Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 4 of 18

Simatic S5 to RSLogix 5000 Application Conversion Guide: Chapter 1: Controllers and I/O Modules, pages 22 to 30

Pages 22 to 30 of 140, from Simatic S5 to RSLogix 5000 Application Conversion Guide

The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Siemens 6ES5-431-8MA11, Siemens 6ES5-451-8MA11 and Siemens 6ES5-452-8MR11

Page 22

Chapter 1

Controllers and I/O Modules

The Siemens S5 6ES5 457-4UA12 Digital DC Output Module has an operating range of 24…60V DC. The actual values of input voltage presented by the input signals should be reviewed and if within the range 30…60V DC, then this module can be replaced by the ControlLogix 1756-OC8 module. Siemens S5 Digital AC Output Modules Cat. No.

Outputs

Voltage

6ES5 451-8MD11

4

115…230V AC

6ES5 455-4UA12

16

24…60V AC

6ES5 456-4UA12

16

115…230V AC

6ES5 456-4UB12

8

115…230V AC

6ES5 458-4UC11

16

250V AC (Relay)

Siemens S5 Digital Relay Modules Cat. No.

Outputs

Voltage

6ES5 452-8MR11

4

Relay 30V DC / 230V AC

6ES5 452-8MR11

8

Relay 30V DC / 230V AC

6ES5 458-8MR12

16

Relay 250V AC

ControlLogix Digital AC Modules

22

Cat. No.

Outputs

Voltage

1756-ON8

8

10…30 V AC

1756-OW16I

16

10…265V AC 5…150V DC Relay

1756-OX8I

8

10…265V AC 5…150V DC Relay

Publication LOGIX-AP010B-EN-P - May 2010

Page 23

Controllers and I/O Modules

Analog Input/Output Modules

Chapter 1

When converting from a Siemens S5 Controller to a Rockwell Automation Logix Controller, it is essential to choose analog input/output modules that will be compatible with existing analog input/output devices. Some of the S5-135U and S5-155U analog input modules are used in conjunction with range cards, with range cards being used depending on the type of signal being produced by the analog input device as shown in the following tables. Siemens S5 Analog Input Modules Cat. No.

Channels

Range / Sensor

460-4UA13

8 – single

See range cards

465-4UA12

16 – voltage/current 8 – Pt100 resistance

See range cards

465-4UA13

16 – voltage/current 8 – Pt100 resistance

See range cards

463-4UA12

4 – single

0…1V, 10V, 20 mA

463-4UB12

4 – single

4…20 mA

466-3LA11

16 – voltage/current 8 – Pt100 resistance

0…1.25V, 2.5V, 5V, 10V

466-4LA11

16 – voltage/current 8 – Pt100 resistance

0…20 mA 4…20 mA

Siemens S5 Analog Input Range Cards Cat. No.

Range Cards

Range / Sensor

460-4UA13

498-1AA11

±12.5, 50, 500 mV, Pt100

465-4UA12

498-1AA11

± 50/500 mV, Pt100

498-1AA21

± 1V

498-1AA31

± 10V

498-1AA41

± 20 mA

498-1AA51

4…20 mA

498-1AA61

± 5V

498-1AA71

4…20 mA

465-4UA13

Publication LOGIX-AP010B-EN-P - May 2010

23

Page 24

Chapter 1

Controllers and I/O Modules

All I/O configuration is done from the project tree of the RSLogix 5000 software. When selecting an analog module, a list of available analog modules is displayed as shown in the following dialog box.

The Logix 1756 Analog Input Modules are listed in the following table. Logix Analog Input Modules Cat. No.

Description

1756-IF8

8 channel non-isolated voltage/current

1756-IF6CIS

6 channel isolated current sourcing

1756-IF6I

6 channel isolated voltage/current

1756-IF16

16 channel non-isolated voltage/current

1756-IF4FXOF2F

4 current/volt inputs 2current/volt outputs

1756-IR6I

6 channel isolated RTD

1756-IT6I

6 channel isolated thermocouple

1756-IT6I2

6 channel isolated thermocouple enhanced

Logix analog input modules provide greater flexibility than the Siemens S5 counterparts because they can be configured in software, enabling them to receive input signals from the analog input devices. The dialog box on the next page shows that by accessing the properties of an analog module, the signal range, along with the high/low voltage current limits for the analog signal, can be modified for each channel. The Logix analog input modules also allow scaling of the raw signal to the required engineering units and configure alarm limits via the Alarm Configuration tab.

24

Publication LOGIX-AP010B-EN-P - May 2010

Page 25

Controllers and I/O Modules

Chapter 1

These modules are supplied with standard calibration but can be recalibrated on a module or channel-by-channel basis for greater accuracy in applications.

Siemens S5 Analog Output Modules Cat. No.

Channels

Range

470-4UA12

8

± 10V 0…20mA

8

± 10V

8

1…5V 4…20mA

470-4UA13 470-4UB12 470-4UB13 470-4UC12 470-4UC13

The Logix 1756 Analog Output Modules are listed in the following table. Logix Analog Output Modules Cat. No.

Description

1756-OF4

4 channel non-isolated voltage/current

1756-OF6CI

6 channel isolated current

1756-OF6VI

6 channel isolated voltage

1756-OF8

8 channel non-isolated voltage/current

1756-OF8H

8 channel voltage/current (HART)

Logix analog output modules provide added flexibility because they can also be configured in software, allowing selection of the required output range for the process device.

Publication LOGIX-AP010B-EN-P - May 2010

25

Page 26

Chapter 1

Controllers and I/O Modules

The following dialog box shows how, by accessing the properties of an analog output module, the output signal range can be modified and the high/low voltage/current limits set for each analog output channel. The Logix analog output modules also provide scaling to convert the engineering units to the required raw values and configuration of the alarm limits via the Alarm Configuration Tab. These modules are supplied with standard calibration but can be recalibrated on a module or channel-by-channel basis for greater accuracy in applications.

The 1756-OF8H module includes the Highway Addressable Remote Transducer (HART) protocol that provides additional field data and device status information from HART devices connected to this module. Addressing of the Siemens S5 Analog Modules is done by switches on the side of the modules. Addressing of Logix Analog modules is done automatically. When an analog module is added, the tags that address the module are automatically created, as shown in the following dialog box.

26

Publication LOGIX-AP010B-EN-P - May 2010

Page 27

Controllers and I/O Modules

Chapter 1

The programmer can then create new tags with recognizable tag names that describe the associated process signals to alias the analog module tags. These new alias tags will contain the same data as the analog module tags they alias. The following dialog box shows eight analog input channels from an analog input module for which alias tags were created.

Logix Controller with S5 I/O For customers to be able to migrate from S5 to current RA Technology within their time and budget constraints, while mitigating their risk of production downtime, a “phase-in” solution is possible by using variable ‘Siemens network’ linking modules (for example, Profibus DP network).

In the following section we will discuss some scenarios on how to connect to Legacy S5 hardware. The communication to S5 I/O and peer-to-peer communication is covered. In these scenarios, the profibus scanners (in rack modules) are mostly used for communication to Legacy S5 I/O while the stand-alone modules are more for peer-to-peer communication between S5/S7 PLCs and Logix controllers.

CompactLogix controllers A CompactLogix system can be used when converting a S5 system to a Logix-based platform, especially for small and standalone applications. For these applications, consider upgrading the S5 I/O immediately to Logix I/O together with the controller. Publication LOGIX-AP010B-EN-P - May 2010

27

Page 28

Chapter 1

Controllers and I/O Modules

If the S5 I/O must be maintained temporarily, communication modules for the CompactLogix range can connect to all sorts of networks (such as Profibus DP). Suppliers of ControlLogix communication modules for third party networks usually provide communication modules for the CompactLogix platform, too. For more details, please examine the encompass partner websites. See Appendix A for available communication modules for the ControlLogix platform with similar functionality as the CompactLogix modules.

ControlLogix controllers To limit migration risks, a phased migration can be done where the S5 controller is replaced by a ControlLogix controller, but where the S5 I/O (local S5 rack, S5 extension racks, S5 remote racks) is maintained temporarily. This approach allows for fast rollback scenarios and for shorter development cycles; that is, no installation, wiring, and testing of field I/O is required. The S5 I/O can be phased out gradually once the new controller is running. Integrating the S5 hardware in the Logix architecture is possible through these three communication methods: • I/O in local rack/extension rack To be able to communicate with these I/O cards, they must be made available to a network. Therefore, new Profibus DP communication cards can be slotted in the S5 chassis to make each chassis available to the Profibus DP network. In the local (main) rack, simply replace the controller by a Profibus DP slave module. In the extension racks also replace the proprietary interface card by a Profibus DP slave module.

28

Publication LOGIX-AP010B-EN-P - May 2010

Page 29

Controllers and I/O Modules

Chapter 1

• Remote I/O Most remote I/O racks are connected to the Profibus DP network, so no changes are needed. When the remote I/O connects to another network (for example, Legacy Siemens network), the interface module must be replaced by a Profibus DP slave module. • Peer-to-peer communication Because not all controllers can be migrated simultaneously, you may need to exchange data between the new ControlLogix controllers and other S5 controllers (for example, interlocking or handshaking). To accommodate this, several options are available. – A Profibus DP communication module placed in the ControlLogix chassis to communicate with master and slaves on the Profibus DP network. – A standalone module (gateway) that provides a transparent pass for the data between two networks (for example, Ethernet/IP to Profibus DP). They do not change the data sequence or the data itself. – A module placed in the Logix chassis that connects and transfers monitoring and control data between islands of automation across diverse platforms, networks and protocols. Additional message-specific controller programming with this solution is unnecessary. The module can be configured for the right data mapping. See Appendix A for more information on the possible modules to use.

S5 Controller with Logix I/O Rockwell Automation 1794-FLEX I/O series is a small, modular I/O system for distributed applications that perform all functions of rack-based I/O. The FLEX I/O system consists of power supply, terminal base and I/O modules. By using this I/O system with the 1794-APB Flex I/O Profibus adapter, it is possible to make the I/O available on a Profibus network. The S5 controller can be configured as a Profibus Master and communicate to the I/O via Profibus. The configuration of the S5 controller will be dependant on the model of S5 controller used. Prosoft also provides modules to link Logix modules to Profibus.

Publication LOGIX-AP010B-EN-P - May 2010

29

Page 30

Chapter 1

Controllers and I/O Modules

Notes:

30

Publication LOGIX-AP010B-EN-P - May 2010