Page 1 of PZA Operating instructions

Manual · Pilz

PZA Operating instructions

Manual12 pagesPDF 589 KB

Multilingual operating instructions for the Pilz PZA 3/30/300/600 delay-on energisation timer relay used in safety circuits.

Download the PDF589 KB

Covers · 1 model

The models it covers

Summary

What is in it

Pilz operating instructions, in German, English, French, Spanish, Italian and Dutch, for the PZA 3/30/300/600 timer relay, a delay-on energisation unit for delayed unlocking of guards, used with PNOZ safety relays and PST safety gate monitors. They cover safety regulations, authorized applications, the unit description and function, installation, operation, an application example with a PNOZ 6, faults, technical data, relay service life and dimensions.

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operating instructions 18 219-05 for the Pilz PZA 3/30/300/600 delay-on energisation timer relay, printed in several languages. They cover intended use, how the timer works, installation and start-up, a connection example with a PNOZ 6, fault behavior and the technical data.

Read for this summary: pages 1 to 6 of 12.

What it is
Delay-on energisation timer relay in a P-97 housing, in several AC versions and one DC version p. 1
Outputs
One safety contact (N/O) 17-18 and two auxiliary contacts (N/C) 25-26 and 35-36, positive-guided p. 1, 2
Supply voltage
AC: 24 V, 42 V, 110 - 120 V, 230 V; DC: 24 V; tolerance -15 % ... +10 % p. 4
Delay times
12 steps: PZA 3 0.3 to 3.0 s; PZA 30 3 to 30 s; PZA 300 30 to 300 s; PZA 600 60 to 600 s; repetition accuracy +/-1 % p. 4
Power consumption
AC: 4.5 VA; DC: 3 W p. 4
Contact ratings
AC1: 240 V/0.01 ... 6 A/1500 VA; DC1: 24 V/0.01 ... 6 A/150 W; AC15: 230 V/4 A; DC13: 24 V/3 A p. 4
LEDs
"power" lights with operating voltage; "out" lights when the delay ends and the safety contact closes p. 3
Input circuit
Operating voltage on terminals A1 (+) and A2 (-); applying it starts the delay p. 2
Feedback loop
Y1-Y2, bridged or wired to external contactors/relays; 50.0 mA p. 2, 4
External contact fuse
6 A quick acting or 4 A slow acting; 24 V AC/DC: 4 A, characteristic B/C p. 4
Mounting
DIN rail, in a panel of at least IP 54; housing IP 40, terminals IP 20 p. 2, 4
Wire size
1 flexible core 0.20 ... 4.00 mm2 (24-10 AWG); terminal screw torque 0.6 Nm p. 4
Weight
AC: 350 g, DC: 260 g p. 4
Contact material
AgSnO2 + 0.2 µm Au p. 4

What this manual walks you through

  • Setting the delay and starting up the timer relay p. 2
  • The operating sequence of contacts and LEDs p. 2, 3
  • Connection example with a PNOZ 6 safety gate monitor p. 3
  • Mounting the unit on a DIN rail p. 2
  • What happens on an internal fault p. 3
  • Service life of the output relays (graph) p. 5

Good to know

  • Only contact 17-18 is a safety contact; 25-26 and 35-36 are auxiliary contacts, for example for monitoring. p. 2
  • A fuse must be connected before the output contacts to prevent contact welding. p. 2
  • Connect the unit only as in the connection example and leave unlabelled terminals unconnected. p. 3
  • Output contacts with capacitive and inductive loads need adequate protection and suppression. p. 1
  • The EN 954-1 category reached depends on the base unit, and the PZA may not exceed it. p. 1

Questions this manual answers

What is the difference between the PZA 3, PZA 30, PZA 300 and PZA 600?

The delay range: 0.3 to 3.0 s, 3 to 30 s, 30 to 300 s and 60 to 600 s, each in 12 steps. p. 4

What happens if the PZA timer relay has a fault?

The safety contact stays open, the auxiliary contacts stay closed and the time period defaults to infinity. p. 3

What do the power and out LEDs on the PZA show?

"power" lights when operating voltage is applied; "out" lights once the set time has elapsed and the safety contact has closed. p. 3

How do I put the PZA into operation?

Turn the rotary switch to the delay with a screwdriver, bridge Y1-Y2 or connect external contactors, then connect the operating voltage to A1 (+) and A2 (-). p. 2

Which Pilz units is the PZA used with?

Safety relays from the PNOZ range and safety gate monitors from the PST range. p. 1

The whole text · 2 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12

The file

Revision and size

Revision18 219-05, 2010-08
PublisherPilz GmbH & Co. KG
Pages12
PDF589 KB
TextText from the PDF itself.

The first pages · 3 of 12

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 12
Page 2
Page 2of 12
Page 3
Page 3of 12

More documents · 1