For the Pilz PNOZ X8P

Page 51

Effective symbiosis of safety and standard Perform your automation functions more economically! PNOZmulti offers a selection of functionalities with which to monitor safety-related and standard control functions: • The connection module PNOZ ml1p for safe connection of two PNOZmulti base units. Additional base units can be networked either in tree or in ring structure. Several plants or machines can be networked to implement larger projects, enabling plant sections to be shut down selectively and commissioned. Benefits to you: reduced downtimes and increased productivity. • Fieldbus modules: in addition to diagnostic and status information, it is also possible to transmit controller information (commands) directly from the controller to the PNOZmulti via the fieldbus.

• Input module PNOZ mi2p with eight inputs to monitor standard control functions – cost benefit guaranteed. • Output module PNOZ mc1p with 16 auxiliary outputs for issuing status messages to a higher-level PLC.

Monitor safety mats safely Use the PNOZmulti as an evaluation device for safety mats. PNOZmulti is approved in accordance with Annex 4 of the Machinery Directive and EN 954-1 in conjunction with EN 1760. This means that the safety mat and the PNOZmulti safety relay are recognised as one unit. No additional evaluation devices are required. Take advantage of the possibilities of the multifunctional PNOZmulti safety system. Monitor safety functions such as E-STOP, safety gate, time and standstill, as well as monitoring safety mats, in just one unit. No need for wiring so you save valuable time.

Simple connection of standard control functions and safety functions in the PNOZmulti Configurator.

49

Page 52

Selection guide PNOZmulti

Selection guide – PNOZmulti Modular safety system – PNOZmulti Type

Application area

Performance Level PL1) (EN ISO 13849-1)

Safety Integrity Level SIL CL1) (claim limit in accordance with IEC 62061)

PNOZ mi1p

Safe input module e

3

PNOZ mi2p

Input module e

3

PNOZ mo1p

Safe semiconductor output module e

3

PNOZ mo3p

2-pole, safe semiconductor output module e

3

PNOZ mo2p

Safe relay output module e

3

PNOZ mo4p

Safe relay output module e

3

PNOZ mc1p

Output module

-

-

PNOZ ms2p

Safe speed/standstill monitoring module e

3

Safety Control

PNOZ ml1p

Safe connection module e

3

UT

PNOZ mc3p

Fieldbus module PROFIBUS-DP

-

-

PNOZ mc4p

Fieldbus module DeviceNet

-

-

PNOZ mc5p

Fieldbus module Interbus

-

-

PNOZ mc5.1p

Fieldbus module Interbus LWL

-

-

PNOZ mc0p

Power supply for Interbus fieldbus modules PNOZ mc5p and PNOZ mc5.1p

-

-

PNOZ mc6p

Fieldbus module CANopen

-

-

PNOZ mc7p

Fieldbus module CC-Link

-

-

PNOZ mc8p

Fieldbus module Ethernet IP/Modbus

-

-

PNOZ mc9p

Fieldbus module PROFINET

-

-

A

N

M PLETE CO

O M ATI O

50

Page 53

Connection of expansion modules to base unit2) PNOZ m0p

PNOZ m1p

PNOZ m1p (coated version)

PNOZ m2p (press applications)

3…6 Safety functions

≥4 Safety functions

≥4 Safety functions

≥4 Safety functions

◆

◆

◆ ◆

◆ ◆

◆

◆

◆ ◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

◆

1)

◆

◆ ◆

◆

◆

Maximum achievable value, depending on the application, e.g. number of outputs. 2) All base units have Performance Level e and Safety Integrity Level 3.

Technical documentation on PNOZmulti modular safety systems: Webcode 0685

Online information at www.pilz.com

51

Page 54

Technical details PNOZmulti

Technical details – PNOZmulti Modular safety system PNOZmulti Controller – Base units CO

M PLETE

Type

Application area

Application range in accordance with EN 954-1, Category 2, 3 and 4

PNOZ m0p

Base unit – from 3 … 6 safety functions

E-STOP, two-hand buttons, safety gate limit switch, light barriers, scanner, enable switch, PSEN safety gate switch, operating mode selector switch, muting, safety mats, sensors

A

UT

N

Safety Control O M ATI O

Fieldbus modules can be connected; no other expansion modules can be connected

PNOZ m0p

PNOZ m1p/ PNOZ m1p (coated version)

Base unit – from 4 safety functions; also for standard control functions

PNOZ m2p

Base unit – specifically for press applications

As PNOZ m1p, additional monitoring of operating modes such as set-up mode, singlestroke and automatic; safety light curtains in single-break and double-break mode, camshaft with run monitoring, press safety valves, muting, safety mats, sensors

Modular safety system PNOZmulti I/O – Input modules

PNOZ mi1p

Type

Application range

Inputs/outputs

PNOZ mi1p/ PNOZ mi1p (coated version)

Safe input module

8 safe inputs

PNOZ mi2p

Input module

8 inputs

Common features • Supply voltage (UB): 24 VDC via base unit • Dimensions (H x W x D): 94 x 22.5 x 121 mm

52

Page 55

Features

1)

Order numbers Cage clamp terminals

Plug-in screw terminals

• Can be configured using the PNOZmulti Configurator via chip card or RS 232 interface • Exchangeable program memory • Diagnostic interface • Fieldbus modules can be connected • Max. 8 expansion modules can be connected • PNOZ m1p/PNOZ m2p: Max. 8 expansion modules can be connected • Inputs/outputs: 20 freely configurable inputs, 4 test pulse outputs, 1 auxiliary output Outputs using semiconductor technology: - Category 4: 2 safety outputs - Category 3: 4 safety outputs Relay outputs: - Category 4: 1 safety contact - Category 2: 2 safety contacts • Supply voltage (UB): 24 VDC • Voltage/current/rating: - Outputs using semiconductor technology: 24 VDC/2 A/48 W - Relay outputs: DC1: 24 V/6 A/144 W • Dimensions (H x W x D): 94 x 135 x 121 mm

773 110 (excl. terminals)

783 100 (1 set)

793 100 (1 set)

• 773 100 (excl. terminals) • 773 105 (coated version, excl. terminals)

783 100 (1 set)

793 100 (1 set)

773 120 (excl. terminals)

783 100 (1 set)

793 100 (1 set)

Features

Order numbers Cage clamp terminals

Plug-in screw terminals

1)

• Max. 8 input modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

• 773 400 (excl. terminals) • 773 405 (coated version, excl. terminals)

783 400 (1 set)

793 400 (1 set)

• Max. 8 input modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 410 (excl. terminals)

783 400 (1 set)

793 400 (1 set)

1)

Technical documentation on PNOZmulti modular safety systems: Webcode 0685

Online information at www.pilz.com not for PNOZ mi2p

53

Page 56

Technical details PNOZmulti

Technical details – PNOZmulti Modular safety system PNOZmulti I/O – Output modules CO

M PLETE

Type

Application range

Inputs/outputs

Supply voltage

PNOZ mo1p/ PNOZ mo1p (coated version)

Safe semiconductor output module: Switching 24 V actuators

• Outputs use semiconductor technology: - Category 4: 2 safety outputs - Category 3: 4 safety outputs

24 VDC

PNOZ mo3p

Safe semiconductor output module, 2-pole

• 2-pole outputs use semiconductor technology: - Category 4: 2 safety outputs

24 VDC via expansion module

PNOZ mo2p/ PNOZ mo2p (coated version)

Safe relay output module: Volt-free switching of actuators

• Relay outputs: - Category 4: 1 safety output - Category 2: 2 safety outputs

24 VDC via base unit

PNOZ mo4p/ PNOZ mo4p (coated version)

Safe relay output module: Volt-free switching of actuators

• Relay outputs: - Category 4: 2 safety outputs - Category 2: 4 safety outputs

24 VDC via base unit

PNOZ mc1p/ PNOZ mc1p (coated version)

Output module: Status message to SPS

• 16 auxiliary outputs use semiconductor technology

24 VDC

A

UT

N

Safety Control O M ATI O

PNOZ mo1p

PNOZ mc1p

Common features • Dimensions (H x W x D): 94 x 22.5 x 121 mm, PMOZ mc1p: 94 x 45 x 121 mm

54

Page 57

Outputs: Voltage/ current/rating

Features

24 VDC/2 A/48 W

• Max. 6 semiconductor output modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

24 VDC/2 A

Order numbers Cage clamp terminals

Plug-in screw terminals

• 773 500 (excl. terminals) • 773 505 (coated version, excl. terminals)

783 400 (1 set)

793 400 (1 set)

• Max. 6 semiconductor output modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 510 (excl. terminals)

783 400 (1 set)

793 400 (1 set)

DC1: 24 V/6 A

• Max. 6 semiconductor output modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

• 773 520 (excl. terminals) • 773 525 (coated version, excl. terminals)

783 520 (1 set)

793 520 (1 set)

DC1: 24 V/6 A

• Max. 6 semiconductor output modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

• 773 536 (excl. terminals) • 773 537 (coated version, excl. terminals)

783 536 (1 set)

793 536 (1 set)

-

• Max. 8 output modules can be connected to the base unit • Connected to base unit via a link on the back of the unit

• 773 700 (excl. terminals) • 773 705 (coated version, excl. terminals)

783 700 (1 set)

793 700 (1 set)

Technical documentation on PNOZmulti modular safety systems: Webcode 0685

Online information at www.pilz.com

55

Page 58

Technical details PNOZmulti

Technical details – PNOZmulti Modular safety system PNOZmulti I/O – Monitoring module Type

Application range

Dimensions (H x W x D) in mm

PNOZ ms1p/ PNOZ ms2p

Safe speed and standstill monitoring module in accordance with EN 954-1, Category 3: for safe speed and standstill monitoring via incremental encoders or proximity detectors.

94 x 45 x 121

PNOZ ms1p

Modular safety system PNOZmulti COM – Connection module Type

Application range

Dimensions (H x W x D) in mm

PNOZ ml1p

Connection module: for safe connection of two PNOZmulti base units

94 x 22.5 x 121

Modular safety system PNOZmulti PAA – Cable Type

Application range

Dimensions (H x W x D) in mm

PNOZ msi1p … and more

Connection cable for PNOZ ms1p/ PNOZ ms2p in accordance with EN 954-1, Category 3: to connect incremental encoders

On request

PNOZ mli1p

Connection cable for the PNOZ ml1p

5 m, 10 m, 50 m

PNOZ msi1p

56

Page 59

Features

• Supply voltage (UB): 24 VDC via base unit • Up to 8 limit values can be configured using the PNOZmulti Configurator • Proximity detectors are connected directly to the terminals on the PNOZ ms1p/PNOZ ms2p • Incremental encoders are connected via connection cable • PNOZ ms2p: - Incremental encoder with differential output signals from 0.5 Vss to 30 Vss, i.e. now also suitable for HTL encoders - Independent from the supply voltage of the incremental encoder, i.e. also for encoders with 8 V supply voltage, for example • Two axes can be monitored independently • Max. 4 modules can be connected to the base unit • Can be evaluated in the PNOZmulti Configurator • Connected to base unit via plug-in connector on the back of the unit

1)

Order numbers

• 773 800 PNOZ ms1p (excl. terminals) • 773 810 PNOZ ms2p (excl. terminals)

Cage clamp terminals

Plug-in screw terminals

783 800 (1 set)

793 800 (1 set)

2)

1)

Features

• Point-to-point connection via 4-core screened cable • Transfer of 32 bit input data and 32 bit output data • Several PNOZmulti base units can be networked by linking additional connection modules – either in tree or in ring structure

Features

Order numbers

• 773 540 (excl. terminals)

Cage clamp terminals

Plug-in screw terminals

783 400 (1 set)

793 400 (1 set)

Order numbers

Pending for PNOZ ml1p 2) Not for PNOZ ml1p

Technical documentation on PNOZmulti modular safety systems: Webcode 0685

• Used to connect an incremental encoder to the speed monitors PNOZ ms1p/PNOZ ms2p • Connection cable for all common makes of drive • Connection to drive and incremental encoder via 25-pin or 15-pin D-Sub male and female connector, or wired with stranded cable • Variable cable lengths

• PNOZ msi1p 25/25 Si/Ha, 2.5 m ......................773 850 • PNOZ msi5p 15/15 Bo/Rex, 2.5 m ...................773 857 • PNOZ msi15p 15/15 PMCtendo, 2.5 m ...........773 874

• Ready-made as spring-loaded or screw terminal type • Screened

• 5 m ....................................................................773 890

Online information at www.pilz.com

• Other versions available

• Other versions available

57

Page 60

Technical details PNOZmulti

Technical details – PNOZmulti CO

M PLETE

Modular safety system PNOZmulti COM – Fieldbus modules

Safety Control

Application range

Supply voltage (UB)

PNOZ mc3p

Fieldbus module PROFIBUS-DP

24 VDC via base unit

PNOZ mc4p/ PNOZ mc4p (coated version)

Fieldbus module DeviceNet

24 VDC via base unit

PNOZ mc5p

Fieldbus module Interbus

24 VDC via base unit

PNOZ mc5p

PNOZ mc5.1p

Fieldbus module Interbus LWL

24 VDC via base unit

PNOZ mc5.1p

PNOZ mc0p

Power supply for fieldbus modules PNOZ mc5p and PNOZ mc5.1p

24 VDC

N

A

UT

Type

O M ATI O

PNOZ mc3p

PNOZ mc4p

PNOZ mc0p

58