Simatic S5 to RSLogix 5000 Application Conversion Guide, pages 127 to 140

Pages 127 to 140 of 140: Appendix A: Other Communication Modules; Back Cover/Rockwell Support

The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Siemens 6ES5-431-8MA11, Siemens 6ES5-451-8MA11 and Siemens 6ES5-452-8MR11

Page 127

Appendix

A

Other Communication Modules

Introduction

This section contains an overview of the available modules that provide communication to S5 I/O and peer-to-peer communication. If you are using a protocol to which you want to connect but is not described in this manual, please check the websites of our encompass partners (such as Woodhead/Molex, ProSoft, or HMS).

In-rack Modules

This section contains an overview of the available ControlLogix in-rack modules that provide communication to S5 networks.

Profibus Network This section describes modules that connects to a Profibus network.

Woodhead/Molex SST-PFB-CLX-RLL DP One way of connecting to S5 I/O on Profibus is using a PROFIBUS DP Scanner for the Logix Controller in the main rack. This is a third-party module produced by Brad Communications (Molex/ Woodhead, Part Number SSTPFB-CLX-RLL), which works with RSLinx software 2.2 OEM/Professional or later. This module slots directly into a local or remote ControlLogix chassis. It enables communication between a CLX processor and DP remote I/O devices on a PROFIBUS network, acting as a PROFIBUS DP remote I/O scanner. The SST-PFB-CLX-RLL DP supports a maximum of 125 slaves with a maximum of 244 bytes of input data and 244 bytes of output data per slave and it operates on all Profibus data rates up to 12 Mbps. As a Master, it supports up to a maximum of 1984 bytes of input data and 1968 bytes of output data within four I/O pages. The SST-PFB-CLX-RLL can act on a PROFIBUS network as a DPV1 Class 1 & Class 2 master via generic CIP messages (manages up to 16 simultaneous Class 1 commands and up to 16 simultaneous Class 2 commands and up to 32 simultaneous Class 2 connections). The module can also act as a DPV0 slave.

Publication LOGIX-AP010B-EN-P - May 2010

127

Page 128

Appendix A

Other Communication Modules

The Profibus DP/PA Network can be configured by the free SST Configuration Tool. The firmware is field-upgradeable with the HyperTerminal. More information on this module can be found at the website http://www.woodhead.com. For software/firmware/manual downloads, go to http: www.mysst.com/download.

ProSoft MVI56-PDPMV1 The MVI56 Profibus DPV1 Master Communication Module is a powerful communication interface for ControlLogix platform processors. The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, so processors can easily communicate with slave devices supporting Profibus DPV0/V1 protocol. The module acts as an input/output module between the Profibus network and the ControlLogix processor. Data transfer from the processor is asynchronous with

128

Publication LOGIX-AP010B-EN-P - May 2010

Page 129

Other Communication Modules

Appendix A the I/O data transfer on the Profibus network. It supports all standardized baud rates, up to 12 Mbps. MVI56-PDPMV1 Specifications Specification Type

Description Single Slot-1756 backplane compatible. The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module.

General

Ladder Logic is used for data transfer between module and processor. Sample ladder file (add-on instruction) included. Local or remote rack. Configurable I/O backplane sizes allow optimal performance for remote rack applications. CIPconnect (tm) enabled. Module supports communication with ProSoft Configuration Builder and FDT comDTM via Ethernet routing by using Rockwell Automation Ethernet interface. Up to 125 Slaves can be connected with a repeater. Up to 1536 cyclic bytes input and 1536 bytes output data. Supports Extended Diagnostic Data. RS-485 optically isolated Profibus Interface with on board DC-DC converter.

Profibus DP Master

Acyclic communication (DPV1), Read and Write. Alarm Handling (DPV1). Supports Sync and Freeze commands. Supports PROFIdrive 3.1 compliant parameter read and write operations. Supports Multicast and Broadcast telegrams (DPV1).

Siemens Industrial Ethernet/Modbus TCP/IP This section describes modules that connects to a Siemens Industrial Ethernet/Modbus network.

ProSoft ILX56-MM The ProSoft Technology inRAx Message Manager is a single-slot solution that connects and transfers factory and plant process-automation monitoring and control data between islands of automation across diverse platforms, networks and protocols. The inRAx Message Manager is an easy-to-use data transfer engine for the ControlLogix 1756 platform, supporting Rockwell Automation Programmable Logic Controller (PLC) and Programmable Automation Controller (PAC) network protocols, and platforms and devices that use Siemens Industrial Ethernet and Modbus TCP/IP protocols.

Publication LOGIX-AP010B-EN-P - May 2010

129

Page 130

Appendix A

Other Communication Modules

The ILX56-MM makes it easy for system integrators and end users to reduce the engineering effort required to coordinate data transfers between multiple control systems in Factory and Plant Automation applications. The Message Manager simplifies and streamlines data connection and transfer operations by enabling PLC/PAC data exchanges without the need for additional messagespecific PLC programming.

130

Publication LOGIX-AP010B-EN-P - May 2010

Page 131

Other Communication Modules

Appendix A

Protocols Supported Modbus TCP/IP and Siemens Industrial Ethernet supported via the built-in Ethernet ports. EtherNet/IP, ControlNet, Data Highway+ (DH+) and Data Highway 485 (DH485) are supported through Rockwell Automation (RA) 1756 communication bridge modules. Data can be transferred between up to 16 individually-configurable communication-interface connections. A transfer list for data exchange can be created using source and destination tags. ILX56-MM Specifications Specification Type

Description Built-in web-based configuration utility. Requires Internet Explorer version 7 (or later) for full implementation.

General

Single slot-1756 backplane compatibility. Remove and Insert Under Power (RIUP). Local or remote rack. Scrolling display for status and diagnostics.

3964R Protocol This section describes modules that connect to 3964R protocol devices.

ProSoft MVI56-S3964R The MVI56 S3964R Protocol module from ProSoft Technology allows pointto-point communication between a ControlLogix controller (1756-L1, -L1Mx, L55, L6x) and a partner with 3964R (with or without RK512) communication capability. The 3964R protocol (with or without RK512) was designed by Siemens for bidirectional data communication through a point-to-point connection. It is a peer-to-peer protocol with read and write access. A BCC checksum ensures transfer safety. The MVI56-S3964R can communicate with or without RK512 devices by using two RS-232, RS-422 communication lines (ports). The ports operate independently from each other.

Publication LOGIX-AP010B-EN-P - May 2010

131

Page 132

Appendix A

Other Communication Modules

Ladder logic programming in the ControlLogix processor is required to enable and support the Siemens 3964R protocol functionality. The ladder program handles data encoding/decoding transferred from the module and the initiation of protocol-specific functionality in the module. Example ladder programs are provided with the module to ease the implementation of the module in the user application. MVI56 S3964R Specifications Specification Type

Description Single-slot, ControlLogix backplane compatible. Multiple modules can be placed in a rack up to the chassis power supply limit. While in 3964R with RK512 mode on PRT1 and PRT2, DB-SEND and DB-FETCH instructions can be initiated from the ControlLogix processor or received by the communication partner.

Functional

While in 3964R without RK512 mode on PRT1 and PRT2, data can be sent from the ControlLogix processor or be received from the communication partner. The maximum transfer rate is 512 bytes in any mode. Data byte swapping can be configured to adjust to a word format. While in 3964R with RK512 mode on PRT1 and PRT2, evaluation of the header information DB (data block), DW (data word) and coordination bytes 9 and 10 is possible. Communication activity and diagnostics are available through LEDs and acknowledgment telegrams.

132

Publication LOGIX-AP010B-EN-P - May 2010

Page 133

Other Communication Modules

Standalone Modules

Appendix A

This section contains an overview of the available standalone modules that provide communication to S5 network.

HMS HMS provides several linking devices to exchange data from one network to another. The device below can be used to pass data between the Ethernet/IP and Profibus DP network.

Anybus X-Gateway The X-gateways are compact devices for standard DIN rail mounting and 24 Volt industrial-power supply. They are based on the proven Anybus communication modules. Embedded into a small metal housing, the modules form an intelligent link between two industrial networks.

The Anybus X-gateways provide a transparent pass for the data between the two networks. They do not change the sequence of the data nor do they change the data itself. Input data on network 1 will appear as output data on network 2. Output data on network 1 will appear as Input data on network 2. The total amount of data transferred is limited to a maximum 512 bytes Input and 512 bytes Output data. Fast I/O data transfer with average transit times between the two networks of: 10…15 ms. The X-gateway is handling the data consistently. In-built simple configuration interface accessible via Windows Hyper Terminal. IT functions such as dynamic web server, supporting downloadable customer-specific web pages. Remote monitoring and diagnostic features for most Ethernet versions based on an integrated web server. Optional control status information added to I/O data for diagnostic purposes. Included Anybus OPC server version supports OPC Data Access (DA) v1.0, 2.05, 3.0. The X-gateways primary focus is with the transfer of cyclic I/O data between two networks. Depending on network combinations, acyclic parameter data can also be transferred (such as SDO, DPV1, PCP, or Explicit messaging).

Publication LOGIX-AP010B-EN-P - May 2010

133

Page 134

Appendix A

Other Communication Modules

ProSoft ProSoft provides several linking devices to exchange data from one network to another. The device below can be used to pass data between the Ethernet/ IP and profibus DP network.

EtherNet/IP to Profibus DP Master 5204-DFNT-PDPM The DFNT-PDPM modules are ideal for applications where EtherNet/IP connectivity can be used to integrate a Profibus DP slave device into a system. The module is a stand-alone DIN rail-mounted protocol gateway that provides one Ethernet port and one Profibus DP Slave configurable DB9F port. The Ethernet/IP (DFNT) protocol driver supports the Explicit Messaging implementation of the protocol. Userconfigurable as a Client and a Server, the EtherNet/IP port is a very powerful data-transfer tool. The Profibus DP Master protocol driver supports Master implementations of the protocol on a Mono-Master or Multi-Master network. The Ethernet communication port provides a high-speed client and server connection. Data is exchanged between the protocol drivers via an internal data file. The internal database that consists of areas for application data, status information, and configuration information. The internal database is shared between all ports on the module and is used as a conduit to pass information from a device on one network to one or more devices on another network.All functions of a Profibus Class 1 Master are supported, that is, the module acts as a central controller that cyclically exchanges information with the slaves in a defined message cycle. The Profibus Master protocol driver exists as a single-port implementation. The driver can be configured as a Class 1 Profibus Master to interface with other Profibus slave devices.

134

Publication LOGIX-AP010B-EN-P - May 2010

Page 135

Other Communication Modules

Appendix A

The unit is also used for configuration of the nodes on the PROFIBUS network. It provides access to standard and extended diagnostic information. The PROFIBUS master port can be used to continuously interface with PROFIBUS slave devices over a serial communication interface (RS-485). 5204-DFNT-PDPM Specifications Specification Type

Description Multi-drop on a Profibus DP link with other DP compatible devices Software configurable parameters: • Baud rate: 9.6 Kbps…12 Mbps • Address: 0…125 Data I/O: Up to 512 cyclic bytes (256 words) input and 512 bytes (256 words) output data Autobaud detection at all Profibus DP rates

Profibus DP Master

9-pin D-shell female Profibus DP connector Supports extended diagnostic data Can be used as active Profibus Master with Profibus PA slaves on the network Supports Sync and Freeze commands Supports Multicast and Broadcast telegrams Messaging: • PCCC on CIP • Explicit Messaging supported

Ethernet/IP

Five independent TCP server sockets permit remote clients to interact with all data contained in the module 125-word read-and-write data lengths Floating point data supported

The ProLinx Gateway also features built-in web server functionality. All Profibus and A-B/ControlLogix processor data can be accessed by any standard browser with customer-created web pages.

ProSoft Configuration Builder ProSoft Configuration Builder (PCB) provides a quick and easy way to manage module configuration files customized to meet your application needs. PCB is not only a powerful solution for new configuration files, but also lets you to import information from previously installed (known-working) configurations to new projects.

Publication LOGIX-AP010B-EN-P - May 2010

135

Page 136

Appendix A

Other Communication Modules

In-rack Interface Cards for S5 rack

To put the remote S5 I/O on the Profibus DP network, a Profibus DP slave card has to be installed in the remote S5 rack. If a S5 IM-308-C module is installed, the addressing needs to be configured with the Com Profibus software package. Because these cards are obsolete, third-party modules can also be used to put the S5 I/O on the Profibus DP network.

Efsys / A2i To provide a S5 rack connectivity to a Profibus DP network ,the following module can be used.

Open5-135U

This interface card can be slotted in a S5 rack to connect to S5 I/O modules not yet available on the Profibus network. The OPEN5 board supports most S5 digital input and output modules. However, intelligent I/O cards are not compatible with the OPEN5 Board. The card supports DPV0. The words that can be read/written simultaneously depends on the number of I/O words (number and type of cards). The limit is 244 bytes per partner (DPV0 limitation) and it operates on all Profibus data rates up to 12 Mbps. A maximum total input data size of 1984 bytes and output size of 1976 bytes combined, for DP master and slave. The response time depends on the speed of communication, the number of partners on the bus, and the number of I/O cards in the S5 rack; the minimum time is 10 ms.

136

Publication LOGIX-AP010B-EN-P - May 2010

Page 137

Other Communication Modules

Appendix A

One OPEN5 card is needed per 135U rack (main and extension rack). Insert the OPEN5 Board into the extension slot (extreme right-hand side-Slot 163).

Profibus Limitations The Profibus exchange table limits a maximum of five boards of 16 analog I/O on the analog Inputs-Outputs. An interface card for the S5 115U processor is also available.

Publication LOGIX-AP010B-EN-P - May 2010

137

Page 138

Appendix A

Other Communication Modules

Notes:

138

Publication LOGIX-AP010B-EN-P - May 2010

Page 139

This page is a scan with no text; see it in the PDF.

Page 140

Rockwell Automation Support

Rockwell Automation provides technical information on the web to assist you in using its products. At http://www.rockwellautomation.com/literature, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support.

Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your module up and running. United States

1.440.646.3223 Monday – Friday, 8am – 5pm EST

Outside United States

Please contact your local Rockwell Automation representative for any technical support issues.

New Product Satisfaction Return Rockwell tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning, it may need to be returned. United States

Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) for your distributor to complete the return process.

Outside United States

Please contact your local Rockwell Automation representative for return procedure.

RSLogix, RSLogix 5000, Logix5000, RSLinx, FactoryTalk View, CompactLogix, ControlLogix, GuardLogix, FlexLogix, DriveLogix, SoftLogix, Compact I/O, POINT I/O, ArmorPoint I/O, ArmorBlock MaXum, FLEX I/O, FLEX Ex, NetLinx, Integrated Architecture, Encompass, SLC 500, MicroLogix, PLC-2, PLC-3, PLC-5, SynchLink, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication LOGIX-AP010B-EN-P - May 2010140 Copyright © 2010 Rockwell Automation, Inc. All rights reserved.