Page 21
Pulse output The pulse output module performs independent single-axis simple-position control of a servo motor or stepping motor, which is combined with a pulse-input type motor driver. ● Operation mode control, - Pulses are output until reaching to the command position. signal positioning, - At the stop command ON, pulses are decreased and then stopped. This operation can be performed by a travel completion signal or an external signal using together with positioning control., - Speed change at real-time is possible. of command pulse amount, - Pulse are output at the amount of command. The amount of command pulse can be changed at a real-time., - Pulses are output at a step of 1, 10, 100, 1000 pulses.
Others ・Backlash compensation ●
・Setting of current position
Model
・Teaching
PC10G / PC3J
Name
PULSE OUTPUT
Type
THK-5109
No.of control axes
1
Position command range
-134,217,728-134,217,727 pulse
Acceleration pattern
Trapezoidal
Feed rate
(1-8192) ×30pps (max 245,730pps)
Output
No.of points
2
Signals
Forward pulse, reverse pulse
Rated load voltage
5−24VDC
Max. load current
50mA/signal
Input
No.of points Signals
7 Origin, near origin, +limit, −limit, external positioning signal, in position, operable
Rated load voltage
24V DC (5V input possible for origin, in position)
Rated input current
10mA
*AS-i is an open network of AS-international (AS-i association).
20
Page 22
TOYOPUC-PC10/PC3J
High-performance analog input
8 channels and 16-bit high resolution are available (using PC10 mode)
Very high precision ±0.3% (using PC10 mode)
Very high conversion speed at 60 μ sec/channel (using PC10 mode) Model
PC10G / PC3J
Name
AD10
Type
TCK-6529
Mode Analog input range
PC10 mode
Conventional I/O mode
−10〜+10V、0〜+10V、 0〜+5V、+1〜+5V、 0〜20mA、4〜20mA
0〜+10V、0〜+5V、 +1〜+5V、 0〜20mA、4〜20mA
Digital output
User range
16 Bit With Sign
Extended I/O mode −10〜+10V、0〜+10V、 0〜+5V、+1〜+5V、 0〜20mA、4〜20mA
12 Bit Binary
16 Bit With Sign
Resolution
1/32000
1/24000
1/4000
1/32000
1/24000
Total accuracy
±0.3%
±1.5%
±0.4%
±0.3%
±1.5%
Conversion speed
60 μs/channel
Number of channels
8 channels
Range selection
Settings for every channel
4 channels
3 channels All channel same
Input impedance
Voltage 1M ohm Current 250 ohms
Maximum input
Voltage±15V Current ±30mA
Wire length
Less than 30m (to avoid noise influence , please shorten as much as possible.)
Isolation
Insulation by an isolator (between a PLC-analog input) Non-isolation between analog input channels.
I/O Address Occupied I/O point by link parameters by mounting positions (I/O handling).
0 point
64 points
Analogue output An analog output module will be arranged depending on output specifications. Analogue output 2channels/module
●
Resolution 1/4095
●
Conversion speed 2.5mS
●
Voltage output or current output selectable
●
Model
PC10G / PC3J
Description
Analogue output
Name
DA-1
DA-2
Type
THK-7931
THK-7932
Input Output Conversion speed No.of channels Resolution Overall accuracy Power supply
12-bit binary data/channel 1〜5V
4〜20mA
0〜10V 2.5ms 2 Full scale/4095 ±1%FS
External power supply 24VDC±10%, internal power supply 5VDC
Max.input, Max.output
Voltage output 10V (External load 670Ω or over) , current output 20mA (Extenal load 400Ω or less)
I/O points occupied
21
User range
32 points
Page 23
High-speed counter This module enables counting and comparison of high speed input that cannot be tracked by the counter command and input module of PLC.
●
CT10 has improved the function of the conventional high speed counter module and had been made to support RoHS.
●
Supports 2 channels
●
Supports differential inputting (RS422).
●
Supports high speed pulse of max. 8 Mpps.
●
Model
PC10G/PC3J
Name
CT10
Type
TCK-6856
Mode Applied PLC model No. of channels Counting input Signal level
PC10 Mode
Conventional high speed counter mode
PC10G
PC10G/ PC3J
2
1
1-phase addition/subtraction 2-phase addition/subtraction 2-phase phase difference (Multiplications of 1, 2 and 4)
DC input Differential input
Counting speed (Max.)
Counting range No. of comparison points Comparison output I/O points occupied
24 / 12 / 5V RS-422 8 Mpps during differential input (2-phase, multiplication 4) 200 kpps during DC input (2-phase, multiplication 4) 32 bit without symbol 32 bit with symbol Internal: 8 points at all CH External: 8 points shared by CH 1 and 2
Does not support 50 kpps during DC input 24 bit without symbol 24 bit with symbol Internal: 8 points External: 6 points
ON when the value in within preset comparison range. 0 point
Non-polar 64 points
22
Page 24
TOYOPUC-PC10/PC3J Configuration Input module
Base (Use the specific base for PC2 JS/JR) DC24V IN-22H
IN-SW
THK- 6831
THK-5977
8-slot base (2) THR-2872
8-slot base
THR-2766
6-slot base
THR-2813
4-slot base
THR-2775
2-slot base
THR-2814
Output module TRIAC
Independent Relay contact
TRIAC
TRIAC
Relay contact
Transistor Transistor Transistor Transistor (−)common (+)common (−)common (+)common
FET (−) common
FET (+) common
Input/output module I/O-328G
THK-6905
I/O-329G
THK-6410
Communication module Multi-link ML10
High-speed PC link HPC-LINK
High-speed remote High-speed remote I/O Master station I/O Satellite station RMT-I/O S RMT-I/O M
TCU-6903
I/O branch module
Selector base
Serial I/O SIO
2PORT-EFR
I/O cable
8-slot selector base
THR-5643
6-slot selector base
THR-5644
4-slot selector base
THR-5645
THU-6404
Special module Analogue input AD10
Analogue output DA1-DA2
Pulse output PULSE-OUT
High-speed counter CT10
TCK-6856
23
Motion controller MCML
TCI-6721
Motion controller MCSSC
TCI-6805
Page 25
PC10G
Peripheral equipment
Windows 2000/XP/Vista/7
PC10G-CPU TCC-6353
PLC built into a robot controller with PCI bus
PC10P dedicated extension module
USB* connection
USB* connection
PC10P-CPU TCC-6372
TOYOPUC BUS-EXP (EXPANDED BUS) TCU-6367
PlusBUS-EX Printer
CPU module of PC3JX and PC3JX-D (Purchased on the market)
*Recommended USB cable
PC3JX TCC-6901
Elecom-made USB2-FS05 USB2-FS15 USB2-FS3 UC2-BN07BK UC2-BN10BK UC2-BN15BK UC2-BN20BK UC2-BN30BK UC2-BN50BK
PC3JX-D TCC-6902
Selector module
0.5m 1.5m 3.0m 0.7m 1.0m 1.5m 2.0m 3.0m 5.0m
Power module
24
Page 26
Board type PLC
Board type PLC TOYOPUC-Plus
Evolving in line with change, from manual to semiautomatic, then on to fully-automatic equipment The ideal board-type PLC for built-in application. ■ It is possible to configure everything from the independent control of manual equipment to the decentralized control of fully-automatic equipment. ■
Achieving the simple configuration of equipment control TOYOPUC-Plus, being only the size of a postcard, works away diligently behind-the-scenes. By having TOYOPUC-Plus built in to your operation panel, a simple control system with an equipment control function is possible. Functions can be built freely depending on screen data and sequence programs, and external devices can be connected through communication. Connection with the upper server/PCs Ethernet*
Connection with other equipment/processes FL-net*
Connection with remote I/O FL Remote/EtherCAT*/DeviceNet*
An example of a PLC box installed separately from the operation panel
PC/CMP/SN-I/F
*Ethernet is a registered trademark of Fuji Xerox. *FL-net is the controller level network (OPCN-2) stipulated by JEMA (The Japan Electrical Manufacturers' Association) *EtherCAT is a registered trademark of Beckhoff Automation GmbH. *DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc. *CC-Link is a registered trademark of Mitsubishi Electric Corporation. *MECHATROLINK is a registered trademark of MECHATROLINK Association. *SSCNET is a registered trademark of Mitsubishi Electric Corporation.
25
Ethernet*/FL-net*/FL Remote/ EtherNetIP/EtherCAT*
Page 27
It can be expanded into a control system suitable for the equipment scale On TOYOPUC-Plus, functions can be added per board. Controlling small scale equipment with a minimal configuration (1 board). TOYOPUC-Plus allows for expansion in the limited space of automatic equipment and configures the ideal control system. TOYOPUC-Plus does not require PLC model changes, but meets fluctuations in production volume with flexibility. An equipment and control configuration example Semi-automatic equipment
Manual equipment Connect actuators and sensors with easy operations and I/Os and controlling.
Connect workpiece loading/unloading robot with communication and add control. Plus CPU
Plus CPU
Plus IO24/16P Plus DLNK-M
+ Add communication for robot and I/O for interlock
Minimal configuration
Fully-automatic equipment
Plus CPU Plus IO24/16P Plus DLNK-M
Connect betweenprocess conveyance equipment with communication and add control. Connect an upper server production control system with communication.
Plus EFR
+ Communication for conveyance Upper server communication added
Communication for robot and I/O for interlock
Achieving visualization of control through an array of functions SFC and FBD functions are equipped as standard, and can be easily operated using the follow-up monitor. *SFC (Sequencial Function Chart), FBD (Fanction Block Diagram)
Achieving a motion control function Achieves max. 16-axis compact motor control.(When mounting two , Plus MCML / MCSSC)
Refer to page 30 for the assembly of the communication board.
CPU board
Expansion I/O module
Memory expansion Ethernet* system communication board (supports EthernetIP)
DeviceNet* communication board
72
90
Ethernet* system communication board (supports EthernetIP)
Plus CLNK-M CC-Link* master communication board
84
84
Motion control board MECHATROLINK*-Ⅲ
Motion control board SSCNETⅢ*
Plus CLNK-S CC-Link* slave communication board
60
Plus EFR2
90
Plus DLNK-M
66
73
Plus EX2
140
Ethernet* system communication board
72.5
70
Plus MCSSC
90
Memory expansion Ethernet* system communication board
72.5
140
140
90
90
Plus MCML
72.5
72.5
Plus IO24/16P
60
Plus EFR
Plus EX Plus CPU
140
Board type (total 11 types)
90
26
Page 28
Compact PLC
Compact PLC TOYOPUC-PCDL
Multiple-purpose distributed control is available using the various communication function in a small size.
Main features
Conventional user-friendly TOYOPUC programming is inherited.
Flexible programming by 3 languages (LD, SFC, FBD) possible.
optimal compact PLC suitable for space-saving distributed control with the communication function.
Flexible system extendibility by abundant communication functions.
Base module
Various modules
(for 2, 3, 5 or 8 slots) - Built-in power supply - DIN rail fixing - A base module for AC power or DC power available
- Input/output module - Analogue module - Extension module
CPU module
Program capacity: 16K words (LD, SFC part) One program (FBD:8K words) Machine information memory: 64KB Communication functions - I/F : RS232C (PCwin) / MODBUS*-RTU (Slave) → A selection from 2 kinds - L1 : FL-net - L2 : (Slave) / Serial I/O (SIO) / PC-LINK / SN-I/F → A selection from 5 kinds
Connection example
PCwin
PC10G-CPU FL-net
SN-I/F
*MODBUS is a registered trademark of AEG Schneider Automation Inc.
27
TOYOPUC-PCS-J
Page 29
TOYOPUC-PCk series
Compact, yet it is applicable to multipurpose usage
PCk05-CPU
PCk06-P-CPU
PCk05-CPU is a micro type PLC with 8-point input and 6-point output.
PCk06-P-CPU is a mixed type PLC of all-in-one design type with 20-point input and 16-point output and module type.
RS 232C port is equipped as a standard feature.
1 slot is arranged for expansion. It is possible to expand to the max. 30 points.
The DeviceNet* slave module is also arranged. It is easy to communicate with various TOYOPUC series.
It is a small type PLC with 20-point input and 16-point output.
RS 232C/422/485 ports are equipped as a standard feature.
4 slots are arranged for expansion. It is possible to expand to the max. 100 points.
The DeviceNet slave module is also arranged. It is easy to communicate with various TOYOPUC series.
Rich convenient functions ●
It is possible to communicate with TOYOPUC series, using DeviceNet* Slave module of kDLNK.
●
I/F is possible to connect with PCwin-PCk.
●
Port 2 of PCk06-P-CPU is possible to connect with RS232C/422/485 MODBUS*.
TOYOPUC series
PCk series
RS232C/422/485
DeviceNet*
PCk connection cable PCwin-PCk
DC input specifications Items
Model
Address allocation Rated input voltage Max. input current
PCk05-CPU (TKC-6471) X0〜X2 (high speed input) X3〜X7 (standard input) DC12-24V 6mA (DC12V) 4mA (DC12V) 13mA (DC24V) 8.5mA (DC24V)
PCk06-P-CPU (TKC-6472) X0〜X3 (high speed input) X4〜X13 (standard input) DC12-24V 6mA (DC12V) 4mA (DC12V) 13mA (DC24V) 8.5mA (DC24V)
Output specifications Model Items
Address allocation Rated load voltage Max. load current
PCk05-CPU (TKC-6471) Relay output specifications Y400〜Y405 DC6-27V、AC6〜240V (47〜63Hz) 2A/point, 6A/common
PCk06-P-CPU (TKC-6472) DC output specifications Y400〜Y401 (pulse output) Y402〜40F (standard output) DC12-24V 0.5A/point 1A/point
*DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc. *MODBUS is a registered trademark of AEG Schneider Automation Inc.
28
Page 30
Specifications PC10, PC3J Series control specifications Model PC10G PC10P PC3JX PC3JX-D Programming method Stored program method Event monitor function by parameter setting Program control method Cyclic operation method Constant period interruption function (1 ms〜) Cyclic operation method Constant period interruption function Input/output control method Image registration method Basic instruction processing speed Contact…0.015μs〜 /instruction Basic command: 0.021 μs (fastest) Application instruction processing speed 0.05μs〜 few μs/instruction 0.08 μs/word Basic instruction 19 instructions + 1 instruction (the inversion output for screen buttons) 19 instructions 20 instructions Timer counter instruction 21 instructions + 1 ms timer, 1s timer 21 instructions 29 instructions Over 700 commands Data type: BIN, BCD, signed BIN 700 instructions or more The operation with the sign Application instruction 450 instructions or more is possible. The floating decimal point is possible. Floating point (single precision, double precision) Size: byte, word, double word 180K words (60K words × 3) (60k words / 60K words 48K words (16K words × 3) 180K words (60K words × 3) / 60K words, 120k words / 60K words, 180K words) + FB library 32K words + FB library 60K words Program capacity + FB library 60K words + Standard library 32K words + Standard library 32K words + Standard library 32K words + User library 32K words + User library 32K words + User library 32K words Memory element CMOS-RAM, Flash EPROM CMOS-RAM, FRAM Battery Rechargeable (Lithium secondary battery: battery longevity 5 years) None 1,024 points No. of external I/O 2048 points (Increase is possible by DeviceNet* and remote I/O 79,872 points 86,016 points 79,872 points (2,048 points × 3 + No. of internal output (4,096 points × 3 + 8,192 points + 65,536 points) 8,192 points + 65,536 points) (2,048 points × 3 + 73,728 points) No. of keep relay 6,400 points (768 points × 3 + 4,096 points) 0.1〜6553.5 sec / 0.01〜655.35 sec 0.1〜6553.5 sec / 0.01〜655.35 sec 0.1〜6553.5 sec / 0.01〜655.35 sec Timer function 0.001〜65.535 sec / 1〜65535 sec total 3,584 points 0.001〜65.535 sec / 1〜65535 sec total 9,728 points total 3,584 points Counter function 1〜65,535 (2,560 points × 3 + 2,048 points) 1〜65,535 (512 points × 3 + 2,048 points) 1〜65,535 (512 points × 3 + 2,048 points) No. of link relay 39,912 points (10,240 points × 3 + 8,192 points) 14,336 points (2,048 points × 3 + 8,192 points) Detection of start-up and start-down 11,776 points (2,560 points × 3 + 4,096 points) 5,632 points (512 points × 3 + 4,096 points) 164K words / 16 bit (12K words × 3 +128K words) 44K words / 16 bit (4K words × Data register Extension buffer register: 256K words / 16 bit 3 + 32K words) Extension buffer 12K words(4K words × 3 + 32K words) Flash register: 4Mbyte flash drive (read only)*1 register: 128K words / 16 bit Link register 6K words / 16 bit (2K words × 3) Equipment data memory 4Mbyte Program comment, SFC data, FB data, I/O diagram, network diagram 4Mbyte *2 Communication (link) module: MAX. 24 Special module installation Communication (link) module: Max 24 sheets, - No number of sheets limitation by the consumption memory amount Unlimited number depending on memory usage SFC ○ Visualization function F B ○ F B ○ Library function Standard ○ User ○ Event monitor function (possible to monitor at the cycle) ○ Compulsion ON/OFF function ○ Scan unit trace function ○ Equipment diagnosis function ○ Diagnostic dummy: 2,048 points 128 histories ○ Maintenance Network diagnosis function ○ support I/O diagram display ○ I/O recorder ○ 512Kbyte (50 points / change point in one cycle → memory of about 40 cycles) ○ Test mode ○ Function to return instantaneously to former program when program change is confirmed ○ Programmer I/F USB (V2.00) 480Mbps L1: FL / ET / F remote M 10Mbps/100Mbps L1:PC/CMP/MODBUS/SIO L1:PC/CMP/MODBUS/SIO Built-in communication L2: FL / ET / F remote M 10Mbps/100Mbps function SIO/SN-IF DLNK-M2 L3: PC/CMP/SN-I/F L3: PCI bus I/F Items
*1 The range where special instruction is necessary for writing in. *DeviceNet is the registered trademark of Open DeviceNet Vendor Association Inc. *2 PC10P can be equipped with the special module through the use of BUS-EXP (EXPANDED BUS) or Plus BUS-EX.
Compact PLC PCk series control specifications Items
CPU function
Model
Programming method Program control method Program language Input/Output control method Basic instruction processing speed Application instruction processing speed Basic instruction Timer/Counter instruction Application instruction Program capacity Memory device Battery External I/O points Internal output points Keep relay points Timer function
Counter function Link relay points Rising/Downing edge detection External power No. of modules possible to install Installation method I/F Communication function Port 2 Programmer Peripheral software Cable
PCk05-CPU
PCk06-P-CPU Stored program method Cyclic operation method (with sub routine function) LD Image register method Contact 1.3〜2.3μs/instruction, Output 6.8〜34.4μs/instruction Contact 0.37〜0.67μs/instruction, Output 1.82〜9.2μs/instruction 2.4〜several 100μs/instruction 13 kinds 6 kinds More than 110 instructions 2,048 words 7,679 words USB flash drive, RAM Commercial battery CR2354, - - (Battery life: 5 years, however, please replace to a new battery if the system was shut down for 10 days or more.) Input : built-in 8 points + points of mounting modules Input: built-in 20 points + points of mounting modules Output : built-in 6 points (Relay output) + points of mounting modules Output: built-in 16 points (Source output) + points of mounting modules 256 points 512 points 256 points 512 points 128 points, 0.1〜999.9sec./0.01〜99.99sec. 256 points, 0.1〜999.9sec./0.01〜99.99sec. 128 points, 1〜9,999 128 points, 1〜9,999 Input 1,024 points, output 1,024 points 512 points 3,200 words 7,296 words Data register 1 4 DIN rail or set screw (screw size: M4) PCwin-PCk for programmer only RS232C (MODBUS*) RS232C/422/485 (MODBUS*) PCwin-PCk Cable connecting PCk (TKY-6485) *MODBUS is a registered trademark of AEG Schneider Automation Inc.