Manual · Siemens
SIMATIC S5 S5-100U Programmable Controller System Manual, CPU 100/102/103
Manual69 pagesPDF 878 KB
Opening chapters of the Siemens SIMATIC S5-100U system manual (CPU 100/102/103): system family, technical description and installation.
What this file really is
The old site listed this file as “S5 Manual” for the Siemens 6ES5-095-8MC01, 6ES5-431-8MA11 and 2 more models. Linked as the manual for the 6ES5-095-8MC01 and several S5-100U modules, it is only the first three chapters of the S5-100U system manual and does not name those catalog numbers.
Filed with · 4 models
Also filed with these models on the old site
Summary
What is in it
The opening part of the Siemens system manual for the SIMATIC S5-100U programmable controller with CPU 100, 102 and 103. This file holds the full contents list and the first three chapters: where the S5-100U fits in the SIMATIC S5 family, its design and principle of operation including the external I/O bus, and installation guidelines covering mounting tiers, wiring the power supply and digital modules, electrical configuration, shielding and protection against interference. The later chapters listed in the contents are not in this file.
Its parts
- The SIMATIC S5 System Family
- Technical Description
- Installation Guidelines
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Part of the Siemens SIMATIC S5 S5-100U Programmable Controller System Manual for CPU 100, CPU 102 and CPU 103 (EWA 4NEB 812 6120-02b, Edition 04): the contents, the introduction, the technical description and the installation guidelines. None of the 6ES5 part numbers the site files it under is named in it. It explains how an S5-100U is built and expanded, how its I/O bus works, and how to mount and wire it.
- Type
- SIMATIC S5-100U modular programmable controller; up to 448 digital inputs and outputs, depending on the CPU p. 22
- CPUs covered
- CPU 100, CPU 102, CPU 103 p. 1
- Power
- 24 V DC to the CPU, or the PS 930 power supply module when 24 V DC is not available p. 25, 37
- Programming
- STEP 5 with three methods of representation (four from CPU 103); U series programmers or memory submodules p. 22
- Serial port
- For a programmer, operator panel or monitor; also connects the S5-100U as a SINEC L1 slave p. 25, 28
- Memory backup
- Backup battery keeps RAM contents through a power failure; programs stored on EPROM or EEPROM memory submodules p. 25, 28
- Expansion limits
- CPU 100: 256 data bits (128 analog); CPU 102: 480 (256 analog); CPU 103: 704 (512 analog) p. 32
- Data cycle time
- 25 µs x number of data bits in the shift register p. 32
- I/O modules
- Digital (4, 8 and 16/16 channel), analog, timer, 500 Hz counter, 25/500 kHz high-speed counter, comparator, simulator, diagnostic, CP and IP modules p. 26
- Mounting
- Standard mounting rail to DIN EN 50022-35x15; each bus unit takes two I/O modules p. 26, 37
- Vertical mounting
- Allowed, with a clamp at the lower end; maximum ambient 40 °C (104 °F) p. 44
- Load voltage terminals
- 24 V DC: terminal 1 L+, terminal 2 M; 115/230 V AC: L1 and N p. 49
- Screw terminals
- SIGUT screw terminals take two cables each; 2 x 0.5 to 1.5 mm2 or 2 x 0.5 to 2.5 mm2 by conductor type p. 45
- Example modules
- 6ES5 430-8MB11 input 4 x 24-60 V DC; 6ES5 440-8MA22 output 4 x 24 V DC/2 A; 6ES5 421-8MA12 input 8 x 24 V DC; 6ES5 441-8MA11 output 8 x 24 V DC/0.5 A p. 50, 51, 52, 53
What this manual walks you through
- Parts of an S5-100U and what each module does p. 25, 26
- How the CPU, memory and I/O bus work p. 27, 28, 29, 30, 31
- Working out the maximum expansion for each CPU p. 32, 33
- Installing, removing and changing components safely p. 37
- Mounting the controller vertically p. 44
- Wiring screw-type terminals p. 45
- Connecting four-channel and eight-channel digital modules p. 49, 50, 51, 52, 53
Good to know
- Exceeding the maximum expansion puts the S5-100U into STOP mode. p. 32
- Digital outputs hold energy in a capacitor for about 100 ms after L+ is switched off, enough to trigger small loads. p. 49
- Vertical mounting lowers the maximum ambient temperature to 40 °C (104 °F). p. 44
- Change I/O modules only in STOP mode with the load voltage off. p. 37
Questions this manual answers
How many I/O points can an S5-100U have?
Up to 448 digital inputs and outputs, depending on the CPU. p. 22
Does the S5-100U need a separate power supply module?
Only when 24 V DC is not available for the CPU; then the PS 930 power supply module is used. p. 25
How many analog modules can a CPU 100 handle?
The CPU 100 allows 256 data bits, at most 128 of them from analog modules; for example six 8-channel digital and two 4-channel analog modules. p. 32, 33
Can the S5-100U be mounted vertically?
Yes, with a clamp on the lower end of the tier, but the maximum ambient temperature is then 40 °C (104 °F). p. 44
Which terminals take the 24 V DC load voltage on an S5-100U digital module?
L+ on terminal 1 and M on terminal 2. p. 49
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file





