Page 87

4–19 Bases, Expansion Bases, and I/O Configuration

Total I/O: 72 020 to 027

010 to 017

000 to 007

100 to 107

070 to 077

060 to 067

050 to 057

030 to 037

020 to 027

010 to 017

000 to 007

130 to 137

120 to 127

110 to 117

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 to 167

150 to 157

140 to 147

C P U

DL305

BASE BASE 1,3 2

040 to 047

DL305

BASE BASE 1,3 2

5 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Bases and Expansion Bases

030 to 037

Bases and Expansion Bases

5 Slot Base and 5 Slot Expansion Base with 8 Point I/O

Total I/O: 128

BASE BASE 1,3 2

DL305

DL305

DL340 only *NOTE: If a 16pt module is used in the last two available slots of the expansion base, 160 through 177 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C177 in DirectSOFT.

REV A–1

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

C P U

Page 88

4–20 5 Slot Base and Two 5 Slot Expansion Bases with 8 Point I/O

Total I/O: 112 030 to 037

020 to 027

010 to 017

000 to 007

100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

DL305

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

DL305

030 to 037

020 to 027

010 to 017

000 to 007

070 to 077

060 to 067

050 to 057

040 to 047

170 to 177

160 150 to to 167 157

140 to 147

120 to 127

110 to 117

C P U

DL305

BASE BASE 1,3 2

Bases and Expansion Bases

Bases and Expansion Bases

Bases, Expansion Bases, and I/O Configuration

BASE BASE 1,3 2

BASE BASE 1,3 2

5 Slot Base and Two 5 Slot Expansion Bases with 16 and 8 Point I/O

Total I/O: 128

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

130 to 137

100 to 107 BASE BASE 1,3 2

C P U

DL305

DL305

DL340 only DL305

BASE BASE 1,3 2

*NOTE: If a 16pt modules are used in the second expansion base as shown, 160 through 177 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C177 in DirectSOFT.

REV A–1

Page 89

4–21 Bases, Expansion Bases, and I/O Configuration

The configurations below show an 8 slot base with 8 point I/O modules, 16 point modules, one 5 slot expansion base and two 5 slot expansion bases. 8 Slot Base with 8 Point I/O

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6

5

4 3

2

1 0

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

740 to 747

730 to 737

720 to 727

710 to 717

700 to 707

DL305

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6

5

4 3

2

1 0

740 to 747

730 to 737

720 to 727

700 to 707

DL305

C P U

DL305

C P U

DL305

C P U

DL305

Total I/O: 112 *See note below regarding points 160–167

8 Slot Base and 5 Slot Expansion Base with 8 Point I/O

060 to 067

Total I/O: 96 000 to 007

Total I/O: 152 *See note below regarding points 160–167

710 to 717

C P U

DL305

BASE BASE 1,3 2

*NOTE: If a 16pt module is used in Slot 6, 160 through 167 will not be available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C167 in DirectSOFT.

Bases, Expansion Bases and I/O Configuration

BASE BASE 1,3 2

8 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Bases and Expansion Bases

8 Slot Base with 16 Point I/O

Total I/O: 56

Bases and Expansion Bases

I/O Configurations with an 8 Slot Local CPU Base

Page 90

4–22

Bases and Expansion Bases

Bases and Expansion Bases

Bases, Expansion Bases, and I/O Configuration

I/O Configurations with a 10 Slot Local CPU Base

Switch settings

The configurations below and on the next few pages show a 10 slot base with 8 point I/O modules, with 16 point modules, with a 5 slot expansion base and with a 10 slot expansion base. The 10 slot base has two jumper switches to select the base type and the address ranges to use. These switches can be found on the base between slots 3 and 4 (SW1) and slots 9 and 10 (SW2). Jumper switch SW1 is used to select if the base is a local CPU base or an expansion base. Jumper switch SW2 determines the I/O address range (100 – 107 or 700 – 707) for the 10th slot on the local CPU base. By selecting the address range of 700 to 707 for slot 10, it is possible to use a 16 point module next to the CPU (which uses the ranges of 000 to 007 and 100 to 107), however; the position of this switch will affect the I/O numbering for the expansion I/O if used. NOTE: Jumper switch SW2 must be set to “100 EXP” on the expansion base.

Last Slot Address Range 100 to 107

Total I/O: 72 Jumper SW2 100 700

Jumper SW1

EXP

EXP

Bases, Expansion Bases and I/O Configuration

100 to 107

Last Slot Address Range 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

C P U

CPU

DL305

Total I/O: 72 Jumper SW2 100

700

Jumper SW1

EXP

EXP 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

C P U

DL305

CPU

Page 91

4–23 Bases, Expansion Bases, and I/O Configuration

Configuration 1

Configuration 1 shows an 8 point I/O module the slot next to the CPU and the address range of 100–107 for the last slot. When jumper switch SW2 is set to the “100 EXP” position, the address range for the last slot is set to 100–107, thereby limiting the address range for the first module to 000–007. This means if you use this configuration, the first module must be an 8 point I/O module. You will have more available addresses for an expansion base as you will see in the example using a 10 slot expansion base. Total I/O:128

Configuration 1

Jumper SW2

Jumper SW1

100 EXP

700

EXP 100 to 107

*See note below regarding points 160–167 and 170–177.

Configuration 2

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

170 to 177

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

6 5

4

3 2

8 7 DL340 only

000 to 007

C P U

DL305

1 0

Configuration 2

Jumper SW2 700

Jumper SW1

100 EXP

EXP 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

170 to 177

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6 5

4

8 7 DL340 only

3 2

C P U

CPU

DL305

1 0

*NOTE: If a 16pt module is used in Slot 6 for the DL330 or DL330P CPU, 160 through 167 will not be available for control relay assignments. If a 16pt module is used in Slot 6 and/or Slot 7 for a DL340 CPU, 160–167 and/or 170–177 are not available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C167/C170–C177 in DirectSOFT.

Bases, Expansion Bases and I/O Configuration

Configuration 2 shows a 16 point I/O module in the slot next to the CPU and the address range of 700–707 for the last slot. This is the maximum I/O configuration for a 10 slot local CPU base. When jumper switch SW2 is set to the “700” position the address range for the last slot is set to 700–707 making addresses 000–007 and 100–107 available for use in the first slot. The position of jumper switch SW2 can limit the amount of I/O addresses available to the larger expansion bases since expansion I/O numbering would normally start with address 700.

Total I/O: 136

*See note below regarding points 160–167 and 170–177.

CPU

Bases and Expansion Bases

The next two configurations show a local CPU base using 16 point I/O modules and the two possibilities for how to configure the base to use the maximum number of I/O points.

Bases and Expansion Bases

10 Slot Expansion Base with 16 Point I/O

Page 92

4–24 Bases and Expansion Bases

Bases, Expansion Bases, and I/O Configuration

10 Slot Base and 5 Slot Expansion Base with 16 Point I/O

Total I/O: 176 Jumper SW2 700

Jumper SW1

100 EXP

EXP 700 to 707

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

170 160 to to 177 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

6 5

4

Bases, Expansion Bases and I/O Configuration

Bases and Expansion Bases

8 7 750 to 757

740 to 747

730 to 737

720 to 727

710 to 717

3 2

C P U

CPU

DL305

1 0 DL340 only

DL305

BASE BASE 1,3 2

*NOTE: If a 16pt module is used in Slot 6 for the DL330 or DL330P CPU, 160 through 167 will not be available for control relay assignments. If a 16pt module is used in Slot 6 and/or Slot 7 for a DL340 CPU, 160–167 and/or 170–177 are not available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C167/C170–C177 in DirectSOFT.

Page 93

4–25 Bases, Expansion Bases, and I/O Configuration

10 Slot Base and 10 Slot Expansion Base with 8 Point I/O

Total I/O: 152 Jumper SW2

Jumper SW1

100 EXP

EXP 100 to 107

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

DL305

C P U

SW2 700

SW1 100 EXP

EXP 760 to 767

750 to 757

740 to 747

730 to 737

720 to 727

710 to 717

700 to 707

130 to 137

120 to 127

110 to 117

CPU

DL305

Total I/O: 184 Jumper SW2 700

100 EXP

Jumper SW1 8 7

6 5

4

070 to 077

060 to 067

050 to 057

040 to 047

030 to 037

020 to 027

010 to 017

000 to 007

170 to 177

160 to 167

150 to 157

140 to 147

130 to 137

120 to 127

110 to 117

100 to 107

SW2 700

3 2

1 0

EXP

C P U

DL305

SW1

DL340 only

100 EXP 760 to 767

750 to 757

740 to 747

730 to 737

720 to 727

710 to 717

700 to 707

CPU

EXP

CPU

DL305

*NOTE: If a 16pt module is used in Slot 6 for the DL330 or DL330P CPU, 160 through 167 will not be available for control relay assignments. If a 16pt module is used in Slot 6 and/or Slot 7 for a DL340 CPU, 160–167 and/or 170–177 are not available for control relay assignments. Also, even though you are using these points as I/O, you still enter them as C160–C167/C170–C177 in DirectSOFT.

Bases, Expansion Bases and I/O Configuration

10 Slot Base and 10 Slot Expansion Base with 16 Point I/O

CPU

Bases and Expansion Bases

700

Bases and Expansion Bases

I/O addresses change depending on the point configuration in the local CPU base. Expansion Addresses Depend Notice, when the local CPU base contains only 8 point I/O modules, addresses on Local CPU Base 110–117, 120–127 and 130–137 are available for use in the expansion base. When the local CPU base has 16 point I/O modules, which use the I/O addresses 110–117, Configuration. 120–127 and 130–137, these addresses are taken up and are not available for use in the expansion base.

Page 94

4–26 Calculating the Power Budget Managing your Power Resource

Bases and Expansion Bases

Bases and Expansion Bases

Bases, Expansion Bases, and I/O Configuration

When you determine the types and quantity of I/O modules you will be using in the DL305 system it is important to remember there is a limited amount of power available from the power supply. We have provided a chart to help you easily see the amount of power available with each base. The following chart will help you calculate the amount of power you need with your I/O selections. At the end of this section you will also find an example of power budgeting and a worksheet for your own calculations. If the I/O you choose exceeds the maximum power available from the power supply you can resolve the problem in one of two ways: S Shift some of the modules to an expansion base which contains another power supply. S If a 5 slot base is being used, replace it with an 8 or 10 slot base. This will provide more power on the 9V and 24V power supplies. WARNING: It is extremely important to calculate the power budget. If you exceed the power budget, the system may operate in an unpredictable manner which may result in a risk of personal injury or equipment damage.

Auxiliary Base Power Source

Bases, Expansion Bases and I/O Configuration

Base Power Specifications

There is 24 VDC available from the 24 VDC output terminals on the bases (except D3–05BDC). The 24 VDC can be used to power external devices or DL305 modules that require external 24 VDC. The power used from this supply reduces the internal system 24 VDC available to the modules by an equal amount. When using the 24 VDC output at the base terminal it is not recommended to exceed 100mA. This chart shows the amount of current available for the three voltages supplied on DL305 bases. Use these currents when calculating the power budget for your system.

Bases

5V Power Supplied in mA

9V Power Supplied in mA

24V Power Supplied in mA

Auxiliary 24 VDC Output at Base Terminal

D3–05B

1400

800

500

Yes

D3–05BDC

1400

800

500

None

D3–08B

1400

1700

600

Yes

D3–10B

1400

1700

600

Yes

NOTE: The total current for the D3–05B and D3–05BDC should not exceed 2.3 Amps. The base currents listed for the D3–08B and the D3–10B are for operating ambient temperatures between 0° C and 50° C.

Page 95

4–27 Bases, Expansion Bases, and I/O Configuration

The next three pages show the amount of maximum current required for each of the DL305 modules. The column labeled “External Power Source Required” is for module operation and is not for field wiring. Use these currents when calculating the power budget for your system. If 24 VDC is needed for external devices, the 24 VDC (100mA maximum) output at the base terminal strip may be used as long as the power budget is not exceeded. 5V Power Required in mA

9V Power Required in mA

24V Power Required in mA

External Power Source Required

D3–330

300

50

0

None

D3–330P

300

50

0

None

D3–340

300

20

0

None

F3–OMUX–1

300

0

0

None

F3–OMUX–2

300

0

150

None

F3–PMUX

500

0

0

None

F3–RTU

300

0

0

0

D3–08ND2

0

10

112

None

D3–16ND2–1

0

25

224

None

D3–16ND2–2

0

24

209

None

D3–16ND2F

0

25

224

None

F3–16ND3F

0

148

68

None

D3–08NA–1

0

10

0

None

D3–08NA–2

0

10

0

None

D3–16NA

0

100

0

None

D3–08NE3

0

10

0

None

D3–16NE3

0

130

0

None

Bases and Expansion Bases

Module Power Requirements

CPUs

Bases and Expansion Bases

Specialty CPUs

DC Input Modules

AC/DC Input Modules

Bases, Expansion Bases and I/O Configuration

AC Input Modules

Page 96

4–28

Bases and Expansion Bases

Bases and Expansion Bases

Bases, Expansion Bases, and I/O Configuration

Module Power Requirements (continued)

5V Power Required in mA

9V Power Required in mA

24V Power Required in mA

External Power Source Required

D3–08TD1

0

20

24

None

D3–08TD2

0

30

0

None

D3–16TD1–1

0

40

96

None

D3–16TD1–2

0

40

96

None

D3–16TD2

0

180

0

None

D3–04TAS

0

12

0

None

F3–08TAS

0

80

0

None

D3–08TA–1

0

96

0

None

D3–08TA–2

0

160

0

None

F3–16TA–1

0

160

0

None

D3–16TA–2

0

400

0

None

D3–08TR

0

360

0

None

F3–08TRS–1

0

296

0

None

F3–08TRS–2

0

296

0

None

D3–16TR

0

480

0

None

D3–04AD

0

55

0

24VDC @ 65mA max

F3–04ADS

0

183

50

None

F3–08AD

0

25

37

None

F3–08TEMP

0

25

37

None

F3–08THM–n

0

50

34

None

F3–16AD

0

33

47

None

D3–02DA

0

80

0

24VDC @ 170mA max

F3–04DA–1

0

144

108

None

F3–04DA–2

0

144

108

None

F3–04DAS

0

154

145

None

DC Output Modules

AC Output Modules

Bases, Expansion Bases and I/O Configuration

Relay Output Modules

Analog