For the Sharp ZW-32IO2 and Sharp ZW-32S2T
Page 39
[3] DIP switch
DIP switches SW2-1 and SW2-2 are found on the CPU board in the control module. Set them to match the application of the PC.
* For the JW-50CU/70CU/100CU
Slot screwdriver
Switch setting table Switch setting table ZW-V/O JW-I/O ZW-I/O JW-I/O All OFF | Output | Output All OFF | Output | Output hold hold hold hold SWe2-1] OFF ON ON SW2-1| OFF OFF* ON SW2-2} OFF | OFF | ON SWe2-2| OFF | ON* ON
*: Difference with JW-50CU/70CU/100CU
(1) Description of switch settings (Output hold and all points OFF selection Selects the operating state of the output circuit when the CPU halts. (Set the switches according to the type of control module.)
Control module JW-50CU/70CU/1 00CU | JW-50CUH/70CUH/100CUH : aa SW2-1 Swe2-2
ON Output hold Retains the address area set in system | * Factory setting at memory #0232 and #0233. delivery : ON OFF All points OFF
Note: Be sure to set the switch to ON (output hold) when using the JW-I/O module.
(2)VO module type selection Selects the type of I/O module used with the PC. (Set the switches according to the type of control module.)
| JW-50CU/70CU/100CU | JW-50CUH/70CUH/100CUH SW2-2 SW2-1 pti erpuer * Factory setting at ON JW-I/O module in use . ; - delivery : ON OFF ZW-1|/O module in use
At
Page 40
(2) Monitoring the switch settings The switch settings are stored in system memory #0042 and can be monitored using a support tool such as the support tool. 7 6 5 4 3 2 1 0
#0042
/O module selection switch Output hold switch
Memory protect switch
[_]: ON(indicates switch is ON) BB. OF F(indicates switch is OFF)
Refer to the instruction manual of each support tool for the monitoring procedure.
[4] Outline dimensions drawings Approx. i 20 {4} Onmm Oruat
>
ET ie my
106 . 110(include rack panel)
150, - #| Approx.| >
30
(Unit: mm)
Note 1: These dimensions refer to the front edge of the rack panel. Note 2: The drawings above are for the JW-70CU/100CU and JW-70CUH/100CUH control modules.
Page 41
[5] Performance specifications
Progam method Stored program method Control method Cyclic operation method and interupt processing method Basic instructions (except for the TMR, CNT, MD, 0.38 «s/instruction 0.25 yz s/instruction*Note 2 and application Proce- instructions) ssing Application instru- speed tions TR Avrage a few microseconds/instruction (Note 1, 2) CNT and , (JW-50CUH/70CUH/1O00CUH process approximately 1.5 times MD instruction as fast as JW50H/70H/100H.) [Basic 20 kinds Instruction | instructions type Application instructions 116 kinds 157 kinds JW-50CU, JW-50CUH: 7.5K words max. (standard installed) RAM JW-70CU/100CU, JW-70CUH/100CUH: 7.5K to 63K words (optional) Program JW-50CU, JW-50CUH: 7.5K words max. (27C512X1) memory EPROM JW-70CU/100CU, JW-70CUH/100CUH: 31.5K words max. capacity (27C512X1) JW-50CU, JW-50CUH: 7.5K words max. (28C256 X1) EEPROM JW-70CU/100CU, JW-70CUH/100CUH: 15.5K words max. (28C256X1) Internal lithium battery (DUNT-5784NCZZ) backs up RAM Memory backup contents. Operation on ROM without battery backup is possible by setting address #0225 of the system memory.
/O control | For JW-l/Os | Batch refresh method and refresh method by instruction method For ZW-I/Os | Batch refresh and method
No. of JW-50CU, JW-50CUH: 512 points max. 0) JW-70CU, JW-70CUH: 1024 points max. JW-I/Os| points JW-100CU, JW-100CUH: 4096 points max. No. of No. of ’ 8 rack panels max. One modules P points No. of JW-50CU, JW-50CUH: 512 points max. ZW-1/Os| I/O JW-70CU, JW-70CUH: 1024 points max. points JW-100CU, JW-100CUH: 2048 points max.
Note 1: For the execution speed of each instruction, refer to the "Instruction list” in the programming manual.
Note 2: The processing speed of JW50H/70H/100H can be set for the same speed as JW50/70/100 by setting the memory module switch.(See page 4-20}.
Page 42
Data memory
1/0 relays
The latched relay area can be expanded or reduced in an 8-point increment by setting the system memory addresses #0230 and #0231 (to allow the last output status to be held at power failure.)
2048 points(00000 to 03777)
Auxiliary relay
1536 points (04000 to 06777)
Latched relay
224 points (07000 to 07337) {addresses 07300 to 07337 are used for the ZW/JW-10CM link module). 256 points (04000 to 07777)
Special relay
32 points (07340 to 07377)
Non-carry flag (07354)
Error flag (07355)
Carry flag (07356)
Zero flag (07357)
0.1 sec.clock (07360)
Initialize pulse (07362)
Output module fuse blown (07362) *Note 2 1.0 sec. clock (07364)
DIP switch (07365)
Normally OFF contacts (07336) Zero-cross switch (07367}
Memory error (07370)
CPU error (07371)
Battery error (07372)
/O error (07373)
Option error (07374)
Special 1/O module error (07375) *Note 2 Expansion power supply error (07376) *Note 3 Power supply error (07377)
Error code stored (07340 to 07347)
General- purpose relay
3072 points (10000 to 15777) used as link relay etc. (latched relay available)
TMR/CNT time limit contacts
512 points {T or C000 to C777)
1024 points (T or C0000 to C0777, T or C1000 to C1777)
TMR/CNT/MD mm number: Timer number: . ; 100 ms timer (TMRO0000 to 1777) | mm timer (TMRO00 to | 49 ms timer (TMR0400 to 0777)
Total of 1024 points (0000 to 1777)
Total of 512 points (000 to *Note 4
The setting value of a timer, coun- ter and MD can be specified in a register. *Note 5
10 ms timer (TMR700 to 777)
Timer setting time: 100 ms timer; 0.1 to 3276.7 sec. (BIN)
; 0.1 to 799.9 sec. (BCD)
10 ms timer; 0.01 to 19.99 sec. (BCD)
Counter setting value: 1 to 32767 (BIN), 1 to 7999 (BCD) MD setting value: 0 to 999 The current values of the counter and MD are retained on power failure. The current timer data can be either reset or retained on power failure at user's choice. Timer function is user-selctable in 10ms increments.
Registers
5120 bytes (backup at battery failure)
09000 to 09777, 49000 to 49777, 89000 to 89777 19000 to 19777, 59000 to 59777, 99000 to 99777 29000 to 29777, 69000 to 69777
39000 to 39777, 79000 to 79777
4-14
Page 43
Note 1: The maximum number of control I/O points differs from on model to another. The remaining I/ O relay area can be used for auxiliary relays. JW-50CU, JW-50CUH: 01000 to 03777 JW-70CU, JW-70CUH: 02000 to 03777 If more than 2048 I/Os are required, convert the auxiliary, latch, and general purpose relays into 1/O relays.
Note 2: Available only for JW-series I/Os.
Note 3: Available only if the /O bus expansion adapter is used.
Note 4: System memory #0201 can be used to set the number of contacts either 512 or 1024. If 1024 points are set, T or C1000 to C1777 are shared with general purpose relays 13000 to 14777.
Note 5: See the description of application instructions F-260, Fc260, F-261 and Fc261 in the programming manual.
4-15
Page 44
File register
JW-50CU, JW-50CUH: 16K bytes
(file 1)
JW-70CU/100CU, JW-70CUH/ O00CUH When using ZW-1MA and JW-1MAH: 16 kbytes (file 1) When using ZW-2MA and JW-2MAH: 64 kbytes (file 1)
When using ZW-3MA and ZW-3MAH: 128 kbytes (file 1, 2) When using ZW-4MA and ZW-4MAH: 448 kbytes (file 1 to 7)
Areas used by link module (ZW-10CM, JW-710CM)
[Areas for data link] Initial sequence computer flag (07305) Data link operating (07304, 07307) [Areas for remote I/O] Remote I/O operating (07316) Individual remote I/O flags (15771 to 15777) [Area for computer link]
Format errors (07310, 07313) Output relays (07311, 07314) Trigger contacts (07312, 07315) Global address command complete (07317)
Output format's first address storage area (19750, 19751, 19754, 19755) Data memory's first address storage area (19752, 19753, 19756, 19757)
Data memory
Second 99770 Contents of control code 99777 ; Minute 99771} Contents| D7 | D6 D Areas for storing] Hour 99772 _ 5 t real-time Date 99773] ON [ime corre- Stop clock's present | Month 99774 Not used (ction Not | clock ne Year 99775] Oe Time | used fois ote Day 99776 monior clock Control code 99777 E0000 7 to Port 7 Error 8 00 Second - E0177 01 Minute Eor00 Port 6 E > 02 Hour E0377 ° ror 03 Date E0400 04 Month to Port 5 Error 6 E0577 ee | 05 Year ; to Port 4 Error 5 Error history E0777 07; Error code storage area E1000 19| Faulty port, slot, *Note 2 to Port 3 Error 4 rack panel E1177 11 Error count E "200 12| Reserved (e) Port 2 E 3 E1377 ° ror 13} Reserved E400 14 Reserved ce) E1577 Reserved Error 2 15 Reserved E1600 16| Reserved to Control module Error 4 E1777 17 Reserved
Note 3: When an error occurs, the real-time clock is reset to 24-hour representation.
Note 1: In a contro! module with no battery, the real-time clock start with OOH: OOM: 00S, 00 year 00 month 00 day at power ON. Note 2: The address range E0000 to E1577 is assigned as an error history storage area of variable size that depends on the number of installed option modules. The areas assigned to uninstalled option module are available as general-purpose registers.
4-16
Page 45
System memory
Addres.
Function
#0010 to #0017
Clock feature
#0020
User program EEPROM area
#0030 Minimum scan time monitor (lower BCD digit)
#0031 Minimum scan time monitor (upper BCD digit)
#0032 Current scan time monitor (lower BCD digit)
#0033 Current scan time monitor (upper BCD digit)
#0034 Maximum scan time monitor (lower BCD digit)
#0035 Maximum scan time monitor (upper BCD digit)
#0036 Last I/O address monitor ©C)) ;
#0042 ID code monitor of the installed memory module
#0046 I/O address monitor where an error was detected (0c) #0050 Error slot number monitor
#0052 Error address monitor on user program (lower octal digit} #0053 Error address monitor on user program (upper octal digit) #0054 Error address monitor on user program (file number) #0160 to #0167 Error codes obtained from self diagnosis
#0170 to #0177
Option error codes
#0201
Specifies the TMR reset condition
#0202 Specifies the CNT reset condition
#0204 Specifies the program memory capacity
#0205 Specifies fite register capacity (file No.1)
#0206 Specifies continue/stop operation upon detection of a fuse failure
#0207 Specifies continue/stop operation upon detection of an option error
#0210 to #0222
ZW-10CM, JW-10CM: Area used by a remote I/O master station manual! allocation
#0223 Selects clock functions
#0224, #0225 Specifies the use of comment memory
#0226 Specifies scan time
#0227 Selects 10ms timer functions
#0230 Sets latched relay area (lower octal digit)
#0231 Sets latched relay area (upper octal digit)
#0232 Specifies the output holding address (lower octal digit) #0233 Specifies the output holding address (upper octal digit)
#0236,#0237
Sets the commniation port's mode
#0241 to #0243
Sets interrupt inputs (JW)
#0244
Enables/disabies data write into file memories (files 1to 7)
#0246 Extends voltage interruption detction interval
#0247 Selects either automatic or manual registration of I/O addresses.
#0250 Specifies the total number of bytes used by I/O modules (ZW)
#0252 Specifies the I/O address self-test feature (ZW)
#0255 Specifies battery-less operation
#0256 Selects ROM type
#0260 to #0377
Specifies parameters for the ZW-10CM, JW-10CM data link master station
Note 1: The JW and ZW given in parentheses denote the functions and for the JW-I/Os and ZW-I/Os respectively.
4-17
Page 46
System memory
Address Function
#0660 to #0757 The number of dummy I/Os
#0760 to #0777 The first address of each rack panel
#1200 to #1376 The first address of special I/O modules.
#0660 to #1377 can be assigned with auto I/O registration or manual I/O registration using a support tool (JW-14PG, etc.) It is impossible to register directly to system memory #0660 to #1377.
Comment memory
JW-50CU, JW-50CUH: The registers for file number 1 can beused for comment memory. (16 kbytes maximum)
JW-70CU/100CU, JW-7OCUH/MOOCUH: The registers for file numbers 1 to 7 and C to E can be used for comment memory. (Note 1)
JW-50CU, JW-50CUH: None
JW-70CU/100CU, JW-70CUH/1 00CUH: Built-in Communication interface standard: RS-485, RS-232C Transfer speed: 9600, 4800, 2400, 1200, 600 bps Data length: 7 bits
Parity bit: odd, even, none
Stop bit: 1 or 2 bits
Connection configuration: 1:1 (RS-232C), 1:N(RS-485) Data format: Subset of computer link format Connector: Dsub-15P
Interrupt program
Input interrupt: 16 levels (LB1360 to LC 1377)
Timer interrupt: 1, 2, 5, 10, or 20ms interval (LB1353 to LB1357)
The input and timer interrupis can be enabled or disabled independently. The labels for disabled interrupts may be used as common labels.
Data for (16 relay points + 6 bytes register) X256 times or 16 relay points x 1024 Sampling] times can b traced at an arbitrary period (50ms units) at every scan to 1 second trace (up to 64 kbytes of data can be traced when a file register is used for trace memory). Break Any program address or data memory address can be set as a breakpoint. fanation (Continuation or break of the opeation can be selected when a break condition Debug is met.) function| Step Executes the program, one circuit at a time. operation N scan Executes operations for the specified number of scans (1 to 9999 scans) operation Forced ON-OFF| Turns an I/O relay ON or OFF regardless of the input signal or operation result of VO (maximum of 32 points each for ON and OFF) relay Note 1: The memory module installed in the control module determines the files that can be used. oe ed as comment memory : File nun __ Address | __ Maximum capacity Z File 1 OQ0000 to 03777 | 16 kbytes ZW-2MA, JW-2MAH File 1 00000 to 17777 | 64 kbytes ZW-3MA, JW-3MAH! File 1 and 2 00000 to 17777 | 198 kbytes for each 448 kbytes Files 4 to 6 and C to E are ZW-4MA Files 1 to7 00000 to 17777 | switched for use (see page Files C to E for each 5-7) 576 k bytes JW-4MAH Files 6 and E are switched for use (see page 5-10)
Page 47
Note 2: The upper or lower state of each item may occur when the fuse is melted down in the system memory #0206 or #0207, or by the setting in the case of option abnormality. Note 3: When the JW-1PU power supply module is used. If the JW-2PU power supply module is used, a transistor output with 24 VDC, 0.5 A rating is used.
Note 4: Valid only for JW-series /O modules.
Continue operation 5>Upper column Halt ouput
Power supply Error code *Note 1 Item Contents |PC operation! Halt _ [indicators module indicator] Special stalus output [RUN | FAULT POWER relay | Special register| System memory | Priority 10734 #0160 to #0167 | level Parity check 21 5 instruction code check 24 5 System memory address 23 2 check a Program ROM check 26 1 Memory |Data ROM error check 07370 20 26 1 Program ROM size 27 1 check 4@) registration 28 4 table check Note 4 VO table parity check 29 4 Stop Open | OFF ON ON - ere ees RAM check 32 1 (R/W) 2 @ | CPU [Parity check 07371 30 33 3 S| Sor | Hardware D s check 35 3 > VO data bus 44 4 ” VO signal 45 4 Input data parity check’ 4 4 Output data 07373 40 42 4 i kK (/O error parity check Installed module 40 4 check Note 4 Output Flash 1 nter- module Operation | Close eter) OFF 07363 49 4 fuse failure |*Note2 __ _ Stop Open | OFF ON | i Fiash Special VO! Operation | Close | (inter | OFF 07375 46 4 error mittent} Power Power supply spol, OFF OFF 07377 10 13 7 error voltage drop J mm sn canine irs = Stop : Open | OFF - Topo Expart- Power sion failure power | or supply ON ON 07376 40 43 7 supply voltage error drop Option . Flash Operation | Close | (inter- OFF module mittent) 53 6 Option | error St O error | *Note2 op pen | OFF | ON 07374 50 Option ON 52 bus error Stop Open | OFF ON “Note 5 | B Baterry aterry voltage Operation | Close | ON ON 07372 20 22 8 error drop Halt output Triac output, 100/200 VAC, 0.5A P Turned ON (closed) when the PC is running. (Note 3) Note 1: All error codes are in BCD. - (Setting) (State)
[>Lower column
Note 5: If the system detects an error in the optional bus, it stops operation by turning ON the normally OFF contact point 07366. In the case of turning ON 07366 with the user's program or that 07366 is ON without clearing the data memory when putting the power in the PC for the first time, error code 52 may be shown.
4-19
Page 48
4-3 Memory module The memory module is used for program creation and storage. The relationship between the control module and memory module is given below.
Installed as a standard module (use of any other memory JW-S0CU, JW-S0CUH | modules ZW-1MA/JW-1MA are not allowed)
JW-70CU/100CU Module not installed {install the memory module as JW-70CUH/100CUH described below)
[1] Memory module selection Select a memory module according to the program capacity and processing speed of the control module.
(1) Processing speed of the control module Control module
Memory module (JW-70CUH/100CUH}
JW-1MAH JW-2MAH JW-3MAH
JW-4MAH
Control module
Memory module (JW-70CGUH/100GUH)
JW-1MAH _ JW-2MAH 3) JW-3MAH JW-4MAH
The relationship between the four installation configurations () to @) shown above and the processing speed of the control module is described below. In installation configuration @, select conventional or high speed operation using the switch on the memory module. (See pages 5-8 to 5-10).Conventional speed refers to the same processing speed that is available on the JW50/70/100.
High speed operation | 0.25 us/instruction | Average us/instruction i *Processing speed durin % operation speed high speed operation is 0.38 us/instruction | approximately 1.5 times @,8,@ Conventional speed that of conventional ded operation speed operation.
¢ For the processing speed of each instruction, refer to the "Description of instructions" in the programming manual.
4-20