Page 7
TSX Nano PLC, Programming
Simple Applications
Software Characteristics
Special Functions
The example below is for a KM1 starter. After a stop, no restart is permitted for an adjustable time period (KA1). A display, H, is lit continuously while the machine is operating, and blinks during the time period in which a restart is not permitted.
PLC Characteristics • Program memory, 1000 instructions maximum
• Scan: normal or periodic
• Protected data memory, 256 internal words, 64 constant words, 128 internal bits
• Execution time: 0.2 µs for an elementary instruction
Combinational List Instructions
List of Grafcet Instructions
LD, LDN, LDR, LDF: read the state of a bit (direct, inverse, rising and falling edges) ST, STN, R, S: update and output (direct, inverse, set, reset) AND, ANDN, ANDR, ANDF: logic AND with a bit (direct, inverse, rising and falling edges) OR, ORN, ORR, ORF: logic OR with a bit (direct, inverse, rising and falling edges) AND (,) OR(,): open and close parentheses (nested up to eight levels) XOR, XORN, XORR, XORF: exclusive OR with a bit MPS, MRD, MPP: memory stack management MCR, MCS: master relay
- * - i : step (1 ≤ i ≤ 62) = * = i : initial step (1 ≤ i ≤ 62) #i : activates the step i # : deactivates the current step #Di : deactivates a step i from another step = * =POST: start of post-processing Xi : bit associated with the step
Standard Function Blocks
Dedicated Function Blocks
32 Timers: TMi, 0 to 9999, TP/ TON/ TOF type time base: 1 ms, 10 ms, 100 ms, 1 s or 1 mn 16 Up/down counters: Ci, 0 to 9999 4 LIFO or FIFO registers, 16 bits: Ri 4 Drum controllers: DRi, (0 ≤ i ≤ 3) 16 steps
Schedule blocks : RTCi (0 ≤ i ≤ 15) month, day, hour, minute, on PLCs with 16 and 24 I/O MSG message transmission control SBRi shift register bit (0 ≤ i ≤ 3) SCi step by step block (0 ≤ i ≤ 3)
Numerical Instructions
Program Instructions
+, –, /, *, REM: Addition, subtraction, division, mutiplication, remainder division SQRT: Square root INC: Increment DEC: Decrement AND/OR: Word-wise logical operators
END, ENDC, ENDCN: program end (conditional or unconditional) JMP, JMPC, JMPCN: jump to a label (conditional or unconditional) SRn: call to subroutine n (0 ≤ n ≤ 15) RET: subroutine end
100 µs/3 ms/12 ms programmable filter outputs Latching inputs which can be configured (6 inputs) Input for PLC RUN/STOP control Fast counting inputs (10 kHz), frequency meter (5 kHz) or for up/down counting (1 kHz)
Status output at PLC fault PLS pulse generator output (4.9 kHz maximum) PWM Pulse width modulation output (4.9 kHz maximum) Threshhold outputs associated with fast counting.
8
Contact Networks 10 contacts with 1 output per line N/O, N/C, rising and falling edge contacts Direct, inverse, SET, RESET, coils Program jump coils, program call coils
Page 8
Applications
Operator Interface
A display is continuously available to the operator, providing information on the production process. In real time, the user can intervene as soon as an anomaly appears.The operator terminal, connected to the TSX Nano terminal port can: • Display messages stored in the terminal at the request of the PLC • Modify settings (bits or words) stored in the PLC data memory • Receive messages coming from the TSX Nano for display
Programming the Timer
TSX Nanos with 16 and 24 I/O have 16 schedule blocks, for which internal and external outputs can be defined. They enable the user to control outputs directly (to open and close electrical circuits), or to perform operations on a user program according to the time (month, day, hour, minute.) The TSX Nano provides various programming possibilities, such as time references which can be modified via the operator console or calculated by the program, etc. The TSX Nano also enables events to be datestamped and time calculations to be performed by the program. The TSX Nano is suitable for control systems managing lighting, heating or sprinkler systems.
Fast Processing Applications
The TSX Nano includes special functions, which are simple to use and can be easily adapted for control systems which require counting capacity, or call for short response times. • Latching, filtering of 24V DC inputs with user definable parameters (100 µs, 3 ms or 12 ms) • Fast counter (10 kHz max), up/down counter (1 kHz max), with 2 reflex outputs which are controlled directly by the counter function (counting capability 65535 points.)
Pulse Outputs
With the PWM and PULSE software functions, the first output from the TSX Nano can be used as: • Pulse width modulation output in a predefined frequency (19 kHz to 4.9 kHz) for applications with light or sound intensity control (dimmer function) • Pulse generator output (19 kHz to 4.9 kHz) for control of stepper motors When using these functions, it is necessary to use the transistor output models (which have unlimited number of operations.)
9
Page 9
TSX Nano-PLC, Characteristics Configurations Base PLCs
10 I/0 6 Inputs 4 Outputs
16 I/0 9 Inputs 7 Outputs
24 I/0 14 Inputs 10 Outputs
Base PLCs with I/O extension 20 I/0 to 48 I/O 12 to 24 Inputs 8 to 20 Outputs
Characteristics Common Characteristics
100 to 240V AC
24V DC
Supply
Nominal
V
100 to 240 - 50/60 Hz
24V DC
Voltage
Limit
V
85 to 264 - 47 to 63 Hz
DC 19.22 to 30 (ripple included)
Conform to
IEC 1131
–
Yes
Yes
Temperature
Operation
°C
+5 to +60
-25 to +70
Storage Relative Humidity
°C
-25 to +70
-25 to +70
%
5 to 95
5 to 95
115V AC
24V AC
110 to 120
24V DC
Input Characteristics Nominal
Voltage
V
Input
Current mA
10
7
Values
Supply sensors
V mA
– –
24V DC 150
–
Positive or negative depending on wiring
Conforms to IEC 1131 type 1
Resistive conforms to IEC 1131 type 1
Logic –
Input Type Output Characteristics
Relays 24
Positive Logic Protected Transistors
Negative Logic Unprotected Transistors
24V DC
24V DC
Loads
Voltage
V
24V AC to 220,
(Nominal)
Nominal current
A
–
0.5
0.5
Values)
Tungsten lamp
W
–
≤10
≤10
DC Loads
Current
A
DC12 1-24V (0.2 x 106 ops.) DC13 0.4-24V (1 x 106 ops.)
0.625 for U 30 V - common for loads
0.625 for U 30 V + common for loads
AC Loads
AC 12 resistive current
A
AC12 1-110/220V (0, 2 x 106 ops.) 0.5-110/220V 2 x 106 ops.) 1-48V (0.5 x 106 ops.) 2-24V (0.5 x 106 ops.)
–
–
AC15 inductive current
A
AC15 0.22-220V (1 x 106 ops.) 0.45-24/48/110V (1 x 106 ops.) 1-24V (0,2x106 ops.)
–
–
Dimensions, Mounting TSX 072• ••••
Rail mounted AM1-DP or AME-DE
Plate mounted AM1-PA 2 x O4
85 77
60 a Requires 2 plastic plugs
10
G
Page 10
References
TSX Nano PLCs, DC 24V Supply (1) Number of I/O
Inputs
Relay Outputs
24V DC 0.5 A transistor outputs
Version 2 Version 3 Weight Part Number (3) Part Number (3) (kg)
10
6 DC 24V
4 – –
– 4 protected, source 4 unprotected, sink
TSX 0720 1022 TSX 0720 1012 TSX 0720 1002
TSX 0730 1022 TSX 0730 1012 TSX 0730 1002
0.290 0.270 0.270
16
9 DC 24V
7 – –
– 7 protected, source 7 unprotected, sink
TSX 0721 1622 TSX 0721 1612 TSX 0721 1602
TSX 0731 1622 TSX 0731 1612 TSX 0731 1602
0.350 0.325 0.325
24
14 DC 24V
10 – –
– 10 protected, source 10 unprotected, sink
TSX 0721 2422 TSX 0721 2412 TSX 0721 2402
TSX 0731 2422 TSX 0731 2412 TSX 0731 2402
0.400 0.370 0.370
TSX 0720 10••
TSX Nano PLCs, AC 100/240 V Supply (1) Number of I/O
Inputs
Relay Outputs
24V 0.5 A transistor outputs
Version 2 Version 3 Weight Part Number (3) Part Number (3) (kg)
10
6 DC 24V
4 –
– 4 unprotected, sink
TSX 0720 1028 TSX 0720 1008
TSX 0730 1028 TSX 0730 1008
0.300 0.280
16
9 AC 115V 9 DC 24V
7 7 –
– – 7 unprotected, sink
TSX 0721 1648 TSX 0721 1628 TSX 0721 1602
TSX 0731 1648 TSX 0731 1628 TSX 0731 1602
0.390 0.360 0.335
24
14 DC 24V
10 –
– 10 unprotected, sink
TSX 0721 2428 TSX 0721 2402
TSX 0731 2428 TSX 0731 2402
0.410 0.380
TSX 0721 16••
FTX 117 Programming Terminals with Back-Lit 4-line LCD Screen (1)
TSX 0721 1648
Programmable Operations
TLX manual TSX 07 connecting cable, DM 07 117E Length 2 m
Reference
Weight (kg)
Hand Held Terminal
Not Provided Not Provided Not Provided Provided Provided Provided
T FTX 117 0 T FTX 117 07 1 T FTX 117 0 1 E
0.300 0.400 0.665
Weight (kg)
DOS Software Description
Support
Includes
Reference
Software Package Reversible List/ Ladder Language
FTX 417/ FTX 507
1 3" 1/2 diskette 1 RS485 connecting cable 1 installation manual
TLXLPL707F10E (Ver 2) 0.430 TLXLPL707F30E (Ver 3)
IBM PC, IBM PS/2, Comp. PC
1 3" 1/2 diskette 1 RS232 connecting cable (2) 1 user manual
TLXLPL707P10E (Ver 2) 0.440 TLXLPL707P30E (Ver 3)
Miscellaneous Accesories
TSX 0721 24••
T FTX 117 07/117 1
Description
Length (m)
Use
Reference
Weight (kg)
Input Simulator DC 24V
– – –
TSX Nano 10 I/O TSX Nano 16 I/O TSX Nano 24 I/O
TSX 07 SIM 06 TSX 07 SIM 09 TSX 07 SIM 14
0.050 0.070 0.080
Analog Modules
– – – – – –
Analog Input 0-10 V Analog Input 4-20 V Analog Input +/- 10 V Analog Output 0-10 V Analog Output 4-20 V Analog Output +/- 10 V
TSX AEN 101 TSX AEN 102 TSX AEN 105 TSX ASN 101 TSX ASN 102 TSX ASN 105
0.265 0.265 0.265 0.265 0.265 0.265
AC/DC Adapter for FTX 117 Terminal Connecting Cable
– – 0.30 2 5
AC 110/120V AC power supply AC 200/240V AC power supply
T FTX ADC 11 T FTX ADC 12 TSX CAO 003 T FTX CB1 020 T FTX CB1 050
0.260 0.260 0.015 0.100 0.190
Memory Card– Credit Card Format Self Teach
EEPROM – – Including:
T FTX REM 3216 T FTX RSM 3216 T FTX RSM 12816
0.025 0.030 0.030
Documentation (in English)
TSX Nano/FTX 117 user's manual TSX Nano/PC Software user's manual TSX Nano/FTX 117 self teach manual
TLX DM 07 117 E TLX DM 07 DS E MDI TSX 07 1 E
0.265 0.320 0.280
I/O extension FTX 117 <-> TSX Nano FTX 117 <-> TSX Nano 32 K words Protected RAM 32 K words Protected RAM 128 K words 1 TSX 07 (16 I/O), 1 input simulator 1 FTX 117
(1) A multilingual aide pocket reference is included as standard (in English, French, German, Italian, and Spanish). (2) 2m cable equipped with a 9-pin SUB-D male connector at the PC end. (3) Version 3 PLCs and software, available by the second quarter of 1997, have Modbus communication support and support for the 11 Analog Modules. Version 2 applications will be fully compatible with Version 3 hardware and software.
Page 11
Schneider Automation Inc.
One High Street North Andover, MA 01845-2699 USA
Modicon is a Registered Trademark of Groupe Schneider. All other registermarks and trademarks are the property of their respective holders.
12
US Distribution 8000BR9608R11/96 20M11/96NEO