PNOZ Safety Relays: Safety relays PNOZ X, PNOZsigma and PNOZelog, Modular safety relays PNOZmulti and PNOZpower
Manual74 pagesPDF 4.7 MB
Pilz product catalog of PNOZ safety relays (PNOZ X, PNOZsigma, PNOZelog, PNOZmulti, PNOZpower), including the PNOZ X3P, X8P and X9P.
Names · 1 model
The models it names
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
Pilz catalog of its PNOZ safety relay ranges and PMDsrange electronic monitoring relays. For each range (PNOZ X, PNOZsigma, PNOZelog, and the modular PNOZmulti and PNOZpower systems) it gives a product overview, a selection guide and technical details such as supply voltages, output ratings, dimensions and order numbers. The PNOZ X tables include the PNOZ X3P, X8P and X9P. A flow chart helps choose a range by the number of safety functions and load.
Its parts
- Pilz product areas
- PMDsrange electronic monitoring relays
- PNOZ product group
- PNOZ X safety relays
- PNOZsigma safety relays
- PNOZelog safety relays
- Modular safety system PNOZmulti
- Modular safety system PNOZpower
From the manual
Key facts from this manual
Each line names its page in the PDF.
This Pilz catalog presents the PNOZ X, PNOZsigma and PNOZelog safety relays, the PNOZmulti and PNOZpower modular safety systems, and PMDsrange electronic monitoring relays. Among the PNOZ X relays it covers the PNOZ X3P, PNOZ X8P and PNOZ X9P (as printed), with supply voltages, output ratings and dimensions. Selection guides help a reader choose a product range and model for a safety function.
- Document
- Pilz product catalog of PNOZ safety relays, modular safety systems and PMDsrange monitoring relays p. 5
- PNOZ X8P supply
- PNOZ X8P: the manual states 24 VDC or 24, 110, 115, 120, 230 VAC p. 18
- PNOZ X8P outputs
- PNOZ X8P: the manual states DC1: 24 V/8 A/200 W p. 18
- PNOZ X8P size
- PNOZ X8P: 101/94 x 45 x 121 mm (H x W x D); height with cage clamp/plug-in screw terminals p. 18, 19
- PNOZ X range
- Electromechanical relays with voltage-free contacts, 22.5 to 90 mm wide, two to eight contacts p. 14
- Use
- One PNOZ per safety function; PNOZ X, PNOZsigma and PNOZelog suit up to 4 safety functions p. 7, 14
- PNOZ X3P
- PNOZ X3P: the manual states 24 VAC/DC or 24 … 240 VAC/DC supply, DC1: 24 V/8 A/200 W, 101/94 x 45 x 122 mm p. 18
- PNOZ X9P
- PNOZ X9P: the manual states 24 VDC or 24 VDC, 100 … 240 VAC supply, DC1: 24 V/8 A/200 W, 101/94 x 90 x 121 mm p. 20
- PNOZmulti
- Modular safety system for 4 to 14 safety functions p. 7
- PNOZmulti base units
- The manual states all base units have Performance Level e and Safety Integrity Level 3 p. 53
- PNOZpower
- The manual states high loads from 8 A to 16 A, switching motor loads directly p. 10
- PNOZmulti fieldbus
- Fieldbus modules for PROFIBUS-DP, DeviceNet, Interbus, CANopen, CC-Link, Ethernet IP/Modbus and PROFINET p. 52
What this manual walks you through
- Choosing a PNOZ product range with the selection chart p. 11
- Comparing PNOZ X relays by supply voltage, output rating and size p. 18, 20
- Understanding categories under EN 954-1 and performance levels under EN ISO 13849-1 p. 13
- Selecting PMDsrange voltage, current, insulation and temperature monitoring relays p. 8, 9
- Selecting PNOZsigma compact safety relays p. 28
- Selecting PNOZmulti input, output and fieldbus modules p. 52
- Selecting PNOZpower base units and output modules p. 68
Good to know
- For the PZE X4P and PZE 9P expander modules, the category depends on the base unit. p. 16
- The PNOZ X heights differ between cage clamp terminals and plug-in screw terminals. p. 19
Questions this manual answers
What supply voltage does the PNOZ X8P use?
The manual states 24 VDC or 24, 110, 115, 120, 230 VAC. p. 18
What is the output rating of the PNOZ X9P?
The manual states DC1: 24 V/8 A/200 W for the PNOZ X9P. p. 20
How big is the PNOZ X3P?
101/94 x 45 x 122 mm (H x W x D); the height depends on cage clamp or plug-in screw terminals. p. 18, 19
How many PNOZ relays are needed per safety function?
One PNOZ is used per safety function. p. 14
The whole text · 8 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file