Programmable controller Twido Catalog: Connections (continued), pages 37 to 44

Pages 37 to 44 of 76, from Programmable controller Twido Catalog

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Schneider ABE 7E16EPN20, Schneider ABE 7E16SPN20, Schneider TWDALM3LT, Telemecanique ABE 7E16SPN22 and Telemecanique ABE 7E16SRM20

Page 37

Connections (continued)

Twido programmable controller

0

Analog I/O modules

Analog output modules TWD AMO 1HT

TWD AVO 2HT

–

+

+

24 V

–

–

+

+

24 V

24 V

24 V

0V 0V

+

+

Voltage/current preactuator –

OUT

–

+

Analog voltage input peripheral

OUT 1

0V 0V 0V 0V

+

Analog voltage input peripheral

OUT 2

0V 0V b Fit a fuse of appropriate size for the sensor type. b Do not connect any wires to the unused channel.

Mixed input/output module TWD AMM 3HT

–

TWD ALM 3LT

+

–

+

24 V

+ Voltage/current pre– actuator

– +

24 V

+

+

24 V

– +

OUT

–

Voltage/current pre– actuator

NC

+ Voltage/current sensor

–

+

IN 0

–

Voltage/current sensor

–

+ –

NC A

B'

+ B'

B

IN 1

+ –

OUT

–

A

Thermocouple K, J, T

NC

+

Pt 100 temperature probe

+

24 V

IN 0

– B NC A

+ B'

IN 1

– B b Fit a fuse of appropriate size for the sensor and pre-actuator types. b For a Pt 100 3-wire temperature probe (RTD), connect the three wires to terminals A, B' and B (channels IN0 and IN1). b For a Pt 100 2-wire temperature probe (RTD), connect the two wires to terminals A and B' and make a bridge between B' and B (channels IN0 and IN1). b For a thermocouple, connect the two wires to the + and - terminals (channels IN0 and/or IN1). b Do not connect any wires to unused channels.

37

Page 38

Twido programmable controller

Presentation, description, diagnostic

Master module for AS-Interface cabling system 0

Presentation

Indicator bank

Master module TWD NOI 10M3, for AS-Interface cabling system allows the Twido controller (version u 2.0) to perform the function of AS-Interface master.

Twido controller + master module TWD NOI 10M3 Power supply

Sensors

The cabling system consists of a master station (Twido controller) and slave stations. The master, which supports the AS-Interface profile, polls each of the devices connected to the AS-Interface cabling system, in turn, and stores information gathered (sensor/actuator status, operating status of the devices) in the controller memory. Communication on the AS-Interface cabling system is managed in a way that is totally transparent to the Twido application program.

AS-Interface cabling system

Control station

Safety interface Safety monitor

XBL Keypad

Motor starter

The TWD NOI 10M3 master module manages the following with the AS-Interface M3 profile: b discrete slave modules (maximum of 62 slaves arranged in 2 banks, A and B, of 31 addresses each) b analog slaves (maximum of 7 slaves in bank A) The AS-Interface M3 profile supports analog profile 7.3 (7 slaves), but does not support analog profile S-7.4. The maximum number of TWD NOI 10M3 modules per Twido controller is 2. 7 discrete, analog and AS-Interface I/O modules are controlled by TwidoSoft software, see page 64. An AS-Interface power supply is essential to supply the various modules on the cabling system. It should preferably be located close to the stations with high power consumption. For more information on power supplies, see pages 10 and 16.

Description 5

6 1 4

2

3

7

Module TWD NOI 10M3 takes the form of a standard-size module. It is connected to a Twido base controller (compact or modular) in the same way as any I/O module. It has the following on the front panel: 1 A display block comprising: b 6 pilot lights indicating the module operating modes: v green PWR pilot light: module powered up v red FLT pilot light: error in the configuration loaded v green LMO pilot light: module in local mode v green CMO pilot light: module in connected mode v red CNF pilot light: not used v red OFF pilot light: module in protected, unconnected mode b 6 green pilot lights, 3 for inputs, 3 for outputs: 2 A block for displaying the status of the addresses 3 Two push buttons PB1 and PB2 for controlling the status of the slaves by selecting their address and changing the mode 4 An extension connector for electrical connection to the previous module 5 A connector (on the RH side) for I/O expansion modules TWD Dpp and TWD App (4 or 7 depending on version) 6 A latching mechanism for attachment to the previous module 7 A power supply removable screw terminal block

Diagnostics The 30 pilot lights on the front panel of the module are used in conjunction with the two push buttons for diagnostics by the Twido controller. The display block on the front panel of master module TWD NOI 10M3 allows simplified local diagnostics to be performed by displaying the slaves present on the AS-Interface cabling system. Software set-up The AS-Interface cabling system is configured by the TwidoSoft software, see pages 64 to 71. The services offered are based on the principle of simplicity: b Management of profile tables, parameters and data by the master is done, in a way that is transparent to the user. b Topological addressing of I/O: any AS-Interface slave defined on the cabling system has a topological address assigned to it, in a way that is transparent to the user. Each AS-Interface module sensor/actuator is seen by the Twido programmable controller in the same way as any “In-rack” I/O.

38

0

Page 39

Twido programmable controller

Characteristics, references, dimensions, connection

0

Master module for AS-Interface cabling system 0

General characteristics Module type AS-Interface profile Type of addressing Product certifications Degree of protection Altitude Temperature Relative humidity Degree of pollution Immunity to corrosion Vibration Mounted on 5 rail resistance Plate or panel mounted (using mounting kit TWD XMT5) Shock resistance As-Interface external power supply Internal current At c 5 V At c 24 V AS-Interface consumption at c 24 V m/s2 cV mA mA mW

TWD NOI 10M3 AS-Interface M3, V 2.11 (profile S-7.4 not supported) Standard and extended AS-Interface n° 47801 IP 20 Operation: 0…2000. Transport: 0…3000 Operation: 0…+ 55. Storage: - 25…+ 70 30 to 95 % (without condensation) 2 conforming to IEC 60664 Free of corrosive gases 10…57, amplitude 0.075 mm, 57…150 (acceleration: 9.8 m/s2); for 2 hours on all 3 axes 2…25, amplitude 1.6 mm, 25…100 (acceleration: 39.2 m/s2); for 90 minutes on all 3 axes 147 (15 gn) duration 11 ms, on all 3 axes 29.5…31.6 80 0 540 ms ms ms

3 0.156 x (1 + N) where N = number of active slaves 5 ms

10 7 62 248 = 124 inputs + 124 outputs 434 = 248 inputs + 186 outputs 100 300 30 m °C

Hz Hz

Communication characteristics As-Interface cabling system cycle time

With 1 to 19 slaves With 20 to 62 slaves With 31 standard slaves or slaves in banks A and B With 62 slaves in banks A and B Max. no. Analog modules (1) of modules Discrete modules (1) Max. no. of I/O Standard slaves Slaves in banks A and B Max. length of Without splitter block or extension AS-Interface cable With a total of 2 splitter blocks or extensions AS-Interface cabling system voltage m m cV

References Description AS-Interface master module for Twido programmable controllers V u 2.0 Description Mounting kit Description

TWD NOI 10M3

Flat cable for AS-Interface cabling system (yellow)

Number per controller 2

Protocol/profile Number of I/O (1) AS-Interface/M3 62 discrete modules max., 7 analog modules max.

Reference TWDNOI10M3

Description

Reference

For plate or panel mounting of the module Sold in lots of 5 Power supply Length m For AS-Interface cabling system 20 50 100

TWDXMT5 Reference XZCB10201 XZCB10501 XZCB11001

Weight kg 0.085

Weight kg – Weight kg 1.400 3.500 7.000

(1) When analog and discrete modules are connected simultaneously to the network, the analog modules use addresses 1 to 31 in bank A. When an analog module uses a certain address, the module addresses having the same number in bank B cannot be occupied for slaves in banks A/B.

Dimensions

Connection

TWD NOI 10M3

TWD NOI 10M3 Brown wire

0.15 0.92 (23.5) (3.8)

As-Interface flat cable Blue wire

3.54 (90)

2.75 (70)

0.17 (4.5)

0.37 (9.4)

Dual Dimensions inches (mm)

39

Page 40

Twido programmable controller

Presentation, description

0

0

Communication

Presentation In order to communicate with an intelligent environment, Twido compact and modular programmable controllers offer an RS 485 serial communication port on the modules, an optional type RS 485 or RS 232 link and, for compact base controller TWD LCAE 40DRF, an integrated RJ45 Ethernet port (Modbus TCP).

Modbus network

CANopen bus

These three ports allow Twido compact and modular controllers to use six communication protocols: Programming, Modbus, CANopen, Ethernet, ASCII and “Remote link”. Twido compact (TWD LCpA 24DRF or TWD LCAp 40DRF) or modular base controllers can also accommodate the CANopen bus master module TWD NCO1M. TwidoPort interface module 499 TWD 01100, used in conjunction with a compact or modular Twido programmable controller version ≥ 3.0 allows communication on the Ethernet network under Modbus TCP. This solution, which is easy to connect and configure, is transparent to the application.

Ethernet network

Description Compact base controllers have the following on the front panel: 1 An RS 485 serial port, with mini-DIN type connector, for connection to the programming terminal 2 A slot for fitting a 2nd optional port (RS 485/RS 232) using TWD NAC ppp adapters

1

TWD NAC 485D/232D

3

Compact base controller

4

1

Modular base controllers have the following on the front panel: 1 An RS 485 serial port, with mini-DIN type connector, for connection to the programming terminal The slot for fitting a 2nd optional port (RS 485/RS 232) using adapters TWD NAC ppp is located behind the removable cover 2 of a TWD NOZ pppp interface module 3 or a TWD XCP ODM display module 4 The interface and display modules connect to the left-hand side of modular base controllers.

or

+

Twido controller communication ports

2 or TWD NAC 485T

Serial port

2 RS 485 mini-DIN TWD NOZ pppp TWD XCP ODM or TWD NAC 485D/232D

TWD NAC 485T

Modular base controller

Integrated Ethernet port RJ45

Optional port (2nd port) RS 485 mini-DIN

Compact base controllers Compact base TWD NAC 485D All compact controller (1) base controllers TWD LCAE 40DRF TWD LCpA pppp TWD LCAp 40DRF Modular base controllers All modular – TWD NOZ 485D base controllers (1) TWD LMDA pppp or TWD XCP ODM + TWD NAC 485D

RS 232 mini-DIN

RS 485 screw terminal block

TWD NAC 232D TWD NAC 485T (2) (1)

TWD NOZ 232D (2) or TWD XCP ODM + TWD NAC 232D

TWD NOZ 485T (1) or TWD XCP ODM + TWD NAC 485T

(1) With max. cable length: 200 m. (2) With max. cable length: 10 m. Note: if the RS 232 physical layer is used, and for a length greater than 10 metres, use the RS 485 physical layer and an RS 232C/RS 485 line adapter reference XGS Z24.

40

Page 41

Presentation, description, configuration, characteristics

Twido programmable controller

0

Communication CANopen bus master module 0

532659

Presentation Master module TWD NCO1M for the CANopen bus allows Twido programmable controllers version ≥ 3.0 - compact controller models TWD LCpA 24DRF or TWD LCAp 40DRF and all modular controllers - to act as CANopen master. The bus consists of a master station, the Twido controller and slave stations. The master is in charge of configuration, exchanges and diagnostics on the slaves. The CANopen bus is a communication type bus and allows management of various slaves such as: b Discrete slaves b Analog slaves b Variable speed controllers b Motor starters The Twido CANopen master controls up to 16 slaves, each with an input PDO (Process Data Object) and an output PDO. If a slave has more than one PDO, the maximum number of slaves managed is reduced by that number. The Twido CANopen master can control a maximum of 16 input PDO and 16 output PDO.

5 2 1

Description CANopen bus master module TWDNCO1M comprises: 1 An grounded, 3-way, c 24 V supply connector 2 A PWR LED, indicating module power ON or OFF 3 A 9-way SUB-D connector for connection to the CANopen bus 4 An ground screw 5 A connector for connection to the Twido controller or to another I/O expansion module

3 4 TWD NCO1M

Configuration The Twido controller's CANopen bus is configured using TwidoSoft software version ≥ 3.0. The various services offered are: b Selection of the slave type from a list that can be modified by simply importing a description file of the EDS (Electronic Data Sheet) type b The position of the slave on the bus: definition of the slave number b Selection of variables from the list of variables managed by the slave b Linking of variables to the exchange data b Symbolization of exchange data For certain slaves, such as ATV 31 variable speed controllers, one or more profiles are supplied allowing the slave to be configured according to a mode predefined by Schneider Electric. The use of profiles provides the user with an operating mode that is described, without having to configure it.

Characteristics Module type Operating temperature Storage temperature Relative humidity Level of pollution Housing conforming to IEC 60664-1 PCB Degree of protection Immunity to corrosion Altitude Operation Transport Vibration resistance Rail mounting

°C °C m m

Plate or panel mounting (using mounting kit TWD XMT5) Shock resistance

Conforming to IEC 61131

Permissible voltage variation Protection against polarity inversion on the bus inputs CANopen bus interface connector Current consumption At c 5 V At c 24 V Power dissipated cV mA mA W

TWD NCO1M 0…55 - 25…+70 30…95 % (without condensation) 3 2 IP 20 Against corrosive gases 0…2000 0…3000 10…57 Hz with an amplitude of 0.075 mm, 57…150 Hz with an acceleration of 9.8 m/s2 (1 gn), Duration: 2 hours per axis on each of the three axes perpendicular to each other. 2…25 Hz with an amplitude of 1.6 mm, 25…100 Hz with an acceleration of 39.2 m/s2 (4 gn), Duration: 90 min per axis on each of the three axes perpendicular to each other. 147 m/s2 (15 gn), duration 11 ms, 3 impact shocks per axis, on the three axes perpendicular to each other. 19.2…30 Yes 9-way SUB-D 50 (internal bus) 50.5 (internal supply) 1.2 (at c 24 V)

41

Page 42

Presentation, description, characteristics

Twido programmable controller Communication TwidoPort interface module 0

532718

Presentation

2

TwidoPort module 499 TWD 01100 is an Ethernet interface that is easy to use and dedicated to a compact or modular Twido programmable controller version ≥ 3.0. It allows incorporation of the Twido controller into an Ethernet network as a passive device (slave). With version 3.0 of TwidoSoft software and of the Twido operating system, the TwidoPort module is ready for use. When connected to the RS 485 port of the Twido programmable controller, the TwidoPort module acts as a gateway between the Ethernet network and the Modbus network. The connecting cable is supplied with the module. The main characteristics of the TwidoPort module are as follows: b Connects to the RS 485 port of the Twido controller; no external auxiliary supply is necessary b Automatic detection of the serial link configuration b Ethernet interface: v 10/100 Mbit/s v Auto MDIX function v RJ45 type connector b Ethernet configuration: v takes the Ethernet configuration from the Twido application configuration (normal mode) v BootP function v supports manual configuration using Telnet b Provides Ethernet statistics via a Telnet session

1

Description 4 3 499 TWD 01100

TwidoPort 499 TWD 01100 interface module comprises: 1 Five LEDs (SER ACT, STATUS, LINK, 100 MB, ETH ACT) indicating performances associated with the TwidoPort module 2 An RJ45 connector for connection of the power supply and communications to the RS 485 on the Twido controller, cable TWD XCA RJP03P supplied (1) 3 An RJ45 connector (accessed through the bottom of the module) for connection to the Ethernet TCP/IP network 4 An grounding screw (accessed through the bottom of the module)

Characteristics Module type Operating temperature Storage temperature Relative humidity Level of pollution Degree of protection Immunity to corrosion Altitude

499 TWD 01100 0…55 - 40…+70 10…95 % (without condensation) Conforming to IEC 60664-1 2 IP 20 Against corrosive gases Operation m 0…2000 m 0…3040 Storage 10…57 Hz with an amplitude of 0.075 mm (peak to peak), Vibration resistance Rail mounting 57…100 Hz with constant acceleration of 9.8 m/s2 (1 gn), Duration: 10 cycles at 1 octave/min for each of the 3 perpendicular axes. 147 m/s2 (15 gn), duration 11 ms, 3 impact shocks for each of the 3 perpendicular Shock resistance Conforming to IEC 61131-2 axes. mA 180 Max. consumption At c 5 V cV 5 ± 0.5 Supply voltage (1) Cable TWD XCA RJP03P, connected to port 1 on the Twido controller, forces configuration of the port according to the parameters of the Programming protocol. Using cable TWD XCA RJP03, sold separately, allows port 1 of the Twido controller to be used with the parameters described in the application configuration.

42

°C °C

0

Page 43

Twido programmable controller

Presentation, characteristics

0

0

Communication Communication protocols

Programming protocol Link by modem 1 Remote programming PC 2 Cable TSX PCX 1031 on serial port (Rx/Tx crossing to be made or use cable TSX PCX 1130) 3 Modem for transmitting/receiving data 4 Telephone or radio link 5 Twido compact or modular controller

3 4

1

3 2 6 7

5

Link by cable 1 Programming PC 6 Cable TSX PCX 1031 on RS 485 serial port or cable TSX PCX 3030 on USB port for Windows 2000 or XP 7 Twido compact or modular controller Wireless link 1 Programming PC with integrated Bluetooth technology or Bluetooth gateway for PC, reference VW3 A8115 2 Pocket PC with TwidoAdjust software For optimum performance, use a Pocket PC with integrated Bluetooth technology. 3 Bluetooth gateway VW3 A8114 4 Twido compact or modular controller

1

OR

3

4

2

Characteristics Protocol type Flow rate Physical layer Connection Compatibility

Kbit/s

Programming 19.2 RS 485 Serial port Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and modular base controllers TWD LMDA pppp

Modbus protocol

2

1

3

Modbus network

3

Modbus network

5

6

4 9 8 7

8

7 6

Twido controller connected directly on the Modbus network 1 Magelis compact display XBT N40p 2 Cable XBT Z978 on serial port 3 Cable for optional RS 485 port, reference TWD XCA RJ0pp 4 Twido modular controller 5 Modbus hub LU9 GC3 6 Modbus tap link cable VW3 A8 306 Rpp 7 Line end adapters VW3 A8 306 RC 8 Modbus T-junctions VW3 A8 306 TFpp (with cables) 9 Twido compact controller 10 Devices: Altistart 48 starters, Altivar 28, Altivar 31 variable speed drives, Modbus OTB I/O interface module, Zelio Logic SR3 smart relay and TeSys motor starters

6

10

Characteristics Protocol type Flow rate Data bits Stop bits Parity Physical layer Connection Compatibility

Kbit/s

Modbus 1.2…38.4 Initial value: 19.2 7 or 8 Initial value: 8 1 or 2 Without, even or odd Initial value: without RS 485/RS 232 (point-to-point) Serial port (RS 485) or optional port (RS 485/RS 232) Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and modular base controllers TWD LMDA pppp

43

Page 44

Twido programmable controller

Presentation (continued), characteristics (continued)

0

Communication Communication protocols

CANopen protocol Direct connection of the Twido CANopen master module 1 Magelis compact display XBT N40p and cable XBT Z978 on serial port 2 Twido compact controllers TWD LCpA 24DRF or TWD LCAp 40DRF or Twido modular controllers, version ≥ 3.0 3 Twido TWD NCO1M CANopen bus master module 4 CANopen FTB I/O splitter box r 5 ATV 31 starter 6 CANopen OTB I/O interface module r

1 2

3

CANopen bus

4

5

6 r Available 2nd quarter 2005.

Characteristics Protocol type Transmission

Flow rate Medium Type Method Maximum number of devices Maximum length of bus

Structure Configuration

Kbit/s m

Compatibility

CANopen 125…500 Double shielded twisted pair EN 50325 - ISO 11898 CSMA-MA 16 1000 Compact base controllers TWD LCpA 24DRF and TWD LCAp 40DRF and modular base controllers TWD LMDA pppp, version ≥ 3.0

Ethernet protocol

1 2

Modbus Network

3

4 r Available 2nd quarter 2005.

5 6

Twido controller connected directly on the Ethernet network 1 Magelis compact display XBT N40p and cable XBT Z978 on serial port 2 Twido master or slave, 40 I/O compact base controller TWD LCAE 40DRF 3 Premium automation platform (1) 4 Twido slave, compact or modular base controller 5 TwidoPort 499 TWD 01100 interface module 6 ConneXium 499 NEH 104 10 hub or ConneXium 499 NES 251 00 switch 7 Ethernet OTB I/O interface module r 8 Web Factory Cast Gateway TSX ETG 1000 (2)

Ethernet Network

Ethernet Network Ethernet Network

7

Ethernet Network

8

Modbus SL network

Characteristics Protocol type Transmission Services Transparent Ready

Structure Configuration Compatibility

44

Flow rate Medium Class

Web Server (function provided by gateway TSX ETG 1000) Ethernet TCP/IP communication management services (services supported by controllers in the Twido range) Type Method Maximum number of devices Max. length of network Master Slaves

Mbit/s

Ethernet 10…100 Double twisted pair A 15 (for Twido controller TWD LCAE 40DRF and TwidoPort interface module 499 TWD 01100), C 20 (for gateway TSX ETG 1000) Access to the product description and status and to the “Rack Viewer” island diagnostics Access to configuration functions and to “Data editor” variables Loading of user Web pages via the “Web page loader” software tool Modbus messaging (read/write of data words) I/O Scanning (Twido controllers version ≥ 3.0)

10BASE-T/100BASE-T CSMA-CD 256 max per segment m 500 Compact base controller TWD LCAE 40DRF Compact base controllers TWD LCpA pppp and TWD LCAp 40DRF and modular base controllers TWD LMDA pppp, version ≥ 3.0 (1) Please see our “Premium automation platform” catalog, # MKTED204032EN. (2) Please see our “Ethernet TCP/IP and the Web” catalog # MKTED204073EN.

0