SIMATIC S5 S5-100U Programmable Controller System Manual, CPU 100/102/103, pages 11 to 20

Pages 11 to 20 of 69

The original document is the PDF (878 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Siemens 6ES5-095-8MC01, Siemens 6ES5-431-8MA11, Siemens 6ES5-451-8MA11 and Siemens 6ES5-452-8MR11

Page 11

S5-100U

Contents

Page 13

Connecting the S5-100U to SINEC L1, for CPU 102 and Higher 13.1

.........

13 - 1

Connecting the Programmable Controllers to the L1 Bus Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13 - 1

Setting Parameters in the Programmable Controller for Exchanging Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.2.1 How to Program in a Function Block, for CPU 102 and Higher ....... 13.2.2 Setting Parameters in DB1, for CPU 103 and Higher . . . . . . . . . . . . . .

13 - 1 13 - 2 13 - 5

13.3 13.3.1 13.3.2 13.3.3

13 - 7 13 - 8 13 - 9 13 - 11

13.2

14

15

Coordinating Data Exchange in the Control Program . . . . . . . . . . . . . . . Sending Data ......................................... Receiving Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming the Messages in a Function Block . . . . . . . . . . . . . . . . .

Module Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 - 1

14.1

General Technical Specifications

............................

14 - 3

14.2

Power Supply Modules

...................................

14 - 4

14.3

Central Processing Units

.................................

14 - 7

14.4

Bus Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 - 10

14.5

Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 - 14

14.6 14.6.1 14.6.2 14.6.3

Digital Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Input Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Input/Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 - 16 14 - 16 14 - 26 14 - 36

14.7 Analog Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.7.1 Analog Input Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.7.2 Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14 - 38 14 - 38 14 - 56

Function Modules

15 - 1

...........................................

15.1

Comparator Module 2×1 to 20 mA/0.5 to 10 V

15.2

Timer Module 2×0.3 to 300 s

15.3 15.4

..................

15 - 1

..............................

15 - 4

Simulator Module

.......................................

15 - 7

Diagnostic Module

......................................

15 - 9

EWA 4NEB 812 6120-02b xi

Page 12

Contents

S5-100U

Page

15.5

Counter Module 2×0 to 500 Hz

.............................

15.6 15.6.1 15.6.2 15.6.3 15.6.4 15.6.5 xii

15 - 12

Counter Module 25/500 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Description of the Counter Mode . . . . . . . . . . . . . . . . . . . . Functional Description of the Position Decoder . . . . . . . . . . . . . . . . . . Entering New Setpoints for the Counter and Position Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.6.6 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15 - 17 15 - 20 15 - 25 15 - 27 15 - 29

15.7

Closed-Loop Control Module IP 262 . . . . . . . . . . . . . . . . . . . . . . . . . .

15 - 41

15.8

IP 263 Positioning Module

15 - 45

15.9

IP 264 Electronic Cam Controller Module

15.10

IP 265 High Speed Sub Control

.................................

15 - 38 15 - 39

......................

15 - 49

.............................

15 - 52

15.11

Positioning Module IP 266 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15 - 55

15.12

Stepper Motor Control Module IP 267

........................

15 - 59

15.13 Communications Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.13.1 Printer Communications Module CP 521 . . . . . . . . . . . . . . . . . . . . . . 15.13.2 Communications Module CP 521 BASIC . . . . . . . . . . . . . . . . . . . . . .

15 - 62 15 - 62 15 - 65

EWA 4NEB 812 6120-02b

Page 13

S5-100U

Contents

Appendices A

Operations List, Machine Code and List of Abbreviations

..............

A - 1

A.1 A.1.1 A.1.2 A.1.3 A.1.4

Operations List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplementary Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Operations, for CPU 102 and Higher . . . . . . . . . . . . . . . . . . . . . Evaluation of CC 1 and CC 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

A - 1 A - 1 A - 8 A - 13 A - 14

A.2

Machine Code Listing

.....................................

A - 15

A.3

List of Abbreviations

......................................

A - 18

..........................................

B - 1

B

Dimension Drawings

C

Active and Passive Faults in Automation Equipment

D

Information for Ordering Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D - 1

E

Reference Materials

...........................................

E - 1

F

Siemens Addresses Worldwide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

F - 1

..................

C - 1

Index

EWA 4NEB 812 6120-02b xiii

Page 14

EWA 4NEB 812 6120-02b

Page 15

S5-100U

How to Use This System Manual

How to Use This System Manual The S5-100U is a programmable controller for lower and intermediate performance ranges. It meets all the requirements for a modern programmable controller. To use this controller optimally, you need detailed information. In this system manual we have attempted to present this information as completely and as well organized as possible. Certain information is repeated in various chapters so that you do not have to leaf through the manual to find what you need. This How to Use This System Manual section gives you information that will make it easier for you to find what you need. This section explains how the manual is organized.

Contents of This System Manual •

Hardware Description (Chapters 1, 2, and 3) These chapters describe the controllers: how they fit into the SIMATIC® S5 family of programmable controllers, how they function, and how you install them.

•

Start-Up Information (Chapters 4, 5, and 6) These chapters summarize the information you need to start up your programmable controller. These chapters describe how the hardware and software influence each other.

•

The Programming Language of the Programmable Controllers (Chapters 7, 8, and 9) These chapters describe the structure, operations, and structuring aids of the STEP® 5 programming language.

•

Functions of the Programmable Controllers (Chapters 10, 11, 12, 13) Each of these chapters contains a complete description of a particular function, from wiring to programming. Subjects include analog value processing, counter and interrupt inputs, integral clock, and the programmable controller as a SINEC® L1 slave.

•

Module Spectrum (Chapters 14 and 15) These chapters contain information about all the currently available S5-100U modules that you can use to expand your controller. Chapter 15, Function Modules, includes the modules that require an extensive description (i. e., more than just technical specifications).

•

Overviews (Appendices) In these chapters you will find not only a complete list of operations but also dimension drawings, a description of errors that may occur during operation of the programmable controller, maintenance and repair procedures, a list of accessories, and reference literature about programmable controllers.

You will find correction pages at the end of the system manual. Use them to indicate any corrections, additions, or suggestions for improvement you might have. Send these suggestions to us. They will help us to improve the next edition of this system manual.

EWA 4NEB 812 6120-02b xv

Page 16

How to Use This System Manual

S5-100U

Conventions This system manual is organized in menu form to make it easier for you to find information. This means the following: •

Each chapter is marked with printed tabs.

•

At the front of the system manual is an overview page that lists the title of each chapter. Following this page, you will find a table of contents.

•

At the beginning of each chapter is a table of contents for that chapter. Each chapter has three level headings that are numbered. The fourth level heading is not numbered but appears in boldface type.

•

Pages, figures, and tables are numbered separately for each chapter. On the back of the table of contents for each chapter you will find a list of the figures and tables that appear in that chapter.

This system manual employs the following specific structuring devices: •

Specific terms have characteristic abbreviations (e. g., programmer is PG). Appendix A contains a list of abbreviations.

•

Footnotes are marked with a raised number (e. g., “1”) or a raised asterisk (“ * ”). You will find the corresponding explanations in the lower margin of the page or under a figure or table if the footnote appears in one of these.

•

Lists are designated with bullets (• as in this particular listing) or with hyphens (-).

•

Cross references are indicated as follows: (see section 7.3.2). There are no references to specific page numbers.

•

Dimensions in drawings are indicated in millimeters and inches.

•

Value ranges are indicated as follows: 17 to 21 or 17-21.

•

Especially important information appears in framed boxes such as the following:

Warning

You will find definitions for the terms “Warning,” “Danger,” “Caution,” and “Note” in the SafetyRelated Guidelines for the User at the end of the introduction.

xvi

EWA 4NEB 812 6120-02b

Page 17

S5-100U

How to Use This System Manual

Changes Made to the Second Edition of the S5-100U System Manual (Order Number: 6ES5 998-0UB22) S5-100U System Manual (Order Number 6ES5 998-0UB23) has been completely revised: •

The format was adapted to the other system manuals in the SIMATIC S5 family.

•

The contents were updated and reorganized.

Some of the functions of CPU 103 have been expanded: •

The default settings (default parameters) for DB1 have been integrated into CPU 103 version 8MA03. This feature makes it easier for you to use the internal CPU functions. The following chapters were included or completely revised in the system manual: - Chapter 9 “Integrated Blocks and Their Functions” - Chapter 12 “Integral Real-Time Clock, for CPU 103 Version 8MA02 and Higher” - Chapter 13 “Connecting the S5-100U to SINEC L1, for CPU 102 and Higher”

•

The execution times of some operations have been reduced considerably, compared to the “old” CPU 103. For the new execution times refer to the list of operations in Appendix A.

The S5-100U system has been expanded to include an additional module: •

The “Communications Module CP 521 BASIC” is described in section 15.10.2.

Changes Made to the Third Edition of the S5-100U System Manual (Order Number: 6ES5 998-0UB23) The contents were updated.

Training Siemens offers a wide range of training courses for SIMATIC S5 users. Contact your Siemens representative for more information.

EWA 4NEB 812 6120-02b xvii

Page 18

How to Use This System Manual

S5-100U

Safety-Related Guidelines for the User This document provides the information required for the intended use of the particular product. The documentation is written for technically qualified personnel. Qualified personnel as referred to in the safety guidelines in this document as well as on the product itself are defined as follows. • System planning and design engineers who are familiar with the safety concepts of automation equipment. • Operating personnel who have been trained to work with automation equipment and are conversant with the contents of the document in as far as it is connected with the actual operation of the plant. • Commissioning and service personnel who are trained to repair such automation equipment and who are authorized to energize, de-energize, clear, ground, and tag circuits, equipment, and systems in accordance with established safety practice. Danger Notices The notices and guidelines that follow are intended to ensure personal safety, as well as protect the products and connected equipment against damage. The safety notices and warnings for protection against loss of life (the users or service personnel) or for protection against damage to property are highlighted in this document by the terms and pictograms defined here. The terms used in this document and marked on the equipment itself have the following significance.

Danger

Warning indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.

Caution indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken.

Note indicates that minor personal injury or property damage can result if proper precautions are not taken.

contains important information about the product, its operation or a part of the document to which special attention is drawn.

Proper Usage

Warning •

• xviii

The equipment/system or the system components may only be used for the applications described in the catalog or the technical description, and only in combination with the equipment, components, and devices of other manufacturers as far as this is recommended or permitted by Siemens. The product will function correctly and safely only if it is transported, stored, set up, and installed as intended, and operated and maintained with care.

EWA 4NEB 812 6120-02b

Page 19

1

The SIMATIC S5 System Family

EWA 4NEB 812 6120-02b

Page 20

Figures 1-1

Members of the SIMATIC S5 System Family

......................

1 - 1