[5] Error and treatment

You can see the self-diagnosis results by the indicator lamp. See page 95 for position of indicator lamp.

‘oa Display meaning Lighting condition Reset method RUN In operation Slave station normal operation _ - Slave station switch setting error Set slave station switch again. Communication error Check Communication Cable. ERROR Error PC stopping Operate PC. Slave module defective Replace slave module. Input indicator | Comes ON when the input signal to the IN 0 to 7 lamp slave module is "ON." OUT0to7 | Output indicator | Lights when output signal from PC is (ZW-162MC) lamp "ON", Fuse wa (ZW-162MC) Fuse A fuse on the output circuit is blown. Replace slave module. Operation Indicator lamp Reset Priority description In operation | Error Input Output 0 to 7 method order RUN ERROR| Oto7 (ZW-162MC) c | Turn OFF output Changes due to GQ | prohibition switch e signal from PC Ee, 4 28 | Turn ON output e ° | prohibition switch Save module @ “ON", | Allpoints "OFF" | Replace slave module 1 3 | Switch setting e input Set address switch ® |error signal again. a °o _, 2 E conended @ e PC operation 9 Holding state 2 | Communication before abnormality | Check communication error ad 0 cable. 3 (output only) Replace slave module

@: Lighting, @: Blinks

~ 103 -

Page 111 read from a scan by OCR; it may hold reading errors

[6] Specifications

(1) General specifications

Item

Specifications

Allowable power voltage

24 VDC (+10%, -15% : Ripple factor; less than 5%)

Power consumption current

ZW-84NC : 100 mA Max, ZW-162MC : 110 mA Max

- Current from 24 V power terminal (pin 1) of the input/output connector is not included.

- Total current consumption supplied from the 24 V power terminal (pin 1) should be 1 A max.

Storage temperature

-20 to +70°C

Ambient operation temperature

0 to +55°C

Vibration resistance

Conforming to JIS-C-091 1

10 to 57 Hz with single duplicate 0.075 mm. 57 to 150 Hz at constant acceleration 9.8 m/s? (1 G)

(2 hours each in X, Y, Z directions)

Shock resistance

Conforming to JIS-C-0912 147 m/s? (15 G) (3 times each in X, Y, Z directions)

Withstand voltage

1000 VAC for one minute (between input/output terminal, power terminal and secondary circuit)

Insulation resistance terminal and secondary circuit)

500 VDC, more than 10 M-chm (between input/output terminal, power

Insulation system

Photo-coupler

Protection structure iEC standard IP67 (Dust-proof, splash-proof type)

Weight

Approx. 660 g

Accessory

One instruction manual

(2) Communication specifications

Item

Specifications

Data transfer rate

EIA RS485 or equivalent

Transfer rate

345.6 k bits/s, 172.8 k bits/s (automatically changes according to the data transfer speed of master station.

Transfer format

Asynchronous system

Coding method

NRZ (Non Return to Zero)

Frame check

Parity check and reverse-double verification

Synchronous mode

Asynchronous

Transfer mode

Time sharing cyclic digital system

Communication line

Wires

Parity line: Shielded twisted pain cable Cable total length : 1 km max. Recommended cable type: MRC-SB-5C by Nichigo Tsushin

Connection with external! lines

Plug connection (plug itself is not supplied) Recommended plug: Tajimi wireless electric For input (socket); TRC02-16P 7FA-011.2 For output (pins); + TRC0O2-16P 7MA-9@11.2, 104 -

Page 112 read from a scan by OCR; it may hold reading errors

(3) Specifications of /O

@ ZW-84NC (24 VDC input module)

item Specifications No. of slave station occupied bytes | 1 bytes No. of input point 8 points Rated input voltage 24 VDC Allowable input voltage | 20.4 to 26.4 VDC

Rated input current

4.6 mA TYP. (at 24 VDC)

input voitage level

ON level: 18.0 V or less, OFF level: 8.0 V or more

Input current level

ON level: 3 mA or less, OFF level: 1.5 mA or more input impedance

5.2 k ohm TYP.

Surge current

Response time (module alone)

OFF, ON: 1.0 ms or less

ON, OFF: 1.5 ms or less

Common terminal

1 common per 8 points

Operation indication

Light LEDs at ON

External wire connection system

Round water-proof connector for sensor. One connector for one input. (Connectors for externa! connections are not supplied.) Specified connector: IEC standard M12, 4 cores, DC use, male, with gold plated terminals.

Circuit configuration

Comunication’ power connector {IN) 1A oXo4 - - - H] cava /]

Comunication power connector (OUT}

Grounding terminal

Photo-coupler

24V Input connector {0)

ace)

Photo-coupler

1

{ 1 ' 1 1 1 1 1 1 ' {

2avor

2

Input connector (7} 3 ov Input “4

3 RD

Internal circuit

Input 0

Input 7

Input indicator lamp

Le

Input indicator larry p

Ez, 105 -

Page 113 read from a scan by OCR; it may hold reading errors

@ ZW-162MC (transistor output, 24 VDC input module)

Item

Specifications

No. of slave station occupied bytes

2 bytes (Output : Front 1 byte, Input : Back 1 byte)

No. of output point 8 points Rated load voltage 24 VDC Allowable load voltage 20.4 to 26.4 VDC

Rated max. output power

0.3 A/point, 1 A/common *X 1

Surge ON current

Output element capacity: 2 A (100 ms)

Min. load current

(Module alone)

5 Leakage current (when OFF) 0.05 mA or less 8 ON voltage 0.5 V or less (0.3 A) 3 Response time OFF, ON: 1 ms or less > | (module alone) ON, OFF: 1 ms or less (resistance load) 2 3 | Surge killer Zener diode a Rated fuse Built-in 1.25 A fuse (unable replacement) Meltdown detection function is provided (When melted down or lead power is turned off, the FUSE lamp lights) Note : This fuse protects against abnormal heating, and burning out the module. It is not for overcurrent protection of the output elements or load. Common terminal 1 common per 8 points ( - common) No. of input point 8 points Rated input voltage 24 VDC Allowable input voltage 20.4 to 26.4 VDC (includes ripple factor at 12/24 VDC} S | Rated input current 4.6 mA TYP. (at 24 VDC) rs Input voltage level ON level: 18.0 V or less, OFF level: 8.0 V or up = | Input current level ON level: 3 mA or less, OFF level: 1.5 mA or up 2 Input impedance 5.2 k ohm (TYP.) + ~+| Surge current, €& | Response time OFF, ON: 1.0 ms or less (24 VDC)

ON, OFF: 1.5 ms or less (24 VDC)

Common terminal

1 common line for 8 points (no polarity)

External wire connection system

Round water-proof connector for sensor. One connector for one input. (Connectors for external connections are not supplied.) .

Specified connector: IEC standard M12, 4 cores, DC use, male, with gold plated terminals.

When you supply load power from the input/output connector, make sure that the total internal consumption current (110 mA), current for the 3-line external sensor, and load current are be less than 17 A.

When you use an inductive load, the time delay from ON to OFF may be more than one second with a load value OFF.

~ 106

Page 114 read from a scan by OCR; it may hold reading errors

ltem Specifications SHIELD! Communication’ power connector (IN) tA T\oy - - P| deme. |}, converter = Lu Ld 5 £ oO, SHIELD wo Communication’ Cc power connector (OUT} ®, = Grounding FG 3 1.25A terminal Input indicator . ., Photo-coupter lamp Circuit configuration Input connector) | OPN Inputo _ Input 4 AA;, Output indicator mI Photo-coupler lamp ' wr ‘ Ye Output 0 Le t t we 4 ‘ 4 t 1 4 1 : ' ' 1 , ’ 1 7 ' 1 1 { ’ 1 , , 1 1 ' 1 , ' ’ ! 1 ' 1 1 , , 1 1 1 , 1 1 ' ' , 1 1 ' 1 1 1 ( 1 i i ' t 1 ' Input indicator Phot I lal save! joto-coupler mp Output 62 Input connector {7) ov’ 3 Input 7 Le Input 4 NA; Output indicator Photo-coupler lamp we Output 7 te ws

(4) External dimension drawings (Common for ZM-84NC/ZW-162MC)

120 min.

Me

75

Ea Ee Eh Se Eh Gl Ea input/output cables

\

80 min.

cy e

Lo= - =a]

Communication/power cables

~ 107 -