Page 31

AX4 Drive

Application manual

• with the maximum obtainable ratio with just one reduction torque; • with the maximum obtainable ratio with two reduction torques etc. The economic optimization, in this case, is carried out checking these points and adding the obtained costs of the motors to the ones of the reducers. On the contrary, as for the applications with a high dynamic (axes) the situation is completely different. If the torque required in the drive cycle is dominated by the inertial torque both of the motor and of the load, it is clear that increasing the reduction ratio there is a decrease of the importance of the load inertia and an increase of the motor one. It is possible to state, therefore, that, for an application where the torque given is exclusively inertial, the reduction ratio able to make the load inertia, compared to the motor axis, equal to the motor inertia (inertial coupling) is the one the minimum torque given corresponds to (as a consequence the motor is smaller). For this reason, the inertial coupling has been considered for a long time the only correct coupling system. Such rule, on the contrary, is only a useful indication. In fact, the minimum dimensioning of the motor, consideloop that the cost of a reducer is usually the double of the motor one, does not correspond to the cheapest application dimensioning. If we consider also that the application dynamic depends on the elasticity and on the differences of the transmission, it is not logic to optimize the ratio taking into consideration only the motor. In general, it is possible to state that: • any transmission ratio higher than the inertial ratio is not correct; • the best ratio is always lower or equal to the inertial one, and it is obtained consideloop the motor and reducer costs; • high ratios present always a passing belt and a lower degree of accuracy (with a higher energetic consumption) than what can be obtained with lower ratios. These considerations explain the today attempt to eliminate the reducers in order to operate in a direct way. When the load inertia is higher than the motor one, it is necessary to be particularly careful, because the motor inertia is no more able to carry out a stabilizing action on the possible mechanical resonances of the system. As a consequence, the mechanical system in these applications has to be of high quality, stiff and without differences, and the coupling without machine key (that is with keying device). Operating with a direct traction, it is necessary to check the torsional stiffness of the system. In particular you have to consider also the torsional elasticity of the motor shaft, which is significative in the case of motors longer than any other size. The series of brushless motors are superimposed, so that the same torque can be obtained with a long and narrow motor or with a short and stocky one. For this reason: • long motors have a minimum moment of inertia and they have to be used for high accelerations with low inertia loads; • stocky motors have a maximum torsional stiffness and they have to be used with loads whose inertia is sometimes higher than the motor one. Here is the formula expressing the torsional stiffness of a shaft whose diameter is D and whose length is L; the shaft is made of steel:

π

D4 Sm = • • 78.5 • 10 9 32 L while the first sequence of torsional resonance of a load with inertia JI connected to an axis with torsional stiffness Sm is given by the following formula:

F1 =

S 1 • m (2 • π ) Jl

If you decide to use an application with short times and with a high load inertia, it is necessary to set a proof of the first mechanical resonance of the system.

8.5 Choice of the feedback method The drive system can be set in three different operative ways: • torque control (the speed depends on the load); • speed control (the torque depends on the load); • position control

Phase Motion Control S.r.l., Genova, Italy

30

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 32

AX4 Drive

Application manual

The first operative way is the easiest and can be always used when it is necessary to control a power (winders/unwinders, textile machines and machines for the band processing, etc.). The torque control is generally steady (the steadiness does not depend on the load) and fast (passing belt >300 Hz), but not much accurate (~10%). In the multi-axes applications with very fast and modern CN, with an adaptive control or with variable parameters, it is necessary to set the drive in torque control and to assign the closing of the other loops to CN. As for the torque control the drive regulates the motor current; the motor therefore is also a transducer. No external sensors are necessary. The sensor on the motor can be semplified only to the Hall system for the motor commutation. The speed control is the most traditional. It usually uses an integrative term so that the speed error is limited to the system offsets. In the digital drives, the speed loop is obtained by the space loop (see). The position or space control is carried out only by digital drives (AX-V). In this operative way, the speed error is limited to a few calculations of the sensor, that is in the case of an encoder with 4096 pulse/revolutions, 1/16,000 of a revolution. In this operative way it is also possible to synchronize several axes (electrical axis).

8.6 Control of the electronics and motor dimensioning After choosing the motor and the transmission, it is necessary to control the application in an analytic way. Such control is immediate for applications with a speed and load which are quite steady or which may vary on the long term of the time constant of the motor (or of the electronics). In this case, it is necessary to control only that the maximum load is within the capacity specified for the motor and the electronics. For the applications where the load varies according to a fast cycle, it is necessary to act as follows: 1. Trace the speed/time diagram of the cycle, taking into consideration that the reaching of a precise position or speed requires, apart from the time stated by the limit accelerations of the system, also a period of settlement equal to 2-3 times the opposite of the system passing belt (see applications 1 and 2); 2. Bloop back the inertia and the loads of the system to the motor shaft; 3. Calculate the cycle of the accelerations and the inertial torques [accelerationx(motor inertia +load inertia brought back to the motor shaft)], without forgetting the inertia of the joints, keying devices and intermediate transmission devices; 4. Adding the load on the motor axis to the inertial torque it is possible to obtain a torque/time diagram in the cycle; 5. Calculate from the torque/time diagram the avarage square value of the torque: dividing the cycle into segments t1,t2....tn; if the torques given in each segment of the cycle are respectively C1,C2...Cn, the avarage square or effective torque in the cycle is:

( C • t + C • t +......C • t ) 6. Ceff = ( t + t +......t ) 2 1

2 2

1

1

2 n

2

2 n n

7. Calculate the avarage square or effective speed in the cycle ωeff with the same formula 8. Calculate the avarage torque in the cycle Cave 9. Calculate the maximum duration time of the maximum torque in the cycle tcmax 10. Calculate the required torque at the maximum speed Cwmax 11.Calculate the maximum torque Cpk The obtained data will be compared with the motor and electronic limits.

8.6.1 Motor limits The brushless motors are very good torque transducers, able to supply peak torques which sometimes are higher than the nominal ones. As a consequence, the obtainable peak torque is usually determined only by the choice of the electronic drive. The correct dimensioning of the motor is thermal and electric; the motor dimensioned in the right way is the one which stabilizes itself at the foreseen temperature, usually 40-50°C above the room temperature. The complete control of the dimensioning of the motor is carried out going through three different steps: 1. Control of the peak or smagnetizing torque; 2. Thermal dimensioning; 3. Electrical dimensioning. 1) Control of the smagnetizing current. It is carried out with a comparison with the max value of the peak current obtained via the following formula:

Phase Motion Control S.r.l., Genova, Italy

31

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 33

AX4 Drive

Application manual

I pk =

C pk Kt

• 2 and with the motor smagnetizing current, knowing that the motor smagnetizing current increases with a temperature lower than the max one which is indicated in the catalogues. Control of the thermal dimensioning. First of all it is necessary to control that the point Ceff, ωeff is included in the continuously functioning area of the chosen motor. More precisely, the temperature increase of the motor can be foreseen approximately via the following formula: 2 2

ϖ eff 65 Ceff ∆ Tmot = • • L + • L

0 n Ln Tn ϖn where Ln represents the nominal losses of the motor with an overheating of 65°C. If the foreseen temperature is higher than the motor max one or at least higher than the required one, it is necessary to use a bigger motor. Attention: the excessive temperature is the only possible reason for the choice of a bigger motor. 2) Control of the electric dimensioning. It is necessary to control that at the max speed the voltage required by the motor to supply the max useful torque is lower or equal to the one supplied by the electronics for the minimum main supply which can be foreseen (usually for a main equal to 90% of the voltage of the nominal main). If Emin is the voltage value which can be supplied by the electronic power supply at the minimum supply voltage, it is necessary to control that: 2

2

ϖ pk Rw C pk C pk PN Vmax = 3 • K e • + • • • ϖ pk • Lw ≤ Emin + Kt Kt 2 4 3

If this condition is not verified, it is necessary to choose a motor with a winding suitable for a higher speed, taking into consideration that this situation will require a higher current.

8.6.2 Electronic limitations The selection of the electronic size is carried out according to the torque which has to be supplied to the load and according to the chosen motor and winding, which determine the necessary current. It has to be underlined that contrary to the motor the thermal time constant of the electronics lasts a few seconds. Therefore the definition of the electronic overload or peak has a quite different meaning; each current supply lasting more than 2-3 seconds has to be considered as a continuative current. When the motor has been chosen, and when the value of its Kt is known, the peak and avarage currents required by the drive are expressed in this way:

I max =

C pk

I media =

Kt

Cave Kt

The electric drive should be able to supply continuative and peak currents higher than values resulting from these formulas, taking into consideration that the drive max current has to be compared to Imax only if Tcmax< 5 minutes. In all other cases, it is necessary to use a drive whose nominal current is higher than Imax. The amplifier supply main is not necessarily loaded with the same motor current: the amplifier in fact operates with an “electronic transformer”. In order to evaluate the max power required by the power supply, you have to consider the power required by the load and divide it by motor and electronic output (about 95%). It can happen that a drive supplying 50 A to a motor with a very low speed and with 5 A at the max speed is never able to load the main with more than 5 A.

8.6.3 Considerations about the electric supply The amplifier supply for the motor driving is converted in CC by the input stage of the amplifier, which is made up of a rectifier and a capacitor battery. The particular input stage of the amplifiers belonging to the series AX4 avoids the negative form factor typical of the conventional input stages and supplies a wave of the input current which has a square form, and which is practically in phase with the voltage. Therefore you will find a capacitive power factor with a 0,98 phase, and a 0,9 form factor. It is necessary therefore to overdimension the connections and the possible magnetothermal limiters both for the peak loads and for such values. When the electronics is switched on, it absorbes a current equal to 200% of the nominal one for about 0,01s in order to charge the internal capacitors. As for the use of differential limiters, all the RFI filters absorb a significative current on the ground connection of the drive; it is therefore necessary to take into consideration the use of differentials with a high intervention threshold (> 20 mA), still better if it is adjustable. With multi-axes applications with high wiloop capacities, it can be impossible to use a sole differential unless there is the presence of a supply transformer.

Phase Motion Control S.r.l., Genova, Italy

32

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 34

AX4 Drive

Application manual

Phase Motion Control S.r.l., Genova, Italy

33

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 35

AX4 Drive

Application manual

8.7 Recurring application problems It often happens to be impossible to dimension the application in a good way, either because the system is not well known or because the mechanics or the system are already in place. This section is destined to the diagnosis of the recurring applicative problems, of the most common errors and of the “fastest” and most suitable solutions. Noticed problem Cause The motor torque is not The motor is NOT sufficient to start the load underdimensioned: the electronics supplies insufficient current The motor overheats Underdimensioned motor The motor makes noises The motor is NOT and overheats underdimensioned; the electronics is not steady The motor is unsteady Wrong reaction parameters The motor does not rotate or rotates irregularly and in a idle way The motor follows the cycle but it is noisy

Wrong wiloop, loss of hall duct phase

Possible solutions Increase the current limit or the electronics size Control the dimensioning, increase the motor size Study the steadiness: change the parameters (decrease in proportion) Study the steadiness: change the parameters (decrease in proportion) Control the proportion of the power and signal cables, execute again the phasing

System with a marginal steadiness

Improve the mechanics (possible differences in the transmission); reduce the derivative term of the feedback loop The motor is noisy in the The system is not able to use a Improve the torsional steadiness application where the higher dynamic of the load; if it is impossible, others are not reduce the drive passing belt (decrease the proportional gain) The motor answers Insufficient gain in the electronics Increase the proportional and slowly and does not derivative terms follow the required cycle The motor does not too high Ke Change the motor with another reach the required one with a higher speed (it speed while the requires much more current) electronics is not at the current limit It is not possible to Stiffness mechanics, mechanical Improve the mechanics: obtain the required resonances eliminate the joints, the belts, accuracy and speed reduce the differences, increase without causing the shaft diameters, if possible unsteadiness operate in top gear

Phase Motion Control S.r.l., Genova, Italy

34

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 36

AX4 Drive

Application manual

ERRATA CORRIGE Ax17/23-2, Ax17/23-3 drives are replaced by Ax4/8-3 and Ax17/35-3 with features: Ax4/8-3

Ax17/35-3

Input Current

4

25

A

Nominal Power

2.6

15 kW

Output rms Current

4

25

Aeff

Output peak Current

8

55

Aeff

Mass

3.5

5.3 kg

Phase Motion Control S.r.l., Genova, Italy

35

1/96

AXM1 - 2

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 37

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment • FAST SHIPPING AND DELIVERY • TENS OF THOUSANDS OF IN-STOCK ITEMS • EQUIPMENT DEMOS • HUNDREDS OF MANUFACTURERS SUPPORTED • LEASING/MONTHLY RENTALS • ITAR CERTIFIED SECURE ASSET SOLUTIONS

SERVICE CENTER REPAIRS Experienced engineers and technicians on staff at our full-service, in-house repair center

WE BUY USED EQUIPMENT Sell your excess, underutilized, and idle used equipment We also offer credit for buy-backs and trade-ins www.artisantg.com/WeBuyEquipment

InstraView REMOTE INSPECTION

LOOKING FOR MORE INFORMATION? Visit us on the web at www.artisantg.com for more information on price quotations, drivers, technical specifications, manuals, and documentation

SM

Remotely inspect equipment before purchasing with our interactive website at www.instraview.com

Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com