Schneider Electric's two-page product data sheet for the 24503, a Multi 9 C60 UL1077 single-pole miniature circuit breaker rated 4 A with a D trip curve. It lists the breaker's ratings, breaking capacities, dimensions, wiring terminals and operating environment.

Device
Multi 9 C60 UL1077 miniature circuit breaker, 1 pole, for distribution p. 1
Rated current
4 A at 25 °C p. 1
Trip curve
D curve, thermal-magnetic trip unit p. 1
Network
AC and DC, 50/60 Hz p. 1
Rated voltage (Ue)
240 V AC, 415 V AC, 60 V DC p. 1
UL 1077 breaking capacity
AIR 5 kA at 277 V AC, 10 kA at 240 V AC, 10 kA at 65 V DC p. 1
IEC breaking capacity
Icu 10 kA at 240 V AC, 3 kA at 415 V AC, 10 kA at 60 V DC (EN/IEC 60947-2) p. 1
Magnetic trip
12 x In +/- 20 % AC; 17 x In +/- 20 % DC p. 1
Terminals
Tunnel terminals, top or bottom, rigid wire 2.5 to 25 mm² (AWG 14 to AWG 4), 14 mm strip, 2.5 N.m p. 2
Mounting
Clips onto DIN rail; 18 mm wide (two 9 mm pitches) p. 1
Dimensions
81 mm high, 18 mm wide, 73 mm deep; 0.11 kg p. 1, 2
Operating temperature
-30 to 70 °C (storage -40 to 80 °C) p. 2
Durability
20000 mechanical cycles, 10000 electrical cycles p. 2
Insulation
Ui 500 V AC; Uimp 6 kV p. 1

What this sheet walks you through

  • Checking breaking capacity by voltage and standard p. 1
  • Wiring the terminals: wire size, strip length and torque p. 2
  • Operating environment: humidity, altitude and temperature p. 2

Good to know

  • The sheet states it is not meant for judging whether the product suits a specific application. p. 1
  • Protection is IP20, or IP40 in a modular enclosure (IEC 60529). p. 2

Questions this sheet answers

What is the current rating of Schneider 24503?

The 24503 is a 1-pole C60 UL1077 breaker rated 4 A at 25 °C, with a D trip curve. p. 1

Can the 24503 be used on DC?

Yes. The sheet lists DC and AC network types, with a rated voltage of 60 V DC and UL 1077 AIR of 10 kA at 65 V DC. p. 1

What wire size fits the 24503 terminals?

Its tunnel terminals take rigid wire of 2.5 to 25 mm² (AWG 14 to AWG 4), top or bottom, tightened to 2.5 N.m. p. 2

How wide is the C60 24503 breaker?

It is 18 mm wide (two 9 mm pitches), 81 mm high and 73 mm deep. p. 1, 2

The file

Size and text

Pages2
PDF76 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Schneider 24503 Spec Sheet

The text of page 1, from the PDF itself

Product data sheet Characteristics

24503

Multi 9 - C60 UL1077 - MCB - 1P - 4 A - D Curve - 277 V - 5 kA

Range of productC60RangeMulti 9Product nameMulti 9 C60

Product or componenttype

Miniature circuit-breaker

Device short nameC60 UL1077Device applicationDistributionPoles description1P

Number of protectedpoles

1[In] rated current4 A at 25 °CNetwork typeDC ACTrip unit technologyThermal-magneticCurve codeDBreaking capacity codeNBreaking capacity

AIR 10 kA at 65 V DC conforming to UL 1077 AIR 10 kA at 65 V DC conformingto CSA C22.2 No 235 Icu 3 kA at 415 V AC conforming to EN/IEC 60947-2 Icu 10 kA at 240 V AC conformingto EN/IEC 60947-2 Icu 3 kA at 415 V AC conforming to GB 14048.2 Icu 10 kA at 240 V AC conforming to GB 14048.2 AIR 5 kA at 277 V AC conforming to UL 1077 AIR 10 kA at 240 V AC conforming to UL 1077 AIR 5 kA at 277 V AC conformingto CSA C22.2 No 235 AIR 10 kA at 240 V AC conformingto CSA C22.2 No 235 Icu 10 kA at 60 V DC conforming to EN/IEC 60947-2 Icu 10 kA at 60 V DC conforming to GB 14048.2

Suitability for isolation

Yes conforming to EN/IEC 60947-2

Complementary Network frequency

50/60 Hz

[Ue] rated operational voltage

240 V AC 60 V DC 415 V AC

Magnetic tripping limit

12 x In +/- 20 % AC 17 x In +/- 20 % DC

Limitation class

3 conforming to EN/IEC 60947-2

[Ui] rated insulation voltage

500 V AC conforming to EN/IEC 60947-2

[Uimp] rated impulse withstand voltage

6 kV conforming to EN/IEC 60947-2

Contact position indicator

YesControl typeToggleLocal signallingON/OFF indicationMounting modeClip-onMounting supportDIN railConnection pitch18 mm Between devices9 mm pitches2Height81 mmWidth18 mmSep 7, 20181

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Main

Page 2 of Schneider 24503 Spec Sheet

The text of page 2, from the PDF itself

Depth73 mmProduct weight0.11 kgColourGreyMechanical durability20000 cyclesElectrical durability10000 cycles

Provision for padlocking

Padlockable

Connections - terminals

Tunnel type terminal, top or bottom rigid wire(s) 2.5...25 mm² max (AWG 14...AWG 4)

Wire stripping length14 mm top or bottomTightening torque2.5 N.m top or bottomCompatibility codeC60_UL1077Environment Standards

UL 1077 GB 14048.2 EN/IEC 60947-2 CSA C22.2 No 235

Product certifications

CSA CCC IEC UR

IP degree of protection

IP40 for modular enclosure conforming to IEC 60529 IP20 conforming to IEC 60529

Pollution degree

3 conforming to EN/IEC 60947-2

Overvoltage categoryIVTropicalisation

2 conforming to IEC 60068-1

Relative humidity95 % 55 °COperating altitude2000 m

Ambient air temperature for operation

-30...70 °C

Ambient air temperature for storage

-40...80 °C

Offer Sustainability Sustainable offer status

Green Premium product

Product environmental profile

Available

Product end of life instructions

Need no specific recycling operations

Contractual warranty Warranty period

Product Life Status
2

18 months

End of commercialisation