For the Pilz PNOZ X8P

Page 61

Dimensions (H x W x D) in mm

Features

Order numbers

94 x 22.5 x 119

• Can be configured using the PNOZmulti Configurator • Station addresses from 0 … 99, selected via rotary switch • Status indicators via LEDs • Subscriber (Slave) on PROFIBUS-DP • Transmission rate: Max. 12 MBit/s • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 721

94 x 22.5 x 122

• Can be configured using the PNOZmulti Configurator • Station addresses from 0 … 63, selected via DIP switch • Status indicators via LEDs • Subscriber (Slave) on DeviceNet • Transmission rate: 125, 250, 500 kBit/s • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 722 coated version ...... 773 729

94 x 22.5 x 119

• Can be configured using the PNOZmulti Configurator • Status indicators via LEDs • Subscriber (Slave) on Interbus • Transmission rate selected via jumper • Transmission rate: 500 kBit/s, 2 MBit/s • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 723

94 x 22.5 x 121

• Can be configured using the PNOZmulti Configurator • Subscriber (Slave) on Interbus with fibre-optic cable • Transmission rate, selectable between 500 kBit/s or 2 MBit/s • Status indicators for communication with Interbus and for errors • Max. 1 fieldbus module can be connected to the base unit • FSMA connection technology • Connected to base unit via a link on the back of the unit

773 728

• Interface to connect the base unit and a fieldbus module • Galvanic isolation • Max. 1 fieldbus module (PNOZ mc5p or PNOZ mc5.1p) can be connected • Status indicators • Plug-in terminals (either with cage clamp or screw connection) • Connected to base unit via a link on the back of the unit

773 720

94 x 22.5 x 121

Technical documentation on PNOZmulti modular safety systems: Webcode 0685

Online information at www.pilz.com

59

Page 62

Technical details PNOZmulti

Technical details – PNOZmulti CO

M PLETE

Modular safety system PNOZmulti COM – Fieldbus modules

A

UT

Type

Application range

Supply voltage (UB)

PNOZ mc6p

Fieldbus module CANopen

24 VDC via base unit

PNOZ mc7p

Fieldbus module CC-Link

24 VDC via base unit

PNOZ mc8p

Fieldbus module Ethernet/IP, Modbus TCP

24 VDC via base unit

PNOZ mc9p

Fieldbus module PROFINET IO Device

24 VDC via base unit

N

Safety Control O M ATI O

PNOZ mc6p

PNOZ mc7p

PNOZ mc8p

PNOZ mc9p

60

Page 63

Dimensions (H x W x D) in mm

Features

Order numbers

94 x 22.5 x 122

• Can be configured using the PNOZmulti Configurator • Station addresses from 0 … 99, selected via rotary switch • Status indicators via LEDs • Subscriber (Slave) on CANopen • Transmission rate selected via rotary switch • Transmission rate: Max. 1 MBit/s • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 724 coated version ...... 773 727

94 x 22.5 x 122

• Can be configured using the PNOZmulti Configurator • Station addresses from 1 … 63, selected via rotary switch • Status indicators via LEDs • Subscriber (Slave) on CC-Link • Occupied stations: 2 • Transmission rate selected via rotary switch • Transmission rate: Max. 10 MBit/s • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 726 coated version ...... 773 725

94 x 22.5 x 114

• Can be configured using the PNOZmulti Configurator • Subscriber on Ethernet/IP (Adapter) or Modbus TCP (Slave) • Transmission rate 10 MBit/s • Status indicators via LEDs • IP address is set via DIP switches on the front of the unit • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 730

94 x 22.5 x 114

• Device name can be configured in the PNOZmulti Configurator • Subscriber on PROFINET IO (PROFINET IO Device) • Diagnostics and alarm functions are not supported • Status indicators via LEDs • Max. 1 fieldbus module can be connected to the base unit • Connected to base unit via a link on the back of the unit

773 731 Technical documentation on PNOZmulti modular safety systems: Webcode 0685

Online information at www.pilz.com

61

Page 64

Technical details PNOZmulti

Technical details – PNOZmulti Modular safety system PNOZmulti PASsystem – Software Type

Features

PNOZmulti Configurator

• Runs under Windows® 2000 and XP • Project planning, configuration generation, documentation, commissioning • Data transfer via standard serial cable or via a chip card • Graphic configuration of safety circuit

PNOZmulti Service Tool

• PNOZmulti service tool is a supplement for the configuration software PNOZmulti Configurator. • Purpose: Troubleshooting and diagnostics for service and maintenance; downloading projects • Any options that modify a project are disabled, i.e. the service tool is unable to change a project

Modular safety system PNOZmulti PAA – Accessories

62

Type

Features

PNOZmulti Tool Kit

• The Tool Kit contains the accessories you need to start working with PNOZmulti: - Documentation folder with the PNOZmulti Configurator - Chip card reader to write and save the configuration on to a chip card - Chip card set consisting of 10 chip cards, including a chip card adapter for rewriting chips removed from the chip card - Configuration cable for reading diagnostic data

Page 65

Order numbers Documentation folder with software on CD-ROM

Software incl. documentation on CD-ROM

Licence type

773 0002)

773 000D2)

773 010…3)

773 0052)

-

773 011…3)

Order numbers PNOZmulti Tool Kit

Chip card reader

Chip card set

Configuration cable

Documentation folder with PNOZmulti Configurator

Licence type

779 000

779 2303)

8 kB ...779 2001) 32 kB ...779 2121)

310 3001)

773 000…2)

773 010…3)

Technical documentation on PNOZmulti modular safety systems: Webcode 0685 1)

For use only with subsequent orders 2) Please order licence separately; it is required in order to enable the software. 3) Please state the type of licence you require after the order number (..B for basic licence; ..K for user licence; ..G for project licence), e. g. 773 010B. Time-restricted licences for PNOZmulti Configurator: …S (2 months), …R (3 months) or …Q (4 months).

Online information at www.pilz.com

63

Page 66

Product range PNOZpower

Modular safety system PNOZpower Switching high loads safely The modular PNOZpower safety system is suitable for monitoring E-STOPs, safety gates and light beam devices. PNOZpower can switch currents of up to 16 A AC/DC per contact. An overall breaking capacity of 40 A is available per module. In each case, external contactors and contactor combinations are no longer required.

SAFE BREAK

SAFE

HIGH ALIGN LOW ALIGN POWER ON

POWER ON

OPEN FOR SETTING

RECEIVER

EMITTER

Modular and flexible The base module processes the inputs, the output modules are specifically matched to the respective load. The number and capacity of the required safety contacts can be scaled, depending on the application. A maximum of five modules can be connected to the base unit. Modules are wired to the base unit via an internal bus system.

PNOZ po3.3p

64

Example: using the modular safety system PNOZpower on a packaging machine.

PNOZ p1p

PNOZ po3.1p

PNOZ po3.2p

Page 67

Benefits at a glance PNOZpower

Your benefits at a glance

1 2 3 4

PSEN 1.1p-20 Ident. No. 524120

PSEN 1.1-20 Ident. No. 514120

03000000

03000000

• External contactor combinations and their respective wiring are no longer required, saving costs, space and commissioning time • Diagnostics via LED: operating and fault status can be scanned on each module, resulting in fewer downtimes • Plug-in connection terminals: pre-wired and easy to exchange if there is a fault • Redundant load switching • Scalable and flexible through the selection of compatible modules – you only pay for the functions that you actually use. • Complete solution comprising evaluation devices, compatible sensor technology and control and signal devices

Connection to PNOZmulti

X3

13 O4 14 23 O5 24

X2

O0 O1 O2 O3 OA0 24V 24V 0V 0V

X1

CI+ CI CO CO+ T0 T1 T2 T3

CHIP-Card

PNOZpower modules can be connected to the modular PNOZmulti safety system via the coupling connector PNOZ pe2p.

Keep up-to-date on PNOZpower modular safety systems: Webcode 0245

Online information at www.pilz.com

I8 I9 I10 I11 I12 I13 I14 I15 I16 I17 I18 I19

A1 A1 A2 A2

X4

I0 I1 I2 I3 I4 I5 I6 I7

POWER RUN DIAG FAULT I FAULT O FAULT

PNOZ m1p

X5

X6

X7

Combine the PNOZpower and PNOZmulti modular safety systems easily using the coupling connector PNOZ pe2p. 65

Page 68

Selection guide PNOZpower

Selection guide – PNOZpower Modular safety system – PNOZpower Type

Application area

Application

Performance Level PL (EN ISO 13849-1)

PNOZ p1p

Base unit

◆

◆

◆

PNOZ p1vp

Base unit, delayed

◆

◆

◆

PNOZ pe1p

Control module

For control via safety contacts or safe semiconductor outputs e

PNOZ pe2p

Bus interface

Coupling connector to connect expansion modules to a higher-level control system e

PNOZ pps1p

Power supply

-

- e ◆ e (d)

Modular safety system – PNOZpower Type

Output contacts Safe

66

Non-safe

1

Performance Level PL (EN ISO 13849-1)

PNOZ po3p

3 e

PNOZ po3.1p

8 e

PNOZ po3.2p

4 e

PNOZ po3.3p

3 e

PNOZ po4p

4 e

Page 69

Safety Integrity Level SIL CL (claim limit in accordance with IEC 62061)

Number of expansion modules

Supply voltage

Housing width in mm

3

Min. 1, max. 4 expansion modules

24 VDC

45

3

Min. 1, max. 8 expansion modules (max. 4 delayed and 4 instantaneous)

24 VDC

45

3

Min. 1, max. 4 expansion modules

24 VDC

22.5

3

Min. 1, max. 6 expansion modules

24 VDC

23.5

-

-

100 … 240 VAC

45

Safety Integrity Level SIL CL (claim limit in accordance with IEC 62061)

Outputs: Voltage/current/rating AC1

AC3

Housing width in mm DC1

3

240 V/4 A/960 VA

-

24 V/4 A/96 W

22.5

3

240 V/8 A/2000 VA

-

24 V/8 A/200 W

45

3

240 V/16 A/4000 VA

-

24 V/16 A/400 W

90

3

240 V/16 A/4000 VA 400 V/10 A/4000 VA 500 V/8 A/4000 VA

240 V/3.0 kW 400 V/5.5 kW 500 V/4.0 kW

24 V/16 A/400 W

90

3

240 V/4 A/960 VA

-

24 V/4 A/96 W

22.5

Technical documentation on PNOZpower modular safety systems: Webcode 0685

Online information at www.pilz.com

67

Page 70

Technical details PNOZpower

Technical details – PNOZpower Modular safety system – PNOZpower

PNOZ p1p

Type

Application area

Supply voltage

Dimensions (H x W x D) in mm

PNOZ p1p

Base unit

24 VDC

94 x 45 x 135

PNOZ p1vp

Base unit, delayed

24 VDC

94 x 45 x 135

PNOZ pe1p

Control module

24 VDC

94 x 22.5 x 135

PNOZ pe2p

Bus interface

24 VDC

22 x 23.5 x 29

PNOZ pe1p

PNOZ pe2p