The text of a manual · part 42 of 44
Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual: 11. SFC Programming(Sequential Function Chart)
Pages 368 to 370 of 387, from Programmable Controller TOYOPUC PC3JG-P-CPU TIC-6088 / PC3JG-CPU TIC-6125 Operation Manual
The original document is the PDF (16 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Toyopuc OUT-15 and Toyopuc OUT-18
Page 368
11.
SFC Programming(Sequential Function Chart) FB Programming(Function Block) SFC is a graphical programming language like a flow chart specified in “IEC61131-3“ A specially designed programming soft ware “PCwin” is necessary for programming by SFC or FB. Refer to “Instruction manual for SFC introduction” and “PC win” about programming by SFC. Refer to “PCwin” about programming by FB.
11.1.
Indication of SFC.
When SFC program is stored, “SFC” is indicated in the display.
PC3JG PWR RUN MODE E/A
X00 Y01
The existence of Program of SFC
1
S 0123456789ABCDEF
X02 Y03
Program I is being programmed by SFC.
INC
Display SFC 1 → s1 ,
11.2.
2 → s2 ,
3 → s3
Indication of FB.
When FB program is stored, “FB” is indicated in the display.
X00
PWR RUN MODE E/A INC
Y01
PC3JG
1
S 0123456789ABCDEF
X02 Y03
The function blocks are used.
11
11-1
Page 369
11.3.
Restriction of SFC
When carrying out Programming based on SFC, Data memory area indicated below is selected exclusively for execution control of SFC. Therefore, be careful that it can not be used as user memory. Further, note that sometimes programming based on SFC is not possible depending on the operation mode. Since “V58 – V5D”and “EV 800 – EVBFF” of special relay are also occupied for SFC execution control, do not access this area.
Data area
Program No.
PC3JG
P1
Separate
P2
Mode
P3
Separate mode1
Separate mode2
Separate mode3
Separate mode4
Separate mode5
Single
Steps
*1 mode2
Action
SUB-
Step
Labels
SFCs
1000
16
1000
256
100
P1-R580~R7FF
1000
16
1000
256
100
P2-R580~R7FF
1000
16
1000
256
100
P3-R580~R7FF mode3
Single mode4
Single mode5
Single mode6
H000~H5FF
EN000~EN5FF
*2
*2
*2
1000
16
1000
256
100
P1-R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
500
1000
16
1000
256
100
P2-R580~R7FF
ET200~ET3FF
H200~H3FF
EN200~EN3FF
P3
500
1000
16
1000
256
100
P3-R580~R7FF
ET400~ET5FF
H400~H5FF
EN400~EN5FF
P1
1000
1000
16
1000
256
100
P1-R580~R7FF
ET000~ET3FF
H000~H3FF
EN000~EN3FF
P2
---
---
---
---
---
P3
500
1000
16
1000
256
100
P1
500
1000
16
1000
256
100
P1-R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
P2
1000
1000
16
1000
256
100
P2-R580~R7FF
ET200~ET5FF
H200~H5FF
EN200~EN5FF
P3
---
---
---
---
---
---
---
---
---
P1
500
1000
16
1000
256
100
P1-R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
P2
500
1000
16
1000
256
100
P2-R580~R7FF
ET200~ET3FF
H200~H3FF
EN200~EN3FF
P3
---
---
---
---
---
---
---
---
---
P1
500
1000
1000
256
100
P1-R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
P2
---
---
---
---
---
---
---
---
---
---
---
--16 ---
---
---
---
---
P3-R580~R7FF
ET400~ET5FF
H400~H5FF
EN400~EN5FF
P3
500
1000
16
1000
256
100
P3-R580~R7FF
ET400~ET5FF
H400~H5FF
EN400~EN5FF
P1
500
1000
16
1000
256
100
R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
P2
Imposible
Imposible
P3
Imposible
Imposible
P1
1000
1000
P2
---
---
P1
500
16 ---
1000
256
100
---
---
---
P3
---
R580~R7FF
ET000~ET3FF
H000~H3FF
EN000~EN3FF
---
---
---
---
H000~H1FF
EN000~EN1FF
Imposible 1000
16
1000
P2
256
Imposible 100
R580~R7FF
ET000~ET1FF
Imposible ---
---
--16
---
Imposible ---
---
---
---
--EN000~EN3FF
P1
1000
1000
1000
256
100
R580~R7FF
ET000~ET3FF
H000~H3FF
P2
---
---
---
---
---
---
---
---
---
---
P3
---
---
---
---
---
---
---
---
---
---
P1
500
1000
1000
256
100
R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
16
P2
---
---
---
---
---
---
---
---
---
---
P3
---
---
---
---
---
---
---
---
---
---
P1
500
256
100
R580~R7FF
ET000~ET1FF
H000~H1FF
EN000~EN1FF
1000
16
1000
P2 P3
---
PC2
Usable
ET000~ET5FF
500
Imposible ---
---
---
P1 interchange number
The data memory occupation area
P2
P3 Single
Processes
P1 mode1
Single
Actions/
Transitions
---
0000 -9999
---
Imposible ---
Imposible 0000 -9999
---
000-
000-
999
255
00-99
---
---
---
---
---
---
---
---
---
---
---
---
*1 The number of steps for which each program number can be used is shown (PC3JG Separate mode). Example P1+P2+P3 ≤ 1500 P1 P2 P3 Explanation P1+P2 ≤ 1000 At 700 step use of P1. 700 300 500 P3 can use 500 steps.P2 is 300(1000-700) step. P2+P3 ≤ 1000 P3 ≤ 500 400 step use of P1. P2 is 600(1000-400) step. 400 600 400 At P3 can use 400(1000-600) step. *2 The use area in the ET/H/EN address is decided depending on the number of use steps of each program.
11-2
Page 370
(1) They cannot be used in PC2 compatible mode/PC2/PC1 series•MX. (2) In case of single mode, it can be used only in Program 1. (3) When Program capacity is 16 KW, step number is restricted to maximum 500. (4) Identifier R (Link Register Area) and Extension Timer Area of User Data Memory are for SFC control. (5) Extension label (EL****) is for SFC. Note) Extension Timer and Counter and Extension Label reserved for SFC can not be used. Co-existence of SFC and usual LD (Ladder) is possible. Even when using SFC, no special setting is required. When programming is carried out with SFC, always carry out Editing and Monitoring with “PC Win”. Never carry out editing with peripheral devices like Hellowin, GH3 etc. which corresponds only with LD.
11-3