Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual: 3. Initial Setting, pages 43 to 51

Pages 43 to 51 of 387, from Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual

The original document is the PDF (16 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Toyopuc OUT-15 and Toyopuc OUT-18

Page 43

In addition to the above, as CPU operation mode parameter execution/non-execution of program-2,-3 and its link with RUN signal can be selected. Item Program execution

RUN signal link

*2

*1

Selection value Program1 Program2 Program3 Program1 Program2 Program3

Effective [EXECUTE] (fixed) Effective /ineffective ( Execute/non-execute) Effective /ineffective ( Execute/non-execute)

Link (fixed) Link /Non-link Link /Non-link

*1 Execution of Program-2 and-3 can be selected from the parameters. If "INEFFECTIVE" is selected, the applicable program (program-2 or -3) is not executed. *2 Link of program-2 and -3 with RUN signal is selected from the parameters. If "LINK" is selected and the applicable program stops, RUN signal turns OFF, linked with the program , then allowing stop of all the programs.

3-10

Page 44

3.2.2 Separate patterns of program data By presetting CPU operation mode, the PC3JG can select program capacity and data capacity as necessary. (1)Data area separate mode Separate pattern 1 PRG.1

PRG.2

PRG.3

Program 1 (16KW)

Program 2 (16KW)

Program 3 (16KW)

I/O Basic area data

Basic area data

Basic area data

Extended area data

Separate pattern 2 PRG.1

PRG.3

Program 1

Program 3 (16KW)

(32KW)

I/O Basic area data

Basic area data

Extended area data

3-11

Page 45

Separate pattern 3 PRG.1

PRG.2

Program 1 (16KW)

Program 2 (32KW)

I/O Basic area data

Basic area data

Extended area data

Separate pattern 4 PRG.1

PRG.2

Program 1 (16KW)

Program 2 (16KW)

I/O Basic area data

Basic area data

Extended area data

3-12

Page 46

Separate pattern 5 PRG.1

PRG.3

Program 1 (16KW)

Program 3 (16KW)

I/O Basic area data

Basic area data

Extended area data

PC3JG mode PRG.1

PRG.2

PRG.3

Program 1 (60KW)

Program 2 (60KW)

Program 3 (60KW)

*1

*1

I/O Basic area data

Basic area data

Basic area data

Extended area data Grand capacity I/O(GX/Y) Grand capacity extended area data(GM)

Grand capacity buffer data(EB)

*1 There is a limitation when the standard and user library is used since ver.2.00. Please refer to 「10.5 library information」 for details.

3-13

Page 47

(2)Data area single mode Single pattern 1 PRG.1

PRG.2

PRG.3

Program 1 (16KW)

Program 2 (16KW)

Program 3 (16KW)

I/O

Basic area data

Extended area data

Single pattern 2 PRG.1

PRG.3

Program 1

Program 3 (16KW)

(32KW)

I/O

Basic area data

Extended area data

3-14

Page 48

Single pattern 3 PRG.1

PRG.2

Program 1 (16KW)

Program 2 (32KW)

I/O

Basic area data

Extended area data

Single pattern 4 PRG.1

Program 1 (32KW)

I/O

Basic area data

Extended area data

3-15

Page 49

Single pattern 5 PRG.1

Program 1 (16KW)

I/O

Basic area data

Extended area data

Single pattern 6 PRG.1

PRG.2

Program 1 (16KW)

Program 2 (16KW)

I/O

Basic area data

Extended area data

3-16

Page 50

(2)PC2 compatible mode PRG.1

Program 1 (32KW)

I/O

Basic area data

3-17

Page 51

3.2.3 Program Execution The PC3JG can execute two or more programs, that is, three sequence programs maximum. In detail, these programs are executed in the order of program-1, program-2, program-3 and end processing. The number of programs and execution/ non-execution (*1) of program-2 and -3 are set up using the CPU operation mode parameters. Furthermore, link/non-link (*2) of program-2 and -3 with RUN signal is also set using the CPU operation mode parameters. *1 Execution of program-2 /-3 can be selected from the CPU operation mode parameters. If INEFFECTIVE(Non-execution) is selected, the applicable program (program-2 or 3) is not executed. *2 Link of program-2/-3 can be selected from the CPU operation mode parameters. If "LINK" is selected and the applicable program stops, RUN signal turns OFF linked with the program stop and all other programs stop simultaneously. (1) Program execution sequence Power ON or Reset/Start

Update I/O data 1st scan only*3 PRG.1

PRG.1

Initial 3 program*

PRG.1

Initial 3 program*

1st scan

CALL

3

Main program

Main program

END

END

END

*4

LABEL

*4

LABEL

*4

Subroutine program

Subroutine program

Subroutine program

RET

RET

RET

· ·

· ·

*4

START

· ·

*3

START

Main program

LABEL RET only* scan only*

3

START

Initial 3 program*

1st

PEND

PEND

PEND

Initial program is a sequence program being executed only once whenever the power switch is turned ON or RESET/START is pressed. :showing label No. of subroutine program. 128 subroutines of S000 ~ S127 per program and 1024 subroutines of EL0000~EL1023 commonly available for jump and subroutine can be created respectively.

3-18