The text of a manual · part 1 of 7
TOYOPUC Programmable Controller Line Up, pages 1 to 10
Pages 1 to 10 of 64
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Toyopuc THK-2750
Page 1
TOYODA
TOYOPUC Programmable Controller | '"® UP
JTEKT JTEKT
JTEKT CORPORATION Koyo
Page 2
Just fitting with the needs of customer "Further expanding TOYOPUC series in FA solution"
PC3J series
Direct circuit monitor
PCwin/PCwin-Safe2
Safety PLC
Page 3
CONTENTS Line up
……………………………………
3
Network configuration …… 5 drawing
TOYOPUC-PC10/PC3J TOYOPUC-PC10 series
…………
TOYOPUC-PC3JX series
………… 11
7
Input/Output module ………………… 13 Communication module ……………… 15 Special module
………………………… 19
Configuration ……………………………… 23
PC10 series
Board type PLC TOYOPUC-Plus
……………………… 25
Compact PLC TOYOPUC-PCDL ………………………… 27 TOYOPUC-PCk
Board type PLC
………………………… 28
Specifications Performance specifications ……… 29 External dimensions
………………… 31
Software PCwin
…………………………………… 33
Direct circuit monitor
…… 39
General purpose ………………… 43 operation panel
Compact PLC
Safety PLC What is safety ?
……………………… 45
TOYOPUC-PCS
……………………… 47
TOYOPUC-PCS-J
…………………… 49
TOYOPUC-Plus Safety ……………… 51 General specification ・ ……………… 53 External dimensions
Motion controller MCML
…………………………………… 55
MCSSC
Device list ……………………………… 57
2
Page 4
Lineup
Factory management and from a line machine control to a small-scale machine , TOYOPUC plays an active part in all the stages. Memory capacity
Large capacity
PC3J series
Board type PLC
Plus
Compact PLC PCDL PCk06 PCk05
3
Conveyer machines control
Assembling line
Page 5
TOYOPUC-Line up will match every facility scale 1. facility, high performance, and high speed processing
PC10 series application :PC10 series 2. Middle-scale facility :PC3J series 3. manual equipment to full automatic equipment: Board type PLC Plus
PC10G
4. Small-scale/Simple facility :Compact PLC PCDL, PCk05, PCk06
Supporting flexible applications.
PC10P
1. from memory 2K words ~ 180K words and I/O 14 points ~2048 points.
PC3JX
PC3JX-D
2. 3 programs can be created independently. (PC10, PC3J series)
Abundant functions 1. test mode function, which can return to the original program instantly after modifications (PC10 series)
Machine tool
Line control
2. 3 languages comments can be installed in a PLC (PC10 series)
Facility memory capacity can realize Visualization 1. the program comment and SFC-FB information.
High-speed
Processing speed
(PC10, PC3J series, Plus) 2. I/O drawing, and realizes CAD-less (PC10 series). 4
Page 6
Network configuration drawing
From small-scale machine control to large-scale distributed control/centralized control in a plant, all hierarchy networks layer can be built flexibly.
Programming tool (PCwin) can be connected by a network. 1. All communication modules, such as FL-net*, Ethernet*, and HPC can be connectable 2. Remote programming up to four layers can be possible
Four layers
Remote programming
*FL-net is a controller level network (OPCN-2) which JEMA (Japan Electrical Manufacturers' Association) defined. *Ethernet is a registered trademark of Fuji Xerox.
5
Page 7
All network modules, which covers all hierarchies layers, are prepared. 1 . Each Layer is communized by FL-net and Ethernet* common use. 2 . FL remote and Ethernet* realize the best high speed device communication.
Ethern e t ※
Information system
FL-net HPC- L in k、PC- L in k
Et h e r Ne t /I P*
Facilities system
CC- L in k* SN- I /F Devic e Ne t*
Device system
EtherCAT*
FL- r e m o t e
Explanation of a FL-remote terminal with diagnostic functions Sensor/Actuator Short circuit detection Current of each I/O is monitored: Regarding input, detected as short circuited when input is 50 mA or more per point. Regarding output, detected as short circuited when over 500mA (500mA inclusive) flows per point. ● Wire-cutting detection
Current of each I/O is monitored: regarding input, detected as disconnected when input is 0.3 mA or less per point. Regarding output, detected as disconnected when output is at and less than 3mA.
Sensor/Actuator
Short circuit
Short circuit
Sensor/Actuator
Wire-cutting
Sensor/Actuator
Wire-cutting
● I/O power voltage monitoring
Whether I/O power is supplied to units or not is reported to a Master.
I/O power
I/O power I/O power
I/O power
*Ethernet is a registered trademark of Fuji Xerox. *EtherCAT is a registered trademark of Beckhoff Automation GmbH. *CC-Link is a registered trademark of Mitsubishi Electric Corporation. *DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc.
6
Page 8
TOYOPUC-PC10/PC3J
TOYOPUC-PC10 series The programmable controller who knows all about machines ■ The CPU function sticking to user-easy-operation ■ The large memory which realizes "Visualization"
■ Various communication functions
SFC* (Sequential Function Chart)programming is available. Process operation progress, which has been unclear in the conventional ladder circuit, "Visualization of process operation" can be performed and maintenance is easy.
Control circuit is described by a flowchart The progress of processes can be easily followed through the flowchart and colors. Auto door close Auto door close
Auto door open
Clamper 1 clamp
Clamper 2 clamp
■ Step
Clamper 2 unclamp
■ Transition
Clamper 1 clamp Clamper 2 unclamp
Machining cycle
Clamper 2 clamp Clamper 1 unclamp Clamper 2 unclamp Auto door open
Conventional (ladder circuit)
-SFC circuit-
*SFC (Sequential Function Chart) :One of five programming languages of PLC, which is defined by IEC 61131-3 Standard.
7
A step means each process and status is displayed as a color. Orange ⇒ Motion is being commanded Green ⇒ Motion command complete
Shows completion of motion and controls shift to next step. The status is displayed through colors. Orange color ⇒ Waiting for motion completion
Page 9
FBD* (Function Block Diagram)function is standard Multi-function controls become a program component, a complicated ladder circuit becomes unnecessary and "Visualization" of a program can be realized.
Configuration Pallet position Lock condition
Related input conditions visualization
FBD A
Automatic
Lock command pallet lock
Jog
Lock command pallet lock
Pallet lock end Out condition
Out valve
Return condition
Return valve
Pallet unlock
Out side LS
Out end
Pallet lock
Return side LS
Return end
Pallet unlock
Pallet lock end
Unlock command pallet lock Unlock condition
B
Automatic
Pallet unlock command
Jog
Lock LS
Return to the original position
A
B
A
B
A function becomes a block.
Unlock LS
Pallet lock end Pallet unlock end
Pallet position Out condition
Lock LS Pallet lock Unlock LS
Lifter bottom end
Pallet unlock end
Return condition
LS error
Visualization of the ladder circuit in a block Contents of FBD Out valve
Re-use Debugging completion
Standard circuits become a part of library by FBD* Apply to other machine systems. Function Block Library
Facilities A
Facilities B
Finished FB
Facilities C
*FBD(Function Block Diagram): One of five programming languages of PLC, which is defined by IEC 61131-3 Standard.
8
Page 10
TOYOPUC-PC10/PC3J Wide range functions
Cycle monitor, I/O recorder Cycle monitor
Program returning function Machine improvement
Cycle diagram just before the machine stop is displayed
A change of this part seems to shorten the cycle time
PC10 USB Memory
This action is abnormal
Record of preset data Max.999 machine cycles
Test mode“ON”
Detailed analysis I/O recorder Record of automaticallyobtained actual I/O (512Kbyte:≒10 machine cycles)
This signal is abnormal
Stop due to an error
Program change, Write-in
No good! Return to the original program
All I/O information is displayed
Test mode“OFF”
Recurrence prevention by root cause can be performed
You can immediately return even when making a mistake in circuit change
Layout and wiring-diagram
A communication-system drawing is also memorized in a PLC.
PCwin Layout・wiring diagrams are also contained in PLC
Program
Layout, wiring
Design
FL-net Displayed data are input into PLC as they are
Control cabinet I/O diagram
Power supply drawings can also be drawn.
PC10
Communication error at L2
This is wrong
The red-color display for error part
Production Maintenance
Broken-down unit
Traceable on monitor screen
9
A part causing an error can be found at a glance