Page 11
TOYOPUC-PC10G
High-power functions in a small body
Efficient CPU function Various sequence programs such as "Equipment control", "Equipment diagnosis" and "Information processing" can be executed by high-speed processing using basic commands of 0.015 μs/word and application commands of 0.05 μs/ word. There are more than 700 kinds of application commands, and signed operation, as well as floating point arithmetic, are possible.
Large capacity memory
Various communication functions Ports L1 and L2 are provided to select FL-net, Ethernet* or FL remote M capable of 10Mbps/100Mbps communication, EtherCAT* capable of 100Mbps communication. Built-in Ethernet is capable of 32 ports opened simultaneously. Port L3 is provided to select the communication with CMP link (computer link), PC link, or SN-I/F (safety PLC TOYOPUC-PCS). By using USB2.0 in connection with PCwin, reading and writing of the program have been achieved at more highspeed than the past. *Please use the cables recommended by JTEKT.
In the large capacity equipment information memory (4Mbyte), helpful information that is useful for adjustment of equipment or maintenance work such as comments, project, SFC and I/O diagram can be stored. The basic area of each program and the memory capacity of a common area have been greatly expanded. Due to the expansion of the basic area, it is possible to store 64 CPU alarm histories. Large capacity expansion USB flash drive 4Mbyte can be used.
TOYOPUC-PC10P PLC for PCI buses
Feature TOYOPUC-PC10P is a programmable controller that can be built into the robot controller with PCI bus, and the data exchange to the robot controller is possible through PCI bus. The CPU function of PC10P is the same function as PC10G-CPU. PC10P-CPU can be enhanced by using FL remote I/O board , TOYOPUC BUS-EXP (EXPANDED BUS). and Plus BUS-EX FL remote I/O board is the remote I/O module of FL remote communication, can be equipped with 40 inputs and 40 outputs, and can be fixed them to a PCI bus rack like PC10P-CPU. TOYOPUC BUS-EXP (EXPANDED BUS) and Plus BUSEX are special expansion module for PC10P using the USB communication. Various modules of the PC2J/3J series can be enhanced by using TOYOPUC BUS-EXP (EXPANDED BUS), a conventional base unit and a power supply module, and by mounting TOYOPUC BUS-EXP (EXPANDED BUS) on the CPU/SEL slot. Function expansion is possible through utilization of Plus BUS-EX. The expansion module of the TOYOPUC Plus series can be mounted additionally.
Efficient CPU function Various sequence programs such as "Equipment control", "Equipment diagnosis" and "Information processing" can be executed by high-speed processing using basic commands of 0.015 μs/word and application commands of 0.05 μs/ word. Moreover, high-speed reading and writing can be enabled by using USB 2.0 for communication with PCwin.
Mass memory The equipment data memory is enhanced to 4MB.
Various communication function PC10P is equipped with one USB port for communication with a peripheral device and one USB port for communication with TOYOPUC BUS-EXP (EXPANDED BUS) and Plus BUS-EX as a standard feature. It is also has two ports (L1, L2) for FL-net capable of 10 Mbps/100 Mbps communication speed, Ethernet* and FL remote M as a standard feature.
*Ethernet is a registered trademark of Fuji Xerox. *EtherCAT is a registered trademark of Beckhoff Automation GmbH.
10
Page 12
TOYOPUC-PC10/PC3J
TOYOPUC-PC3JX series Programmable controller that can be used continuously with ease ■ Executing 3 independent programs.
■ M ounting facilities information memory which realizes
" Visualization"
■ Built-in communication ports
Supports adjustment and maintenance of electric circuit design/equipment ● Three programs can be created and edited independently, and job efficiency is much improved. ● Stored equipment information supports adjustment/maintenance of equipment ● Supporting electrical circuit design by CAD combination
TOYOPUC-PC3JX Sequence CAD
Facilities adjustment / maintenance support Time chart Cycle diagram Machine diagnosis result Circuit diagram display with a comment etc.
Facilities maintenance support Machine diagnosis result display
Peripheral device
Sequence program Ex1 Information processing Ex2 Equipment check
PCwin
11
Facilities information Comment Device code
Ex3 Facilities control program
Cycle diagram
Three independent programs
Facilities maintenance support Machine diagnosis result display
A display, a control panel, etc.
Page 13
TOYOPUC-PC3JX • PC3JX-D PC3J series with higher performance and functionality. Easier to use. As a successor of the PC3J series
As a main PLC of equipment control
PC3JX and PC3JX-D support the data of PC3J, PC3JL and PC3JD. Ladder circuits and built-in communication functions remain usable.
As a CPU of the main PLC for equipment control, PC3JX and PC3JX-D provide stable high-speed control performance and various control functions. Support visualization (SFC*1,FB*2) and highly functional calculation. Aging control equipment for machine tools can be easily rebuilt. These models also conform to EU RoHS.
Specifications Type
Conventional model Conventional model
Subsequent model
Conventional model
PC3J
PC3JL
PC3JX
PC3JD
PC3JX-D
Subsequent model I/O-328G
TIC-5339
TIC-5783
TCC-6901
TIC-5642
TCC-6902
THK-6905
Product appearance
RS-422
RS-422
USB
RS-422
USB
-
No. of ports (with options)
1 (2)
2
2
2
2
-
Used with the 4-wire system of PC/CMP
○
○
○
-
○
-
Model
PC/CMP
PC/CMP
PC/CMP/SN-I/F/*4 MODBUS/SIO
PC/CMP
PC/CMP/SN-I/F/*4 MODBUS/SIO
-
-
-
-
Connection with PCwin*3
Built-in link
DeviceNet*5 master (1port) P1/P2/P3
Program capacity
-
-/-/-
-/32K language/ 32K language
Each 32K language
32K language//32K language
Each 32K language
-
LD
○
○
○
○
○
-
SFC/FB Event monitor
CPU operation mode
-
Each 16K language Each 16K language
FB/standard/user library
Program language
Processing speed
Each 16K language Each 16K language Each 16K language
-
DLNK-M equivalent DLNK-M2 equivalent
-
-
○
○
○
-
-
○
○
○
○
- -
Basic command (min. value)
0.08μs
0.08μs
0.021μs
0.08μs
0.021μs
Application command (min. value)
0.72μs
0.72μs
0.08μs
0.72μs
0.08μs
-
PC 3 divisions/single/PC2
○
○
○
○
○
- -
-
-
○
-
○
Equipment data memory
Plus expansion
448Kbyte
448Kbyte
4Mbyte
448Kbyte
4Mbyte
-
I/O points
1024 points
1024 points
1024 points
1024 points
1024 points
- -
Interruption
-
-
4
-
4
Battery
Yes
Yes
No
Yes
No
-
-
Input 32 points (5 mA) Output 16 points (0.3 A) Output 16 points (0.05 A)
-
Input 32 points (5 mA) Output 16 points (0.3 A) Output 16 points (0.05 A)
Built-in I/O
-
-
Main usability
Performance and functions
● The connection with PCwin has been changed from the
● High-speed processing has been achieved, such as
● The terminal block for built-in communication has been
● The index function, signed arithmetic and floating-point
RS-422 serial port (D sub 15 pin) to USB. ⇒ Programs can be read and written in short time.
changed from the screw type to the no-screw type. ⇒ There will be no screw loosening and tightening error.
reducing the basic command processing time to a quarter of the original time. arithmetic can be used. (Plus expansion mode)
● No battery is required.
⇒ replacement does not need to be controlled, and no replacement cost is necessary.
*1 SFC (Sequencial Function Chart) ※2 FB (Function Block) *3 Use PCwin Ver.14.9 Rev.1 or higher. *4 Only the L2 communication port can be used. *5 DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc.
12
Page 14
TOYOPUC-PC10/PC3J
Input/Output module Building-block type modules makes economical adaptable system for different purposes. of the detachable terminal modules simplifies replacement of a wired module. Monitor helps check the condition of inputs/outputs visually.
Input module Model
PC10 /PC3J
Name
Type
Input type
IN-11 IN-12
THK-2749 THK-2750
AC input
IN-22D
THK-2871
IN-22H
THK-6831
IN-SW
THK-5977
DC input DC high speed input, - *1 It adopts a 16-points display switching system.
Points/module
Isolation method
16 points 32 points
Rated input voltage
Rated input current
AC100/115V
8.5mA 10mA
Photocoupler isolation
DC24V, - - - 15ms or less
15ms or less
Input display
External connection
Common connection
LED illumination when turned on
Terminal block
8 points/ common
LED illumination *2 *1 connector when turned on 1ms~8ms (possible to set LED illumination Free screw per 1 m) initial value: 8 ms when turned on terminal stand, - - - - - - - 10ms or less 10ms or less
5mA
32 points 16 points
Rated response time OFF → ON ON → OFF, - 16 points/ common 8 points/ common, - *2 Includes connector
Output module Model
Name OUT-1 OUT-3
PC10 /PC3J
Type
Output type Points/module
THK-2751
Triac
THK-2931
Independent Relay contact
OUT-4
THK-5040
OUT-11
THK-2795
OUT-12 OUT-15 OUT-16 OUT-18 OUT-19 OUT-28D OUT-29D
8 points
Isolation method Photocoupler isolation
AC100/115V
Relay isolation
AC240/DC24V
Triac
Photocoupler isolation
THK-2752
Relay contact
Relay isolation
THK-2790 THK-2791 THK-2753 THK-2754 THK-2870 THK-5025
MOS FET(−)common MOS FET(+)common Transistor(−)common Transistor(+)common Transistor(−)common Transistor(+)common
*1 Fuse replacement unavailable (soldered) .
16 points
Rated load voltage
Max, load Leak current Fuse current 1A/Point, 1.5A or less 5A/common 4A/common 2A/Point, - DC12/24V
32 points
0.5A/Point, 2A/common
Common connection 8 points/ common independent
Terminal block 8 points/ common
6.3A/common 0.1mA or less
0.2A/Point, 2A/common
*2 It adopts a 16-points display switching system.
Extermal connection on fuse
1A/Point, AC240V 5A/common 4A/common 1.5A or less 0.5A/Point, AC100/115V 2A/common 3.2A/common LED illumination when turned on 2A/Point, AC240/DC24V 5A/common, - 7.5A/common DC5/12/24V 1A/Point,(2A/2point) 4A/common
Photocoupler isolation
Output display
3.2A common*1
LED illumination *3 when turned on*2 connector
16 points/ common
Leak current
Input/output display
*3 Includes connector
Input/output module Model
Name
I/O-328G
Type
THK-6905
Input/output type
Points/module
DC input input 32 points
16 points MOS FET(-)common output for controller Transistor(-)common
PC10
DC input
/PC3J I/O-329G
THK-6410
13
Photocoupler isolation
Rated input voltage Rated load voltage
DC24V output 16 points for signal input 32 points
16 points MOS FET(+)common output for controller Transistor(+)common
Isolation method output 16 points for signal
Photocoupler isolation
DC24V
Rated input current Max, load current 5mA 0.3A/Point, 2A/16Poin 0.05A/Point, 0.8A/16Point 5mA 0.3A/Point, 2A/16Poin 0.05A/Point, 0.8A/16Point
Rated response time OFF→ON、ON→OFF 10msecor less 1msecor less 10msecor less 1msecor less, - 0.1mA or less 0.5mA or less, - 0.1mA or less 0.5mA or less
Fuse, - 3.2A/common LED illumination when turned on, - - - 3.2A/common LED illumination when turned on,
Page 15
Block diagram
Input
Output
IN-11
OUT-1, OUT-11(OUT-4) OUT-3
IN-12, IN-22D, IN-22H
OUT-15
OUT-19
Input/output
Input/output
OUT-12
I/O-329G Input
I/O-328G Input
OUT-16
OUT-18
I/O-329G output for controller
I/O-328G output for controller
OUT-28D
OUT-29D
I/O-329G output for signal
I/O-328G output for signal
Module line up Input module
THK-2749
THK-2750
THK-2871
DC24V IN-22H
IN-SW
THK-6831
THK-5977
Output module TRIAC
Independent Relay contact
TRIAC
TRIAC
Transistor (−)common
Transistor (+)common
Transistor (−)common
Transistor (+)common
Relay contact
FET (−) common
FET (+) common
Input/output module I/O-328G
I/O-329G
THK-6905
THK-6410
通信モジュール
2PORT-EFR
14
Page 16
TOYOPUC-PC10/PC3J
Communication module 2PORT-EFR FL-net function
Adoption of standard protocol for FL-net Various makers' devices can connect with a common network by adoption of the FLnet(OPCN-2) protocol which JEMA(Japan Element Manufactures' Association) defines. This module applies to "Version 2" of FL-net.
●
Model
Name Type
FL-net
Ethernet function
Adoption of global standard protocol TOYOPUC connects with a computer by the Ethernet*. The protocol corresponds to TCP/IP and UDP/IP. ●
FL remote function
Ethernet*
Collection of I/O communication and diagnostic information By connecting with FRMT series, remote I/O communication, which performs I/O data exchange regularly, and diagnostic information can be collected by just link parameter setting.
FL remote
FL remote function
PC10G/PC3J 2PORT-EFR THU-6404 Station number Max. 254 stations 2048/8192 points (8192 points are applied Relay link number to since PC3JG and PC10G) 2048/6144/8192 words (selected by a switch) Register link number (6144/8192 words are applied to since PC3JL, PC3JD, PC3JG, and PC10G) Transmission rate 10Mbps/100Mbps Date link method N:N communication, 1:N communication Port number Max. 8 ports Computer link data capacity Max. 1K byte × 8 ports Transmission 2Kbyte × 8 ports File memory data capacity Receiving 2Kbyte × 8 ports Transmission rate 10Mbps/100Mbp ①Computer link function, Transmission function ②File memory function ③General purpose communication function Station number Max. 63 stations (except Master) I/O points Input: Max. 2048 points, Output: Max. 2048 points I/O points Input: Max. 64 points, per 1 slave Output: Max. 64 points Transmission rate 10Mbps/100Mbps
SW-HUB
FRMT Series
Name
Type
Polarity
Name
Specifications
Type
32 points
0 point
TCU-6405
PNP
FE-SWH05
5 port switching HUB
TCU-6414
FRMT-00/32P
0 point
32 points
TCU-6406
PNP
FE-SWH08
8 port switching HUB
TCU-6415
FRMT-16/16P
16 points 16 points
TCU-6407
PNP
FRMT-32/00P
Input number Output number
FE-SWH05
FE-SWH08
A system configuration example FL remote Master
I/O power supply monitoring information and disconnection short-circuit information are collected. SW-HUB
FRMT
Sensor
Short circuit
*Ethernet is a registered trademark of Fuji Xerox.
15
Actuator
Disconnection
Page 17
*
Master EtherCAT* master function is equipped to PC10G-CPU, PC10P and Plus CPU*1. ●
High speed, large volume communication
●
Flexible network topology (Daisy chain/Star)
●
Network diagnostic function
Item
Specification
Corresponding model
PC10G PC10P Plus CPU*1
High speed, large volume communication is possible
Protocol
EtherCAT* with the adoption of the EthernetCAT* protocol.
transmission rate
100Mbps
Connection to other manufacturers' devices which
Communication distance
Max. 100 m between nodes
Max. connections
32(1 Master, 31 Slaves)
Input/output data size Process data communication
Input: Max. 4096 bytes Output: Max. 4096 bytes Non-synchronous (Free Run) mode (Synchronous mode is not supported.)
support EtherCAT* is possible. For EtherCAT*, only one port can be used for one CPU.
*1 be used at each EX, EX2, EFR and EFR2 board. EFR or EFR2 requires either EX or EX2.
Slave The remote input/output device is equipped with 2 types of branching slaves of 3-port and 6-port and with the detection function for short circuit and breakage of wiring. Remote I/O terminal Name EC-32/00P
Input number Output number
Type
32p.
0p.
TCU-6922
EC-00/32P
0p.
32p.
TCU-6923
EC-16/16P
16p.
16p.
TCU-6924
Polarity PNP
Branching slave Specifications
Type
EC-03JS
Name
3-port branching slave
TCU-6925
EC-06JS
6-port branching slave
TCU-6926
Setting tool KPA EtherCAT Studio [type: TJA-6927] is necessary for creating and editing EtherCAT* networks.
*EtherCAT is a registered trademark of Beckhoff Automation GmbH.
16
Page 18
TOYOPUC-PC10/PC3J
DeviceNet
*
Master
Slave
DLNK-M2
DLNK-S, DLNK-S2
J-DLNK-M2 is a TOYOPUC-PC 3J/10G DeviceNet compatible master module.
An abundant I/O mdules are available, which are mounted on the PC10G/PC3J base.
DLNK-S THU-5441
Remote I/O and message communication are supported. Full time I/O data exchange remote I/O communication and message communication which transmit on-demand command and receiving data are supported. The message communication can write and read special information (error information, status and so on) and setting data to a slave which has a special function.
Diagnose information collection The result information of diagnostic function I/ O remote terminal can be collected by just link parameter setting, not with making message issue program. ●
Large line up of I/O modules Being able to use a large number of I/O modules of PC10G/PC3J enables you to select any kinds of actuator and sensors(24V DC, 100V AC) as widely as you like. J-DLNK-S2 can perform I/O data exchange among computers.
●
With diagnostic functions
Remote I/O terminal DRMT Series The DRMT series is DeviceNet compatible Remote I/O terminal with input/output wiring short circuit or wire-cutting detection function.
DLNK-M2 communication specifications
●
Items
Specifications
Type
THU-6099
Communication speed
500/250/125kbps (selected by a switch)
Max.connected node
64 units (Master 1, Slave 63)
I/O points
Max. 2048 (256 byte) , input and output
I/O allocation
Minimum 8 points unit
Link aera
X・Y, L, M, EX・EY, EL, EM, GX・GY, GM speed
Network max. length
Total branch length
Communication
500kbps Less than 100m Less than 6m Less than 39m
Name distance
250kbps Less than 250m Less than 6m Less than 79m
DRMT-32/00P
125kbps Less than 500m Less than 6m Less than 156m is a registered trademark of Open DeviceNet Vendor Association Inc.
17
Branch length
Input points Output points
Type
32p.
0p.
TFU-6110
DRMT-00/32P
0p.
32p.
TFU-6111
DRMT-16/16P
16p.
16p.
TFU-6112
DRMT-32/00
32p.
0p.
TFU-6120
DRMT-00/32
0p.
32p.
TFU-6121
DRMT-16/16
16p.
16p.
TFU-6122
Polarity
PNP
NPN
Page 19
Multi-link ML10 can be used as the succession model of PC/CMP-LINK, PC/CMP2-LINK, 2PORT M-NET and 2PORT-LINK. ML10 also supports RoHS.
●
ML10 also supports SIO and MODBUS-RTU.
●
Module name
Type
No. of communication ports
PC link
Computer link
M-NET
SIO
ML10
TCU-6903
2
○
○
○
○
○
PC/CMP-LINK
THU-2755
1
○
○
-
-
-
2-wire system
PC/CMP2-LINK
THU-5139
1
○
○
-
-
-
2-wire system/4-wire system
2PORT-LINK
THU-2927
2
○
○
-
-
-
2-wire system
2PORT M-NET
THU-5093
2
-
-
○
-
-
2-wire system
Link function PC link Computer link
M-NET
SIO
MODBUS-RTU※
MODBUS* 2-wire system/4-wire system 2-wire system/4-wire system
Changes in communication specifications in ML10 No changes in communication specifications Transmission rate : Supports 38400, 57600 and 115200 bps Supported commands : Supports expansion command for PC10 mode Communication specifications : Supports RS-485/RS-232C No changes in communication specifications The pin layout of terminal block is not compatible with conventional model 2PORT M-NET. Compatible with conventional model SIO module Supports half-duplex mode of RS-485 The control signal is not supported during RS232C. Supports the MODBUS*-RTU function Transmission rate : 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps Supports RS-485/RS-232C
High-speed PC link communications and high-speed processing are realized with this PLC link.
● control by up to 32 stations is available.
● data link can be constructed with a maximum of 2048 relay link points or a maximum of 1792 register link bytes.
● modules are connected with twisted pair wires even for high-speed link, wiring is simple.
● of a programmer (PCwin) allows remote monitoring and programming of any station.
●
Model
PC10G / PC3J
Name
HPC-LINK
Type
THU-2758
Transmission rate
625Kbps
Transmission cable
Shielded twisted pair wires*
Transmission distance
Max. 500m [0.31mile] (Total length)
No.of linked stations
Max. 32 (Master1,satellite31)
No.of linkage points
Relay Link Max. 2048points Register Link Max. 1792bytes linkage method
N:N
*Use of JTEKT recommended cable is desirable.
*MODBUS is a registered trademark of AEG Schneider Automation Inc.
18
Page 20
TOYOPUC-PC10/PC3J
High-speed remote I/O Enables you to distribute data to I/O devices in remote locations with greatly reduced wiring costs. Reliability and maintainability are also remarkably improved.
●
High-speed transmission and high-speed processing reduce the response delay of satellite I/O.
●
Input/output modules are randomly located freely in a satellite station.
● ● is simple, with a twisted-pair cable sufficient even for high-speed linkage. Remote monitoring and programming of the master station CPU from the satellite station are available using a programmer (PCwin).
●
●
Terminal Model
PC10G / PC3J
Name
RMT-I/O M
RMT-I/O S
Type
TUH-2756
TUH-2757
Function
Master
Satellite
Transmission rate
625kbps
Transmission cable
Shielded twisted pair wires*1
Transmission distance
Max. 500m [0.31 mile] (Total length)
No.of linked stations
Max. 32 (Master 1,satellite 31)
Transmission timing
Synchronous to sequence scan or asychronous (selected by a switch)
No.of linkage points
Max. 2048
No.of I/O points, Max. 256*2
Power supply voltage, - *1 Use of JTEKT recommended cable is desirable. *2 With 8 32-point modules on an 8-slot base.
Serial I/O SC10 can be used as the succession model of conventional model SIO module. SC10 also supports RoHS.
●
Supports transfer speeds of 38.4 Kbps and 115.2 Kbps.
●
Model
SC10
Type
TCU-6904
Interface standard
EIA RS-232C
No. of channels
2 channel/module
Transmission rate
300/600/1200/2400/4800/ 9600/19200/38400/115200bps
Transmission distance
15 m (4.9 ft)
Synchronous method
Asynchronous
Transmission type
Duplex
Transfer procedure
Teletype protocol, XON-XOFF, control signal
Data length Data type
Parity Stop bit
Communication data
19
PC10G/PC3J
Name
7、8bit even/odd/none 1, 2bit 1024 bytes/channel