Page 37

Page 29 Operation 3.10 Camera Timing Charts Model: TM-1020-15

Operation Mode: 15 fps

Master Clock: 40.0 MHz, M= 25 nsec Pixel Clock: 20.0 MHz, P= 50 nsec

1. Pixel Clock and Digital Data Pixel Clock

A

Data (B) Tcd

Tdc

Thd

Tcd: Clock to Data Ready Tdc: Data Ready to Next Clock Thd: Data Hold Time

Tcd = 19.00 nsec, Tdc = 31.00 nsec, Thd = 11.00 nsec.

2. Horizontal Signals fHD = [ 15.75 KHz] tHD = [ 63.50 µsec]

External HD A [ 10P],( 0.50 µs) Internal HD

B [ 1174P], ( 58.8µs) C [ 1270 P], ( 63.5µs)

LDV

D [ 262P], ( 13.1µs) E [ 1008 P], ( 50.3µs) F [ 1270P], ( 63.5µs)

G [ 0P], ( 4.2 ns) Digital Data I [1006P], ( 50.3µs) H [ 268P], ( 13.4µs) Analog Video N [ 24P], (1.21 µs)

K [ 1000P], (50µs) J [ 250 P], ( 12.5µs)

M [ 76P], ( 3.8µs) L [ 20P], ( 1.01µs)

TM-1020 Series Progressive Scan Shutter Cameras

Page 38

Page 30 Operation

Model: TM-1020

Operation Mode: 15 Frames/Second

Master Clock: 40 MHz, M= 25 nsec Pixel Clock: 20 MHz, P = 50 nsec

Horizontal Frequency: 15.748 KHz 1H = 63.50 µsec

3. External Reset Timing External VD A [1050 H], (66.68 msec)

B [0 H], (470.0 ns) C [9 H], (572.0 µs)

Internal VD

D [1041 H], (66.10 ms) E [ 1050 H], (66.68 ms) G [32 H], (2.030 ms)

FDV

H [1018 H], (64.64 ms)

F [0 H], (36 ns) J [32 H], (2.040 ms) Digital Data

K [1018 H], (64.64 ms)

I [0 H], (260.0 ns) M [29 H], (1.880 ms) Analog Video

O [1018 H], (64.64 ms)

L [0 H], (100 ns)

P [3 H], (190.5 µs)

N [3 H], (190.5 µs)

4. Async Reset Timing VINIT Trigger

Q [1 H], (68.00 µs)

R [9 H], (572.0 µs)

Internal VD S [1041 H], (66.10 ms) T [ 1050 H], (66.68 ms) V [32 H], (2.040 ms) FDV U [0 H], (32.00 ns) X [32 H], (2.040 ms) Digital Data Y [1018 H], (64.64 ms)

W [9 H], (568.0 µs) AA [29 H], (1.880 ms) Analog Video

CC [1018 H], (64.64 ms)

Z [0 H], (5 µs)

DD [3 H], (190.5 µs) BB [3 H], (190.5 µs)

TM-1020 Series Progressive Scan Shutter Cameras

Page 39

Page 31 Operation

Model: TM-1020-30

Operation Mode: 30 fps

Master Clock: 80.0 MHz, M= 12.5 nsec Pixel Clock: 40.0 MHz, P= 25 nsec 1. Pixel Clock and Digital Data Pixel Clock

A

Data (B) Tcd

Tdc

Thd

Tcd: Clock to Data Ready Tdc: Data Ready to Next Clock Thd: Data Hold Time

Tcd = 9.0 nsec, Tdc = 16.0 nsec, Thd = 6.00 nsec. 2. Horizontal Signals fHD = [ 31.50 KHz] tHD = [ 31.75 µsec]

External HD

A [ 1032 P], (25.8µs)

Internal HD

B [1270 P], (31.75 µs) LDV

C [262 P], (6.55 µs) D [1008 P], (25.2 µs) E [1270 P], (31.75 µs)

Digital Data G [1088 P], (25.2 µs) F [262 P], (6.55 µs) Analog Video H [70 P], (1.75 µs)

J [1008 P], (25.2 µs)

K [67 P], (1.675 µs)

I [192 P], (4.8µs)

TM-1020 Series Progressive Scan Shutter Cameras

Page 40

Page 32 Operation

Model: TM-1020-30

Operation Mode: 30 Frames/Second

Master Clock: 80 MHz, M= 12.5 nsec Pixel Clock: 40 MHz, P = 25 nsec

Horizontal Frequency: 31.50 KHz 1H = 31.75 sec

3. External Reset Timing External VD A [1050 H], (33.34 msec) B [0, H], (0 us) Internal VD

C [9 H], (285.75 µs) D [1041 H], (33.05 ms) E [1050 H], (33.33 ms) F [32 H], (1.02 ms)

FDV

G [1018 H], (32.32 ms) H [32 H], (1.02 ms) Digital Data I [1018 H), (32.32 ms) Analog Video

J [29 H], (0.92 ms)

K [3 H], (97 ns)

M [1018 H], (32.32 ms)

L [3 H], (97 µs)

4. Async Shutter 0 Reset Timing VINIT Trigger

N [1 H], (31.75 µs) Internal VD

O [9 H], (286 µs) P [1041 H], (33.05 ms) Q [ 1050 H], (33.34 ms) R [32 H], (1.02 ms)

FDV

S [32 H], (1.02 ms) Digital Data T [1018], (32.32 ms) U [29 H], (0.94 ms) Analog Video V [3 H], (97 µs)

X [1018 H], (32.32 ms) W [3 H], (97 µs)

TM-1020 Series Progressive Scan Shutter Cameras

Page 41

Page 33 Operation 3.10.1 Pixel Clock Locking (optional)1 External Clock

External HD

Internal HD with PLL PLL jitter Pixel clock

VCO voltage swing Pixel clock

For multiple-camera applications such as 2D or 3D measurement, multiple-camera inspection, a parallel digital data input capability is important. The high resolution and precision measurement requires that camera data be consistent with each other and free from PLL jitter. This is especially important for digital output multiplexing. The TM-1020 series has an optional capability for pixel clock locking. It takes RS-422 (differential) external clock and H and V reset sync (TTL or RS-422). By doing this, each camera’s digital data is in-phase with the pixel clock (data clock) for multiplexing or parallel input to a frame grabber.

3.11 Serial Communication Kit •

LVDS/RS-422 Version The LVDS/RS-422 version’s functions can be controlled by a PC via RS232C communication using the CS-232E serial communication kit. This kit consists of the RS232B-12 cable, software disk, and quick-start card. The software disk contains setup files for the graphical user interface (GUI) program. Please refer to the AccuPiXEL Series Camera-Control Software manual for information on the GUI.

•

Camera Link The Camera Link version’s control software is also included in the AccuPiXEL Camera Control software.

1. Pixel clock locking option not available at time of publishing. Please check with PULNiX for option availability.

TM-1020 Series Progressive Scan Shutter Cameras

Page 42

Page 34 LVDS-Version Camera RS-232 Commands

4

LVDS-Version Camera RS-232 Commands The LVDS-version camera can be controlled via RS-232 commands. The Start character is always “:” and the end character is always “CR” (return). For example, to set Asynchronous Pulse Width Mode, send the command :SA9”CR” to the camera. The following table contains RS-232 commands that can be used to control the camera. TABLE 7.

1

RS-232 Command List

First Character

Second Character

Third Character

“S” (shutter)

“M” (Manual)

“0” - “9” Mode

ACK

Manual Shutter Mode

“A” (ASYNC)

“0” - “8” Mode

ACK

Async Shutter Mode

“9” (Pulse Width Mode)

ACK

Async Pulse Width Mode

Response

Functions

2

“G” (Gain)

“M”

“00” - “FF”

ACK

Gain Control

3

“V” (A/D Vref)

“T” (Top)

“00” - “FF”

ACK

Vtop reference setting

“B” (Bottom)

“00” - “FF”

ACK

Vbtm reference setting

“P” (Page)

“0” - “6”

ACK

Write current setting to Page EEPROM

“U” (User)

“A” - “D”

ACK

Write current setting to User EEPROM

“S” (System)

“A” - “D”

ACK

Write current setting to System EEPROM

“P” (Page)

“0” - “6”

ACK

Restore setting from Page EEPROM

“U” (User)

“A” - “D”

ACK

Restore setting from User EEPROM

“S” (System)

“A” - “D”

ACK

Restore setting from System EEPROM

“N” (kNee)

“0” - “9”

ACK

Load Preset Knee Table

“P” (Page)

“0” - “6”

ACK

ACK + “P” + (“9” - “F”) + 16 bytes

“U” (User)

“A” - “D”

ACK

ACK + “U” + (“A” - “D”) + 6 bytes

“S” (System)

“A” - “D”

ACK

ACK + “S” + (“A” - “D”) + (6 bytes)

“R” (Current)

ACK

ACK + “RR” + 16 bytes

“X” (Execute)

ACK

Set Camera with loaded data

“D” (Date)

info

Report CPU program version

4

5

6

“W” (Write)

“L”

“R” (Report)

TM-1020 Series Progressive Scan Shutter Cameras

Page 43

Page 35 LVDS-Version Camera RS-232 Commands

7

First Character

Second Character

Third Character

“T” (Table)

“N” (kNee)

X1 + Y1 + X2 + Y2

Response ACK

X1, Y1, X2, Y2: “00 - FF” ACK

“L” (Linear)

ACK

8

Note:

“N”

“0” or “1”

(X1, Y1) coordinate for knee 1 (X2, Y2) coordinate for knee 2

“M” (Gamma) “C” (Switch A, B Table)

Functions

ACK

“0” (Normal)

ACK

Normal Scan Formal

“1” (Binning)

ACK

Double Speed Binning

One byte of data consists of two ASCII codes. For example, 0x3A is “3” (0x33). “A” (0x41) x <ACK> is 0x06. <NAK> is 0x15. This command’s basic protocol is the same for Camera Link model cameras.

TM-1020 Series Progressive Scan Shutter Cameras

Page 44

Page 36 Troubleshooting

5

Troubleshooting 5.1 Problems and Solutions Following are troubleshooting tips for common problems. In general, problems can easily be solved by following these instructions. If the following remedies fail to offer a solution to your problems, please contact a PULNiX representative.

5.1.1 Symptom: No Video Remedies: Check that the following are properly connected and operational.

•

Power supplies

•

Power cables

•

Main power source

•

Shutter control

•

Async mode

•

Lens

•

Digital output cable

•

Analog video cable

5.1.2 Symptom: Dark Video Remedies: Check that the following are properly connected and operational.

•

Shutter selection

•

Iris opening on the lens

5.1.3 Symptom: Non-synchronized Video Remedies: Check that the following are properly connected and operational.

•

Proper mode output

•

Frame grabber software camera selection

TM-1020 Series Progressive Scan Shutter Cameras

Page 45

Page 37 Troubleshooting 5.2 Information and Support Resources For further information and support: Phone:

(408) 747-0300 (800) 445-5444 (800) 3-PULNIX (24-hour message access)

Fax:

(408) 747-0660

E-mail:

imaging@pulnix.com

Mail:

PULNiX America Inc. Sales Department 1330 Orleans Drive Sunnyvale, CA 94089 ATTN: Video Applications

Web Site:

www.pulnix.com

TM-1020 Series Progressive Scan Shutter Cameras