Page 356
(6) Format of the transferred message relative word setting item data size data range address +00W Destination node address(MAC ID) 2 bytes 0000h - 003Fh +01W Service code 2 bytes 0000h - 00FFh +02W Class ID 2 bytes 0000h - FFFFh +03W Instance ID 2 bytes 0000h - FFFFh +04W Service data size 2 bytes 0000h - 0080h +05W Service data 0 – 128 bytes | +44W Destination node address (MAC ID): The destination node address (0 - 63) of the explicit message is set. Service code: The service code defined by DeviceNet is set. Class ID: The destination class ID of the explicit message is set. Instance ID: The destination instance ID of the explicit message is set. Service data size: The byte number of the service data is set. Service data: The data defined by the service code is set. Attribute ID: In case that the destination attribute ID of the explicit message is set, it is set to the top of the service data. (7) Format of the response data relative word setting item data size data range address +00W Completed flag of reception 2 bytes 0000h or 0001h +01W Destination node address(MAC ID) 2 bytes 0000h - 003Fh +02W Service Code 2 bytes 0000h - 00FFh +03W Reserved 2 bytes indetermination +04W Reserved 2 bytes indetermination +05W Service data size 2 bytes 0000h - 0080h +06W | Service data 0 – 128 bytes +45W Completed flag of reception: The flag is shown the reception completion of the receiving data. 0000h: not completed, 0001h: completed Service Code: In case of the normal response, the data that the MSB of the service code specified by the command is set is saved. (ex: service code 10h -> response code
90h)
In case of the error response, 94h is saved. Service data: The data defined by the service code is set. In case of the error response, the error code (2 bytes) is saved. So, the service data area must have 2 bytes or more area. Reserved: For extending in the future Note) The area saved the response data must clear (set 00h) at the initial stage.
9-131
Page 357
(8) Usage of MSET command Example for usage OP1 ---- Link program No. = 1, Link No. = 3, Data size of transferred message = 16 bytes OP2 ---- Top address of register area saved transferred message = D0L OP3 ---- Top address of register area saved response data = D100L MSET
1310h
D0L
D100L
Condition for execution Usable flag for link command(V90,92,94,96,98,9A,9C,9E)
The usable flag for the link command is shown the response condition for the explicit message command. The address of the flag is determined by link No. Link NO. Address of flag
1
2
3
4
5
6
7
8
V90 V92 V94 V96 V98 V9A V9C V9E
Note) (1) This command can not be executed when CPU has stopped. (2) The condition for execution must be edge. (3) On the same condition, the number of the executable MSET commands is MAX 15. In case of 16 or more, the function error is occurred.
9-132
Page 358
9.6. Special register The register associated with the built-in link of PC3JG is as follows. Address S0A8
Content
Remarks
Link1
~
~
S0AF S0B0
Link8 (Link2-1)
~
~
S0B7 S0B8
(Link2-8) (Link3-1)
Link module code (data single mode)
Specially designed for PC3JG
Link module code (data single mode))
Specially designed for PC3JG
The state of communication of the child station (during communication =1)
PC link PC3JG DLNK-M2
~
Specially designed for PC3JG
~
Link module code
S0BF
(Link3-8)
S3#0 S3#1 S3#2 S3#3 S3#4 S3#5
Slave 1~15 Slave 16~31 Slave 32~47 Slave 48~63
DLNK Master status area
DLNK-M2
S3#C S3#D S3#E S3#F S3*0
Slave 1~15 Slave 16~31 Slave 32~47 Slave 48~63
PC link PC3JG DLNK-M2 PC3JG
The state of connection of the child station (existence of connection
Register for rink error information output S3*B S3*C Slave 1~15 Specify separation of the child PC link Slave16~31 S3*D station (separation=1) DLNK-M2 Slave32~47 S3*E Slave48~63 S3*F Note. PC3JG PC3JG built-in link is exclusively applied. The above address is determined by link Number. In the data separate mode, "link No. in each program", "#" and "*" correspond as follows. Link No. 1 2 3 4 5 6 7 8 # 0 2 4 6 8 A C E * 1 3 5 7 9 B D F In the data single mode, the "link 2-1 to 2-8" and "3-1 to 3-8" correspond as follows. Address ES000
Name Link2-1
~
~
ES0FF ES100
Link2-8 Link3-1
~
~
ES1FF
Link3-8 correspondence
Communication(Link) Module Status info. Communication(Link) Module Status info.
9-133
Correspondence toS300~S3FF
Correspondence toS300~S3FF
Page 359
Link module code list module name code
PC link master
0102
PC1-I/F output
0102
PC link slave
0002
PC1-I/F input
0002
Computer link
0003
ME-NET master
0104
ME-NET slave
0004
SIO module
0005
Memory card I/F
0005
High speed remote I/O
0008
AS-I
0008
HPC link master
4009
SUB-CPU master
4009
HPC link slave
**09
SUB-CPU slave
**09
2-port M-NET
0002
Pulse output module
0100
DLNK-M
8008
DLNK-S2
8008
DLNK-M2
8208
Ethernet
8203
AF1K
800E
MA1K
810E
Motion controller
820E
FL-net(8KB)
8009
FL-net(16KB)
8109
FL-net(32KB)
8209
PROFI-S2
8309
9-134
** : Slave number ** : Slave number