The text of a manual · part 3 of 8
PNOZ Safety Relays: Safety relays PNOZ X, PNOZsigma and PNOZelog, Modular safety relays PNOZmulti and PNOZpower, pages 21 to 30
Pages 21 to 30 of 74
The original document is the PDF (4.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Pilz PNOZ X8P
Page 21
Features
Order numbers Cage clamp terminals
Plug-in screw terminals
• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • 2 semiconductor outputs
24 VDC ............................... 787 609 24 VDC, 100 … 240 VAC .................. 787 606
24 VDC ............................... 777 609 24 VDC, 100 … 240 VAC .................. 777 606
• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • 2 semiconductor outputs
24 VDC, 24 VAC ................. 787 080 110 … 120 VAC .................. 787 083 230 … 240 VAC .................. 787 086
24 VDC, 24 VAC ................. 777 080 110 … 120 VAC, 24 VDC ............................... 777 083 230 … 240 VAC, 24 VDC ............................... 777 086
• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected
0.1 … 3 s ............................ 787 601 1 … 30 s ............................. 787 602
0.1 … 3 s ............................ 777 601 1 … 30 s ............................. 777 602
• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected
3 s .................................... 787 512 30 s .................................... 787 510 More available on request
3 s .................................... 777 512 30 s .................................... 777 510 More available on request
• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • Universal power supply 24 … 240 VAC/DC
3 s selectable, 24 … 240 VAC/DC ............. 787 532 30 s selectable, 24 … 240 VAC/DC ............. 787 530 More available on request
3 s selectable, 24 … 240 VAC/DC ............. 777 532 30 s selectable, 24 … 240 VAC/DC ............. 777 530 More available on request
1)
Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZ X safety relays: Webcode 0685
Online information at www.pilz.com
19
Page 22
Technical details PNOZ X
Technical details – PNOZ X Compact, electromechanical safety relays – PNOZ X Type
Supply voltage
Outputs: Voltage/current/ rating
Dimensions in mm (H x W x D)
PMUT X1P
24 VDC
DC1: 24 V/8 A/200 W
101/941) x 90 x 121
P2HZ X1P
24 VDC 24, 42, 48 110, 115, 120, 230, 240 VAC
DC1: 24 V/2 A/50 W
101/941) x 45 x 122
P2HZ X4P
24 VAC/DC
DC1: 24 V/5 A/125 W
101/941) x 22.5 x 121
PSWZ X1P
24 … 240 VAC/DC
DC1: 24 V/6 A/150 W
101/941) x 45 x 122
PZE X4P
24 VDC
DC1: 24 V/5 A/120 W
101/941) x 22.5 x 122
PZE 9P
24 VAC/DC 100 … 240 VAC
DC1: 24 V/8 A/200 W
101/941) x 90 x 121
PMUT X1P
PSWZ X1P
PZE X4P
20
Page 23
Features
Order numbers Cage clamp terminals
Plug-in screw terminals
• Up to 4 muting sensors • Monitors and switches muting lamps • Parallel and serial muting • Simultaneity monitoring • 5 semiconductor outputs • Reset input • “Override” function via key switch in the case of a fault • LED status indicators
788 010
778 010
• 2 semiconductor outputs
24 VDC ............................... 787 340 More available on request
24 VDC ............................... 777 340 More available on request
• 22.5 mm width
24 VAC ............................... 787 354 24 VAC ............................... 787 355
24 VAC ............................... 777 354 24 VAC ............................... 777 355
• Safe standstill monitoring • 1 or 2-channel operation • No external components required • Fault signal if simultaneity time is exceeded • Reset input • Detects open circuits
UM: 0.5 V ............................. 787 949 UM: 3 V ................................ 787 950
UM: 0.5 V ............................. 777 949 UM: 3 V ................................ 777 950
• 1-channel operation
787 585
777 585
• Diverse structure • 2-channel operation with ability to detect shorts across contacts
24 VAC/DC ......................... 787 140 100 … 240 VAC .................. 787 148
24 VAC/DC ......................... 777 140 100 … 240 VAC .................. 777 148
1)
Height with cage clamp terminals/plug-in screw terminals
Technical documentation on PNOZ X safety relays: Webcode 0685
Online information at www.pilz.com
21
Page 24
Product range PNOZsigma
Compact safety relays PNOZsigma Maximum functionality in minimum width The new compact safety relays PNOZsigma combine many years of experience with today's very latest safety technology: you can achieve maximum safety and cost-effectiveness with minimum effort. All round efficiency – from planning to service PNOZsigma brings maximum efficiency – from planning to service.
With particularly narrow housing widths and multifunctionality compressed into each unit, PNOZsigma provides maximum functionality in minimum width. Use safety technology that • saves more space, • is more flexible, • is quicker, • and therefore more efficient.
Up to 50 % space saving • Widths from 12.5 mm • Housings up to 50 % narrower with the same functionality1) • Reduced space requirement in the control cabinet saves costs 1)
22
Compared with standard electromechanical safety relays on the market
Page 25
Benefits at a glance PNOZsigma
Rapid commissioning and expansion thanks to innovative connection technology • Just “click” to expand the contacts via a plug-in connection • Plug-in connection terminals • Innovative spring-loaded technology • Reduces wiring by up to 20 %
Your benefits at a glance • Up to 50 % space saving in the control cabinet • Rapid commissioning and expansion • High availability and diagnostics in seconds • Few unit types covering many safety functions
Fewer types – suitable for a variety of uses • Selectable operating modes and timers enable each unit to be flexible in its application • A single unit type monitors different safety functions • Your stockholding can be reduced to a few unit types
High plant availability and long service life • Rapid diagnostics at a glance • 6 descriptive LEDs • High switching capabilities up to 12 A • Safe switching even of the smallest loads from 10 mA
Keep up-to-date on PNOZsigma safety relays: Webcode 0994
Online information at www.pilz.com
23
Page 26
Product features PNOZsigma
The sum of our experience – PNOZsigma Selectable operating modes for maximum flexibility
Homogenous functional setup for rapid engineering
• Selectable reset modes: manual reset, automatic reset, monitored reset or reset with start-up test • Selectable operating mode: With or without detection of shorts across contacts • Selectable time delay: from 0 … 300 seconds – via value and factor • Selectable timer function: delay-on energisation, delay-on de-energisation, pulsing
• Standardised operator elements on each PNOZsigma • Identical terminal designation and positioning • Rapid allocation during configuration, installation and diagnostics
6 LEDs for diagnostics in seconds • Display switch and fault status: Power, In1, In2, Out, Reset and Fault • Identical on each PNOZsigma • No external measuring devices are required
24
New spring-loaded technology
Contact expansion via connectors
• Proven screwless terminal technology • With 2 terminal chambers per terminal point • For rapid wiring and a secure hold through the cage clamp • The opening for the two terminal chambers may be separate or joint • Wire may be removed individually
• Quick and easy • No wiring involved whatsoever
Spring clip for top-hat rail assembly • Rapid assembly, housing simply clips on and off • No need for tools
Page 27
Wiring reduced by 20%: Contact expansion via connectors
Rapid installation: new – innovative spring-loaded terminals, chambers operated individually
Simple configuration: all unit versions have a standardised terminal designation/position
Maximum flexibility: Selectable operating modes and timer functions
Rapid assembly via spring clips: no need for tools
0
1
2
Diagnostics in seconds: via 6 LEDs – no external measuring devices required
Safe from manipulation: setting elements have a lockable cover
25
Page 28
Selection guide PNOZsigma
Selection guide – PNOZsigma Compact safety relays – PNOZsigma Type
Category (in accordance with EN 954-1)
Performance Level PL (EN ISO 13849-1)
PNOZ s1
◆
◆
2 d
PNOZ s2
◆
◆
2 d
PNOZ s3
◆
◆
◆
4 e
PNOZ s4
◆
◆
◆
4 e
PNOZ s5
◆
◆
◆
4 e
◆
PNOZ s6
◆
EN 574, Type IIIC e
PNOZ s6.1
◆
EN 574, Type IIIA e
PNOZ s7
Contact expansion
Depends on base unit
Depends on base unit
PNOZ s8
Contact expansion
Depends on base unit
Depends on base unit
PNOZ s9
Contact expansion or safe timer relay
Depends on base unit as timer Cat. 4
Depends on base unit as timer PL e
Depends on base unit
Depends on base unit
PNOZ s10
26
Application
Contact expansion
◆
Page 29
Safety Integrity Level SIL CL (claim limit in accordance with IEC 62061)
Output contacts
Safe
Universal power supply Auxiliary contacts
Housing width in mm
48 … 240 VAC/DC
2
2
-
-
1
12.5
3
3
-
1
1
17.5
3
2
-
-
1
17.5
3
3
-
1
1
◆
22.5
3
2
2
-
1
◆
22.5
3
3
-
1
1
◆
22.5
3
3
-
1
1
◆
22.5
Depends on base unit
4
-
1
-
17.5
Depends on base unit
2
-
-
1
12.5
Depends on base unit as timer SIL3
-
3
1
-
17.5
Depends on base unit
4
-
1
-
45.0
Technical documentation on PNOZsigma safety relays: Webcode 0685
Online information at www.pilz.com
27
Page 30
Technical details PNOZsigma
Technical details – PNOZsigma Compact safety relays – PNOZsigma Type
Dimensions (H x W x D) in mm
Supply voltage (UB)
Outputs: Voltage/current/ rating
PNOZ s1
95 x 12.5 x 122
24 VDC
DC1: 24 V/3 A/75 W
PNOZ s2
95 x 17.5 x 122
24 VDC
DC1: 24 V/8 A/200 W
PNOZ s3
95 x 17.5 x 122
24 VDC
DC1: 24 V/8 A/200 W
PNOZ s4
95 x 22.5 x 122
24 VDC, 48 … 240 VAC/DC
DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W
PNOZ s5
95 x 22.5 x 122
24 VDC, 48 … 240 VAC/DC
DC1: 24 V/6 A/150 W
PNOZ s6
95 x 22.5 x 122
24 VDC, 48 … 240 VAC/DC
DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W
PNOZ s6.1
95 x 22.5 x 122
24 VDC, 48 … 240 VAC/DC
DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W
PNOZ s7
95 x 17.5 x 122
24 VDC
DC1: 24 V/8 A/200 W
PNOZ s8
95 x 12.5 x 122
24 VDC
DC1: 24 V/3 A/75 W
PNOZ s9
95 x 17.5 x 122
24 VDC
DC1: 24 V/8 A/200 W
PNOZ s10
95 x 45.0 x 122
24 VDC
DC1: 24 V/12 A/300 W
PNOZ s1
PNOZ s3
PNOZ s5
PNOZ s10
28