Manual · SVF Flow Controls
Installation, Operating & Maintenance: COMPACT 4 Piston Pneumatic Actuator
Manual12 pagesPDF 3.7 MB
IOM manual for the Compact 4-piston pneumatic actuator, sizes C15 to C75M including the C35, double-acting and spring-return.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Installation, operating and maintenance (IOM) manual for the Compact four-piston pneumatic quarter-turn rack and pinion actuator, sizes C15 through C75M including the C35 and C35M. It covers safety warnings, storage, operating conditions (lubricants, explosive environments, air supply, supply pressure, temperature), the principle of operation for double-acting and spring-return models, air connections, NAMUR solenoid mounting, indicator, ISO 5211 mounting, travel adjustment, disassembly and assembly step by step, leak testing and a part list.
From the manual · read page by page
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Habonim installation, operating and maintenance manual (issue H-03/14) for the Compact 4 piston pneumatic actuator, sizes C15, C20, C25, C30, C30M, C35, C35M, C45, C45M, C60, C60M, C75 and C75M, double acting and spring return. It does not print the SVF Flow Controls C35-SR-2C designation the site files it under. It covers storage, operating conditions, air connections, travel adjustment, disassembly, reassembly, leak testing and the parts list.
- What it is
- Pneumatic quarter-turn rack and pinion actuator with four pistons around one pinion p. 3
- Supply pressure
- Double-acting 2-8 barg (30-120 psig); spring-return 3-8 barg (40-120 psig) p. 2
- Spring return action
- Pressure into port A opens (pinion CCW, springs compressed); releasing port A lets the springs close it (pinion CW) p. 3
- Temperature
- Standard -20°C (-4°F) to +80°C (+176°F); up to 130°C (266°F) with Viton O-rings and HT grease; down to -60°C (-76°F) with LT O-rings and LT grease p. 2
- Supply medium
- Inert gases such as nitrogen, argon and natural gas, or thin hydraulic oil; never water, oxygen or hydrogen p. 2
- Rotation
- Factory adjusted to 90°; a longer set of stop screws allows travel from 0° to 20° and from 90° to 70° p. 4
- Mounting interfaces
- ISO 5211 or DIN 3337 valve mounting; NAMUR cover pad for direct solenoid mounting p. 4
- Position indication
- Indicator or puck with Namur interface on the pinion; the puck has three contact screws for position signaling p. 4
- Spring assemblies
- Standard springs in C15 to C75; loaded spring cartridges in the M models C30M, C35M, C45M, C60M, C75M p. 6, 7
- Lubricants
- NBR O-rings: EP1; Viton: Molykote 111, OKS 1110 or Phalanx EP1; EPDM: silicone grease only; LT O-rings: KLT-2 p. 2
- Materials
- Body AL 356-T6; pistons AL 356/380; covers AL 380; pinion steel E.N. coated; stop plate STST 316 p. 12
- Repair kit parts
- O-rings (piston, cover, Namur cover, pinion, top pinion, air supply, Namur insert), thrust washers, bearing, disc bearing, circlip, pads p. 12
- Nameplate
- On the body side: size, model, type, spring set, threads, indicator, options, date of manufacture, protection rating, pressure limits p. 4
What this manual walks you through
- Storing actuators before installation p. 2
- Choosing lubricants for each O-ring material p. 2
- Air connections and port A and B operation for double acting and spring return p. 3
- Mounting a NAMUR solenoid and setting the indicator arrows p. 4
- Adjusting travel with the stop screws p. 4
- Removing double acting and spring return covers, including spring cartridges p. 5, 6, 7
- Removing the pistons and the pinion p. 7, 8
- Reassembling the pinion, pistons and covers p. 8, 9, 10, 11
- Pneumatic leak testing after assembly p. 11
Good to know
- Isolate the actuator from the air supply and electrical ancillaries before any maintenance. p. 1
- On cartridge spring models, if a cover is still under tension after opening a 10 mm gap, close it again and contact Habonim. p. 6
- A spring cartridge must never be cut or taken apart; the spring set is changed only by fitting a different cartridge. p. 6
- Do not try to remove the pistons with air pressure when the covers are off. p. 1
- In the leak test, one bubble every 10 seconds to the atmosphere is acceptable; any leakage across a piston is not. p. 11
Questions this manual answers
What air pressure does a spring return Compact actuator need?
3-8 barg (40-120 psig). Double-acting models run on 2-8 barg (30-120 psig). p. 2
Which way does a spring return Compact actuator turn when air enters port A?
The pistons move outward, the pinion turns counterclockwise and the springs compress. Releasing the air lets the springs turn it back clockwise. p. 3
What temperature range can the Compact actuator work in?
Standard limits are -20°C (-4°F) to +80°C (+176°F). Viton O-rings and HT grease allow 130°C (266°F); LT O-rings and LT grease allow -60°C (-76°F). p. 2
Which parts come in the Compact actuator repair kit?
The parts list marks the O-rings, thrust washers, bearing, disc bearing, circlip and pads as spare parts in the standard repair kit. p. 12
Can the gas supply be oxygen or hydrogen?
No. The manual says oxygen or hydrogen must not be used, and water must not be used as a supply medium. p. 2
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.