Order numbers and accessories
Table B-1
Order numbers for the DP/DP Coupler Component
DP/DP Coupler
Order number 6ES7 158-0AD01-0XA0
DIN rail 35 mm
• • • •
483 mm
6ES5 710-8MA11
530 mm
6ES5 710-8MA21
830 mm
6ES5 710-8MA31
2000 mm
6ES5 710-8MA41
Rail for the S7 mounting system
• • • •
482 mm
6ES7 390-1AE80-0AA0
530 mm
6ES7 390-1AF30-0AA0
830 mm
6ES7 390-1AJ30-0AA0
2000 mm
6ES7 390-1BC00-0AA0
Bus connector for PROFIBUS DP
• for looping the PROFIBUS DP
6ES7 972-0BA12-0XA0 6ES7 972-0BA50-0XA0 (FastConnect)
• for looping the PROFIBUS DP
6ES7 972-0BB12-0XA0 6ES7 972-0BB50-0XA0 (Fast Connect)
(without PG socket) (with PG socket)
PROFIBUS DP bus cable
• Normal (flexible)
DP/DP Coupler A5E00244669-03
6XV1 830-0EH10
B-1
Page 96
Order numbers and accessories
B-2
DP/DP Coupler A5E00244669-03
Page 97
Glossary Address The address of a node is used to identify it on the network. It must be unique throughout the entire system.
Equipment, electrical Components, electrical circuits or parts of electrical circuits which are usually contained in a single enclosure.
Bus Shared data transfer path to which all nodes are connected; with two defined end points.
Bus connector Physical connection between the bus node and the bus cable.
Chassis ground Chassis ground is formed by the interconnection of inactive equipment parts, which can not acquire any hazardous contact voltage in the event of a malfunction.
Diagnostics Diagnostics is the detection, localization, classification, indication and analysis of errors, faults and messages. The diagnostics system provides automatic monitoring functions for system runtime. This increases the availability of systems by reducing startup times and downtimes.
DP master A ³ master that responds in accordance with IEC 61784-1:2002 Ed1 CP 3/1 is referred to as a DP master.
DP/DP Coupler A5E00244669-03
Glossary-1
Page 98
Glossary
DP standard Represents the bus protocol of the DP system in accordance with IEC 61784-1:2002 Ed1 CP 3/1.
DP slave This ³ slave type is operated on PROFIBUS based on the PROFIBUS DP protocol, and responds in accordance with IEC 61784-1:2002 Ed1 CP 3/1.
Earth Conductive earth, the electrical potential of which can be set equal to zero at any point.
Electromagnetic Compatibility (EMC) Electromagnetic compatibility is the capability of electrical equipment to work free of problems in a defined environment without affecting its environment in an impermissible manner.
Equipotential bonding An electrical connection (equipotential conductor) that keeps the body of electrical equipment and external conductive bodies at the same or close to the same potential, in order to prevent the development of interference or hazardous voltages between these bodies.
Grounding Grounding means connecting an electrically conductive component to ground by means of a grounding system.
GSD file All slave-specific characteristics are stored in a GSD file. The format of the GSD file is defined in the PROFIBUS Guideline: Specification for PROFIBUS Device Description and Device Integration Vol.1: GSD V4.1, 07/2001 of the PROFIBUS User Organisation (PUO).
HW Config Hardware configuration component in STEP 7.
Glossary-2
DP/DP Coupler A5E00244669-03
Page 99
Glossary
Master Masters in possession of the token may transmit data to other nodes, and request data from other nodes (= active node). The CPU 315-2 DP or IM 308-C are Dp masters, for example.
Parameter assignment Parameter assignment is the passing of slave parameters from the master to the slave.
Power supply unit This unit supplies power to the field devices and their process peripherals.
PROFIBUS Process field bus standard that is defined in the field bus standard to IEC 61784-1:2002 Ed1 CPF 3 PROFIBUS and PROFInet. It defines functional, electrical and mechanical properties for a bit-serial field bus system. PROFIBUS is available with the following protocols: DP (for distributed I/O systems) and FMS (= Fieldbus Message Specification).
PROFIBUS address Each bus node must be assigned a PROFIBUS address that uniquely identifies it on the PROFIBUS-DP. The PC / PG or hand-held ET200 are assigned the PROFIBUS address “0”. The PROFIBUS address of the DP masters and DP slaves lie within the range from 1 to 125.
PROFIBUS DP This is the PROFIBUS system based on the DP protocol. The abbreviation DP stands for Distributed Peripherals.
PUO PROFIBUS user organization
Reference potential Electrical potential that forms the reference for viewing and/or measuring the voltage of relevant circuits.
DP/DP Coupler A5E00244669-03
Glossary-3
Page 100
Glossary
SELV Safety extra-low voltage (SELV) is a voltage of vv 30 V AC / 60 V DC generated by means of a safety isolating transformer, battery, etc.
TN-S system In a TN-S system, the neutral conductor (N) and protective conductor (PE) are routed separately. The neutral conductor is always connected to the grounded protective conductor at a central point. The conductor can be grounded any number of times.
Terminating resistor Terminating resistors are used to terminate the data transmission line in order to avoid reflections.
Transmission rate The transmission rate defines the number of transmitted bits per second.
Ungrounded without galvanic connection to earth
Glossary-4