Spec sheet · Pilz
PNOZ X8P, E-STOP relays, safety gate monitors, Up to PL e of EN ISO 13849-1
Spec sheet9 pagesPDF 441 KB
Data sheet for the Pilz PNOZ X8P safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices, up to PL e.
Covers · 1 model
The models it covers
Summary
What is in it
Pilz's data sheet for the PNOZ X8P, a safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices. It describes the unit features and safety features, single and dual-channel operation, automatic, manual and monitored reset, the timing diagram, wiring for supply, input, reset and feedback circuits and the semiconductor outputs, terminal layout, installation, dimensions and full technical details by order number.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Pilz data sheet for the PNOZ X8P safety relay, which monitors E-STOP pushbuttons, safety gates and light beam devices. It covers unit features, operating and reset modes, wiring of the input, reset and feedback circuits, installation and technical data. It says it is meant for configuration, with installation and operation left to the operating instructions.
- Device type
- Safety relay for monitoring E-STOP pushbuttons and safety gates p. 1
- Relay outputs
- 3 safety contacts (N/O) and 2 auxiliary contacts (N/C), instantaneous, positive-guided p. 1
- Semiconductor outputs
- 2; signal switch status of channel 1/2 and that supply voltage is present p. 1
- Inputs
- E-STOP pushbutton, safety gate limit switch, reset button, light barriers p. 1
- Operating modes
- Single-channel, or dual-channel with or without detection of shorts across contacts p. 2
- Reset modes
- Automatic start, manual reset or monitored reset p. 2
- Indicators
- LEDs for switch status of channel 1/2 and supply voltage p. 1
- Terminals
- Plug-in, spring-loaded or screw terminals p. 1
- Order versions
- 24 VDC, 24 VAC, 110 VAC, 115 VAC, 120 VAC and 230 VAC p. 9
- Mounting
- Vertical 35 mm DIN rail, in a control cabinet of at least IP54 p. 5
- Dimensions
- 45 x 94 x 121 mm; 101 mm in place of 94 with spring-loaded terminals p. 5
- Wire
- Copper wire that can withstand 60/75 °C p. 2
- Standards
- The data sheet states it meets EN 60947-5-1, EN 60204-1 and VDE 0113-1, up to PL e of EN ISO 13849-1 p. 1
- Self-monitoring
- Redundant circuit with built-in self-monitoring; relay switching tested in each on-off cycle p. 1
What this sheet walks you through
- Wiring the supply voltage and the E-STOP, safety gate and light beam input circuits p. 3
- Wiring the reset circuit for automatic, manual or monitored reset p. 4
- Wiring the feedback circuit for external contactors p. 4
- Calculating the maximum cable run in the input circuit p. 2
- Mounting the unit on a DIN rail p. 5
- Terminal configuration p. 5
Good to know
- The data sheet is for configuration only; installation and operation follow the supplied operating instructions. p. 6
- Fit a fuse before the output contacts to prevent contact welding. p. 2
- Output contacts with capacitive and inductive loads need sufficient fuse protection. p. 2
- Secure the unit on the vertical DIN rail with a fixing element such as a retaining bracket or end angle. p. 5
- Single-channel operation has no redundancy in the input circuit. p. 2
Questions this sheet answers
How many safety contacts does the PNOZ X8P have?
Three N/O safety contacts and two N/C auxiliary contacts, plus two semiconductor outputs. p. 1
Can I add more safety contacts to a PNOZ X8P?
Yes, by connecting contact expansion modules or external contactors. p. 2
Which PNOZ X8P terminals are the safety contacts?
Outputs 13-14, 23-24 and 33-34 are safety contacts; 41-42 and 51-52 are auxiliary contacts. p. 2
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file