Page 1 of Data sheet 3RT1035-1BB40

Spec sheet · Siemens

Data sheet 3RT1035-1BB40

Spec sheet8 pagesPDF 211 KB

Data sheet for the Siemens SIRIUS 3RT1035-1BB40 power contactor: AC-3 40 A, 18.5 kW at 400 V, 24 V DC coil, 3-pole, size S2.

Download the PDF211 KB

Covers · 1 model

The models it covers

Summary

What is in it

Siemens data sheet for the SIRIUS 3RT1035-1BB40 power contactor, a 3-pole size S2 contactor with a 24 V DC coil and screw terminals, marked as a phased-out product with the 3RT2028-1BB40 named as preferred successor. It lists general technical data, ambient conditions, main circuit currents and powers by utilization category, control circuit data, auxiliary circuit ratings, UL/CSA ratings, short-circuit protection, mounting and dimensions, conductor cross-sections, approvals, a dimension drawing and the circuit diagram.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Siemens data sheet, dated 07/17/2018, for the 3RT1035-1BB40 SIRIUS power contactor: 3-pole, size S2, AC-3 40 A, 18.5 kW at 400 V, with a 24 V DC coil and screw terminals. It marks the part as phased out and names its successor. It lists main and auxiliary circuit ratings, coil data, fusing, dimensions, terminals and the circuit diagram.

Device type
SIRIUS power contactor, 3-pole (3 NO main contacts), size S2, screw terminals p. 1, 2
AC-3 rating
40 A at 400 V, 24 A at 690 V; 11 kW at 230 V, 18.5 kW at 400 V, 22 kW at 500 V and 690 V p. 2, 3
Coil
24 V DC; operating range 0.8 to 1.1 of rated value; closing and holding power 13.3 W p. 4
AC-1 rating
60 A at 400 V or up to 690 V (40 °C); 55 A up to 690 V at 60 °C p. 2
AC-4 rating
35 A at 400 V p. 2
Fuse protection
Main circuit fuse gL/gG 125 A (coordination type 1) or 63 A (type 2); auxiliary switch 10 A p. 4, 5
Dimensions
112 mm high, 55 mm wide, 130 mm deep p. 5
Mounting
Screw or snap-on onto 35 mm standard rail (DIN EN 50022); side-by-side mounting allowed p. 5
Main conductors
Solid 2x (0.75 ... 16 mm²); stranded 2x (0.75 ... 25 mm²); AWG 2x (18 ... 2) p. 5
Temperature
Operation -25 ... +60 °C; storage -55 ... +80 °C p. 2
Mechanical life
10 000 000 switching cycles (typical) p. 2
Switching times
Closing delay 60 ... 100 ms; opening delay 20 ... 25 ms; arcing 10 ... 15 ms p. 4
Protection class
IP20 on the front; IP00 at the terminals p. 1
Insulation voltage
690 V rated; surge voltage 6 kV p. 1

What this sheet walks you through

  • DC switching ratings with one, two or three current paths in series p. 2, 3
  • Short-circuit protection fuses p. 4, 5
  • Conductor sizes for main and auxiliary terminals p. 5
  • Dimension drawing p. 7
  • Circuit diagram with coil and main terminals p. 8

Good to know

  • Phased-out product; the preferred successor is the SIRIUS 3RT2028-1BB40. p. 1
  • Safe isolation between coil and main contacts is rated up to 400 V. p. 1
  • 6 mm spacing to grounded parts is required at the side. p. 5

Questions this sheet answers

What replaces the Siemens 3RT1035-1BB40?

It is phased out; the preferred successor is the SIRIUS 3RT2 type 3RT2028-1BB40. p. 1

What is the coil voltage of the 3RT1035-1BB40?

24 V DC, working from 0.8 to 1.1 times that value. p. 4

What motor power can the 3RT1035-1BB40 switch?

In AC-3, 18.5 kW at 400 V, 11 kW at 230 V and 22 kW at 500 V or 690 V. p. 3

How big is the 3RT1035-1BB40 contactor?

112 mm high, 55 mm wide and 130 mm deep. p. 5

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8

The file

Revision and size

Revision07/17/2018
PublisherSiemens
Pages8
PDF211 KB
TextText from the PDF itself.

The first pages · 4 of 8

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 8
Page 2
Page 2of 8
Page 3
Page 3of 8
Page 4
Page 4of 8