The text of a manual · part 19 of 44
Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual: 7. SPECIFICATIONS, pages 150 to 159
Pages 150 to 159 of 387, from Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual
The original document is the PDF (16 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Toyopuc OUT-15 and Toyopuc OUT-18
Page 150
Address EV60 EV61 EV62
Name ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV63 EV64 EV65 EV66
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV67 EV68 EV69 EV6A
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV6B EV6C EV6D EV6E
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV6F EV70 EV71 EV72
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV73 EV74 EV75 EV76
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV77 EV78 EV79 EV7A
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
EV7B EV7C EV7D EV7E EV7F EVE00 ∼ EVEFF EVE00 ∼ EVEFF
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
Outline ⎫ ⎪ Prg3⎬ ⎪ Link1 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link2 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link3 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link4 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link5 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link6 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link7 ⎭
0: No error 1: Error
⎫ ⎪ Prg3⎬ ⎪ Link8 ⎭
0: No error 1: Error
Description
SN-I/F input data link area
SN-I/F output data link area
Note) For the communication (link) modules, see the respective Instruction Manuals.
7-31
Page 151
(3)
PC2 compatible mode
Address V01 V02 V03 V04 V05 V06
V24
Name
Outline
Description
0: No ERR0 ON against occurrence of major error MAJOR ERROR 1: ERR0 in occurring OFF after ERROR is reset 0: No ERR1 ON against occurrence of minor error. MINOR ERROR 1: ERR1 in occurring OFF after ERROR is reset. 0: No ALM ON against ALARM ALARM 1: ALM in outputting OFF after ERROR is reset. NORMALLY ON Normally 1 Normally ON irrespective of run status. NORMALLY OFF Normally 0 Normally OFF irrespective of run status. END command ON by resetting and OFF by END ON 1ST SCAN Reset processing. OFF 0: Not in dummy stopping ON by executing dummy scan stop IN DUMMY STOPPING 1: In dummy stopping OFF by resetting 0: No stop request 1: Stop requested
ON by dummy scan stop request. OFF by resetting OFF during sequence scan But ON during step-operation
V25
STOP REQ IN CONTINUING
V26
IN STOPPING
V27
RUN non-execution 1: Sequence command in executing
V39
FUN FLAG CLEAR MODE
0: Not FUN FLAG CLEAR MODE 1: FUN FLAG CLEAR MODE
ON under FUN FLAG CLEAR mode.
V3A
IN DATA BACK-UP
0: Not in data backing up 1: In data backing-up
ON while user data is being backed up
V50
APPLIED COMMAND ERROR 1 (ER)
0: No error 1: Error
ON if applied command error occurs and OFF if not, but limited to only command with confinement .
V51
<
0: Comparative result not small 1: Comparative result small
V52
=
0: Comparative result unequal 1: Comparative result equal
V53
>
0: Comparative result not large 1: Comparative result large
V54
ZERO (Z)
V55
BORROW (BO)
V56
CARRY (CY)
V5E
DATA ERROR CLEAR
V5F
DATA BACKUP START
V70
0.1 SEC CLOCK
V71
0.2 SEC CLOCK
V72
1-SEC CLOCK
V73
2-SEC CLOCK
V74
60-SEC CLOCK
0: In scanning 1: In stopping 0: Sequence command
0: Result not 0 1: Result 0 0: No digit down 1: Digit down 0: No digit up 1: Digit up 1: Data error cleared Back-up start with fall 0.05 sec 0.05 sec 0.1 sec 0.1 sec 0.5 sec 0.5 sec 1 sec 30 sec
1 sec 30 sec
7-32
ON while sequence command is in executing.
Result of comparative command of applied commands Result of comparative command of applied commands Result of comparative command of applied commands
ON when computation result of applied command is 0 The computation result of applied command is smaller than 0. The computation result of applied command is over the digit number. DATA ERROR UNCHECK ALM is cleared by turning ON this special relay (V5E). USER DATA BACK-UP is started by ON->OFF of this special relay (V5F). V3A keeps ON while the back-up is being executed. Clock of cycle 0.1 sec and duty 50% Clock of cycle 0.2 sec and duty 50% Clock of cycle 1 sec and duty 50% Clock of cycle 2 sec and duty 50% Clock of cycle 60 sec and duty 50%
Page 152
Address
Name
Outline 1 scan
V78
SCAN CLOCK
V79
USER DEFINED CLOCK 1
V7A
USER DEFINED CLOCK 2
V80
Prg1-Link1 COMMUNICATION RESET
V81
Prg1-Link2 COMMUNICATION RESET
V82
Prg1-Link3 COMMUNICATION RESET
V83
Prg1-Link4 COMMUNICATION RESET
V84
Prg1-Link5 COMMUNICATION RESET
V85
Prg1-Link6 COMMUNICATION RESET
V86
Prg1-Link7 COMMUNICATION RESET
V87
Prg1-Link8 COMMUNICATION RESET
V90
LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND Link1 ⎭ ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND ⎭ Link2 ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND ⎭ Link3 ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND Link4 ⎭ ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND Link5 ⎭ ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND ⎭ Link6 ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND ⎭ Link7 ERROR FLAG LINK COMMAND USE ⎫ Prg1PERMIT FLAG ⎬ LINK COMMAND Link8 ⎭ ERROR FLAG ALL ST IN COMMUNICATING ⎫ LINK PARAMETER ⎪ Prg1ERROR ⎬ COMMUNICATION Link1 ⎪ ERROR
V91 V92 V93 V94 V95 V96 V97 V98 V99 V9A V9B V9C V9D V9E V9F VA0 VA1 VA2
VA5 VA6
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VA7 VA8 VA9 VAA
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VAB VAC VAD VAE VAF
1 scan n scan n scan
Clock to turn ON/ OFF SCAN every 1 scan.
m scan
Clock to turn ON/OFF scan at scanning interval preset by applied command.
m scan
Clock to turn ON/OFF scan at scanning interval preset by applied command.
0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON 0: RESET OFF 1: RESET ON
0: No error 1: Error
⎭
VA3 VA4
Description
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
⎫ ⎪ Prg1⎬ ⎪ Link2 ⎭
0: No error 1: Error
⎫ ⎪ Prg1⎬ ⎪ Link3 ⎭
0: No error 1: Error
⎫ ⎪ Prg1⎬ ⎪ Link4 ⎭
0: No error 1: Error
Note) For the communication (link) modules, see the respective Instruction Manuals.
7-33
Page 153
Address VB0 VB1 VB2
Name ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VB3 VB4 VB5 VB6
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VB7 VB8 VB9 VBA
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VBB VBC VBD VBE
ALL ST IN COMMUNICATING LINK PARAMETER ERROR COMMUNICATION ERROR
VBF
Outline ⎫ ⎪ Prg1⎬ ⎪ Link5 ⎭
0: No error 1: Error
⎫ ⎪ Prg1⎬ ⎪ Link6 ⎭
0: No error 1: Error
⎫ ⎪ Prg1⎬ ⎪ Link7 ⎭
0: No error 1: Error
⎫ ⎪ Prg1⎬ ⎪ Link8 ⎭
0: No error 1: Error
VC6
PARAMETER ERROR
VC7
I/O MODULE ERROR ( Fuse blown, etc.)
0: No error 1: Error 0: No error 1: Error 0: No error 1: Error 0: No error 1: Error 0: No error 1: Error 0: No error 1: Error 0: No error 1: Error 0: No error 1: Error
VC8
I/O COMPOSITION ERROR
0: No error 1: Error
USER PROGRAM ERROR BACK UP MEMORY ERROR
0: No error 1: Error 0: No error 1: Error
VCB
DATA ERROR UNCHECK
0: Checked 1: Uncheck
VE0
I/O VERIFICATION ERROR
VC0
CPU ERROR
VC1
POWER DOWN
VC2
MEMORY DATA ERROR
VC3
I/O BUS ERROR
VC4 VC5
VC9 VCA
VE1 VF0 VF2 VF3 VF5
SPECIAL MODULE ERROR MODULE PARAMETER ERROR
Description
ON upon detection of CPU module error. ON upon detection of POWER DOWN . OFF after reset or power rethrow-in ON detection of program or parameter data error. ON upon detection of I/O bus error. ON upon detection of special module error ON after ERROR reset ON when CPU can not recognize correctly I/O module. ON upon detection of parameter error. ON upon detection of I/O module error OFF after ERROR reset ON upon detection of I/O module composition error/ ( Allocation of special card number and I/O addresses ) ON upon detection of error related to user program. OFF after ERROR reset. ON upon detection of back-up memory error ON upon detection of memory data error (VC2) . OFF with V5E ON or use of peripheral equipment. ON upon detection of SCAN TIME OVER . OFF after reset or power rethrow-in ON upon detection of SCAN TIME OVER . OFF after reset or power rethrow-in ON upon error detection OFF after ERROR reset ON against allocation error of communication (link) module.
0: No error 1: Error 0: No error SCAN TIME-OVER 1: Error 0: No error BATTERY ERROR 1: Error SPECIAL MODULE 0: No error ALLOCATION ERROR 1: Error DIAGNOSIS MODULE 0: No error ERROR 1: Error 0: No error BATTERY ERROR 1: Error
ON against diagnosis module error. ON upon detection of built-in clock error.
Note) For the communication (link) modules, see the respective Instruction Manuals.
7-34
Page 154
7.2.6 Table of special registers The special registers listed in the table below are available for special applications such as CPU status, built-in clock, link modules, etc. These special registers exit in basic area and extended area. Under data memory separate mode the special registers in basic area are available individually for each program. In this case, the special registers for built-in clock time, annunciator, link modules, etc. used in each sequence program are in special register area corresponding to the program. Other special registers are all in the special register area for "PRG.1". It is all reservation area for the address that doesn't exist in the list. Therefore, the user cannot use its address. (1-1) Data memory separate mode PRG.1 Address Name
Description
S001 S002 S003
SCAN TIME max value SCAN TIME min value SCAN TIME Present value
S004
Time (Sec)
S005
Time (Minutes)
S006
Time (Hours)
S007
Time (Day)
S008
Time (Month)
S009
Time (Year)
S00A
Day of week
S00C S00D S00E S00F
Integrated make time Integrated run time
S019 S01A S01B
End processing time max value End processing time Min value End processing time Present value Time (Minute·sec) Time (Day·Hour) Time (Year·month)
S022
1 ms timer
S023
10 ms timer
S024
100 ms timer
S010 S011 S012
S0A8 ~
Link module corde
S0AF S0C0 S0C1 S0C2
PRG.1
S0C3 S0C4 S0C5 S0C6 S0C7
PRG.2
Initial scan time SCAN TIME max value SCAN TIME min value SCAN TIME Present value Initial scan time SCAN TIME max value SCAN TIME min value SCAN TIME Present value
Maximum scan time in sequence program (ms) Binary Minimum scan time in sequence program (ms) Binary Updated scan time in sequence program (ms) Binary Present time of the built-in clock is stored. For data display, 1 digit is displayed by 1Byte in BCD code. (Ex. "0102" represents "12".) Year data is displayed with lower two digits of AD year. "day of week" data is represented by 0 ~ 6, which correspond to Sun. ~ Sat. BCD Even if the register is rewritten directly, time change (1 digit/byte) is impossible.Please perform a setup of time from <Setup data/time> of Pcwin or use an exclusive use of an application instruction. (Please refer to "309 SYS Clock adjustment instruction(FUN300) PC3J series since version 2.6" in "PROGRAMMING MANUAL" about an application instruction. ) Binary, lower Cumulative value of CPU module make (current feed) time (h) Binary, upper Binary, lower Cumulative value of sequence program run time (h) Binary, upper Maximum end processing time in sequence program (ms)
Binary
Minimum end processing time in sequence program (ms)
Binary
Updated end processing time in sequence program (ms)
Binary
Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code.(Ex. "1234" represents "12 (min).34(sec).) This timer works by 1 ms as 0 seconds when the power supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 10 ms as 0 seconds when the power supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 100 ms as 0 seconds when the power supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3.
BCD (2 digit/byte) Binary Binary Binary
See 9-7 "Special register". Initial sequence program execution time in program-1 (ms) Maximum scan time in sequence program of program-1 (ms)
Binary
Minimum scan time in sequence program of program-1
Binary
Updated scan time in sequence program of program-1
Binary
Initial sequence execution time in program-2 (ms) Maximum scan time in sequence program of program-2 (ms) Minimum scan time in sequence program of program-2 (ms)
Binary
Updated scan time in sequence program of program-2 (ms)
Binary
7-35
Binary
Binary Binary
Page 155
Address
Name
S0C8 S0C9 S0CA
PRG.3
S0E0 S0E1 S0E2 S0E3 S0E4 S0E5 S0E6 S0E7 S0E8 S0E9 S0EA S0EB S0EC S0ED S0EE S0EF S0F0 S0F1 S0F2 S0F3 S0F4 S0F5 S0F6 S0F7 S0F8 S0F9 S0FA S0FB S0FC S0FD S0FE S0FF
S130
Initial scan time SCAN TIME max value SCAN TIME min
Maximum scan time in sequence program of program-3
(ms)
Binary
Minimum scan time in sequence program of program-3
(ms)
Binary
SCAN TIME Present value
Updated scan time in sequence program of program-3
(ms)
Binary value
S0CB
Initial sequence execution time in program-3 (ms)
Binary
Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 1 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 2 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 3 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 4 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 5 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 6 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Changed portion Program Ti m e ( M i n u t e · s e c ) Present time of the built-in clock is stored. change history 7 T i m e ( D a y · H o u r ) For data display, 2 digits are represented by 1Byte in BCD code. Time (Year · mo nt h) (Ex. "1234" represents "12 (min).34(sec).)
Changed portion
Program change Ti m e ( M i n u t e · s e c ) history 8 T i m e ( D a y · H o u r ) Time (Year · mo nt h)
TOYOPUC -PCS
Communication status data S131 S132 S133
Description
Flaming error
Parity error Overrun error
Bit B:PRG.3 parameter
Bit A: PRG.2, Bit 9 : PRG.1
,Bit 8:
Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).)
bit0:communicating bit1:RUN signal bit2:ERR0 signal bit3:ERR1 signal bit4:ALM signal bit8:link command usable bit9:link command error Flaming error counter Parity error counter Over run error counter
7-36
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Page 156
Address S140
Name
Description
~
G-S input data link area
S14F S150 ~
G-S output data link area
S15F S200 ~ S24F S250 ~ S2CF S2D1 S300
Error information
See 5-4 "Special register for error information output. "
PRG.1 Annunciator information
See Programming Manual.
CPU Version
CPU Version is stored.
Prg1-Link1
~
~
S3FF
Prg1-Link8
Communication (link) module status information
See the individual instruction manual for each communication(link) module.
(1-2) Data memory separate mode PRG.2 Address
Name
S004
Time (Sec)
S005
Time (Minutes)
S006
Time (Hours)
S007
Time (Day)
S008
Time (Month)
S009
Time (Year)
S00A
Day of week
S019 S01A S01B
Time (Minute·sec) Time (Day·Hour) Time (Year·month)
S022
1 ms timer
S023
10 ms timer
S024
100 ms timer
Description Present time of the built-in clock is stored. For data display, 1 digit is displayed by 1Byte in BCD code. (Ex. "0102" represents "12".) Year data is displayed with lower two digits of AD year. "day of week" data is represented by 0 ~ 6, which correspond to Sun. ~ Sat. BCD Note) Even if the register is rewritten directly, t i m e (1 digit/byte) change is impossible.Please perform a setup of time from <Setup data/time> of Pcwin or use an exclusive use of an application instruction. (Please refer to "309 SYS Clock adjustment instruction(FUN300) PC3J series since version 2.6" in "PROGRAMMING MANUAL" about an application instruction. ) Present time of the built-in clock is stored. For data display, BCD 2 digits are represented by 1Byte in BCD code. (2 digit/byte) (Ex. "1234" represents "12 (min).34(sec).) This timer works by 1 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 10 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 100 ms as 0 seconds when the power supply is turned on. Note) This special register can be Binary used 3JG series/3J series since Ver3.3.
S0A8 ~ S0AF S250 ~ S2CF S300
See 9-7 "Special register".
PRG.2 Annunciator information
See Programming Manual.
Prg2-Link1 Communication (link) module status Prg2-Link8 information
See the individual instruction manual for each communication(link) module.
~
~ S3FF
Link module corde
7-37
Page 157
(1-3) Data memory separate mode PRG.3 Address
Name
S004
Time (Sec)
S005
Time (Minutes)
S006
Time (Hours)
S007
Time (Day)
S008
Time (Month)
S009
Time (Year)
S00A
Day of week
S019 S01A S01B
Time (Minute·sec) Time (Day·Hour) Time (Year·month)
S022
1 ms timer
S023
10 ms timer
S024
100 ms timer
Description Present time of the built-in clock is stored. For data display, 1 digit is displayed by 1Byte in BCD code. (Ex. "0102" represents "12".) Year data is displayed with lower two digits of AD year. "day of week" data is represented by 0 ~ 6, which correspond to Sun. ~ Sat. BCD Note) Even if the register is rewritten directly, t i m e (1 digit/byte) change is impossible.Please perform a setup of time from <Setup data/time> of Pcwin or use an exclusive use of an application instruction. (Please refer to "309 SYS Clock adjustment instruction(FUN300) PC3J series since version 2.6" in "PROGRAMMING MANUAL" about an application instruction. ) Present time of the built-in clock is stored. For data display, BCD 2 digits are represented by 1Byte in BCD code. (2 digit/byte) (Ex. "1234" represents "12 (min).34(sec).) This timer works by 1 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 10 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 100 ms as 0 seconds when the power supply is turned on. Note) This special register can be Binary used 3JG series/3J series since Ver3.3.
S0A8 ~ S0AF S250 ~ S2CF S300
See 9-7 "Special register".
PRG.3 Annunciator information
See Programming Manual.
Prg3-Link1 Communication (link) module status Prg3-Link8 information
See the individual instruction manual for each communication(link) module.
~
~ S3FF
Link module corde
7-38
Page 158
(2-1)Data memory single mode, Basic area Address
Name
Description
S001 S002 S003
SCAN TIME max value SCAN TIME min value SCAN TIME Present value
S004
Time (sec)
S005
Time (minutes)
S006
Time (Hours)
S007
Time (day)
S008
Time (Month)
S009
Time (year)
S00A
Day of week
Maximum scan time in sequence program (ms) Binary Minimum scan time in sequence program (ms) Binary Updated scan time in sequence program (ms) Binary Present time of the built-in clock is stored. For data display, 1 digit is displayed by 1Byte in BCD code. (Ex. "0102" represents "12".) Year data is displayed with lower two digits of AD year. "day of week" data is represented by 0 ~ 6, which correspond to Sun. ~ Sat. BCD Note) Even if the register is rewritten directly, time (1 digit/byte) change is impossible.Please perform a setup of time from <Setup data/time> of Pcwin or use an exclusive use of an application instruction. (Please refer to "309 SYS Clock adjustment instruction(FUN300) PC3J series since version 2.6" in "PROGRAMMING MANUAL" about an application instruction. ) Cumulative value of CPU module make (current feed) time Binary, ower (h) Binary, pper Binary, ower Cumulative value of sequence program run time (h) Binary, pper
S00C S00D S00E S00F
Integrated make time Integrated run time
S019 S01A S01B
End processing time max value End processing time Min value End processing time Present value Time (Minute·sec) Time (Day·Hour) Time (Year·month)
S022
1 ms timer
S023
10 ms timer
S024
100 ms timer
S010 S011 S012
S0A8 ~
Link module corde
S0AF S0C0 S0C1 S0C2
PRG.1
S0C3 S0C4 S0C5 S0C6
PRG.2
S0C7 S0C8 S0C9 S0CA S0CB
PRG.3
Initial scan time SCAN TIME max value SCAN TIME min value SCAN TIME Present value Initial scan time SCAN TIME max value SCAN TIME min value SCAN TIME Present value Initial scan time SCAN TIME max value SCAN TIME min value SCAN TIME Present value
Maximum end processing time in sequence program (ms)
Binary
Minimum end processing time in sequence program (ms)
Binary
Updated end processing time in sequence program (ms)
Binary
Present time of the built-in clock is stored. For data BCD display, 2 digits are represented by 1Byte in BCD code. (2 digit/byte) (Ex. "1234" represents "12 (min).34(sec).) This timer works by 1 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 10 ms as 0 seconds when the power Binary supply is turned on. Note) This special register can be used 3JG series/3J series since Ver3.3. This timer works by 100 ms as 0 seconds when the power supply is turned on. Note) This special register can be Binary used 3JG series/3J series since Ver3.3. See 9-7 "Special register". Initial sequence program execution time in program-1 (ms)
Binary
Maximum scan time in sequence program of program-1 (ms)
Binary
Minimum scan time in sequence program of program-1
Binary
Updated scan time in sequence program of program-1
Binary
Initial sequence execution time in program-2 (ms) Binary Maximum scan time in sequence program of program-2 Binary (ms) Minimum scan time in sequence program of program-2 Binary (ms) Updated scan time in sequence program of program-2
(ms)
Binary
Initial sequence execution time in program-3 (ms) Binary Maximum scan time in sequence program of program-3 Binary (ms) Minimum scan time in sequence program of program-3 Binary (ms) Updated scan time in sequence program of program-3
7-39
(ms)
Binary
Page 159
Address S0E0 S0E1 S0E2 S0E3 S0E4 S0E5 S0E6 S0E7 S0E8 S0E9 S0EA S0EB S0EC S0ED S0EE S0EF S0F0 S0F1 S0F2 S0F3 S0F4 S0F5 S0F6 S0F7 S0F8 S0F9 S0FA S0FB S0FC S0FD S0FE S0FF
S130
Name Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 1 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 2 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 3 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 4 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 5 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 6 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 7 Time (Year·month) Changed portion Program Time (Minute·sec) change Time (Day·Hour) history 8 Time (Year·month)
TOYOPUC -PCS
Communication status data S131 S132 S133
Flaming error
Parity error Overrun error
Description Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).) Bit B:PRG.3 Bit A: PRG.2, Bit 9 : PRG.1 ,Bit 8: parameter Present time of the built-in clock is stored. For data display, 2 digits are represented by 1Byte in BCD code. (Ex. "1234" represents "12 (min).34(sec).)
bit0:communicating bit1:RUN signal bit2:ERR0 signal bit3:ERR1 signal bit4:ALM signal bit8:link command usable bit9:link command error Flaming error counter Parity error counter Over run error counter
7-40
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)
Bit BCD
(2 digit/byte)