The text of a manual · part 1 of 10
Class 8030 Type CRM565 Network Interface Module (For Square D PowerLogic Circuit Monitor), pages 1 to 3
Pages 1 to 3 of 50: 30598-756-01A1; Warning and Cautions; Preface
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Square D 8030-CRM-565 and Schneider 8030-CRM-565
Page 1
SQUARE D COMPANY
Instruction Bulletin
SYIMAK’
Class 8030 Type CRM565
Network Interface Module
(For Square D PowerLogic™ Circuit Monitor) Bulletin #30598-756-01A1
May, 1990
Dedicated to Growth Committed to Quality
Page 2
WARNING
The application of this product requires expertise in the design and programming of control systems. Only persons with such expertise should be allowed to program, install, alter, and apply this product. Potential bodily injury, death, or equipment damage could result if the product is improperly applied to any equipment application.
CAUTION
SY/MAX devices contain electronic components that are very susceptible to damage from electrostatic discharge. DO NOT handle this device by the gold edge contacts.
A static charge can accumulate on the surface of ordinary plastic wrapping or cushioning material. If any SY/MAX device must be returned to Square D, the following packaging instructions must be followed:
PREFERRED: Use the original packaging material as supplied by Square D. Place the device inside the metallized static-shielding bag.
ACCEPTABLE: Wrap the device in some type of antiatatic materia!. Antistatic plastic material can be identified by ita pink color, and can be obtained in sheet or bag form.
UNACCEPTABLE: Do not use ordinary plastic film, foam, or styrene chips (“popcorn™ or “peanuts”). These materials can accumulate static charges in excess of 10,000 volts, resulting in possible damage to the SY/MAX electronic components,
CAUTION
Improper handling may cause permanent damage to this device.
1) Never remove this device from the rack while power is ON. Turn power supply switch to OFF and wait until all indicating lights are off before removing.
2) Do not subject to static discharge.
3) Donot touch gold edge contacts.
NOTICE
The producta and services described in this manual are useful in a wide variety of different applications. Therefore, the user and others responsible for applying the producta and services described herein are responsible for determining their acceptability for each application. While efforts have been made to provide accurate information within this manual, the Square D Company assumes no responsibility for the application, completeness or usefulness of the information contained herein.
UNDER NO CIRCUMSTANCE WILL THE SQUARE D COMPANY OR ANY OF ITS SUBSIDIARIES BE RESPONSIBLE OR LIABLE FOR ANY DAMAGES OR LOSSES, INCLUDING INDIRECT OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM EITHER THE USE OF ANY INFORMATION CONTAINED WITHIN THIS MANUAL OR THE USE OF ANY PRODUCTS OR SERVICES REFERENCED HEREIN.
No patent liability is assumed by the Square D Company with respect to the use of any of the information, products, circuits , programming or services referenced herein.
The information contained in thia manual is subject to change without notice.
Page 3
Page - fi 30598-756-01
Preface
The Class 8030 Type CRM565 PowerLogic Network Interface Module (PNIM) ia a special SY/NET Network Interface Module (NIM) that allows complete monitoring, configuration, and control of a group or subnetwork of PowerLogic Circuit Monitors.
Square D’a PowerLogic Circuit Monitor (CM) is a multifunction instrumentation, data acquisition and control device capable of replacing conventional power distribution metering, and data acquisition equipment. Ita ability to communicate metering information via an RS-485 (RS-422 compatible) communication channel to a SY/MAX® Processor, or similar master, allows it to replace discrete meters.
The PowerLogic Circuit Monitor can be applied virtually anywhere standard current and voltage trans-formers can be used. Refer to Bulletin 63074-140-XX for detailed information concerning PowerLaogic.
How to Use This Bulletin
First time users should start with Sections 1 and 2 of this bulletin which provide basic information about the PNIM. Section 3 describes the SY/NET local area network and can be skipped by those who have experience using SY/NET.
Section 4 covera the configuration of the PNIM and of PowerLogic networka in general. It provides an overview for those who wish to set up a PowerLogic network.
Section 5 discusses network communication programming while Section 6 covers PowerLogic Circuit Monitor network operations.
Section 7 describes how the PNIM operates.
Troubleshooting information is provided in Section 8.