Page 7

Preface

Purpose

This user manual provides guidance for users and engineers who have used control systems based on one of these two platforms: • •

Siemens S5 Controller Rockwell Automation Logix Programmable Automation Controller (PAC)

And in addition: • • have a desire or must take advantage of the PAC features, or are in the early stages of migrating a S5 to Logix. have STEP 5 program code that they wish to convert to effective and efficient RSLogix 5000 code.

Use this manual to help you adopt good practices and to avoid common mistakes when converting the project to Logix.

Conversion versus Translation

The theme of conversion versus translation is one that is repeated in this application conversion guide. Simple translation is focusing only on the line of code and finding an equivalent in the Logix languages. To convert an application optimally, you have to do more than just translate. For instance, you may benefit from choosing another programming language, utilizing other programming techniques, and designing another scheduling scheme to solve the same task. So, conversion is performed in a context of a higher level design and knowledge of the strengths of the Logix system. If you have application code to convert, you must understand your STEP 5 program before you start conversion – by having been involved yourself in its development, or by reading documentation of the program and of the process that it controls. If the program or the process is unfamiliar or poorly documented, proper conversion will be difficult – it will be mere translation and is less likely to succeed. For example, in Logix, there is a global name space, whereas in the Siemens environment there are data blocks that can be loaded/unloaded by application code. Appreciation of this helps you design a strategy for conversion. In cases where process and program documentation is poor, it may be more cost effective to draw up a new specification and begin your Logix program with minimal time spent on translating the old program.

Publication LOGIX-AP010B-EN-P - May 2010

7

Page 8

Preface

Terminology

STEP 5 is the programming software environment for Siemens SIMATIC S5 controllers. RSLogix 5000 software is used with Rockwell Automation Logix programmable automation controllers. We refer to Logix as a programmable automation controller because it does so much more than a traditional general-purpose PLC. It provides an excellent control platform for multi-discipline control, a common namespace, Coordinated System Time for truly scalable multi-CPU architectures, user-defined data types, and full NetLinx connectivity. The term “Logix” refers to any of the ControlLogix, CompactLogix, GuardLogix, FlexLogix, DriveLogix, or SoftLogix controllers, or the RSLogix 5000 programming environment where it is clear from the context to which it is being referred.

Additional Resources

8

Every section of this application conversion guide references other Rockwell Automation user manuals, selection guides, and documents in which more information can be found. Publication Number

Publication Title

1756-SG001

ControlLogix Controllers Selection Guide

1769-SG001

1769 CompactLogix Controllers Selection Guide

1768-UM001

1768 CompactLogix Controllers User Manual

1769-SG002

Compact I/O Selection Guide

1756-RM094

Logix5000 Controllers Design Considerations Programming Manual

1756-PM001

Logix5000 Controllers Common Procedures Programming Manual

1756-RM003

Logix5000 Controllers General Instructions Reference Manual

1734-SG001

POINT I/O Selection Guide

1738-SG001

ArmorPoint I/O Selection Guide

1792-SG001

ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide

1794-SG002

FLEX I/O and FLEX Ex Selection Guide

NETS-SG001

NetLinx Selection Guide

VIEW-SG001

Visualization Platforms Selection Guide

IA-RM001

Integrated Architecture: Foundations of Modular Programming

6873-SG004

Encompass Program Product Directory

1756-PM010

Logix5000 Controllers Add-On Instructions Programming Manual

1756-RM087

Logix5000 Controllers Execution Time and Memory Use Reference Manual

IASIMP-RM001

IA Recommended Literature Reference Manual

Publication LOGIX-AP010B-EN-P - May 2010

Page 9

Preface

PLC Logic Conversion Services Provided by Rockwell Automation

Rockwell Automation provides additional services for PLC logic conversion. • • • • • • •

Service Features One-stop PLC Program Conversion Services Service Benefits Services Offered Basic Conversion Package Conversion Plus Initial Clean-up Package Additional Program Conversions Available

Service Features Program Conversion Services will convert your legacy Allen-Bradley brand PLC or third-party programmable controller program to run on a Logix programmable automation control system, or the SLC 500/MicroLogix or PLC-5 programmable controllers. Legacy products are often expensive to support and are difficult to repair, which can increase downtime and decrease production. For this reason, Rockwell Automation Customer Support now offers Program Conversion Services. These services are designed to reduce the cost and the time it takes to migrate from a legacy PLC to one of our current PAC or PLC-control platform families.

One-stop PLC Program Conversion Services Migration to a current Allen-Bradley control platform from a legacy product will improve your manufacturing process, system reliability and flexibility, give you more access to application processing power, and reduce equipment repair costs and spares inventory. With Program Conversion Services from Rockwell Automation Customer Support, your programmable controller program will be expertly and quickly converted to the new controller family. Rockwell Automation customer support engineers can help in the migration of legacy Allen-Bradley equipment or convert your PLC systems to Rockwell Automation products while minimizing downtime and maximizing operational success.

Publication LOGIX-AP010B-EN-P - May 2010

9

Page 10

Preface

Service Benefits Specialists for each of the product platforms will be involved during the program conversion process. There are no hard to find anomalies in the logic caused by typing errors. In most cases, the entire data table is reproduced and no data is lost, and the original documentation is preserved with no re-typing of comments and symbols. Original Allen-Bradley brand programs can be in 6200, APS, or AI series format. New programs will be in the RSLogix format.

Services Offered Two program-conversion packages are available and project-specific custom packages are done on a case-by-case basis.

Basic Conversion Package •

•

•

The original programmable controller program will be converted to the ControlLogix, CompactLogix, PLC-5, or SLC 500/MicroLogix format. The package provides an error listing generated during the conversion that includes instructions that are not directly convertible and any addresses that may not have been converted, which could include pointers and indirect addressing. The program and error listing would be returned to the customer for manual debugging and correction.

Conversion Plus Initial Clean-up Package • • •

10

The original programmable controller program will be converted to the ControlLogix, PLC-5, or SLC 500/MicroLogix format. We will correct and convert any instruction and/or addressing errors to the new processor family. The completed program will then be returned to the customer for final startup and debugging.

Publication LOGIX-AP010B-EN-P - May 2010

Page 11

Preface

Additional Options Additional options include the following: • •

•

Application-level telephone support during the start-up and debugging phase of the project. Consultation on system re-engineering, operator interface, architecture and communication strategies, to take full advantage of the new platform’s control capabilities that are not part of a code translation effort, training, and onsite startup is available as an added value from you local Global Sales and Solutions (GSS) office. Complete turn-key migration or upgrades are available from your local GSS/Engineered Systems Office.

Additional Program Conversions Available • • • • • • •

PLC-2 format to ControlLogix, CompactLogix, PLC-5, SLC500/MicroLogix format PLC-3 format to ControlLogix, CompactLogix, or PLC-5 format PLC-5/250 format to ControlLogix or CompactLogix format Modicon – Quantum, 984, 584, 380, 381, 480, 485, 780, 785 to ControlLogix or CompactLogix format Siemens – S-5, S-7 to ControlLogix or CompactLogix format TI - 520, 520C, 525, 530, 530C, 535, 560, 560/565, 565, 560/560T, 560T, 545, 555, 575 to ControlLogix or CompactLogix format GE Series 6 to ControlLogix or CompactLogix format

Program conversions of other third-party programmable controllers to Allen-Bradley controller programs are also available. Contact technical support for details. To schedule a conversion project, or learn more about the Program Conversion Services, contact your local Rockwell Automation sales office or authorized distributor: email us at raprogramconversion@ra.rockwell.com, or visit http://www.rockwellautomation.com/support and view KnowledgeBase Document G19154. IMPORTANT

Publication LOGIX-AP010B-EN-P - May 2010

Use consultation services for re-engineering, typically to expand the system functionality and not to change out hardware due to obsolete or related reasons. SLC to Logix format and PLC-5 to Logix format conversions and PCE comment generation are built into RSLogix 5000 software.