Spec sheet · Pilz
Safe timer relays, Delay-on energisation, PZA
Spec sheet7 pagesPDF 409 KB
Data sheet for the Pilz PZA safe timer relay (delay-on energisation) used with PNOZ safety relays and PST gate monitors.
Covers · 1 model
The models it covers
Summary
What is in it
The Pilz data sheet for the PZA safe timer relay with delay-on energisation, used to unlock an interlock with a delay alongside PNOZ safety relays or PST safety gate monitors. It covers unit and safety features, approvals, the block and timing diagrams, wiring notes, preparing for operation, terminal configuration, installation and dimensions, the service life graph, full electrical, timing, environmental and mechanical data, and order numbers for each supply voltage and time range.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Pilz data sheet NSG-D-2-084-2009-10 for the PZA safe timer relay with delay-on energisation. It explains how the timer works, how to wire and mount it, and lists the technical details and order numbers of its twelve versions.
- What it is
- Delay-on energisation safety timer relay for unlocking an interlock with delay p. 1
- Outputs
- Positive-guided relays: 1 safety contact (N/O) and 2 auxiliary contacts (N/C), all delay-on energisation p. 1
- Delay setting
- 12 time values, set with a rotary switch p. 1
- Delay ranges
- 30.00 s to 300.00 s (774020, 774021, 774023, 774026, 774029); 60.00 s to 600.00 s (774028); 3.00 s to 30.00 s (774030, 774031, 774035, 774040); 0.30 s to 3.00 s (774038, 774041) p. 6
- Versions
- 24 VAC, 42 VAC, 110 - 120 VAC, 230 VAC and 24 VDC supply; screw terminals; order no. 774 020 to 774 041 p. 7
- Power consumption
- 4.5 VA (774020, 774021, 774023, 774026, 774031, 774035, 774038, 774040) or 3.0 W (774028, 774029, 774030, 774041) p. 5
- Base units
- PNOZ series safety relays and PST series safety gate monitors p. 1
- Contact rating
- Imin 0.01 A, Imax 6.0 A; Pmax 1500 VA or 150 W p. 5
- Contact material
- AgSnO2 + 0.2 µm Au p. 5
- Terminals
- Input circuit A1-A2, feedback loop Y1-Y2, safety contact 17-18, auxiliary contacts 25/26 and 35-36 p. 2, 4
- LED indicators
- Switch status channel 1/2 and supply voltage p. 1
- Mounting
- 35 mm DIN rail, in a control cabinet of at least IP54 p. 4
- Dimensions (drawing)
- 121 mm (4.76"), 87 mm (3.42") and 45 mm (1.77") p. 4
- Weight
- 260 g (774028, 774029, 774030, 774041) or 350 g (774020, 774021, 774023, 774026, 774031, 774035, 774038, 774040) p. 7
What this sheet walks you through
- How the delay-on energisation timer works p. 2
- Reading the timing diagram and its fault cases p. 2
- Calculating the maximum cable run in the input circuit p. 2
- Connecting the supply voltage and the feedback loop p. 3
- Mounting the unit on a DIN rail p. 4
Good to know
- The data sheet is meant for configuration only; installation and operation follow the operating instructions supplied with the unit. p. 5
- A fuse should be connected before the output contacts to prevent contact welding. p. 2
- On 24 VDC, shorts between the input circuit and feedback loop, or earth faults in the feedback loop, can damage the unit. p. 2
- The EN 954-1 category reached depends on the base unit, and the PZA may not exceed it. p. 1
- Use copper wire rated for 60/75 °C. p. 2
Questions this sheet answers
What does the Pilz PZA do?
It is a delay-on energisation timer relay that unlocks an interlock after a delay, used with a PNOZ safety relay or a PST safety gate monitor. p. 1
What delay times can the PZA be set to?
Twelve time values on a rotary switch; the range depends on the version, for example 30.00 s to 300.00 s or 0.30 s to 3.00 s. p. 1, 6
What contacts does the PZA have?
One N/O safety contact and two N/C auxiliary contacts; the auxiliary contacts are meant for uses such as a display. p. 1, 2
What happens when the PZA input circuit is interrupted?
The safety contact opens and the auxiliary contacts close. p. 2
How is the PZA mounted?
On a vertical 35 mm DIN rail, held with a fixing element such as a retaining bracket, inside a cabinet of at least IP54. p. 4
The whole text · 1 part