Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual

Manual · Toyopuc

Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual

Manual387 pagesPDF 16 MB

Operation manual for the TOYOPUC PC3JG-P-CPU (TIC-6088) and PC3JG-CPU (TIC-6125) programmable controllers and their I/O modules.

What this file really is

The old site listed this file as a manual for the Toyopuc HPC-LINK, OUT-15 and 2 more models. Filed as an OUT-15 user manual, this is the operation manual for the TOYOPUC PC3JG CPU modules, which includes the I/O and output module specifications.

Download the PDF16 MB

Names · 2 models

The models it names

Filed with · 2 models

Also filed with these models on the old site

Summary

What is in it

The JTEKT operation manual for the TOYOPUC PC3JG CPU modules (PC3JG-P-CPU TIC-6088 and PC3JG-CPU TIC-6125). It covers system components, installation and wiring, initial CPU setting, test run, error alarms and troubleshooting, battery and fuse maintenance, and full specifications for the CPU, I/O, output modules such as the OUT-15, power and selector modules. Later chapters explain the link functions, the built-in computer link, PC Link and DLNK-M2, message display, SFC programming and dimensional drawings.

Its parts

  1. System Components
  2. Installation and Wiring
  3. Initial Setting
  4. Test Run
  5. Error Alarm
  6. Maintenance
  7. Specifications
  8. Link Function
  9. Built-in Function
  10. Message Display
  11. SFC Programming (Sequential Function Chart)
  12. Tool

From the manual

Key facts from this manual

Each line names its page in the PDF.

The operation manual (15th edition, November 2008) for the TOYOPUC PC3JG-P-CPU (TIC-6088) and PC3JG-CPU (TIC-6125) programmable controller. Its specification chapter also covers the system's modules, including the OUT-15 and OUT-18 DC output modules, the THU-2765 selector module and the power modules; the HPC-LINK appears only in the table of components. It explains installation, setup, error codes, battery and fuse maintenance and the module specifications.

Read for this summary: pages 1 to 3, 11, 14 to 15, 61 to 63, 115 to 116, 120 to 121, 194 to 197, 200 to 202, 205, 207 to 208, 382 and 385 to 386 of 387.

Module type
16-point DC output, (-) common: OUT-15 MOS-FET (THK-2790), OUT-18 transistor (THK-2753) p. 14
Commons
8 points per common, insulated between commons p. 194, 196
Isolation
Photo coupler insulation p. 194
Off-state leakage
0.1mA max p. 194
Terminal block
Detachable, held by top and bottom lock levers p. 200
Ambient temperature
0 to 55 C (common to each module) p. 120
OUT-15 rating
Rated DC5/12/24V (4.75 to 30V), 1A per point, 4A per common; on 2ms, off 6ms max p. 194
OUT-18 rating
Rated DC12/24V (10 to 30V), 0.5A per point, 2A per common; on and off 1ms max p. 196
Internal current (5V)
OUT-15 310mA, OUT-18 136mA, all points on p. 194, 196
Fuses
OUT-15 6.3A per common; OUT-18 3.2A per common, soldered and not replaceable p. 194, 196, 202
Fuse-blown detection
OUT-15 lights its ALM LED and can stop the CPU (error code 43); OUT-18 has none p. 202
THU-2765 selector
Sets rack No. and head I/O address of an added base; 31mA, 35 x 130 x 110 mm, 0.16kg p. 207
PC3JG CPU
TIC-6088: 180K word memory, 32 inputs and 32 outputs built in p. 14
Power modules
POWER1 THV-2747 AC85 to 264V in; POWER2 THV-2748 DC24V in; both DC5V 4A out p. 14

What this manual walks you through

  • Finding module part numbers in the system components table p. 14, 15
  • Removing and refitting an I/O terminal block p. 200, 201
  • Choosing whether a blown output fuse stops the CPU p. 202
  • Setting the rack number and I/O address on the selector module p. 208
  • Replacing the CPU battery p. 115, 116
  • Understanding error ranks p. 61
  • Reading the E/A lamp and the error code table p. 62, 63
  • Adding up module current consumption p. 382
  • Rush current on OUT-15 and OUT-16 outputs p. 385
  • General specifications for every module p. 120

Good to know

  • On the OUT-15 and OUT-16, rush current can flow for 1 to 2 ms when 24V is suddenly applied to the load, even with the output off. p. 385
  • The manual states that this rush current is not enough to turn on ordinary valves (solenoids). p. 385
  • On the OUT-15, the 2A rating for two points needs both points switched on and off together. p. 194
  • The OUT-18 fuse only protects the circuit board from burning, not the output elements. p. 196
  • On the selector module, rack No. F or a duplicated rack No. causes an error. p. 208

Questions this manual answers

What is the maximum load current of the TOYOPUC OUT-15?

1A per point, or 2A across two points switched together, with 4A per common. p. 194

Can the fuse on a TOYOPUC OUT-18 be replaced?

No. The OUT-18 fuse is soldered to the board and cannot be replaced. p. 202

What is the TOYOPUC THU-2765 used for?

It is the selector module used on an additional base, to set that rack's number and head I/O address. p. 207

What battery does the TOYOPUC PC3JG CPU use?

The TIP-5426 lithium rechargeable battery; the manual gives about 5 years as a replacement guideline. p. 115

What error code does a blown OUT-15 fuse cause?

With the error setup jumper on, the CPU stops RUN with error code 43; with it off, RUN continues and only the ALM LED lights. p. 202

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. FOREWORD3
  2. FOR SAFETY OPERATION4
  3. REVISION HISTORY OF OPERATION MANUAL6
  4. Composition of Related Operation Manuals7
  5. 1. SYSTEM COMPONENTS11
    1. 1.1 Features11
    2. 1.2 System connection12
    3. 1.3 Table of System Components14
    4. 1.4 Name and function of each panel switch and each lamp17
  6. 2. Installation and wiring21
    1. 2.1 Environment for installation21
    2. 2.2 Cautions in installing22
    3. 2.3 Actual mounting of each module23
    4. 2.4 Wiring24
  7. 3. Initial Setting34
    1. 3.1 CPU setting before shipping34
    2. 3.2 CPU Setting Procedure42
  8. 4. Test Run60
    1. 4.1 Check Items before test run60
  9. 5. Error Alarm61
    1. 5.1 Error ranks61
    2. 5.2 Display of abnormality62
    3. 5.3 LAYED ERRORS TABLE63
    4. 5.4 Special Register for Error Information Output66
    5. 5.5Error-related Information67
    6. 5.6 Error message70
    7. 5.7 Counteraction against CPU error72
  10. 6. Maintenance115
    1. 6.1 Battery Replacement115
    2. 6.2 fuse replacement119
  11. 7. SPECIFICATIONS120
    1. 7.1 General specification120
    2. 7.2 CPU module specification121
    3. 7.3 Link specification176
    4. 7.4 I/O Specification179
    5. 7.5 I/O module specification185
    6. 7.6 Base Specification203
    7. 7.7 Power Module Specification205
    8. 7.8 Selector Module Specification207
44 more lines, from page 210 on
  1. 7.9 I/O Cable Specification210
    1. 7.10 I/O Branch Module Specification210
    2. 7.11 I/O Conversion Cable Specification210
    3. 7.12 Selector base specification211
  2. 8. Link function215
    1. 8.1 Link parameter setting215
    2. 8.2 Data link area216
    3. 8.3 Commands218
    4. 8.4 Special Relays and Special Registers221
  3. 9. Built-in function226
    1. 9.1 Built-in computer link227
    2. 9.2 Built-in PC Link263
    3. 9.3 Built-in DLNK-M2287
    4. 9.4 SN-I/F333
    5. 9.5 Set built-in link parameter335
    6. 9.6 Special register358
  4. 10. Message display360
    1. 10.1 Monitor operating state360
    2. 10.2 Error code monitor361
    3. 10.3 I/O monitor361
    4. 10.4 Monitor link communication state.362
    5. 10.5 Library information364
  5. 11. SFC Programming(Sequential Function Chart)368
    1. 11.1 Indication of SFC.368
    2. 11.2 Indication of FB.368
    3. 11.3 Restriction of SFC369
  6. 12. Tool371
    1. 12.1 I/O operation panel371
    2. 12.2 I/O Check (for Output)372
  7. Appendix 1. Dimensional outline drawing373
    1. Appendix 1-1 PC3JG373
    2. Appendix 1-2 Power module374
    3. Appendix 1-3 Selector module375
    4. Appendix 1-4 I/O module376
    5. Appendix1-5 Base377
    6. Appendix1-6 Selector Base378
    7. Appendix1-7 Installation dimension379
  8. Appendix 2. Others380
    1. Appendix 2-1 Module type discriminating codes380
    2. Appendix 2-2 Individual current consumption of each module382
    3. Appendix 2-3 Error in self-contained clock383
    4. Appendix 2-4 Hexadecimal system384
    5. Appendix 2-5 Precautions in use of output modules OUT-15 an385
  9. T-31115E387

From the PDF’s own bookmarks.

The whole text · 44 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. FOREWORD1-3
  2. Pages 4 to 64-6
  3. Pages 7 to 107-10
  4. 1. SYSTEM COMPONENTS11-20
  5. 2. Installation and wiring21-33
  6. 3. Initial Setting, pages 34 to 4234-42
  7. 3. Initial Setting, pages 43 to 5143-51
  8. 3. Initial Setting, pages 52 to 5952-59
  9. Pages 60 to 6960-69
  10. Pages 70 to 7970-79
  11. Pages 80 to 8980-89
  12. Pages 90 to 9990-99
  13. Pages 100 to 109100-109
  14. Pages 110 to 114110-114
  15. 6. Maintenance115-119
  16. 7. SPECIFICATIONS, pages 120 to 129120-129
  17. 7. SPECIFICATIONS, pages 130 to 139130-139
  18. 7. SPECIFICATIONS, pages 140 to 149140-149
  19. 7. SPECIFICATIONS, pages 150 to 159150-159
  20. 7. SPECIFICATIONS, pages 160 to 169160-169
  21. 7. SPECIFICATIONS, pages 170 to 179170-179
  22. 7. SPECIFICATIONS, pages 180 to 189180-189
  23. 7. SPECIFICATIONS, pages 190 to 199190-199
  24. 7. SPECIFICATIONS, pages 200 to 209200-209
  25. 7. SPECIFICATIONS, pages 210 to 214210-214
  26. 8. Link function215-225
  27. 9. Built-in function, pages 226 to 235226-235
  28. 9. Built-in function, pages 236 to 245236-245
  29. 9. Built-in function, pages 246 to 255246-255
  30. 9. Built-in function, pages 256 to 265256-265
  31. 9. Built-in function, pages 266 to 275266-275
  32. 9. Built-in function, pages 276 to 285276-285
  33. 9. Built-in function, pages 286 to 295286-295
  34. 9. Built-in function, pages 296 to 305296-305
  35. 9. Built-in function, pages 306 to 315306-315
  36. 9. Built-in function, pages 316 to 325316-325
  37. 9. Built-in function, pages 326 to 335326-335
  38. 9. Built-in function, pages 336 to 345336-345
  39. 9. Built-in function, pages 346 to 355346-355
  40. 9. Built-in function, pages 356 to 359356-359
  41. 10. Message display360-367
  42. 11. SFC Programming(Sequential Function Chart)368-370
  43. Pages 371 to 379371-379
  44. Pages 380 to 387380-387

The file

Revision and size

Part no.T-311
Revisionrevision 15, 2008.11.07
PublisherJTEKT Corporation
Pages387
PDF16 MB
TextText from the PDF itself; pages 1, 373, 374, 375, 376 and 378 are scans, read by OCR, which may hold reading errors.
T-311

The first pages · 3 of 387

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 387
Page 2
Page 2of 387
Page 3
Page 3of 387