Page 21

Features

Order numbers Cage clamp terminals

Plug-in screw terminals

• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • 2 semiconductor outputs

24 VDC ............................... 787 609 24 VDC, 100 … 240 VAC .................. 787 606

24 VDC ............................... 777 609 24 VDC, 100 … 240 VAC .................. 777 606

• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • 2 semiconductor outputs

24 VDC, 24 VAC ................. 787 080 110 … 120 VAC .................. 787 083 230 … 240 VAC .................. 787 086

24 VDC, 24 VAC ................. 777 080 110 … 120 VAC, 24 VDC ............................... 777 083 230 … 240 VAC, 24 VDC ............................... 777 086

• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected

0.1 … 3 s ............................ 787 601 1 … 30 s ............................. 787 602

0.1 … 3 s ............................ 777 601 1 … 30 s ............................. 777 602

• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected

3 s .................................... 787 512 30 s .................................... 787 510 More available on request

3 s .................................... 777 512 30 s .................................... 777 510 More available on request

• 2-channel operation with or without detection of shorts across contacts • Monitored or automatic reset can be selected • Universal power supply 24 … 240 VAC/DC

3 s selectable, 24 … 240 VAC/DC ............. 787 532 30 s selectable, 24 … 240 VAC/DC ............. 787 530 More available on request

3 s selectable, 24 … 240 VAC/DC ............. 777 532 30 s selectable, 24 … 240 VAC/DC ............. 777 530 More available on request

1)

Height with cage clamp terminals/plug-in screw terminals Technical documentation on PNOZ X safety relays: Webcode 0685

Online information at www.pilz.com

19

Page 22

Technical details PNOZ X

Technical details – PNOZ X Compact, electromechanical safety relays – PNOZ X Type

Supply voltage

Outputs: Voltage/current/ rating

Dimensions in mm (H x W x D)

PMUT X1P

24 VDC

DC1: 24 V/8 A/200 W

101/941) x 90 x 121

P2HZ X1P

24 VDC 24, 42, 48 110, 115, 120, 230, 240 VAC

DC1: 24 V/2 A/50 W

101/941) x 45 x 122

P2HZ X4P

24 VAC/DC

DC1: 24 V/5 A/125 W

101/941) x 22.5 x 121

PSWZ X1P

24 … 240 VAC/DC

DC1: 24 V/6 A/150 W

101/941) x 45 x 122

PZE X4P

24 VDC

DC1: 24 V/5 A/120 W

101/941) x 22.5 x 122

PZE 9P

24 VAC/DC 100 … 240 VAC

DC1: 24 V/8 A/200 W

101/941) x 90 x 121

PMUT X1P

PSWZ X1P

PZE X4P

20

Page 23

Features

Order numbers Cage clamp terminals

Plug-in screw terminals

• Up to 4 muting sensors • Monitors and switches muting lamps • Parallel and serial muting • Simultaneity monitoring • 5 semiconductor outputs • Reset input • “Override” function via key switch in the case of a fault • LED status indicators

788 010

778 010

• 2 semiconductor outputs

24 VDC ............................... 787 340 More available on request

24 VDC ............................... 777 340 More available on request

• 22.5 mm width

24 VAC ............................... 787 354 24 VAC ............................... 787 355

24 VAC ............................... 777 354 24 VAC ............................... 777 355

• Safe standstill monitoring • 1 or 2-channel operation • No external components required • Fault signal if simultaneity time is exceeded • Reset input • Detects open circuits

UM: 0.5 V ............................. 787 949 UM: 3 V ................................ 787 950

UM: 0.5 V ............................. 777 949 UM: 3 V ................................ 777 950

• 1-channel operation

787 585

777 585

• Diverse structure • 2-channel operation with ability to detect shorts across contacts

24 VAC/DC ......................... 787 140 100 … 240 VAC .................. 787 148

24 VAC/DC ......................... 777 140 100 … 240 VAC .................. 777 148

1)

Height with cage clamp terminals/plug-in screw terminals

Technical documentation on PNOZ X safety relays: Webcode 0685

Online information at www.pilz.com

21

Page 24

Product range PNOZsigma

Compact safety relays PNOZsigma Maximum functionality in minimum width The new compact safety relays PNOZsigma combine many years of experience with today's very latest safety technology: you can achieve maximum safety and cost-effectiveness with minimum effort. All round efficiency – from planning to service PNOZsigma brings maximum efficiency – from planning to service.

With particularly narrow housing widths and multifunctionality compressed into each unit, PNOZsigma provides maximum functionality in minimum width. Use safety technology that • saves more space, • is more flexible, • is quicker, • and therefore more efficient.

Up to 50 % space saving • Widths from 12.5 mm • Housings up to 50 % narrower with the same functionality1) • Reduced space requirement in the control cabinet saves costs 1)

22

Compared with standard electromechanical safety relays on the market

Page 25

Benefits at a glance PNOZsigma

Rapid commissioning and expansion thanks to innovative connection technology • Just “click” to expand the contacts via a plug-in connection • Plug-in connection terminals • Innovative spring-loaded technology • Reduces wiring by up to 20 %

Your benefits at a glance • Up to 50 % space saving in the control cabinet • Rapid commissioning and expansion • High availability and diagnostics in seconds • Few unit types covering many safety functions

Fewer types – suitable for a variety of uses • Selectable operating modes and timers enable each unit to be flexible in its application • A single unit type monitors different safety functions • Your stockholding can be reduced to a few unit types

High plant availability and long service life • Rapid diagnostics at a glance • 6 descriptive LEDs • High switching capabilities up to 12 A • Safe switching even of the smallest loads from 10 mA

Keep up-to-date on PNOZsigma safety relays: Webcode 0994

Online information at www.pilz.com

23

Page 26

Product features PNOZsigma

The sum of our experience – PNOZsigma Selectable operating modes for maximum flexibility

Homogenous functional setup for rapid engineering

• Selectable reset modes: manual reset, automatic reset, monitored reset or reset with start-up test • Selectable operating mode: With or without detection of shorts across contacts • Selectable time delay: from 0 … 300 seconds – via value and factor • Selectable timer function: delay-on energisation, delay-on de-energisation, pulsing

• Standardised operator elements on each PNOZsigma • Identical terminal designation and positioning • Rapid allocation during configuration, installation and diagnostics

6 LEDs for diagnostics in seconds • Display switch and fault status: Power, In1, In2, Out, Reset and Fault • Identical on each PNOZsigma • No external measuring devices are required

24

New spring-loaded technology

Contact expansion via connectors

• Proven screwless terminal technology • With 2 terminal chambers per terminal point • For rapid wiring and a secure hold through the cage clamp • The opening for the two terminal chambers may be separate or joint • Wire may be removed individually

• Quick and easy • No wiring involved whatsoever

Spring clip for top-hat rail assembly • Rapid assembly, housing simply clips on and off • No need for tools

Page 27

Wiring reduced by 20%: Contact expansion via connectors

Rapid installation: new – innovative spring-loaded terminals, chambers operated individually

Simple configuration: all unit versions have a standardised terminal designation/position

Maximum flexibility: Selectable operating modes and timer functions

Rapid assembly via spring clips: no need for tools

0

1

2

Diagnostics in seconds: via 6 LEDs – no external measuring devices required

Safe from manipulation: setting elements have a lockable cover

25

Page 28

Selection guide PNOZsigma

Selection guide – PNOZsigma Compact safety relays – PNOZsigma Type

Category (in accordance with EN 954-1)

Performance Level PL (EN ISO 13849-1)

PNOZ s1

◆

◆

2 d

PNOZ s2

◆

◆

2 d

PNOZ s3

◆

◆

◆

4 e

PNOZ s4

◆

◆

◆

4 e

PNOZ s5

◆

◆

◆

4 e

◆

PNOZ s6

◆

EN 574, Type IIIC e

PNOZ s6.1

◆

EN 574, Type IIIA e

PNOZ s7

Contact expansion

Depends on base unit

Depends on base unit

PNOZ s8

Contact expansion

Depends on base unit

Depends on base unit

PNOZ s9

Contact expansion or safe timer relay

Depends on base unit as timer Cat. 4

Depends on base unit as timer PL e

Depends on base unit

Depends on base unit

PNOZ s10

26

Application

Contact expansion

◆

Page 29

Safety Integrity Level SIL CL (claim limit in accordance with IEC 62061)

Output contacts

Safe

Universal power supply Auxiliary contacts

Housing width in mm

48 … 240 VAC/DC

2

2

-

-

1

12.5

3

3

-

1

1

17.5

3

2

-

-

1

17.5

3

3

-

1

1

◆

22.5

3

2

2

-

1

◆

22.5

3

3

-

1

1

◆

22.5

3

3

-

1

1

◆

22.5

Depends on base unit

4

-

1

-

17.5

Depends on base unit

2

-

-

1

12.5

Depends on base unit as timer SIL3

-

3

1

-

17.5

Depends on base unit

4

-

1

-

45.0

Technical documentation on PNOZsigma safety relays: Webcode 0685

Online information at www.pilz.com

27

Page 30

Technical details PNOZsigma

Technical details – PNOZsigma Compact safety relays – PNOZsigma Type

Dimensions (H x W x D) in mm

Supply voltage (UB)

Outputs: Voltage/current/ rating

PNOZ s1

95 x 12.5 x 122

24 VDC

DC1: 24 V/3 A/75 W

PNOZ s2

95 x 17.5 x 122

24 VDC

DC1: 24 V/8 A/200 W

PNOZ s3

95 x 17.5 x 122

24 VDC

DC1: 24 V/8 A/200 W

PNOZ s4

95 x 22.5 x 122

24 VDC, 48 … 240 VAC/DC

DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W

PNOZ s5

95 x 22.5 x 122

24 VDC, 48 … 240 VAC/DC

DC1: 24 V/6 A/150 W

PNOZ s6

95 x 22.5 x 122

24 VDC, 48 … 240 VAC/DC

DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W

PNOZ s6.1

95 x 22.5 x 122

24 VDC, 48 … 240 VAC/DC

DC1: 24 V/8 A/200 W, DC1: 24 V/6 A/150 W

PNOZ s7

95 x 17.5 x 122

24 VDC

DC1: 24 V/8 A/200 W

PNOZ s8

95 x 12.5 x 122

24 VDC

DC1: 24 V/3 A/75 W

PNOZ s9

95 x 17.5 x 122

24 VDC

DC1: 24 V/8 A/200 W

PNOZ s10

95 x 45.0 x 122

24 VDC

DC1: 24 V/12 A/300 W

PNOZ s1

PNOZ s3

PNOZ s5

PNOZ s10

28