Manual · Pilz
PNOZ X8P Operating instructions
Manual20 pagesPDF 529 KB
Operating instructions for the Pilz PNOZ X8P safety relay: functions, operating modes, wiring examples, faults and technical data.
Covers · 1 model
The models it covers
Summary
What is in it
Multilingual operating instructions (German, English, French) for the Pilz PNOZ X8P safety relay, used to interrupt a safety circuit in applications with E-STOP pushbuttons, safety gates and light barriers. It covers safety regulations, the device description and functions, semiconductor outputs, single- and two-channel operating modes, automatic and manual reset, installation and wiring steps, connection examples, fault behavior and technical data.
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operating instructions for the Pilz PNOZ X8P safety relay; the pages read print German, English and French side by side. They explain what the relay does, its operating and reset modes, how to wire the input, reset and feedback circuits, the faults it shows, and its technical data.
- Device type
- Safety relay in a 45 mm P-99 housing for safety-related interruption of a safety circuit p. 1
- Relay outputs
- 3 safety contacts (N/O) and 2 auxiliary contacts (N/C), positive-guided p. 1
- Supply versions
- One 24 V DC version and AC versions for UB = 24 ... 230 V AC p. 1, 6
- Semiconductor outputs
- Y35 on with supply present and internal fuse healthy; Y32 on when K1 and K2 energise; 24 V DC / 50 mA p. 2, 6
- Output contact fuse
- 10 A quick or 6 A slow fuse, or 24 V AC/DC: 6 A safety cut-out (B/C) p. 3, 6
- Contact rating EN 60947-4-1
- AC1: 240 V/0.01 ... 8 A/2000 VA; DC1: 24 V/0.01 ... 8 A/200 W p. 6
- Contact rating EN 60947-5-1
- AC15: 230 V/5 A; DC13: 24 V/7 A (6 cycles/min) p. 6
- Ambient temperature
- -10 ... + 55 °C; storage -40 ... +85 °C p. 7
- Dimensions
- 94 x 45 x 121 mm (H x W x D) with screw terminals; 101 x 45 x 121 mm with spring-loaded terminals p. 7
- Weight
- 320 g (24 V DC); 420 g (24 ... 230 V AC) p. 7
- Max. cable resistance
- Single-channel 100 Ohm; dual-channel without short detection 200 Ohm; with short detection 16 Ohm DC, 28 Ohm AC p. 6
- Release time at E-STOP
- Typ. 15 ms, max. 30 ms p. 7
- Screw terminal wire
- 1 core flexible 0.25 ... 2.5 mm2, 24 - 12 AWG; torque 0.5 Nm p. 7
- Stated safety level
- The manual states PL e (Cat. 4) to EN ISO 13849-1 and SIL CL 3 to EN IEC 62061 p. 6
What this manual walks you through
- Wiring the supply and a single- or two-channel input circuit p. 4
- Wiring the reset circuit for automatic, manual or monitored reset p. 4
- Connecting external contactors to the feedback control loop p. 4
- Powering the semiconductor outputs p. 4
- Reactivating the relay after the input circuit opens p. 4
- Testing short detection after installation p. 3
- Calculating the maximum cable run p. 3
- Connection examples for E-STOP, safety gates, light curtains and contactors p. 4, 5
- Mounting in a panel on a DIN rail p. 3
- Faults: earth faults, welded contacts, Power LED off p. 5
Good to know
- The unit ships with a bridge between Y1 and Y2 on the feedback control loop. p. 3
- Short detection across the inputs is not failsafe. p. 3
- Cables near the maximum length can delay the fuse trip by up to 2 minutes in the short test. p. 3
- With reed proximity switches, the peak inrush current on the input circuit must not overload the switch. p. 3
- Mount the unit in a panel; damp or dust can impair its function. p. 1
Questions this manual answers
How do I reset the PNOZ X8P after an earth fault on the DC version?
Remove the cause of the fault and switch off the operating voltage for about 1 minute. p. 5
Why is the Power LED off on my PNOZ X8P?
A short circuit or loss of the supply voltage. p. 5
Can the PNOZ X8P be used with a light curtain?
Yes. The manual states it suits non-contact barriers such as light curtains because a dynamic start is possible. p. 1
What fuse goes before the PNOZ X8P output contacts?
A 10 A quick or 6 A slow acting fuse, to keep the contacts from welding. p. 3
Why won't my PNOZ X8P reactivate after an E-STOP?
If contacts have welded, no further activation is possible after the input circuit opens. p. 5
The whole text · 3 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


