The text of a manual · part 5 of 8
TM-1020 Series Progressive Scan Shutter Cameras Operation Manual, pages 37 to 45
Pages 37 to 45 of 72
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PULNiX TM-1020 and SAIC TM-1020
Page 37
Page 29 Operation 3.10 Camera Timing Charts Model: TM-1020-15
Operation Mode: 15 fps
Master Clock: 40.0 MHz, M= 25 nsec Pixel Clock: 20.0 MHz, P= 50 nsec
1. Pixel Clock and Digital Data Pixel Clock
A
Data (B) Tcd
Tdc
Thd
Tcd: Clock to Data Ready Tdc: Data Ready to Next Clock Thd: Data Hold Time
Tcd = 19.00 nsec, Tdc = 31.00 nsec, Thd = 11.00 nsec.
2. Horizontal Signals fHD = [ 15.75 KHz] tHD = [ 63.50 µsec]
External HD A [ 10P],( 0.50 µs) Internal HD
B [ 1174P], ( 58.8µs) C [ 1270 P], ( 63.5µs)
LDV
D [ 262P], ( 13.1µs) E [ 1008 P], ( 50.3µs) F [ 1270P], ( 63.5µs)
G [ 0P], ( 4.2 ns) Digital Data I [1006P], ( 50.3µs) H [ 268P], ( 13.4µs) Analog Video N [ 24P], (1.21 µs)
K [ 1000P], (50µs) J [ 250 P], ( 12.5µs)
M [ 76P], ( 3.8µs) L [ 20P], ( 1.01µs)
TM-1020 Series Progressive Scan Shutter Cameras
Page 38
Page 30 Operation
Model: TM-1020
Operation Mode: 15 Frames/Second
Master Clock: 40 MHz, M= 25 nsec Pixel Clock: 20 MHz, P = 50 nsec
Horizontal Frequency: 15.748 KHz 1H = 63.50 µsec
3. External Reset Timing External VD A [1050 H], (66.68 msec)
B [0 H], (470.0 ns) C [9 H], (572.0 µs)
Internal VD
D [1041 H], (66.10 ms) E [ 1050 H], (66.68 ms) G [32 H], (2.030 ms)
FDV
H [1018 H], (64.64 ms)
F [0 H], (36 ns) J [32 H], (2.040 ms) Digital Data
K [1018 H], (64.64 ms)
I [0 H], (260.0 ns) M [29 H], (1.880 ms) Analog Video
O [1018 H], (64.64 ms)
L [0 H], (100 ns)
P [3 H], (190.5 µs)
N [3 H], (190.5 µs)
4. Async Reset Timing VINIT Trigger
Q [1 H], (68.00 µs)
R [9 H], (572.0 µs)
Internal VD S [1041 H], (66.10 ms) T [ 1050 H], (66.68 ms) V [32 H], (2.040 ms) FDV U [0 H], (32.00 ns) X [32 H], (2.040 ms) Digital Data Y [1018 H], (64.64 ms)
W [9 H], (568.0 µs) AA [29 H], (1.880 ms) Analog Video
CC [1018 H], (64.64 ms)
Z [0 H], (5 µs)
DD [3 H], (190.5 µs) BB [3 H], (190.5 µs)
TM-1020 Series Progressive Scan Shutter Cameras
Page 39
Page 31 Operation
Model: TM-1020-30
Operation Mode: 30 fps
Master Clock: 80.0 MHz, M= 12.5 nsec Pixel Clock: 40.0 MHz, P= 25 nsec 1. Pixel Clock and Digital Data Pixel Clock
A
Data (B) Tcd
Tdc
Thd
Tcd: Clock to Data Ready Tdc: Data Ready to Next Clock Thd: Data Hold Time
Tcd = 9.0 nsec, Tdc = 16.0 nsec, Thd = 6.00 nsec. 2. Horizontal Signals fHD = [ 31.50 KHz] tHD = [ 31.75 µsec]
External HD
A [ 1032 P], (25.8µs)
Internal HD
B [1270 P], (31.75 µs) LDV
C [262 P], (6.55 µs) D [1008 P], (25.2 µs) E [1270 P], (31.75 µs)
Digital Data G [1088 P], (25.2 µs) F [262 P], (6.55 µs) Analog Video H [70 P], (1.75 µs)
J [1008 P], (25.2 µs)
K [67 P], (1.675 µs)
I [192 P], (4.8µs)
TM-1020 Series Progressive Scan Shutter Cameras
Page 40
Page 32 Operation
Model: TM-1020-30
Operation Mode: 30 Frames/Second
Master Clock: 80 MHz, M= 12.5 nsec Pixel Clock: 40 MHz, P = 25 nsec
Horizontal Frequency: 31.50 KHz 1H = 31.75 sec
3. External Reset Timing External VD A [1050 H], (33.34 msec) B [0, H], (0 us) Internal VD
C [9 H], (285.75 µs) D [1041 H], (33.05 ms) E [1050 H], (33.33 ms) F [32 H], (1.02 ms)
FDV
G [1018 H], (32.32 ms) H [32 H], (1.02 ms) Digital Data I [1018 H), (32.32 ms) Analog Video
J [29 H], (0.92 ms)
K [3 H], (97 ns)
M [1018 H], (32.32 ms)
L [3 H], (97 µs)
4. Async Shutter 0 Reset Timing VINIT Trigger
N [1 H], (31.75 µs) Internal VD
O [9 H], (286 µs) P [1041 H], (33.05 ms) Q [ 1050 H], (33.34 ms) R [32 H], (1.02 ms)
FDV
S [32 H], (1.02 ms) Digital Data T [1018], (32.32 ms) U [29 H], (0.94 ms) Analog Video V [3 H], (97 µs)
X [1018 H], (32.32 ms) W [3 H], (97 µs)
TM-1020 Series Progressive Scan Shutter Cameras
Page 41
Page 33 Operation 3.10.1 Pixel Clock Locking (optional)1 External Clock
External HD
Internal HD with PLL PLL jitter Pixel clock
VCO voltage swing Pixel clock
For multiple-camera applications such as 2D or 3D measurement, multiple-camera inspection, a parallel digital data input capability is important. The high resolution and precision measurement requires that camera data be consistent with each other and free from PLL jitter. This is especially important for digital output multiplexing. The TM-1020 series has an optional capability for pixel clock locking. It takes RS-422 (differential) external clock and H and V reset sync (TTL or RS-422). By doing this, each camera’s digital data is in-phase with the pixel clock (data clock) for multiplexing or parallel input to a frame grabber.
3.11 Serial Communication Kit •
LVDS/RS-422 Version The LVDS/RS-422 version’s functions can be controlled by a PC via RS232C communication using the CS-232E serial communication kit. This kit consists of the RS232B-12 cable, software disk, and quick-start card. The software disk contains setup files for the graphical user interface (GUI) program. Please refer to the AccuPiXEL Series Camera-Control Software manual for information on the GUI.
•
Camera Link The Camera Link version’s control software is also included in the AccuPiXEL Camera Control software.
1. Pixel clock locking option not available at time of publishing. Please check with PULNiX for option availability.
TM-1020 Series Progressive Scan Shutter Cameras
Page 42
Page 34 LVDS-Version Camera RS-232 Commands
4
LVDS-Version Camera RS-232 Commands The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:” and the end character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode, send the command :SA9”CR” to the camera. The following table contains RS-232 commands that can be used to control the camera. TABLE 7.
1
RS-232 Command List
First Character
Second Character
Third Character
“S” (shutter)
“M” (Manual)
“0” - “9” Mode
ACK
Manual Shutter Mode
“A” (ASYNC)
“0” - “8” Mode
ACK
Async Shutter Mode
“9” (Pulse Width Mode)
ACK
Async Pulse Width Mode
Response
Functions
2
“G” (Gain)
“M”
“00” - “FF”
ACK
Gain Control
3
“V” (A/D Vref)
“T” (Top)
“00” - “FF”
ACK
Vtop reference setting
“B” (Bottom)
“00” - “FF”
ACK
Vbtm reference setting
“P” (Page)
“0” - “6”
ACK
Write current setting to Page EEPROM
“U” (User)
“A” - “D”
ACK
Write current setting to User EEPROM
“S” (System)
“A” - “D”
ACK
Write current setting to System EEPROM
“P” (Page)
“0” - “6”
ACK
Restore setting from Page EEPROM
“U” (User)
“A” - “D”
ACK
Restore setting from User EEPROM
“S” (System)
“A” - “D”
ACK
Restore setting from System EEPROM
“N” (kNee)
“0” - “9”
ACK
Load Preset Knee Table
“P” (Page)
“0” - “6”
ACK
ACK + “P” + (“9” - “F”) + 16 bytes
“U” (User)
“A” - “D”
ACK
ACK + “U” + (“A” - “D”) + 6 bytes
“S” (System)
“A” - “D”
ACK
ACK + “S” + (“A” - “D”) + (6 bytes)
“R” (Current)
ACK
ACK + “RR” + 16 bytes
“X” (Execute)
ACK
Set Camera with loaded data
“D” (Date)
info
Report CPU program version
4
5
6
“W” (Write)
“L”
“R” (Report)
TM-1020 Series Progressive Scan Shutter Cameras
Page 43
Page 35 LVDS-Version Camera RS-232 Commands
7
First Character
Second Character
Third Character
“T” (Table)
“N” (kNee)
X1 + Y1 + X2 + Y2
Response ACK
X1, Y1, X2, Y2: “00 - FF” ACK
“L” (Linear)
ACK
8
Note:
“N”
“0” or “1”
(X1, Y1) coordinate for knee 1 (X2, Y2) coordinate for knee 2
“M” (Gamma) “C” (Switch A, B Table)
Functions
ACK
“0” (Normal)
ACK
Normal Scan Formal
“1” (Binning)
ACK
Double Speed Binning
One byte of data consists of two ASCII codes. For example, 0x3A is “3” (0x33). “A” (0x41) x <ACK> is 0x06. <NAK> is 0x15. This command’s basic protocol is the same for Camera Link model cameras.
TM-1020 Series Progressive Scan Shutter Cameras
Page 44
Page 36 Troubleshooting
5
Troubleshooting 5.1 Problems and Solutions Following are troubleshooting tips for common problems. In general, problems can easily be solved by following these instructions. If the following remedies fail to offer a solution to your problems, please contact a PULNiX representative.
5.1.1 Symptom: No Video Remedies: Check that the following are properly connected and operational.
•
Power supplies
•
Power cables
•
Main power source
•
Shutter control
•
Async mode
•
Lens
•
Digital output cable
•
Analog video cable
5.1.2 Symptom: Dark Video Remedies: Check that the following are properly connected and operational.
•
Shutter selection
•
Iris opening on the lens
5.1.3 Symptom: Non-synchronized Video Remedies: Check that the following are properly connected and operational.
•
Proper mode output
•
Frame grabber software camera selection
TM-1020 Series Progressive Scan Shutter Cameras
Page 45
Page 37 Troubleshooting 5.2 Information and Support Resources For further information and support: Phone:
(408) 747-0300 (800) 445-5444 (800) 3-PULNIX (24-hour message access)
Fax:
(408) 747-0660
E-mail:
imaging@pulnix.com
Mail:
PULNiX America Inc. Sales Department 1330 Orleans Drive Sunnyvale, CA 94089 ATTN: Video Applications
Web Site:
www.pulnix.com
TM-1020 Series Progressive Scan Shutter Cameras