Page 299

Appendix-3 Binary/octal/decimal/hexadecimal/BCD code correspondence table Decimal

APP

Binary

Octal

Hexadecimal

Binary Coded Decimal (4 digits)

0

00000000 00000000

0

0000

0000 0000 0000 0000

1

00000000 00000001

1

0001

0000 0000 0000 0001

2

00000000 00000010

2

0002

0000 0000 0000 0010

3

00000000 00000011

3

0003

0000 0000 0000 0011

4

00000000 00000100

4

0004

0000 0000 0000 0100

5

00000000 00000101

5

0005

0000 0000 0000 0101

6

00000000 00000110

6

0006

0000 0000 0000 0110

7

00000000 00000111

7

0007

0000 0000 0000 0111

8

00000000 00001000

10

0008

0000 0000 0000 1000

9

00000000 00001001

11

0009

0000 0000 0000 1001

10

00000000 00001010

12

000A

0000 0000 0001 0000

11

00000000 00001011

13

000B

0000 0000 0001 0001

12

00000000 00001100

14

000C

0000 0000 0001 0010

13

00000000 00001101

15

000D

0000 0000 0001 0011

14

00000000 00001110

16

000E

0000 0000 0001 0100

15

00000000 00001111

17

000F

0000 0000 0001 0101

16

00000000 00010000

20

0010

0000 0000 0001 0110

17

00000000 00010001

21

0011

0000 0000 0001 0111

18

00000000 00010010

22

0012

0000 0000 0001 1000

19

00000000 00010011

23

0013

0000 0000 0001 1001

20

00000000 00010100

24

0014

0000 0000 0010 0000

21

00000000 00010101

25

0015

0000 0000 0010 0001

22

00000000 00010110

26

0016

0000 0000 0010 0010

23

00000000 00010111

27

0017

0000 0000 0010 0011

24

00000000 00011000

30

0018

0000 0000 0010 0100

25

00000000 00011001

31

0019

0000 0000 0010 0101

26

00000000 00011010

32

001A

0000 0000 0010 0110

27

00000000 00011011

33

001B

0000 0000 0010 0111

28

00000000 00011100

34

001C

0000 0000 0010 1000

29

00000000 00011101

35

001D

0000 0000 0010 1001

30

00000000 00011110

36

001E

0000 0000 0011 0000

31

00000000 00011111

37

001F

0000 0000 0011 0001

63

00000000 00111111

77

003F

0000 0000 0110 0011

255

00000000 11111111

377

00FF

0000 0010 0101 0101

9999

00100111 00001111

23417

270F

1001 1001 1001 1001

65535

11111111 11111111

177777

FFFF

Appendix・10

Page 300

Appendix-4 JW-13PG key operation Below shows operation procedure to

Mode use JW-13PG for the JW10. Function

P: Program mode M: Monitor mode C: Change mode

T: Terminal mode I: Initial mode Mode

Operation procedure

P M C T I Buzzer ON/ OFF select

(ON)

EL backlight ON/OFF select

(ON)

Contrast adjustment

(Darker)

○○○×○

(OFF)

○○○×○

(OFF)

○○○×○

(Brighter)

Auto repeat function

Monitoring of program address or data memory address

1 second or longer ON 1 second or longer ON

Display mode selection

1PG mode

2PG mode

Repetition of address +1. Repetition of address -1.

○○○××

○○○×× (Program mode) (Monitor mode)

Operation mode setting

(Change mode)

Program mode

○○○×○

(Initial mode)

3rd

EL backlight ON/OFF

○○○×○

Buzzer ON/OFF

○○○×○

Monitor clock (JW-1424K/1624K)

○○○××

Error monitor

×○○××

Display mode selection

○○○××

Initial mode

○××××

Monitor mode

○○○×○

Change mode

○○○×○

Program mode

○○○×○

1st

2nd

4th

Operation screen selection

Key operation

5th

6th

7th

Program check

Appendix・11

○××××

APP

Page 301

Function

Mode

Operation procedure

P M C T I

System memory clear

Program memory clear

Memory clear

○××××

Data memory clear

Program memory and data memory clear

All initialize

(Read in address incrementing direction)

System memory read

System memory write

Set the system memory address

System memory write

○○○××

(Read in address decrementing direction)

(1 byte unit)

Set data HEX, OCT, DCML, bit pattern

○××××

(1 word unit)

System memory check code write

○××××

Program address set

APP

Basic and application instruction entry

Entry method for basic instructions

○○○××

Address set

Instruction key

Relay number

Setting value

TMR/CNT number

TMR/CNT instruction entry

Setting value changes constants or register area by pressing

0000 コ0000 (Constant)

b000

09000

○××××

• F-xx instruction Function number

• Fcxx instruction

Application instruction entry key.

F-××(Fc××)

F-××w(Fc××w)

Function number

Register/constant

(Repetition of number of instruction word setting)

Appendix・12

Page 302

Function

Mode

Operation procedure

P M C T I

Basic and application instruction entry

• Press the

Register area selection

コ0000

Indirect address designation

Register number

Setting the register address key to change the register area.

b000

09000

@Register number ○××××

Display コ0000

Address

Display b000

Address Register number set (0 to 3)

Display 09000

Address

• Write from address 00000 Instruction word

• Write from a specified address Program write

Instruction word

Program address set

○××××

• Write from an address where no program is written

Search for NOP instruction

Instruction word

• Read by specifying an address Program address setting

(Read in address incrementing direction) (Read in address decrementing direction)

• Read by searching for an instruction

Program read

Instruction search

(Read in address incrementing direction) (Read in address decrementing direction)

• Read by searching data memory Data memory search

(Read in address incrementing direction) (Read in address decrementing direction)

Appendix・13

○○○××

APP

Page 303

Function

Mode

Operation procedure

P M C T I Specify search start address

Specify instruction to be searched for.

Address incrementing direction

Instruction search

○○○××

Address decrementing direction

Continuous search

○○○××

(Increment address)

Specify search address

Non-NOP instruction search

Program search

(Increment address) (Decrement address)

Specify search address

NOP instruction search

(Decrement address)

○○○××

Continuous

Data memory address set

(Address incrementing direction)

Data memory address

Data memory search

(

)

Address decrementing direction

○○○×× • Press the key to change the data memory area.

Relay number (00000 to 15777)

TMR/CNT number (000 to 377)

Byte address (コ0000 to コ1577)

Label number (LB0000 to LB0177)

Byte address (b000 to b777)

Register (09000 to 39777)

Searching with the changed contents (Address incrementing direction) Instruction search

Re-execution of search

Program correction

Data memory search

(

)

Address decrementing direction

Searching with the contents before the change (Address incrementing direction)

(

○○○××

)

Address decrementing direction

APP

Program correction

(Continuous search)

Instruction change

Specify address to be corrected

Specify instruction to be corrected

○××××

Instruction insert

Specify address to be inserted

Specify instruction to be inserted

○××××

Instruction delete

Read the instruction to be deleted

○××××

Appendix・14

Page 304

Function

Mode

Operation procedure

Program correction

P M C T I TMR/CNT setting value change

Read setting value in program

Application instruction constant change

Program address search

○×○××

Setting value change

Setting value change

○×○××

Continuous check

Program check

○××××

(Address incrementing direction) (Address decrementing direction)

Setting program address

Program monitor

Instruction search

×○○××

Data memory search

Continuous monitor Setting data memory address (Address incrementing direction) (Address decrementing direction)

Data memory monitor

Press the key to change the data memory area.

Relay number TMR/CNT number (00000 to15777) (000 to 377)

Byte address (コ0000 to コ1577)

Byte address (b000 to b777)

○○○××

Register (09000 to 39777) Display コ0000

Address

Display b000

Address

Display 09000

Register number set

Address

Data memory change

(0 to 3)

Relay set or reset

Relay monitor

(Set)

○×○×× (Reset)

TMR/CNT set or reset

TMR or CNT monitor

(Set)

××○×× (Reset)

Current register value change

Register monitor

Current value

Appendix・15

○×○××

APP

Page 305

Function

Mode

Operation procedure

P M C T I Change to initial mode

Change to program mode

(Select clock)

Set the "year"

Set the "month"

Set the "day"

(Lower 2 digits of A.C.)

××××○ Setting the time (JW-1424K/ 1624K)

Set the "day-ofthe-week"

Set the "hours"

Set the "seconds"

Set the "minutes"

Day of the week SUN MON TUE WED THU FRI SAT Setting 0 1 2 3 4 5 6 value

(Monitor) Time monitor

○○○×× Clear the monitor with the key. (Write)

Writing a program to an EEPROM

○××××

(Stop)

Reading a program from ROM

(Read)

○×××× (Stop)

(Step incrementing direction monitor) (Step decrementing direction monitor)

Error monitor

×○○××

Password register (4 digits)

Password register

(Register)

(0 to F)

Password delete

(Delete)

Secret ON

(ON)

○××××

(Stop)

○××××

(Stop)

○××××

(Stop)

APP Secret OFF

JW-13PG is connected with JW10's MMI port

Password (4 digits) (Secret OFF)

(0 to F) All initialize

Clear the system memory, program memory, and data memory

(

Appendix・16

)

○○○××

Page 306

Appendix-5

Connection with an LCD control terminal

Below shows wiring method and setting value of the system memory when a SHARP's LCD control terminal (ZM-30E/L, ZM-40D/L, ZM-61E/T, ZM-70D/T) is connected to the JW10.

[1] In case of connecting communication port (1) Wiring ZM-30E/L

ZM-40D/L

CN2

ZM-61E/T, ZM-70D/T

CN2

CN1

TB2

Shielded twisted pair cable

Signal Signal Terminal Signal name Pin no. name Pin no. name Pin no. name

+RXD +TXD -RXD -TXD FG

10 12 11 13 1

+RD +SD -RD -SD FG

24 12 25 13 1

24

+RD +SD -RD -SD

12 25 13 1

FG

JW10 communication port Terminal name

+RD +SD -RD -SD

L1 L2 SHLD

FG

Note 1: Connection to a ZM-30E/L, ZM-40D/L, or ZM-61E/T can be done on models with version 1.13 or later ROM code. Note 2: The termination resistance switches on the ZM-40D/L, ZM-61E/T, or ZM-70D/T must be set to "No termination resistance." If they are set to " termination resistance present," the JW10 may not communicate correctly. (2) Setting of JW10 system memory Setting System Contents value memory no. #234 00(H) Computer link mode #236 30(H) 19200 bits/s, even parity, stop bit 2 bits, data length 7 bits #237

001(8)

Station No. 001

(3) Setting of screen image creation software (ZM-31SE) Setting contents

Item SHARP (JW series)

Setting PLC model

Communication parameter Baud rate [19200] bps., signal level [RS422]

[2] In case of connecting with MMI port (1) Wiring ZM-30E/L

ZM-40D/L

CN2

CN2

ZM-61E/T , ZM-70D/T CN1

TB2

Signal Signal Signal Pin no. Terminal name name Pin no. name Pin no. name

+TXD -TXD +RXD -RXD FG

12 13 10 11 1

+SD -SD +RD -RD FG

12 13 24 25 1

+SD -SD +RD -RD FG

12 13 24 25 1

+SD -SD +RD -RD FG

Shielded twisted pair cable

JW10 MMI port Pin no.

Signal name

2 7 3

RX /RX TX /TX PG/COM GND

8 4 5

Note 1: The termination resistance switches on the ZM-40D/L, ZM-61E/T, or ZM-70D/T must be set to "No termination resistance." If they are set to " termination resistance present," the JW10 may not communicate correctly. Appendix・17

APP

Page 307

(2) Setting of JW10 system memory System memory no.

Setting value

#226

30(H)

19200 bits/s, even parity, stop bit 2 bits, data length 7 bits

#227

001(8)

Station number 001(8)

Contents

(3) Setting of screen image creation software (ZM-31SE) Setting contents

Item Setting PLC model

SHARP (JW series)

Communication parameter Baud rate [19200] bps., signal level [RS422]

APP

Appendix・18