Page 1 of Data sheet 3RV2711-0DD10

Spec sheet · Siemens

Data sheet 3RV2711-0DD10

Spec sheet8 pagesPDF 324 KB

Siemens data sheet for the SIRIUS 3RV2711-0DD10 size S00 circuit breaker for system protection to UL 489 (0.32 A).

Download the PDF324 KB

Covers · 1 model

The models it covers

Summary

What is in it

Siemens data sheet for the SIRIUS 3RV2711-0DD10, a 3-pole size S00 circuit breaker for system protection approved to UL 489 and CSA C22.2 No. 5, with a 0.32 A thermal overload release and a 4.2 A magnetic short-circuit release. It lists general technical data, ambient conditions, main circuit ratings, short-circuit breaking capacities, mounting and dimensions, required spacing, terminal and conductor data, safety related data and approvals, with a dimension drawing and circuit diagram.

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

An eight-page Siemens data sheet, dated 10/01/2018, for the SIRIUS 3RV2711-0DD10 circuit breaker in size S00 for system protection, with a 0.32 A overload release and screw terminals. It gives the voltage, current and breaking capacity ratings, ambient limits, mounting clearances, dimensions, conductor sizes and tightening torque, with drawings and a circuit symbol. A reader can use it to check that the breaker suits a small motor or control circuit.

Type
SIRIUS 3RV2 circuit breaker, size S00, for system protection, 3 poles, standard switching capacity p. 1, 2
Releases
Thermal A-release 0.32 A; magnetic N-release (instantaneous short-circuit) 4.2 A p. 1, 3
Approval
The spec sheet states approval as a circuit breaker to UL 489 and CSA C22.2 No.5-02 p. 1
Rated voltage
690 V, 50 to 60 Hz p. 2
AC-3 power
40 W at 230 V, 90 W at 400 V, 120 W at 500 V and 690 V p. 2
Breaking capacity
Icu and Ics 100 kA at 240, 400, 500 and 690 V AC; 65 000 A at 480Y/277 V AC to UL 489 p. 3
DC breaking (Icn)
10 kA: 1 path at 150 V, 2 paths in series at 300 V, 3 paths in series at 450 V p. 3
Mounting
Screw or snap-on onto 35 mm standard rail (DIN EN 60715), any position p. 3
Dimensions
144 mm high, 45 mm wide, 97 mm deep p. 3
Main terminals
Screw-type, top and bottom; 1 to 10 mm² solid or stranded (max. 2x 10 mm²); AWG 2x (14 to 10) p. 4
Tightening torque
2.5 to 3 N·m, M4 screws, Pozidriv 2 p. 4
Ambient conditions
-20 to +60 °C operating; -50 to +80 °C storage; 10 to 95 % relative humidity p. 2
Service life
100 000 switching cycles typical, mechanical (main and auxiliary contacts) and electrical p. 2
Power loss
5 W typical; an auxiliary switch can be added p. 1

What this sheet walks you through

  • Main circuit ratings and AC-3 motor power p. 2
  • Short-circuit breaking capacity on AC and DC p. 3
  • Clearances for side-by-side mounting and to grounded and live parts p. 3, 4
  • Conductor sizes and terminal torque p. 4
  • Safety related data to SN 31920 and IEC 61508 p. 4, 5
  • Dimension drawing and circuit symbol p. 6, 8

Good to know

  • Leave 50 mm above and below the breaker; 30 mm at the side to grounded or live parts. p. 4
  • Maximum installation altitude is 2 000 m. p. 2
  • The terminals are IP00; the front is IP20. p. 1, 2
  • At AC-3 the maximum operating frequency is 15 per hour. p. 2

Questions this sheet answers

What is the trip current of the 3RV2711-0DD10?

The overload (A) release is 0.32 A and the instantaneous short-circuit (N) release is 4.2 A. p. 1

Is the 3RV2711-0DD10 a UL 489 breaker?

The data sheet states approval as a circuit breaker to UL 489 and CSA C22.2 No.5-02. p. 1

Can the 3RV2711-0DD10 be used on DC?

It lists a 10 kA DC breaking capacity: one path at 150 V, two in series at 300 V, three in series at 450 V. p. 3

What torque do the 3RV2711-0DD10 terminals take?

2.5 to 3 N·m on the M4 main terminal screws, with a Pozidriv 2 screwdriver. p. 4

The whole text · 1 part

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8

The file

Revision and size

Revision10/01/2018
PublisherSiemens
Pages8
PDF324 KB
TextText from the PDF itself; page 7 is a scan, read by OCR, which may hold reading errors.

The first pages · 4 of 8

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 8
Page 2
Page 2of 8
Page 3
Page 3of 8
Page 4
Page 4of 8