The text of a spec sheet · part 1 of 1

PNOZ X9 E-STOP relays, safety gate monitors, Up to PL e of EN ISO 13849-1, pages 1 to 8

Pages 1 to 8 of 8

The original document is the PDF (435 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Pilz PNOZ-X9

Page 1

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 ` Safety gates ` Light barriers

Unit features ` Positive-guided relay outputs: – 7 safety contacts (N/O), instantaneous – 2 auxiliary contacts (N/C), instantaneous ` 2 semiconductor outputs ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button – Light barriers ` LED indicator for: – Switch status channel 1/2 – Supply voltage – Reset circuit – Input circuits ` Semiconductor output signals: – Supply voltage is present – Switch status channel 1/2 ` See order reference for unit types

Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals

PNOZ X9

Safety features The relay meets the following safety requirements: ` The circuit is redundant with built-in self-monitoring. ` The safety function remains effective in the case of a component failure. ` The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. ` The tranformer is short circuitproof. An electronic fuse is used on a DC supply.

‹ Unit description The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with ` E-STOP pushbuttons

‹

‹

Block diagram

B1 B2

= =

S11 S12 S21 S22

Input

Input

S52

S33 S34

S37

Input

Reset/ Start

Reset/ Start

13 23 33 43 53 63 73 81 91

K1

K2 Power

= ~ A1 A2

Feedback

0 V 24 V

K3

Y1 Y2 Y30 Y31 Y32 Y35

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

14 24 34 44 54 64 74 82 92

NSG-D-2-037-2009-04

Page 2

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Function description ` Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ` Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit and, with a monitored reset, in the reset circuit too.

` Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects – earth faults in the reset and input circuit, – short circuits in the input circuit and, with a monitored reset, in the reset circuit too, – shorts between contacts in the input circuit. ` Automatic start: Unit is active once the input circuit has been closed.

` Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ` Monitored reset: Unit is active once – the input circuit is closed and then the reset circuit is closed and opened again. – the reset circuit is closed and then opened again once the input circuit is closed. ` Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.

Timing diagram 1

2 a b

3 a b

POWER Reset/Start Input Output safe Output aux. Out semi RUN Out semi CH t1 t2 t1 t1 t2 t2 t1 t2 t1 t1 t2 t2 t3

Key ` Power: Supply voltage ` Reset/start: Reset circuit S33-S34 ` Input: Input circuits S11-S12, S21S22, S52 ` Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74

` Output aux: Auxiliary contacts 8182, 91-92 ` Out semi RUN: Semiconductor output supply voltage Y35 ` Out semi CH: Semiconductor output switch status Y32 ` c: Automatic reset ` d: Manual reset

` e: Monitored reset ` a: Input circuit closes before reset circuit ` b: Reset circuit closes before input circuit ` t1: Switch-on delay ` t2: Delay-on de-energisation ` t3: Recovery time

` Calculation of the max. cabling runs lmax in the input circuit:

` Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads.

Wiring Please note: ` Information given in the “Technical details” must be followed. ` Outputs 13-14, 23-24, 33-34, 4344, 53-54, 63-64, 73-74 are safety contacts, outputs 81-82, 91-92 are auxiliary contacts (e.g. for display). ` To prevent contact welding, a fuse should be connected before the output contacts (see technical details).

Imax =

Rlmax Rl / km

Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km ` Use copper wire that can withstand 60/75 °C.

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

NSG-D-2-037-2009-04

-2

Page 3

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Preparing for operation ` Supply voltage Supply voltage

AC

DC A1 A2

L1 N

B1

L+

B2

PE

B2

L-

` Input circuit Input circuit E-STOP without detection of shorts across contacts

Single-channel

Dual-channel S11

S1

S11

S21

S12

S21

S22

S52

S22

E-STOP with detection of shorts across contacts

S12 S52

S11

Safety gate without detection of shorts across contacts S11

S11

S21

S52

S22 S12

S1

S11

S21

S12

S22

S21

S52

S22

S1

S1

S1

S2

S12 S52

Safety gate with detection of shorts across contacts

S11

S11 S12

S52

S21

S1

S2

S22

Light barrier with detection of shorts across contacts via ESPE

24 V DC S21 S22

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

S12 S52

GND

NSG-D-2-037-2009-04

Page 4

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 ` Reset circuit Reset circuit

E-STOP/safety gate wiring (single and dual-channel, without shorts across contacts)

Automatic reset

Manual reset

E-STOP/safety gate wiring (dual-channel, with shorts across contacts)

S33

S12

S34

S34 S3

S3

S33

S12

S34

S34

Monitored reset

S3

S3

S33 S34

S12 S34

Y1

Y1

S37

S37

` Feedback loop Feedback loop Contacts from external contactors

Y1 Y2 13 (23, 33) 14 (24, 34)

K5

K6 K5

L1 N

K6

` Semiconductor output

Y31

24 V DC

Y32

SPS Input

Y30

0V

` Key S1/S2 S3

E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

NSG-D-2-037-2009-04

-4

Page 5

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Terminal configuration

S11 S12 S12 S21 S22

S33 S34 Y1 Y2 S52 S11

A1 B1 13 23 33 43

53 63 73 81 91

POWER CH. 1 IN

PNOZ X9

13 23 33 43 53 63 73

81 91

14 24 34 44 54 64 74

82 92

64 74 82 92

/B2 A2

CH. 2 IN START CH. 1 CH. 2

14 24 34 44 54 Y30 Y31 Y32 Y35 Y1 S37

Installation

Dimensions

121 (4.76")

` The safety relay should be installed in a control cabinet with a protection type of at least IP54. ` Use the notch on the rear of the unit to attach it to a DIN rail. ` Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle).

75 (2.95") 87 (3.42")

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

90 (3.54")

NSG-D-2-037-2009-04

Page 6

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9

This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit.

Service life graph D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A)

Notice

10 AC1: 230 V DC1: 24 V DC13: 24 V 1

AC1: 400 V

AC15: 230 V 0.1

10 100 D Schaltspielzahl x 103 GB Cycles x 103 F Nombre de manœuvres x 103

1000 10000 E Número de ciclos x 103 I Numero dei cicli di commutazione x 103 NL Aantal schakelingen x 103

Technical details Electrical data Supply voltage Supply voltage UB AC Supply voltage UB DC Voltage tolerance Power consumption at UB AC Power consumption at UB DC Frequency range AC Residual ripple DC Voltage and current at Input circuit DC: 24.0 V Reset circuit DC: 24.0 V Feedback loop DC: 24.0 V Number of output contacts Safety contacts (S) instantaneous: Auxiliary contacts (N/C): Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V Safety contacts: AC1 at 400 V Safety contacts: DC1 at 24 V Auxiliary contacts: AC1 at 240 V Auxiliary contacts: DC1 at 24 V Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V Safety contacts: DC13 at 24 V (6 cycles/min) Auxiliary contacts: AC15 at 230 V Auxiliary contacts: DC13 at 24 V (6 cycles/min) Contact material

24 V, 42 V, 100 - 120 V, 200 - 230 V 24 V -15 %/+10 % 11.0 VA 5.5 W 50 - 60 Hz 160 % 50.0 mA 100.0 mA 100.0 mA 7 2 Imin: 0.01 A , Imax: 8.0 A Pmax: 2000 VA Imin: 0.01 A , Imax: 5.00 A Pmax: 2000 VA Imin: 0.01 A , Imax: 8.0 A Pmax: 200 W Imin: 0.01 A , Imax: 8.0 A Pmax: 2000 VA Imin: 0.01 A , Imax: 8.0 A Pmax: 200 W Imax: 5.0 A Imax: 7.0 A Imax: 5.0 A Imax: 7.0 A AgSnO2 + 0.2 µm Au

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

NSG-D-2-037-2009-04

-6

Page 7

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Electrical data External contact fuse protection (IK = 1 kA) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: Auxiliary contacts: Blow-out fuse, slow Safety contacts: Auxiliary contacts: Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: Auxiliary contacts: Semiconductor outputs (short circuit proof) External supply voltage Voltage tolerance Max. overall cable resistance Rlmax input circuits, reset circuits single-channel at UB DC single-channel at UB AC dual-channel without detect. of shorts across contacts at UB DC dual-channel without detect. of shorts across contacts at UB AC dual-channel with detect. of shorts across contacts at UB DC dual-channel with detect. of shorts across contacts at UB AC Safety-related characteristic data PL in accordance with EN ISO 13849-1 Category in accordance with EN 954-1 SIL CL in accordance with EN IEC 62061 PFH in accordance with EN IEC 62061 SIL in accordance with IEC 61511 PFD in accordance with IEC 61511 tM in years Times Switch-on delay with automatic reset typ. with automatic reset max. with automatic reset after power on typ. with automatic reset after power on max. with manual reset typ. with manual reset max. on monitored reset with rising edge typ. on monitored reset with rising edge max. Delay-on de-energisation with E-STOP typ. with E-STOP max. with power failure typ. with power failure max. Recovery time at max. switching frequency 1/s after E-STOP after power failure Min. start pulse duration with a monitored reset with rising edge Simultaneity, channel 1 and 2 Supply interruption before de-energisation Environmental data EMC Vibration to EN 60068-2-6 Frequency Amplitude Climatic suitability

10 A 10 A 6A 6A 6A 6A 24.0 V DC,20 mA 24.0 V DC -20 %/+20 %

45 Ohm 45 Ohm 90 Ohm 90 Ohm 15 Ohm 15 Ohm PL e (Cat. 4) Cat. 4 SIL CL 3 2.31E-09 SIL 3 2.03E-06 20

200 ms 250 ms 220 ms 300 ms 200 ms 250 ms 150 ms 220 ms 20 ms 30 ms 170 ms 250 ms 50 ms 300 ms 50 ms 150 ms 35 ms EN 60947-5-1, EN 61000-6-2 10 - 55 Hz 0.35 mm EN 60068-2-78

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

NSG-D-2-037-2009-04

Page 8

E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Environmental data Airgap creepage in accordance with EN 60947-1 Pollution degree Overvoltage category Rated insulation voltage Rated impulse withstand voltage Ambient temperature Storage temperature Protection type Mounting (e.g. cabinet) Housing Terminals Mechanical data Housing material Housing Front Cross section of external conductors with screw terminals 1 core flexible 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals Dimensions Height Width Depth Weight

2 III 250 V 4.0 kV -10 - 55 °C -40 - 85 °C IP54 IP40 IP20

PPO UL 94 V0 ABS UL 94 V0 0.20 - 4.00 mm² , 24 - 10 AWG 0.20 - 2.50 mm² , 24 - 14 AWG 0.20 - 2.50 mm² , 24 - 14 AWG 0.60 Nm 87.0 mm 90.0 mm 121.0 mm 750 g

The standards current on 06/04 apply.

Conventional thermal current Number of contacts 1 2 3 4 5 6 7

Ith (A) at UB DC 8.00 A 8.00 A 8.00 A 7.00 A 6.00 A 5.50 A 5.00 A

Ith (A) at UB AC 8.00 A 5.60 A 4.60 A 4.00 A 3.50 A 3.20 A 3.00 A

Order reference Type PNOZ X9 PNOZ X9 PNOZ X9 PNOZ X9

Features 24 VAC/DC 42 VAC 110 - 120 VAC 220 - 230 VAC

24 VDC 24 VDC 24 VDC

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de

Terminals Screw terminals Screw terminals Screw terminals Screw terminals

Order no. 774 609 774 601 774 605 774 606

NSG-D-2-037-2009-04

-8