Page 1 of Class 8030 Type CRM565 Network Interface Module (For Square D PowerLogic Circuit Monitor)

Manual · Square D

Class 8030 Type CRM565 Network Interface Module (For Square D PowerLogic Circuit Monitor)

Manual50 pagesPDF 1.2 MB

Instruction bulletin for the Square D SY/MAX Class 8030 CRM565 network interface module that links PowerLogic circuit monitors to SY/NET.

Download the PDF1.2 MB

Covers · 2 models

The models it covers

Summary

What is in it

Square D instruction bulletin for the Class 8030 Type CRM565 PowerLogic Network Interface Module (PNIM), a SY/MAX rack module that lets SY/MAX processors and other devices on the SY/NET local network read, configure and control up to 16 PowerLogic Circuit Monitors. It gives specifications, describes the indicator lights, thumbwheel and DIP switches, network and COMM ports, then covers SY/NET and circuit monitor network configuration and wiring, SY/MAX communication programming and routing, network operations, theory of operation and troubleshooting, with cable diagrams and error codes.

Its parts

  1. Introduction
  2. Hardware Description
  3. LAN Configuration and Connections
  4. Network Configuration and Connections
  5. SY/MAX Communication Programming
  6. Network Operations
  7. Theory of Operation
  8. Troubleshooting

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Square D instruction bulletin 30598-756-01A1 (May 1990) for the Class 8030 Type CRM565 PowerLogic Network Interface Module (PNIM). The module links SY/MAX processors and the SY/NET network to up to 16 PowerLogic Circuit Monitors. It covers specifications, lights and switches, configuration, installation, communication programming, error codes, self-test and troubleshooting.

Read for this summary: pages 1 to 3, 7 to 12, 23 to 24 and 41 to 48 of 50.

What it is
PowerLogic Network Interface Module (PNIM): a SY/NET Network Interface Module that lets SY/MAX devices communicate with PowerLogic Circuit Monitors p. 7
Circuit monitors
Up to 16, daisy chained on COMM Port 0 in PowerLogic Mode (half-duplex, CRC error checking) p. 7, 11
COMM ports
Two 9-pin female D-connectors, RS-422 compatible, with RTS/CTS handshaking; Port 1 uses SY/MAX protocol p. 8, 11
COMM baud rates
1200, 2400, 4800 and 9600 p. 12
Network port
Connects to the local SY/NET network over baseband twinaxial cable, Belden 9272 or equivalent p. 8
Power
5 VDC from the SY/MAX power supply through a register slot; 950 mA current draw p. 8, 24
Compatible racks
Class 8030 Types CRK100, CRK200, CRK210, CRK300, DRK210, DRK300, GRK110, GRK210, HRK100, HRK150, HRK200, RRK100, RRK200, RRK300 p. 24
COMM distance
10,000 feet max between a COMM port and the connected device; Belden 8723 for the circuit monitor link p. 9, 12
Indicator lights
8 LEDs: NETWORK, Rx 0, Tx 0, Rx 1, Tx 1, NET Rx ERROR, NET Tx ERROR, POWER p. 10
Factory settings
Network 62.5K baud; both COMM ports SY/MAX mode at 9,600 baud; self-test disabled; network size 100; receive broadcast disabled p. 23
Temperature
Operating 32 - 140°F (0 to 60°C); storage -40 to +176°F (-40 to +80°C); humidity 5-95% noncondensing p. 8
Dimensions
Single-width module, 1.5 x 12.8 x 6.6 in (3.8 x 32.5 x 16.8 cm), W x H x D p. 8
RS-232 adapters
Class 8010 Type CRM600 Single Channel Standalone; Class 8030 CRM601 Dual Channel Rack Mount p. 11
Other parts named
Keying pin kit Class 8030 Type CBP104; test plugs Type CTP11 (Class 8010); network cable end Class 8030 Type CCK-221 p. 24, 42, 45

What this manual walks you through

  • Reading the eight indicator lights p. 10, 41
  • Setting the network address thumbwheel switches p. 10
  • Factory DIP switch settings and network size p. 23
  • Installing and keying the module in a SY/MAX rack p. 24
  • Checking COMM port activity with the LED checklist p. 41
  • Looking up communication error codes p. 42, 46
  • Running the PNIM self-test with test plugs p. 42
  • Step by step network system troubleshooting p. 43, 44
  • Assembling a network cable end on twinax cable p. 45
  • Cable wiring diagrams for CC100, CC130 and CC104 series cables p. 47

Good to know

  • The COMM ports are RS-422 and do not support RS-232C devices directly. p. 11
  • Only COMM Port 0 can talk to circuit monitors; COMM Port 1 works only in SY/MAX Mode. p. 11
  • Every module on a SY/NET network must have the same network size setting, or the whole network runs as SIZE 30. p. 23
  • Never remove the module from the rack while power is on; switch off and wait for all lights to go out. p. 2

Questions this manual answers

How many PowerLogic circuit monitors can one CRM565 handle?

Up to 16, daisy chained on COMM Port 0. p. 7

Can I plug an RS-232 device into the CRM565?

Not directly. The bulletin names RS-422 to RS-232 adapters: Class 8010 Type CRM600 and Class 8030 CRM601. p. 11

What do the NET Rx and NET Tx ERROR lights flashing together mean on the CRM565?

The self-test found an internal fault. One flash is a ROM checksum error, two a RAM error, three a serial port 0 or 1 error, four a network port error. p. 42

What does error 17 mean on a CRM565 network?

Inactive device: the remote device could not be reached, for example a wrong route number, a PNIM without power, or a loose network or COMM cable. p. 44

Which racks accept the CRM565?

It plugs into a register slot of SY/MAX racks such as the CRK, DRK, GRK, HRK and RRK types listed in the bulletin. p. 24

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 30598-756-01A11
  2. Class 8030 Type CRM5651
  3. Network Interface Module1
  4. for PowerLogic Circuit Monitor1
  5. Warning and Cautions2
  6. Preface3
  7. List of Figures6
  8. 1: Introduction7
    1. 1.1 What Is the PNIM?7
    2. 1.2 Typical Applications7
    3. 1.3 Specifications8
  9. 2: Hardware Description10
    1. 2.1 General10
    2. 2.2 Indicator Lights10
    3. 2.3 Network Address Thumbwheel Switches10
    4. 2.4 Circuit Board DIP Switches11
    5. 2.5 Network Port11
    6. 2.6 COMM Ports11
  10. 3: LAN Configuration and Connections13
    1. 3.1 Introduction13
    2. 3.2 Local Network Configuration13
    3. 3.3 NIM COMM Port Connections14
    4. 3.4 Network Port Connections15
    5. 3.5 Network Performance Considerations17
  11. 4: Network Configuration and Connections18
    1. 4.1 Circuit Monitor Network Configuration18
    2. 4.2 PNIM Configuration19
    3. 4.3 Factory DIP Switch Settings23
    4. 4.4 Module Installation and Keying24
    5. 4.5 Circuit Monitor Comm Link Connections25
  12. 5: SY/MAX Communication Programming26
    1. 5.1 General26
    2. 5.2 Communication Rungs26
    3. 5.3 Routing26
    4. 5.4 Example Rungs28
    5. 5.5 Advanced Communication Routing29
    6. 5.6 D-LOG Module Communication34
  13. 6: Network Operations35
    1. 6.1 SY/MAX and Circuit Monitor Communications35
14 more lines, from page 35 on
  1. 6.2 General Communication Rules35
    1. 6.3 General Programming Information36
  2. 7: Theory of Operation37
    1. 7.1 Power Cycling37
    2. 7.2 Message Handling37
    3. 7.3 Error Handling40
  3. 8: Troubleshooting41
    1. 8.1 Indicating Lights41
    2. 8.2 System Troubleshooting42
  4. Appendices45
    1. A: Installing a Cable End45
    2. B: Comm Error Codes46
    3. C: Cable Wiring Diagrams47
    4. D: Summary of DIP Switch Settings48

From the PDF’s own bookmarks.

The whole text · 10 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 31-3
  2. Pages 4 to 64-6
  3. 1: Introduction7-9
  4. 2: Hardware Description10-12
  5. 3: LAN Configuration and Connections13-17
  6. 4: Network Configuration and Connections18-25
  7. 5: SY/MAX Communication Programming26-34
  8. Pages 35 to 4035-40
  9. 8: Troubleshooting41-44
  10. Appendices45-50

The file

Revision and size

RevisionBulletin 30598-756-01A1, May 1990
PublisherSquare D Company
Pages50
PDF1.2 MB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

The first pages · 3 of 50

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 50
Page 2
Page 2of 50
Page 3
Page 3of 50