Page 1 of I/O link master module JW-31LMH Instruction Manual

Manual · Sharp

I/O link master module JW-31LMH Instruction Manual

Manual123 pagesPDF 3.3 MB

Instruction manual for the Sharp JW-31LMH I/O link master module and its ZW-series I/O link slave modules for W series PCs.

Download the PDF3.3 MB

Covers · 1 model

The models it covers

Summary

What is in it

Sharp's instruction manual for the JW-31LMH I/O link master module, which fits an I/O slot of a W series programmable controller and links remote input and output slave modules over a single RS-485 cable. It covers system configuration, master module specifications, installation and wiring, switch settings, monitoring and error handling, transfer time and timing, a program example, and the ZW-series slave modules (ZW-82N/82S, ZW-161N to ZW-162M, ZW-164NH, ZW-324NH, ZW-84NC/162MC) with their own wiring and specifications.

Its parts

  1. Preface
  2. Safety precautions
  3. System configuration
  4. Master module specifications
  5. Name of function of each part
  6. Installation/wiring
  7. I/O link usage
  8. Monitor I/O link operation
  9. Required transfer time and communication timing
  10. Program examples
  11. Slave module

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Sharp instruction manual, version 1.0 from March 1998, for the JW-31LMH I/O link master module, which fits a Sharp W series programmable controller and links remote input and output modules over one RS-485 cable. It also covers the I/O link slave modules ZW-82N/82S, ZW-161N/162N/161S/162S/164S/162M, ZW-164NH/162SH/162MH, ZW-324NH/322SH/322MH and ZW-84NC/162MC. It explains installation, wiring, switch settings, status data, error indications and troubleshooting.

Read for this summary: pages 1 to 4, 7 to 25, 34 to 39 and 115 of 123.

Device type
I/O link master module that replaces PC I/O wiring to remote inputs and loads with one communication cable p. 8
Compatible PCs
JW-50CU, JW-50CUH, JW-70CU, JW-70CUH, JW-100CU, JW-100CUH p. 9
Capacity
Up to 32 slave stations; max. 504 I/O link points (63 bytes) p. 15
Transfer speed
345.6 k bits/sec, or 172.8 k bits/sec for older slave modules; set by S/H on switch SW2 p. 8, 15
Network
EIA RS-485 or equivalent, shielded twisted pair cable, 1 km total length max. p. 15
Data exchange time
About 13.1 ms for 504 I/O link points at 345.6 k bits/sec p. 8
Power and weight
300 mA (5 VDC); approx. 370 g p. 14
Environment
Operation 0 to +55°C; storage -20 to +70°C; 35 to 90% RH without condensation p. 14
PC resources used
16 I/O relay points (2 bytes) and a 64-byte data register area p. 15
Terminal block
8 P terminal block (M 3.5 X 7 screws) p. 15
Indicators
COMM, MODE 3, ERROR, FAULT, CHECK, HALT lamps; 7-segment display of error code or error slave station p. 15, 16
Setting switches
SW1 I/O link bytes, SW2 mode, SW3 termination resistance, SW4 CHECK p. 16
Communication modes
Three modes, chosen on SW2; mode 3 confirms recovery manually p. 9, 16
PC error codes
40 installed module check, 42 output data check error, 44 I/O data bus error, 45 I/O signal error, 46 special I/O error; stored at system memory #0160 p. 37

What this manual walks you through

  • Installing the master module in the rack panel p. 17
  • Wiring the communication cable to the master and slave stations p. 18, 19, 20, 21
  • Using the CHECK and HALT relays p. 22, 23
  • Data register layout for slave station data p. 23, 24
  • Setting the number of I/O link bytes on SW1 p. 25
  • Reading the status byte and error information p. 34, 35
  • Finding the slave station with an error p. 36
  • Module behavior when the PC stops, errs or loses power p. 37, 38
  • Troubleshooting with the I/O link check flow p. 115

Good to know

  • DIP switches on the master and slave modules are set only with the power off. p. 10
  • The master module cannot go in slots already fitted with option cable ZW-2CC, ZW-4CC or ZW-6CC. p. 17
  • With any low speed slave module connected, the transfer speed is set to 172.8 k bits/s. p. 13
  • Short pulse signals may be missed; safety-related inputs go directly to the PC. p. 10
  • Communication errors are detected only from input module data. p. 36

Questions this manual answers

How many slave modules can a JW-31LMH control?

Up to 32 slave modules with at most 504 I/O link points, over a total cable length of up to 1 km. p. 8

What does the FAULT lamp on the JW-31LMH mean?

It shows an error of the master module itself; the manual says to replace the master module. p. 36

How do I see which slave station has an error?

Turn on both the HALT and CHECK relays; the master module displays the error station address, lowest first when there are several. p. 36

Which Sharp PLCs take the JW-31LMH?

The JW-50CU, JW-50CUH, JW-70CU, JW-70CUH, JW-100CU and JW-100CUH. p. 9

What speed is used with older ZW-82N or ZW-161N slave modules?

172.8 k bits/sec, set by turning OFF S/H on switch SW2. p. 8, 13

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Cover1
  2. Introduction2
  3. Safety Precautions3
  4. §1 Preface8
    1. 1-1 I/O link8
    2. 1-2 Features8
  5. §2 Safety precautions10
  6. §3 System configuration11
  7. §4 Master module specifications14
    1. 4-1 General specifications14
    2. 4-2 Specifications of master module15
  8. §5 Name of function of each part16
  9. §6 Installation/wiring17
    1. 6-1 Installation method17
    2. 6-2 Wiring method18
  10. §7 I/O link usage22
    1. 7-1 Setting at master module side22
    2. 7-2 I/O link module setting procedure28
    3. 7-3 Cautions concerning I/O link setting33
  11. §8 Monitor I/O link operation34
    1. 8-1 Monitor master module operation34
    2. 8-2 Operation in error conditions37
  12. §9 Required transfer time and communication timing40
    1. 9-1 Required transfer time40
    2. 9-2 PC processing and communication timing41
    3. 9-3 Minimum scan time of the PC46
  13. §10 Program examples47
    1. [1] System configuration47
    2. [2] Switch setting of modules47
    3. [3] Data memory allocation48
    4. [4] PC program49
  14. §11 Slave module50
    1. 11-1 ZW-82N/82S51
    2. 11-2 ZW-161N/162N/161S/162S/164S/162M62
    3. 11-3 ZW-164NH/162SH/162MH78
    4. 11-4 ZW-324NH/322SH/322MH92
    5. 11-5 ZW-84NC/162MC101
  15. §12 Appendix115
    1. 12-1 I/O link check flow115
3 more lines, from page 116 on
  1. 12-2 Data register address change of JW special I/O module116
    1. 12-3 Adress allocation table slave module(Master module:JW-31LMH)122
  2. Back cover123

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Table of Contents5-7
  3. Pages 8 to 108-10
  4. §3 System configuration11-13
  5. Pages 14 to 1614-16
  6. §6 Installation/wiring17-21
  7. §7 I/O link usage22-33
  8. §8 Monitor I/O link operation34-39
  9. §9 Required transfer time and communication timing40-46
  10. §10 Program examples47-49
  11. §11 Slave module, pages 50 to 5950-59
  12. §11 Slave module, pages 60 to 6960-69
  13. §11 Slave module, pages 70 to 7970-79
  14. §11 Slave module, pages 80 to 8980-89
  15. §11 Slave module, pages 90 to 9990-99
  16. §11 Slave module, pages 100 to 109100-109
  17. §11 Slave module, pages 110 to 114110-114
  18. Pages 115 to 123115-123

The file

Revision and size

RevisionVersion 1.0, Mar. 1998
PublisherSharp
Pages123
PDF3.3 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 123

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 123
Page 2
Page 2of 123
Page 3
Page 3of 123