Page 46
Page 38 Appendix
6
Appendix 6.1 Specifications TABLE 8.
TM-1020 Series Camera Specifications Table
Feature
TM-1020-15 TM-1020-15CL TM-1020A-15
TM-1020-30 TM-1020-30CL
Imager
1” (9.1mm x 9.2mm) progressive scan interline transfer CCD
Pixels
1024 (H) x 1024 (V), 1008 x 1018 active
Cell size
9.0µm x 9.0µm
Scanning
1050 lines at 15Hz; 1024 x 512 lines at 30Hz (two-row binning)
1050 lines at 30Hz Partial scan: 500L at 58Hz : 250L at 102Hz
Sync
Internal/external auto switch HD/VD, 4.0 Vp-p impedance 4.7KΩ VD=15Hz±5%, non-interlace HD=15.734kHz±5%
Internal/external auto switch HD/VD, 4.0 Vp-p impedance 4.7KΩ VD=30Hz±5%, non-interlace HD=31.47kHz±5%
Data clock output
20.000 MHz
40.000 MHz
Resolution
Digital: 1008 (H) x 1018 (V), (Analog: over 700 TV lines (H) x 800 TV lines (V))
S/N ratio
50dB min. (AGC: off)
Min. illumination Video output
1.0 lux with factory defaults: f=1.4 without IR cut filter (no shutter) Sensitivity: 12µV/ eAnalog: 1.0 Vp-p composite video, 75Ω Digital output: 8-bit RS-644 (TM1020-15: 12S-RS-422) Camera Link (CL models only)
Analog: 1.0 Vp-p composite video, 75Ω Digital output: 8-bit RS-644 Camera Link (CL model only)
AGC
Not available
Gamma
Programmable LUT (1.0 std.)
Lens mount
C-mount (use 1” format lenses)
Power requirement
12V DC, 500mA (current measured at 25°)
Operating temp.
-10°C to 45°C*
Random vibration
7 Grms (10Hz to 2000Hz)
Shock
70G
Size (W x H x L)
44mm x 44mm 64mm (1.73” x 1.73” x 2.50”)
Weight
Std. version:133 grams, 4.7 oz (without tripod) CL version: 137 grams, 4.8 oz (without tripod) tripod weight: 13.8 grams 0.5 oz
Power cable
12P-02S (optional)
Power supply
PD-12UUP (includes power connector)
TM-1020 Series Progressive Scan Shutter Cameras
Page 47
Page 39 Appendix
Feature Functional options I/O
TM-1020-15 TM-1020-15CL TM-1020A-15
TM-1020-30 TM-1020-30CL
Adjustable back-focus front end, pixel clock locking† 26CL-02-26 digital output cable (CL models)
*. Refer to Section 2.2.2 on page 6 for information on camera heat dissipation. Image quality will degrade with increasing temperature. †. This option not available at time of publishing. Please check with PULNiX for current availability.
TM-1020 Series Progressive Scan Shutter Cameras
Page 48
Page 40 Appendix 6.1.1 TM-1020 Series Physical Dimensions FIGURE 17. Physical Dimensions
TM-1020 series camera
Rear Panel for Camera Link camera
Rear Panel for standard camera UP SHUTTER MODE DOWN
44.0 [1.73]
CAMERA LINK
44.0 [1.73]
DIGITAL
1 2 3
POWER
9 8
10 11
4
7
12 5
6
POWER
VIDEO
VIDEO
7.0 [0.28] 34.0 [1.34]
15.3 [0.60] 25.4 [1.00]
44.0 [1.73]
44.0 [1.73]
63.6 [2.50] 76.3 [3.00]
22.0 [0.87] 1/4-20 11.0 [0.43] 2X M6
23.0 [0.91] 19.0 [0.75] 2X M3 X 6.0 [0.24] SOC HD CAP SCR
18.0 [0.71]
6.1.2 Spectral Response FIGURE 18. Spectral Response 0.4
0.35
Absolute Quantum Efficiency
0.3
0.25
0.2
0.15
0.1
0.05
0 400
450
500
550
600
650
700 750 Wavelength (nm)
800
TM-1020 Series Progressive Scan Shutter Cameras
850
900
950
1000
Page 49
Page 50
Page 51
Page 52
Imaging Products PULNiX America, Inc. 1330 Orleans Drive Sunnyvale, CA 94089
Tel: 408-747-0300 Tel: 800-445-5444 Fax: 408-747-0660
Email: imaging@pulnix.com www.pulnix.com
69-0076 Rev. B
Page 53
AccuPiXEL Series Camera-Control Software Installation and Operation Manual
69-0109 Rev. A
Imaging Products