"Circuit monitor" function, which can display/monitor SFC, FBD, and LD circuit.
PLC direct monitoring SFC ,which displays machine operation step as a flow chart. Therefore, when machine stops, the stopping operation step can be known at a glance. Touching the stopping operation step , a stop conditions is searched and relative FB and a relative ladder are displayed.
Touch
Touch
"Tracing monitor" function, which can locate a fault position at pinpoint from an error button to an I/O drawing
Touching an error button on an operation panel screen and search the error conditions in a ladder circuit, then the relative circuits are displayed. Touching ladder circuit conditions, then the cause of error can be traced. Furthermore, if error conditions are I/O, the error cause can be traced at I/O drawings, therefore the machine error place can be specified quickly and MTTR can be shortened. A worker can be released from the stress of reading many circuit diagrams or l I/O drawings as before he did.
Touch
Touch
Operating panel screen
Circuit monitor
I/O drawing display
Trouble shooting time reduction
Dramatic MTTR shortening Index
10 Conventional system
1 Traceing monitor
40
Page 42
Direct circuit monitor
"Network diagnostic" function shows the failure place of a communication device or wiring place
Communication errors of devices or grounding and disconnection place are diagnosed and the error place can be pinpointed. Functions are applicable for FL-net, DeviceNet* and FL remote. Grounding and disconnection are applicable for DeviceNet* and FL remote. Communication-system drawings memorize in a PLC/PCwin
FL-net L1 Station number 1
L2 Station number 2
L3 Station number 3
R1 Station number 4
R2 Station number 5
R3 Station number 6
Operation panel / Direct circuit monitor
The devices are pointed on the communication-system drawing of the operation-panel screen.
From record of the number of device operations, and record of usable years, the inspection time limit can be seen by "fixed-quantity and periodic maintenance" function
100 components for the fixed quantity maintenance and 100 components for periodic maintenance can be registered A machine is always monitored, if a actual value exceeds an inspection period, an inspection advice message will be displayed on a screen. Therefore, a maintenance plan like spare-parts preparation can be planned
Inspection advice and object components are displayed on a screen.
Fixed quantity maintenance
Periodic maintenance
*DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc.
41
Page 43
General specifications Model
Item
Operating ambient temperature Operating ambient humidity Storage temperature range
DM-12WK2B
DM-12WD4
DM-12WK2
DM-10WF
DM-7WS
0-55 degrees C
0-55 degrees C
0-55 degrees C
0-55 degrees C
0-50 degrees C
25~85%RH, no dew condensation.
10~90%RH, no dew condensation
25~85%RH, no dew condensation.
30~85%RH, no dew condensation.
5~85%RH, no dew condensation.
-10~70 degree C
-20~60 degree C
-10~70 degree C
-40~85 degree C
-20~60 degree C
Power supply
AC100V/240V
DC12/24V 56W
DC24V 50W以下
DC24V less than 30W
DC24V less than 32W
Grounding method
D class grounding
D class grounding
D class grounding
D class grounding
D class grounding
IP65f equivalent (when surface sheet attached)
IP20 (Compatible with IEC 60529)
Protective construction External dimensions (mm) Panel-cut dimension (mm)
−
−
−
315(W)×241(H)×70(D)
306(W)×260(H)×66.9(D)
306(W)×261(H)×55(D)
233.2 (W) ×213 (H) ×65.4 (D) 214 (W) ×158 (H) ×79.6 (D)
301.5(W)×227.5 (H)
270(W)×206 (H)
266(W)×203 (H)
224.7 (W) ×174 (H)
197 (W) ×141 (H)
Cooling method
Natural air cooling
Natural air cooling
Natural air cooling
Natural air cooling
Natural air cooling
Weight (kg)
3.7
3.7
2.6
1.8
1.5
Performance specifications Model
Item
OS
DM-12WK2B Enbedded STD 7
DM-12WD4
DM-12WK2
Enbedded STD 7
Enbedded STD 7
DM-10WF
DM-7WS
Windows Embedded Standard 2009
Windows Embedded Standard 2009
CPU
Intel Atom D425
Intel Atom E660
Intel Atom D425
Intel Atom N450 1.6GHz
Intel Atom E640 1.0GHz
Main memory (RAM)
1GB
2GB
1GB
1GB
1GB
System memory
4GB
16GB
4GB
5GB
4GB
Touch panel
Analog resistance film system
Analog resistance film system
Analog resistance film system
Resistance film (4-line type)
Analog resistance film system
Display
TFT 12.1 inches color LCD
TFT 12.1 inches color LCD
TFT 12.1 inches color LCD
TFT 10.4 inches color LCD
TFT 7 inches color LCD
Display resolution
1024×768 (XGA)
1024×768 (XGA)
1024×768 (XGA)
1024×768 (XGA)
800×480 (WVGA)
Resume function
None (suspension function by battery OP)
−
−
−
−
Interface specifications Model
Item
USB Serial port
DM-12WD4
DM-12WK2
DM-10WF
DM-7WS
None (suspension function by battery OP)
DM-12WK2B
5 ports (for data communicaiton and for maintenance purposes)
4 ports (for data communicaiton and for maintenance purposes)
2 ports (for data communicaiton and for maintenance purposes)
3 ports (for data communicaiton and for maintenance purposes)
1 ports
2 ports
2 ports
1 ports
1 ports
2 ports 2 ports (LAN1 : for TOYOPUC connection, (LAN1 : for TOYOPUC connection, LAN2 : for upper PC connection) LAN2 : for upper PC connection) Expansion unit − (sold separately)
Ethernet PCI bus
2 ports 2 ports 2 ports (LAN1 : for TOYOPUC connection, (LAN1 : for TOYOPUC connection, (LAN1 : for TOYOPUC connection, LAN2 : for upper PC connection) LAN2 : for upper PC connection) LAN2 : for upper PC connection) Expansion unit − − (sold separately)
CF card
2 slot (for system disc)
2 slot (for system disc)
2 slot (for system disc)
2 slot (for system disc)
Analog RGB
Mini D-SUB15 pin (socket)
DVI-D (socket)
Mini D-SUB15 pin (socket)
Mini D-SUB15 pin (socket)
1 slot (for system disc) −
Type Model
Item
DM-12WK2B Name
Main body
Direct circuit TYD-6964 monitor Main body −
Optional parts
Specifications
Battery unit
−
Back light for replacement
−
Surface sheet
−
Protection sheet
−
− − (Option to be decided ) Refundable product − (To be decided)
DM-12WD4 Name
DM-12WK2
Specifications
Direct circuit TYD-6961 monitor Main body Set with sheet (main unit, surface TYD-6962 sheet, protective sheet)
Name
DM-10WF
Specifications
Direct circuit TYD-6959 monitor Main body Set with sheet (main unit, surface TYD-6960 sheet, protective sheet)
−
−
−
−
−
Refundable product
−
Refundable product
TYD-6735 Surface sheet TYZ-5929
TYD-6735 Surface sheet
Protective sheet
TYZ-5929
Protective sheet
Name
DM-7WS
Specifications
Name
Specifications
Direct circuit TYD-6745 monitor Main body Set with sheet (main unit, surface TYD-6754 sheet, protective sheet)
TYD-6797
Direct circuit monitor Main body
TYD-6871
TYD-6869
Battery for clock 1
Battery for clock 1
Refundable product Surface sheet TYD-6833 (for DM-10WF) Protective sheet TYZ-6778 for screen 1 sheet (for DM-10WF) −
−
Refundable product
−
−
Protective sheet TYD-6812 for screen 1 sheet (for DM-7WS)
Drawing tool type (Common to DM-12WK2B, DM-12WD4, DM-12WK2, DM-10WF, DM-7WS) Item ScreenWorks-T
Name TJD-6183
Specifications Japanese version
OS Windows 2000/XP 32 bit edition/Vista 32 bit edition/7 32 bit edition Japanese version
ScreenWorks-TE
TJD-6184
English version
Windows 2000/XP 32 bit edition/Vista 32 bit edition/7 32 bit edition
Screen helper 12
TJD-6854
Japanese version
Windows 2000/XP/Vista/7 32 bit edition Japanese version Excel 2003/2007/2010
*DM-12WK2B, DM-12WD4 and DM-12WK2 are scheduled for sale starting December 2015. *Windows 2000/XP/Vista/7,Windows XP Embedded,Windows Embedded Standard are the registered trademarks of U.S. Microsoft Corp.
42
Page 44
General purpose operation panel
General purpose operation panel Contributes to startup time reduction for production equipment as well as moveable efficiency improvement with an array of operation panels optimum for equipment size General purpose operation panel series ●
FP-12XXGK (12-inch display)
●
FP-07XXGS (7-inch display)
●
FP-06CGK (6-inch display)
Employs a touch panel display (excluding FP-06CGK) which directly shows the desired equipment information. High functionality operation panel with built-in support tools for all types of controllers as well as operation panel functions, with a mounted panel computer on the display.
Main features
1. Operation panel function ●
Standardly equipped with the necessary button switches and lamps for equipment operation.
●
Button switches and lamps can be added if needed.
2. PLC tool function ●
SFC, FBD and LD circuits can be displayed and monitored.
●
The safety circuit can be displayed and monitored.
●
The I/O drawing can be displayed.
●
If an error occurs, it can be tracked to each affected area using only screen operations.
3. Motion tool function ●
Present value monitor and parameter settings can be performed for MCML, MC1K, etc.
Ethernet*
General purpose operation panel PC10G
SN-I/F
*MTTR (Mean Time To Repair): The average time needed to return a faulty component or system to its proper operation *Ethernet is a registered trademark of Fuji Xerox.
43
TOYOPUC-PCS
Page 45
FP-12XXGK specification list
Type
FP-12XXGK-S1 FP-12XXGK-S2 (General equipment (Robot equipment specifications) specifications) Selection switch
○ (AUTO/MANU.)
START/ RESET START
Mounting when needed by customer (wiring only) Mounting when needed by customer (wiring only)
EXECUTE
○ ○ Mounting when needed by customer (wiring only) Mounting when needed by customer (wiring only)
○
430
Lamps
○
NONE NONE
○
NONE
○
Mounting when needed by customer (wiring only) Cream color (C17)
TJD-6100
Helper 3 2002
TJD-6101 TJD-1021
Screen mate 5
TJD-1022
Japanese
☆
English
SS1,2
Japanese
Lamps
☆
B
○
EXECUTE
○
FAULT RESET
○ ○ (with lockout mechanism) ○
GENCY S ER
R 常
FP-07XXGS
Connection ―
D
○
DOOR OPEN
○
NO PART
○
FULL PARTS
○
Paint color
Cream color (C17)
How to operate
Language
O
R
E
No symbol: Box specifications O: Open frame specifications
TJD-6854
Screen helper 7/12
TJD-6183 TJD-6184
ScreenWorks-T
Japanese Japanese
電源 W
☆
扉開き
総合異常
!
R
!
R
☆
☆
ワークなし
フルワーク
R
R
起動 リセット起動
☆
☆
W
☆
☆
W
CONT. MANU.
連続 各個
GENCY S ER
R
O
常
止
停
G
連続切 W
実行
異常 リセット
Type Series name
○
FP-06CGK
Mounting when needed by customer (wiring only)
EXECUTE
○
EMERGENCY STOP
○
Connection ―
D
D: Device network specifications IO: IO specifications
How to operate
Language
R
E
―
No symbol : Japanese E : English C : Chinese
R: Right-hand specification L : Left-hand specification
○
RETURN
Mounting when needed by customer (wiring only)
Alarm buzzer
Mounting when needed by customer (wiring only) ○
280
External drawing
External dimensions: H255×W280×D120 mm
TOYODA
電源
○
DOOR OPEN
○
GENERAL FAULT
○
START/RESET
Mounting when needed by customer (wiring only)
MASTER ON
○
Returnable
Mounting when needed by customer (wiring only)
Buzzer
Mounting when needed by customer (wiring only) Cream color (C17)
☆ 扉開き
( R)
255
Mounting when needed by customer (wiring only)
☆ 総合異常
TJD-6075 TJD-6076 TJD-1021 TJD-1022
Screen helper 2 2002 Screen mate 5
Japanese English Japanese
( R)
MASTER ON 運転準備
G
EM
FULL PARTS
( O)
GENCY S ER
自動 各個
☆
P TO
Mounting when needed by customer (wiring only)
非
NO PART
FP- 06CGK
運転中
( W)
Drawing tool
Buttons
☆
運転中 O
☆
English P TO
Lamps
☆
235
非
Others
( R)
External dimensions: H330×W235×D100 mm
START/RESET START Mounting when needed by customer (wiring only)
Paint color
PL6
( R)
No symbol : Japanese E : English C : Chinese
R: Right-hand specification L : Left-hand specification
External drawing
FP-06CGK-D-※
RUN
PL5
☆
D: Device network specifications
FP-06CGK specification list
POWER
☆
LPB1
運転準備
MASTER ON
総合異常
(O)
運転準備
Shape ―
EM
○
GENERAL FAULT
CONT. OFF
☆
☆
扉開き
MASTER ON
G 止 LPB2
停
☆
○
RUN
Selection switch (AUTO/MANU.)
☆
実行
English
PL2 運転中
☆
(W)
○
POWER
Others
Series name
○
CONT. OFF
EMERGENCY STOP (illuminated type) MASTER ON (illuminated type)
☆
PL1 電源
330
Buttons
Selection switch (CONT./MANU.) START/RESET START (Illuminated type)
PB1 EXECUTE
Type
FP-07XXGS
Drawing tool
Type
☆
☆
非
FP-07XXGS specification list
TOYODAFP-12XXGK
AUTO MANU. 自動 各個
P TO
Others
External dimensions: H430×W330×D100 mm
○
Returnable
Paint color
330
External drawing
○
GENERAL FAULT
Buzzer
R: Right-hand specification L : Left-hand specification
○ Mounting when needed by customer (wiring only) Mounting when needed by customer (wiring only)
DOOR OPEN
TEACH-IN
S1
○
RUN
Automatic robot operation
E
No symbol:machine specifications S1: General equipment specifications No MPG connector No return button No display power S2: Robot equipment specifications No MPG connector No return button No display power
FP-12XXGK: 12-inch general purpose operation panel with global compatibility, along with correspondence to emergency stop lockout
Operation power ON/OFF switch
FULL PARTS
R
○
RETURN
POWER
Specifications
No symbol : Japanese E : English C : Chinese
Mounting when needed by customer (wiring only)
EMERGENCY STOP
Language
○
○
MASTER ON
NO PART
―
How to operate
EM
Buzzer button
FP-12XXGK
○ (CONT./MANU.)
Drawing tool
Buttons
CONT. OFF
Series name
R 常
停
止
☆
☆
EXECUTE
B
☆
実 行 TY Z− ** ** EU 1−*** *
English
44
Page 46
Safety PLC
Safety PLC Conformity to the international safety standards broadens and secures workshop safety dramatically ■ Safety PLC ensures worker's safety and contributes to the productivity of a plant. ■ Better machine productivity is achieved by safety circuit visualization by Safety PLC. ■ Global standard level machine safety is realized by the international safety standards conformed safety PLC. ■ Safety PLC TOYOPUC-PCS/PCS-J series covers large-sized to small machine. ■ TOYOPUC-Plus
Safety creates the optimal safety system through decentralized layout
What is safety ? 1.View of conventional safety Safety is that an accident and disaster must not happen. To pay attention and follow correct operations strictly.
Safety control
2.View of the present safety (Europe and the U.S.) Safety is the status that "Hazard (risk) must be minimum status." To estimate equipment risk and conduct safety processing.
Risk control
What is "Risk is controlled" ?
What is the International Safety Standards ?
"Risk is controlled" means "There is no unacceptable risk"
The origin of International Safety Standards is the Machine Directive from European Union
Start
1. Machinery Directive
In EU, if someone designs, manufactures, supplies, purchases or uses a machine, must observe the Directive. (EU countries must match their lows to the Directive)
Specify the scope of target machine and specifications
Additional protection measures
Hazard identification
Estimate the Risk
Protection measures by safety protection
Evaluate the Risk
There is no unacceptable risk?
Inherently safe design
NO
YES Warning the user about residual risk
Completion
45
2. International Safety Standards about a Safety PLC
1 IEC61508 1-7 (2010)
Functional safety of electrical/electronic/ programmable electronic safety related system Safety category SIL1-4 2 IEC13849-1 (2008)
Safety of machinery Safety-related parts of control systems Performance Level a - e
A Safety PLC must conform to these two standards and acquire the certifications
Page 47
What is Safety Integrity Leve(l SIL)?(IEC 61508)
Safety PLC architecture
IEC61508 specifies SIL (Safety Integrity Level) from 1 to 4. About SIL, there are two-kinds, the low demand mode, and the high demand/continuous mode. In FA field, usually use the high demand/continuous mode. In this case, SIL is specified by PFH (average of dangerous failure rate per hour).
1. Hardware and software are redundant (Redundant configuration like A+B) 2. function (System self-diagnosis and device connection diagnosis are always implemented) 3. Mutual check (operation check between A and B ) 4. When an error detected, all outputs are shutdown instantly. Input module
CPU module
Output module
SIL
Average of dangerous failure rate per hour
Input A
CPU-A
Output A
1
10-6 ≦ × <10-5
Diagnosis
Diagnosis
Diagnosis
2
10-7 ≦ × <10-6
3
10-8 ≦ × <10-7
Mutual check
Mutual check
Mutual check
4
10-9 ≦ × <10-8
Input B
CPU-B
Output B
Diagnosis
Diagnosis
Diagnosis
Fault probablity of the dange side is once every few thousand years 24V
SIL4 is applicable for nuclear-power-station level.
24V
Basic configuration PCwin
PCwin - Sa f e 2
The same operation manners as a control PLC
TOYOPUC control PLC
TOYOPUC-PCS
TOYOPUC-PCS-J
TOYOPUC-Plus Safety
I/O signal transfer and receipt by communication
Zero wiring mistake Wirings are changed to software programming, and circuit standardization by FBD Signal transmission/reception by control PLC and communication (SN-IF)
Shorter design time and adjustment time
Function Block Digram for an emergency stop circuit Emergency stop Function
E-Stop button input
A program development by same manners as standard PLC programming Relay EDM Input (Read back)
46
Page 48
Safety PLC
TOYOPUC-PCS The Safety PLC "TOYOPUC-PCS" realized the global top level processing speed and user-friendly operations
■ The safety software circuits has been realized by the redundancy logic circuits.
■ Short
E-Stop reaction time by hi-speed processing time and space saving has been realized. ■ More reliable safety circuit program is available by fault detection function and shorten design lead time. ■ Down-sizing of safety control circuit and standardization are realized by FBD function ■ F ield wiring reduction by Safety-networking and safety signal communication. ■ M TTR improvement by employment of control visualization technology. ■ A gateway module is provided to connect TOYOPUC-PCS to various opennetworks. ■ Short-circuit protection and better noiseproofing thanks to electrical isolation by optical fiber communication
Scan and response time of TOYOPUC-PCS
High speed scanning
Realize the high speed Scan speed within a relay-circuit response time Relay circuit
TOYOPUC-PCS scanning speed
TOYOPUC-PCS
9.5ms
TOYOPUC-PCS realizes the high speed Scan speed within a relaycircuit response time
20〜30ms
High speed response
17ms response time from an emergency stop signal input to an output OFF. (stand-alone system at semiconductor output)
E-Stop button
47
Light curtain
Page 49
TOYOPUC-PCS component modules list CPU, Remote I/O module Type
Item
TAC-6089
Current, Weight 180mA, 400g S-BUS
TAU-6098
Safety communication master Current Weight RMT-S
Program method
Stored program method
2
Program control method
Cyclic operation method
3
Input/Output control method
Image resister method
4
Scanning speed
At the standalone 9.5 ms / scan
Safety communication remote satellite station Current Weight
220mA 360g
At the networking 18ms / scan
5
Program capacity
12K words (Internal memory : 64KB) (TIP-5426)
6
Memory device
・CMOS-RAM ・Flash ROM
7
Battery
Rechargeable (Lithium secondary battery : 5 years life)
8
External Input/Output
128 points
9
Internal Output
2048 points
10
Display unit
Dot-matrix LED display unit Displays are changed by MOD and INC switches
1
Physical layer
Optical fiber cable method
2
Commun. speed
6Mbps
3
Max. commun. length
100m (inter-station) 1km (Total commun. length of between stations)
4
Max. stations
24 st. (Master Slave)
16 st. (Master Slave)
All station total
5
1472 points (184 byte) = (32 Input+32 Output)×23 stations
1920 points (240 byte) = (64 Input+64 Output)×15stations
I/O points per 1 slave Input/output
32 points (4 byte) /32 points (4 byte)
64 points (8 byte) /64 points (8 byte)
155mA 150g TAU-6102
Specifications
1
Max. communication
Name CPU
6
Network topology
Ring
7
Network layer
1
8
Commun. format
HDLC flame conformity
9
Check manner
CRC-CCITT
I/O Module No Name
1 DI001
Current Weight Type
2 DI003
65mA 160kg
3 SPM002
100mA 320g
TAK-6090
TAK-6104
4 DO002
5 DO003
65mA 150g TAK-6177
55mA 320g TAK-6093
TAK-6108
FET
Device
Photo coupler
Photo coupler
Photo coupler
I/O pointsnumber
4 Sink (−common) 4 Source (+common)
12 Sink (−common) 12 Source (+common)
8 Sink (−common)
Voltage /Current
24VDC 5mA / point
24VDC 5mA / point
24VDC 5mA / point
Remarks
Dry contact points Input
Dry contact points Input
For Light curtain Inputs (−)common Input
70mA 340g
FET
Relay 2 Sink (−common) 2 Source (+common) 2 24VDC 0.25A / point
12 Sink (−common) 12 Source (+common)
24VDC 0.25A / point
3A / point Relay and FET mix Output
FET Output
Gateway module (usable for TOYOPUC-PCS, PCS-J and Plus Safety) Type TAF-6291
Gateway DeviceNet* SNGW-CL
TAF-6293
Gateway CC-Link* SNGW-PF Gateway PROFIBUS*
Item
Specifications
1
Stations
Master (TOYOPUC-PCS, PCS-J, Plus Safety) 1:1 Slave (Gateway side)
2
Physical layer
RS-485
3
Communication cable (SN-I/F)
0.5mm2 Twisted pair wires
4
Communication method
288kbps Asynchronous timing
5
Data linkage area
Bit area: Input/output=32/32 byte, Register area: Input/output=32/32 byte
TAF-6295 6
Communication byte number
Name SNGW-DL
Communication type DeviceNet
Bit
Register
Input
Output
Input
Output
Max. 32 byte
Max. 32 byte
32 byte
32 byte
PROFIBUS
Max. 32 byte
Max. 32 byte
32 byte
32 byte
CC-Link
Max. 8 byte
Max. 8 byte
Max. 32 byte
Max. 32 byte
*DeviceNet is a trademark of Open DeviceNet Vendor Association Inc. *PROFIBUS is a trademark of PROFIBUS Association.
*CC-Link is a registered trademark of Mitsubishi Electric Corporation.
48
Page 50
Safety PLC
TOYOPUC-PCS-J JTEKT, leader in the field of safety, now offers a small-sized safety PLC with ultimate user-friendliness. ■
Realize down-sizing and easier using.
■
Safety circuits visualization
■ R ealize top level program capacity and rapid compact size.
response time in
I/O built-in CPU modules
Input/output combined I/O module
Smallest configuration saving space at 75mm
The ideale I/O configuration
Smallest configuration = 2 modules (75mm)
POWER
CPU-OP(MON)
SUB MON : 8 points(input)/6 points(output) S-STP(3 types) : 6 points(input)/4 points(output)
Monitor display of the safety circuit. MTTR is dramatically reduced as circuit drawings and a tester are no longer necessary. MTTR
(index)
1
1
MTTR reduction
(Example : JTEKT machines)
0.1 Relay circuit
49
Safety PLC