Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Safe timer relays, Delay-on energisation, PZA

Spec sheet · Pilz

Safe timer relays, Delay-on energisation, PZA

Spec sheet7 pagesPDF 409 KB

Data sheet for the Pilz PZA safe timer relay (delay-on energisation) used with PNOZ safety relays and PST gate monitors.

Download the PDF409 KB

Covers · 1 model

The models it covers

Summary

What is in it

The Pilz data sheet for the PZA safe timer relay with delay-on energisation, used to unlock an interlock with a delay alongside PNOZ safety relays or PST safety gate monitors. It covers unit and safety features, approvals, the block and timing diagrams, wiring notes, preparing for operation, terminal configuration, installation and dimensions, the service life graph, full electrical, timing, environmental and mechanical data, and order numbers for each supply voltage and time range.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Pilz data sheet NSG-D-2-084-2009-10 for the PZA safe timer relay with delay-on energisation. It explains how the timer works, how to wire and mount it, and lists the technical details and order numbers of its twelve versions.

What it is
Delay-on energisation safety timer relay for unlocking an interlock with delay p. 1
Outputs
Positive-guided relays: 1 safety contact (N/O) and 2 auxiliary contacts (N/C), all delay-on energisation p. 1
Delay setting
12 time values, set with a rotary switch p. 1
Delay ranges
30.00 s to 300.00 s (774020, 774021, 774023, 774026, 774029); 60.00 s to 600.00 s (774028); 3.00 s to 30.00 s (774030, 774031, 774035, 774040); 0.30 s to 3.00 s (774038, 774041) p. 6
Versions
24 VAC, 42 VAC, 110 - 120 VAC, 230 VAC and 24 VDC supply; screw terminals; order no. 774 020 to 774 041 p. 7
Power consumption
4.5 VA (774020, 774021, 774023, 774026, 774031, 774035, 774038, 774040) or 3.0 W (774028, 774029, 774030, 774041) p. 5
Base units
PNOZ series safety relays and PST series safety gate monitors p. 1
Contact rating
Imin 0.01 A, Imax 6.0 A; Pmax 1500 VA or 150 W p. 5
Contact material
AgSnO2 + 0.2 µm Au p. 5
Terminals
Input circuit A1-A2, feedback loop Y1-Y2, safety contact 17-18, auxiliary contacts 25/26 and 35-36 p. 2, 4
LED indicators
Switch status channel 1/2 and supply voltage p. 1
Mounting
35 mm DIN rail, in a control cabinet of at least IP54 p. 4
Dimensions (drawing)
121 mm (4.76"), 87 mm (3.42") and 45 mm (1.77") p. 4
Weight
260 g (774028, 774029, 774030, 774041) or 350 g (774020, 774021, 774023, 774026, 774031, 774035, 774038, 774040) p. 7

What this sheet walks you through

  • How the delay-on energisation timer works p. 2
  • Reading the timing diagram and its fault cases p. 2
  • Calculating the maximum cable run in the input circuit p. 2
  • Connecting the supply voltage and the feedback loop p. 3
  • Mounting the unit on a DIN rail p. 4

Good to know

  • The data sheet is meant for configuration only; installation and operation follow the operating instructions supplied with the unit. p. 5
  • A fuse should be connected before the output contacts to prevent contact welding. p. 2
  • On 24 VDC, shorts between the input circuit and feedback loop, or earth faults in the feedback loop, can damage the unit. p. 2
  • The EN 954-1 category reached depends on the base unit, and the PZA may not exceed it. p. 1
  • Use copper wire rated for 60/75 °C. p. 2

Questions this sheet answers

What does the Pilz PZA do?

It is a delay-on energisation timer relay that unlocks an interlock after a delay, used with a PNOZ safety relay or a PST safety gate monitor. p. 1

What delay times can the PZA be set to?

Twelve time values on a rotary switch; the range depends on the version, for example 30.00 s to 300.00 s or 0.30 s to 3.00 s. p. 1, 6

What contacts does the PZA have?

One N/O safety contact and two N/C auxiliary contacts; the auxiliary contacts are meant for uses such as a display. p. 1, 2

What happens when the PZA input circuit is interrupted?

The safety contact opens and the auxiliary contacts close. p. 2

How is the PZA mounted?

On a vertical 35 mm DIN rail, held with a fixing element such as a retaining bracket, inside a cabinet of at least IP54. p. 4

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7

The file

Revision and size

RevisionNSG-D-2-084-2009-10
PublisherPilz GmbH & Co. KG
Pages7
PDF409 KB
TextText from the PDF itself.

The first pages · 4 of 7

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 7
Page 2
Page 2of 7
Page 3
Page 3of 7
Page 4
Page 4of 7

More documents · 1

For the same models