Simatic S5 to RSLogix 5000 Application Conversion Guide

Manual140 pagesPDF 3.5 MB

Rockwell Automation guide to converting Siemens SIMATIC S5 controllers, I/O and STEP 5 programs to Logix and RSLogix 5000.

What this file really is

The old site listed this file as “Technical manual” for the Siemens 6ES5-095-8MC01, 6ES5-431-8MA11 and 2 more models. This is a Rockwell Automation guide to converting Siemens S5 systems to Logix, not a Siemens technical manual for the 6ES5-095-8MC01.

Download the PDF3.5 MB

Names · 3 models

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

An application conversion guide from Rockwell Automation for engineers migrating a Siemens SIMATIC S5 system to a Logix programmable automation controller. It matches S5 controllers and digital, relay and analog I/O modules (such as the 6ES5 431-8MA11, 451-8MA11 and 452-8MR11) to Logix replacements, explains how to convert STEP 5 program structure and instructions to RSLogix 5000, and covers system functions, communication and networking, drive and loop control, and third-party communication modules.

Its parts

  1. Preface
  2. Controllers and I/O Modules
  3. Software Conversions - Program Structure
  4. Software Conversions Instructions
  5. Additional RSLogix 5000 Features
  6. Conversion of System Functions
  7. Communication and Networking
  8. Drive and Loop Control
  9. Logix Replacements for S5 Components

From the manual

Key facts from this manual

Each line names its page in the PDF.

This is the Simatic S5 to RSLogix 5000 Application Conversion Guide from Rockwell Automation (publication LOGIX-AP010B-EN-P), not a Siemens manual for one part, and it does not name the 6ES5-095-8MC01. It covers replacing Siemens S5 controllers and I/O modules, among them the 6ES5 431-8MA11, 6ES5 451-8MA11 and 6ES5 452-8MR11, with Allen-Bradley Logix hardware, and converting STEP 5 programs to RSLogix 5000. It lists S5 CPU memory sizes and module ratings beside suggested Logix replacements.

Read for this summary: pages 1 to 2, 7 to 9, 13 to 29 and 119 to 124 of 140.

6ES5 431-8MA11
6ES5 431-8MA11: digital input module, 8 inputs at 24V DC; suggested Logix replacement 1756-IB16 (16 inputs, 12/24V DC) p. 17, 121
6ES5 451-8MA11
6ES5 451-8MA11: digital DC output module, 8 outputs at 24V DC; suggested Logix replacement 1756-OB8 (8 outputs, 12/24V DC) p. 21, 122
6ES5 452-8MR11
6ES5 452-8MR11: relay output module rated 30V DC / 230V AC; suggested Logix replacement 1756-OX8I (8 relay outputs, 10…265V AC, 5…150V DC) p. 22, 123
Document
Rockwell Automation application conversion guide, publication LOGIX-AP010B-EN-P, May 2010 p. 7
S5 phase-out
Siemens announced in 2002 a phase-out of the S5 starting October 1, 2003, with spare parts until October 1, 2013 (S5-115: September 30, 2014; S5-135/155: September 30, 2015) p. 13
S5 CPU memory
CPU 90U 4 KB, CPU 95U 16 KB, up to CPU 948-2 at 1664 KB p. 14
Small S5 replacement
For S5-90U or S5-95U: CompactLogix 1769-L31 (512 KB, 4 tasks), 1769-L32 (700 KB, 6 tasks) or 1769-L35 (1.5 MB, 8 tasks) p. 119
Logix memory sizing
About 4000 bytes per task, 400 per digital I/O point, 2600 per analog point, 7400 per DeviceNet module, 8000 per motion axis; S5 code about 2 bytes per statement p. 16, 17
S5 range cards
498-1AA21 ±1V, 498-1AA31 ±10V, 498-1AA41 ±20 mA, 498-1AA51 4…20 mA, 498-1AA61 ±5V, 498-1AA71 4…20 mA, used with some S5-135U and S5-155U analog input modules p. 23
Analog addressing
S5 analog modules are addressed by switches on the side of the module; Logix analog modules are addressed automatically p. 26
FLEX I/O on S5
An S5 controller as Profibus master can run 1794 FLEX I/O through the 1794-APB Profibus adapter p. 29

What this manual walks you through

  • Choosing a Logix controller with enough memory for converted S5 code p. 14, 15, 16, 119, 120
  • Matching S5 digital input modules to ControlLogix input modules p. 17, 18, 19, 20, 121
  • Matching S5 digital DC, AC and relay output modules to ControlLogix modules p. 21, 22, 122, 123
  • Choosing and configuring Logix analog modules in place of S5 analog modules p. 23, 24, 25, 26, 124
  • Keeping S5 I/O during a phased migration over Profibus DP p. 27, 28, 29
  • Planning a conversion rather than a line-by-line translation of STEP 5 code p. 7

Good to know

  • A converted program typically needs more memory in a Logix controller than it did in the S5, because tags and comments are stored in the CPU. p. 15
  • No ControlLogix digital input module works with inputs of 30 to 60V AC. p. 20
  • The controller tables are suggestions only; the right replacement depends on the application. p. 119
  • A program uploaded from an S5 without the original files has no symbols. p. 15

Questions this manual answers

What can replace a Siemens 6ES5 431-8MA11 input module?

The guide suggests the ControlLogix 1756-IB16 (16 inputs, 12/24V DC) for this 8-input 24V DC module. p. 121

What replaces a 6ES5 451-8MA11 output module?

The guide pairs it with the ControlLogix 1756-OB8, 8 outputs at 12/24V DC. p. 122

What replaces a 6ES5 452-8MR11 relay module?

The guide suggests the 1756-OX8I relay module, rated 10…265V AC and 5…150V DC. p. 123

How much memory does an S5 CPU 95 have and what replaces it?

16 KB; the guide's table pairs it with a 1769-L3x CompactLogix controller, listed at 2 MB. p. 120

Until when were S5 spare parts available?

The guide gives October 1, 2013 in general, September 30, 2014 for the S5-115 and September 30, 2015 for the S5-135/155. p. 13

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Cover1
  2. Preface7
    1. Purpose7
    2. Conversion versus Translation7
    3. Terminology8
    4. Additional Resources8
    5. PLC Logic Conversion Services Provided by Rockwell Automation9
  3. Chapter 1: Controllers and I/O Modules13
    1. Introduction13
    2. S5 Controllers14
    3. Logix Controllers15
    4. Digital Input Modules17
    5. Digital Output Modules21
    6. Analog Input/Output Modules23
    7. Logix Controller with S5 I/O27
    8. S5 Controller with Logix I/O29
  4. Chapter 2: Software Conversions - Program Structure31
    1. Introduction31
    2. Organization Blocks/Logix Tasks31
    3. RSLogix 5000 Programs35
    4. Blocks/Routine36
    5. Function Blocks/Add-On Instructions38
    6. Watchdog Timer39
    7. I/O Addressing39
    8. Logix Aliasing41
    9. Internal Memory Addressing43
    10. Programming Languages48
    11. Conversion of STEP 5 Code to RSLogix 5000 Software50
  5. Chapter 3: Software Conversions Instructions53
    1. Introduction53
    2. Jump Operations73
    3. Arithmetic Operations77
    4. Block Call Operations86
    5. Shift Operations89
    6. Conversion Operations91
  6. Chapter 4: Additional RSLogix 5000 Features97
    1. Introduction97
    2. Task Monitor97
    3. Asynchronous I/O Updating98
32 more lines, from page 98 on
  1. DINT Data Type98
    1. String Data Type98
    2. Coordinated System Time (CST)99
    3. Timestamped Inputs100
    4. Scheduled Outputs100
  2. Chapter 5: Conversion of System Functions101
    1. Introduction101
    2. Logix System Values101
    3. Read/Write System Time102
    4. Save/Load Scratchpad Area104
  3. Chapter 6: Communication and Networking105
    1. S5 Serial Communication105
    2. Logix Serial Communication106
    3. S5 Distributed Control Systems107
    4. S5 Network Communication108
    5. NetLinx Networks109
  4. Chapter 7: Drive and Loop Control115
    1. Encoder/Positioning Modules115
    2. Logix Servo Drive Controllers115
    3. Replacing S5 Positioning Module with Logix116
    4. Controller with Motion116
    5. S5 Analog Control Modules117
    6. Logix Analog Control118
  5. Chapter 8: Logix Replacements for S5 Components119
    1. Introduction119
    2. Controller Memory Use119
  6. Appendix A: Other Communication Modules127
    1. Introduction127
    2. In-rack Modules127
    3. Standalone Modules133
    4. In-rack Interface Cards for S5 rack136
  7. Back Cover/Rockwell Support140

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Preface7-12
  3. Chapter 1: Controllers and I/O Modules, pages 13 to 2113-21
  4. Chapter 1: Controllers and I/O Modules, pages 22 to 3022-30
  5. Chapter 2: Software Conversions - Program Structure, pages 31 to 3831-38
  6. Chapter 2: Software Conversions - Program Structure, pages 39 to 4639-46
  7. Chapter 2: Software Conversions - Program Structure, pages 47 to 5247-52
  8. Chapter 3: Software Conversions Instructions, pages 53 to 6153-61
  9. Chapter 3: Software Conversions Instructions, pages 62 to 7062-70
  10. Chapter 3: Software Conversions Instructions, pages 71 to 7971-79
  11. Chapter 3: Software Conversions Instructions, pages 80 to 8880-88
  12. Chapter 3: Software Conversions Instructions, pages 89 to 9689-96
  13. Chapter 4: Additional RSLogix 5000 Features97-100
  14. Chapter 5: Conversion of System Functions101-104
  15. Chapter 6: Communication and Networking105-114
  16. Chapter 7: Drive and Loop Control115-118
  17. Chapter 8: Logix Replacements for S5 Components119-126
  18. Pages 127 to 140127-140

The file

Revision and size

Part no.LOGIX-AP010B-EN-P
RevisionMay 2010
PublisherRockwell Automation
Pages140
PDF3.5 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.
LOGIX-AP010B-EN-P