Page 1 of Multi 9: Modular protection for OEMs, Catalogue 2018

Spec sheet · Schneider

Multi 9: Modular protection for OEMs, Catalogue 2018

Spec sheet84 pagesPDF 11 MB

Schneider Electric Multi 9 catalog of DIN rail miniature circuit breakers, residual current devices and accessories for OEMs.

Download the PDF11 MB

Filed with · 6 models

Also filed with these models on the old site

Summary

What is in it

Schneider Electric's 2018 catalog for the Multi 9 range of DIN rail modular protection devices for equipment manufacturers. It lists miniature circuit breakers (C60BP, C60BPR, C60SP, C60H-DC, C60N, C60H, C60L, C60CTRL, N40N) with ratings, breaking capacities, catalog numbers, dimensions and technical data, then residual current devices, auxiliaries, comb busbars and distribution blocks, and technical information on standards, tripping curves and temperature effects.

Its parts

  1. Miniature circuit breakers
  2. Residual Current Devices
  3. Auxiliaries and accessories
  4. Technical information
  5. Control panel technical guides library

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

Schneider Electric's 2018 catalogue for the Multi 9 range of DIN rail modular protection devices for equipment makers. It covers the C60BP, C60BPR, C60SP, C60H-DC, C60N, C60H, C60L, C60CTRL and N40N miniature circuit breakers, residual current devices, and common auxiliaries and accessories, with ratings, technical data and catalogue numbers. The catalogue numbers the site files it under (17414, 17423, 24430, 24435, 24503, 24505) do not appear in the pages read.

Read for this summary: pages 1 to 3, 5, 7, 9 to 11, 20 to 23 and 43 to 46 of 84.

Range
Multi 9: DIN rail modular devices for equipment makers (OEMs), giving protection, signaling functions and accessories p. 3
Circuit breakers
C60BP, C60BPR, C60SP, C60H-DC, C60N, C60H, C60L, C60CTRL and N40N miniature circuit breakers p. 9
C60BP
C60BP: UL 489 branch circuit breaker, Z, C and D curves, tunnel terminals, 0.5 to 63 A p. 10
C60BP UL 489 ratings
C60BP: up to 35 A at 480Y/277V and up to 63 A at 240 V p. 7
C60BP standards
The catalogue states UL 489 (document #E215117), CSA C22.2 No 5, IEC/EN 60947-2 and GB 14048-2 conformity for the C60BP p. 11
C60BP electrical data
C60BP: insulation voltage 500 V, impulse withstand 6 kV, reference temperature 25°C / 77°F p. 11
C60BP temperatures
C60BP: operating -30°C to +70°C / -22°F to 158°F; storage -40°C to +80°C / -40°F to 176°F p. 11
C60N
C60N: IEC/EN 60947-2 breaker, B, C and D curves, 1P to 4P, 1 to 63 A p. 20
C60H
C60H: IEC/EN 60947-2 breaker, B, C and D curves, 1P to 4P, 1 to 63 A p. 22
C60H-DC
C60H-DC: UL1077 breaker for direct current circuits up to 500 V DC p. 7, 9
Mounting
Clips on a 35 mm DIN rail, any mounting position p. 11, 21
Auxiliaries
Remote tripping and open/closed/tripped indication auxiliaries clip on the left side without tools p. 43
MN undervoltage release
MN: trips the breaker when its input voltage falls to between 70 % and 35 % of Un p. 44
Residual current devices
GFP ground fault protector, RCCB ID, Vigi C60 and Vigi N40 add-ons, N40 Vigi p. 9

What this sheet walks you through

  • Choosing a Multi 9 breaker by standard, trip curve and terminal type p. 9
  • C60BP breaking capacities and catalogue numbers p. 10
  • Connecting copper cables to the C60BP p. 11
  • C60N and C60H breaking capacities and catalogue numbers p. 20, 22
  • C60N and C60H connection and technical data p. 21, 23
  • Combining indication and tripping auxiliaries on one device p. 43
  • Undervoltage releases for emergency stop and preventing accidental startups p. 44
  • Shunt releases for tripping from a pushbutton or dry contact p. 45
  • Open/closed and fault indicating contacts (OF, OF.S, OFsp, SD, SD+OF) p. 46

Good to know

  • Tripping auxiliaries go on first; with two tripping devices, the MN undervoltage release first; among indication auxiliaries, the SD first. p. 43
  • Before any servicing, switch off the mains supply, since voltage is present at terminals E1/E2. p. 45
  • The C60H-DC is for DC circuits only. p. 9
  • The C60CTRL is meant for protecting control circuits. p. 9

Questions this sheet answers

What is the UL 489 rating of the C60BP?

Up to 35 A at 480Y/277V and up to 63 A at 240 V. p. 7

What temperatures can a C60BP work in?

It operates from -30°C to +70°C (-22°F to 158°F) and can be stored from -40°C to +80°C. p. 11

What current ratings does the C60N come in?

1 to 63 A, with B, C or D trip curves and 1 to 4 poles. p. 20

What does the MN undervoltage release do?

It trips the breaker when its input voltage falls to between 70 % and 35 % of Un, and keeps it from closing until the voltage returns. p. 44

How do Multi 9 auxiliaries attach to a breaker?

They clip onto the left-hand side of the breaker with no tool. p. 43

The whole text · 9 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 8481-84

The file

Revision and size

RevisionCatalogue 2018
PublisherSchneider Electric
Pages84
PDF11 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 4 of 84

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 84
Page 2
Page 2of 84
Page 3
Page 3of 84
Page 4
Page 4of 84