, AX04/08-3, AX8.5/14-3 and AX17/35-3 models. It gives the ratings, connector pinouts, mounting and EMC wiring, encoder phasing, loop tuning and the meaning of the alarm LEDs.

Read for this summary: pages 1 to 25 of 37.

Device
Drive for permanent magnet brushless servo motors, up to 100,000 rpm p. 4
Models
AX5.7/11-2, AX12/16-2, AX04/08-3, AX8.5/14-3, AX17/35-3 p. 2
Supply
Three-phase mains, 220-240 V or 380/440 V (+5% / -20%), 50-60 Hz, with or without neutral p. 4
Output current
380-440 V models: 4, 8.5 and 17 A nominal rms; rated peak current for 5 minutes, or indefinitely at up to 50% duty cycle p. 4
Control
Six step control, 16 kHz current modulation, 4 kHz current loop bandwidth p. 4
Feedback
Built-in optical motor encoder with 3 commutation channels; A, B and index C available on the control connector p. 4
Connectors
Command: 25-pin D-type female; motor sensor: 15-pin D-type male; power: Phoenix PC4/10-ST 7.62, 10 contacts p. 13, 15, 16
Alarm relay
NC and NO contacts with common (pins 17, 18, 20), isolated, max 1 A, 250 V p. 14
Enable input
Pin 5: enabled at 14 to 30 V relative to pin 7; motor runs free when disabled p. 13
Tacho output
Pin 4: 850mV / 1000rpm p. 13
Size and enclosure
85 x 225 x 341 mm or 182 x 225 x 341 mm (L x P x H) depending on model; IP20 p. 6
Environment
Operating 0 / +40 °C; storage -20 / +70 °C; 0 - 95% RH n.c.; derate current 5% per 100 m above 1000 m p. 6
Protections
Thermal overload, blocked axis, overvoltage, low supply, phase loss and short circuit, shown by LEDs; critical alarm drives a relay p. 4
Braking
Built-in braking module and dissipative element; an external resistor can be added for heavy braking p. 4

What this manual walks you through

  • Mounting the drive in a cabinet with the right clearances p. 7, 8
  • Choosing a wiring scheme for the speed reference p. 9, 12
  • Wiring the 25-pin command connector p. 13, 14
  • Wiring the motor sensor connector (encoder and Hall sensors) p. 15
  • Power terminals and Ultract motor connections p. 16
  • Shielding and grounding to limit interference p. 17, 18
  • Phasing the encoder after an encoder replacement p. 19
  • Tuning the speed loop with the trimmers p. 22
  • Reading the LEDs and clearing alarms p. 24, 25

Good to know

  • Motor and encoder cables should be no longer than 20 meters, to limit interference and protect the drive. p. 17
  • The drives are not meant for a domestic environment and may interfere with radio and television reception. p. 17
  • Disconnect the internal braking resistor before connecting an external one; the contacts are live. p. 12
  • Ultract motors come phased from the factory; phasing is needed only after an encoder replacement or with other motors, and the maximum error is 1 degree. p. 19
  • Install it in a dry place without vibration, conductive dust or steam. p. 7

Questions this manual answers

What supply voltage does the Phase AX4 drive use?

Three-phase mains at 220-240 V or 380/440 V (+5% / -20%), 50-60 Hz, with or without a neutral. p. 4

How do I reset a UV or OV alarm on the AX4 drive?

Switch the auxiliary supply off and on again. The alarm is stored but does not block the drive permanently. p. 24

What does the SH C LED mean on an AX4 drive?

A short circuit in the wiring or motor, or a ground fault on the motor side. Wrong encoder phasing, poor motor grounding, interference or overly long wiring can also trigger it. p. 25

What is the AX4 tacho output scale?

Pin 4 of the command connector gives 850mV per 1000rpm, referred to pin 7. p. 13

How do I move the settings to a replacement AX4 drive?

Move the removable personality card, which carries the tuning trimmers, to the new drive. p. 22

The whole text · 4 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 3731-37

The file

Revision and size

RevisionAXM1 - 2, 1/96
PublisherPhase Motion Control S.r.l.
Pages37
PDF759 KB
TextText from the PDF itself.