Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 43 of 44

Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual, pages 371 to 379

Pages 371 to 379 of 387: 12. Tool; Appendix 1. Dimensional outline drawing

The original document is the PDF (16 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Toyopuc OUT-15 and Toyopuc OUT-18

Page 371

12.

Tool Tools are as follow. I/O operation panel I/O check (for output) In case of using this function, Pcwin Ver5.1 or later must be used. Refer to “PCwin” about explaining in full.

12.1.

I/O operation panel This function is the debug support function that enables I/O operation when actual input device is not connected. Input from this I/O operation panel ignores the input from sequence program and forcibly turns I/O ON/OFF. (Note) Forced output of the output in the I/O operation panel function cannot be carried out. About difference from [Forced ON/OFF of I/O] • Forced ON/OFF of I/O :There is forced setting of I/O but thereafter, it is the actual input state. • I/O Operation Panel (Input Retention) : Retains I/O state even after I/O operation setting. (Only PC3JG is valid) Setting type • Hold

: Holds input state from I/O operation panel. (Actual input of the sequence program is ignored) (PC3JG)

• 1 Shot

: Carries out forced setting only once. After execution, input of actual sequence program becomes valid. (This function is similar to [I/O Forced ON/OFF]

PC3JG PWR RUN MODE E/A

X00 Y01

1

S 0123456789ABCDE F

X02 Y03 displayed while executing this function

INC

12

12-1

Page 372

12.2.

I/O Check (for Output) This function is meant for output wiring check at the time of equipment start up. Output based on

I/O check function forcibly turns I/O ON/OFF ignoring the output of sequence program. Kindly avoid using the equipment under operation and also take sufficient care for safety. (Note) Forced output of input cannot be carried out in the I/O check function.

Automatic Stoppage Timer This timer is meant for stopping the present function automatically on the PC3JG side, in case communication between Pcwin and PC3JG breaks, for the safety of the system. It can be set in the range of 2~300 sec. Kindly carry out setting on the I/O operation panel.

PC3JG PWR RUN MODE E/A INC

X00 Y01

1

S 0123456789ABCDEF

X02 Y03 displayed while executing this function

12-2

Page 373 read from a scan by OCR; it may hold reading errors

Appendix 1. Dimensional outline drawing Appendix 1-1 PC3JG

[ PC3UG ] A

130 is) 118 P 0 > |.

Appendix1

Appendix -1

Page 374 read from a scan by OCR; it may hold reading errors

Appendix1-2 Power module

=| 110 35 105 (“POWER 1 | ] J

INPUT ACBB~264Y TC ik

130, | li TERM.

Appendix1-2

Page 375 read from a scan by OCR; it may hold reading errors

Appendix 1-3. Selector module, - - 110 35 105 POWER | | ERR i {sw UU UU “ rH | “Ly L qaonqonon H UUUUUUU i

Appendix1-3

Page 376 read from a scan by OCR; it may hold reading errors

I/O module

Appendix 1-4, - | 7 y Oet ee eee ST TOOOOOOO@ah a “s 3° OO Oe GOO OC = spf TUPTTST Terr sir ard

Appendix1-4

Page 377

Appendix1-5

Base

(1) 8Slot Base

(2) 8Slot Base(2)

(3) 6Slot Base

(4) 4Slot Base

(5) 2Slot Base

Appendix1-5

Page 378 read from a scan by OCR; it may hold reading errors

Appendix1-6 Selector Base

(1) 8Slot Selector Base

|, -4 ny ee an: eb (2) 6Slot Selector Base

160

Appendix1-6

Page 379

Appendix1-7

Installation dimension

(1) 8Slot Base

(2) 8Slot Base(2)

(3) 6Slot Base

(4) 4Slot Base

(5) 2Slot Base

Appendix1-7