Page 4

FOR SAFETY OPERATION Before installing, operating, maintaining and checking, read carefully this Manual without fail for proper and safety operation and work. Any operator and any maintenance man who relate to this product (Programmable Controller) are requested to acquire the knowledge on devices, safety information and cautions before being engaged in the operation and maintenance. This Manual classifies the safety caution level into "WARNING" and "CAUTION" using alert symbols as follows.

Failure to observe the instructions given in this Manual could result in death or bodily injury of the operator. Failure to observe the instructions given in this Manual could result in risk of bodily injury or physical damage to equipment, etc.

Don't overhaul the module and don't touch the module internals, with the power switch kept ON. Failure to observe this instruction could result in electric shock. Don't touch the terminals with the power switch kept ON. Failure to observe this instruction could result in electric shock. Execute write during PC run (write during run) only when cyclic operation of main equipment/machine is in shutdown. Failure to observe this instruction could result in breakdown of its device(s) and bodily injury from mis-operation, if any. In handling the lithium battery, read and observe " Lithium Battery Handling Cautions " given in this Manual. Improper handling would cause liquid leak, overheat, sparking, and fracture, which could then result in breakdown of units and devices and bodily injury.

ii

Page 5

Regarding safe-related signals and emergency stop circuit, etc., handle those signals in external units without through this system.

Use this product under an environment which meets the environmental general specification specified in this Manual. Don't attach/detach each module to/from its base, with the power switch kept ON. Don't touch directly the electronic circuits inside the module. Failure to observe this instruction could result in breakdown of the module by static electricity. The cautions on storage and transportation 1.Since the memory part is in voltaic state by the internal battery when, as for this module, an external power supply is not supplied please keep it according to " 7.1 General specification." However, Ambient temperature is -20 - +60 °C. Moreover, please do not place this module directly on the thing with conductivity. 2.Please remove a battery, when you cannot keep this module for a long period of time (three months or more) or you cannot perform storage according to "7.1 General specification." The ambient temperature in this case is -25 - +70°C. Moreover, since an electric device is weak to dew condensation, please avoid dew condensation using a desiccant etc.

iii

Page 6

REVISION HISTORY OF OPERATION MANUAL Operation manual revision No. is added as a part of Manual No. described on the cover sheet of the manual. Operation Manual No.

T–311

#

E N: Japanese

E: English

Series No. Revision symbol Revision No.

Date of Revision

2

2003.06.02

3

2003.08.26

4

2003.09.15

5

2004.01.14

6

2005.01.10

7

2005.10.16

8

2006.01.01

9

2006.04.01

10

2006.06.01

11

2006.08.01

12

2006.10.04

13

2007.09.05

14

2007.10.05

Correct missing description.

15

2008.11.07

The explanation is added for directive 2006/66/EC

Revision Details

7.4.3. Specification of Output (correction of chart for PC3JGP) 5.Error Alarm (correction of error contents) 7.2.2. User memory data (correction of I/O points) 7.2.5. Table of special relays 7.2.6. Table of special registers 2. Installation and wiring (correction of installation and wiring) 7.5. I/O module specification (addition of notes) Explanation of Programmer is unified to PCwin. The connection path function is added to Link parameter setup of DLNK-M2. Mark review of output module specification. Note addition to power supply module specification. The cautions on storage and transportation are added. The cautions about installation environment are added. The cautions about wiring for 5V cable are added. DLNK-M2 error-code explanation addition A special register and I/O Address part correction System configuration apparatus list reexamination The company name "TOYODA MACHINE WORKS,LTD" is changed to "JTEKT CORPORATION" Recommended change of communications cable, ferrules, crimping tool. Explanation change in error code D6 (collation error). The connection path setup is added to the link parameter. Addition of standard and user library function explanation. Addition of explanation at high-speed communication. Addition of the USB I/F cable to the composition equipment list. Display correction of OUT-11’s blown fuse Addition to limitations when standard and user library is used. Notes when the link parameter is set are added. The size of the screw of the connector is added. PCwin of "Table of System Components" is corrected. "Restriction of SFC" is corrected. Correct missing description. Review of "Table of System Components" "RUN relay" explanation correction Correction of “Connector pins configuration” of OUT-28D and OUT-29D iv