For the Toyopuc THK-2750

Page 51

System component device list CPU module (I/O built-in) Part name

Model

CPU-OP (MON)

TDC-6344

1

Program method

Item Stored program method

Consumption current : 70mA Mass : 260g

2

Program control method

Cyclic computing method

3

Input/output control method

Image register method

4

Scanning speed

15ms/scan

5

Program capacity

Source program size: max 16K words (Executed program size:64KB)

6

Hold memory

7

Battery

Rechargeable (Lithium secondary battery : 5 years life)

CPU section

I/O section

Specifications

Program

Flash ROM

Safety data

No memory held

8

Maximum connection slot number

15-slot (including CPU-OP(MON))

9

External input/output points

256 points

10

Internal output points

2048 points

11

Display unit

7-seg LED display Display contents switch between MOD SW and INC SW operations

1

Input/output format

2

I/O points

3

Voltage/Current

4

Remarks

Input

Photo coupler

Output

FET 2 points Source(+common)

Input

6 points Sink(−common)

Output

6 points Source(+common)

Input

24VDC, 5mA/point

Output

24VDC, 0.5A/point

Double input 2 system(contact input×2) Double output 2 system

I/O module No Part name

1 SUB MON

Format Consumption current Input/ output format I/O point Voltage/ Current

TDK-6340 74mA Photo coupler

Photo coupler

Photo coupler

Output

FET

FET

FET

Input

2 points Source(+common) 6 points Sink(−common)

2 points Source(+common) 4 points Sink(−common)

6 points Sink(−common)

Output

6 points Source(+common)

4 points Source(+common)

4 points Source(+common)

Input

24VDC, 5mA/point

24VDC, 5mA/point

24VDC, 5mA/point

Output

24VDC, 0.5A/point

24VDC, 0.5A/point

24VDC, 0.5A/point

No Part name

Mass Remarks

200g

185g

185g

Double input 2 system (connection input×2) Double output 2 system

Double input 2 system (connection input×2) Double output 2 system

Double input 2 system (light curtain input×2) Double output 2 system

4 S-STP (E/LC)

Format Consumption current

Voltage/ Current

TDK-6347 68mA

Input

Remarks

I/O point

3 S-STP (LC)

TDK-6346 68mA

Mass

Input/ output format

2 S-STP (E)

TDK-6348 68mA

5 S-IN (E)

TDK-6356 62mA

6 S-IN (LC)

TDK-6357 62mA

7 S-OUT

TDK-6358 74mA

Input

Photo coupler

Photo coupler

Photo coupler

−

Output

FET

−

−

FET

Input

1 points Source(+common) 5 points Sink(−common)

8 points Source(+common) 8 points Sink(−common)

16 points Sink(−common)

− 16 points Source(+common)

Output

4 points Source(+common)

−

−

Input

24VDC, 5mA/point

24VDC, 5mA/point

24VDC, 5mA/point

−

Output

24VDC, 0.5A/point

−

−

24VDC, 0.3A/point

185g

190g

190g

250g

Double input 2 system (connection input×2, light curtain input×2) Double output 2 system

Double input 8 system (connection input×2)

Double inaput 8 system (light curtain input×2)

Double output 8 system

50

Page 52

Safety PLC

TOYOPUC-Plus Safety

JTEKT, who holds the No.1 Safety PLC share in Japan, offers a smart board type safety PLC ■ Creates optimal safety system by combining three types of units ■ Achieves space-saving safety system through decentralized layout

Structure of TOYOPUC-Plus Safety TOYOPUC-Plus Safety is comprised of 3 types of units.

Basic unit

Optional unit

IF unit

Example of separate placement using remote communication function of TOYOPUC-Plus Safety ■ Internal IO bus

■ Remote IO: 2,048

Expandable up to max. 128 IO points. Communication distance has total extension of 50 m. Expansion IO module can be connected to up to max. 3 units.

Expandable up to max. 2,048 IO points. Communication distance is max. 50 m between stations. It can be expanded to max. 31 stations. Up to max. 31 remote satellite stations can be connected.

Expansion IO module 3

Expansion IO module 2

Expansion IO module 1

CPU module

CPU

Remote satellite station 1

Remote satellite station 2

Remote satellite station 31

OS+BS

OS+BS

OS+BS

OS+BS+IF

(OS+BS)+(OS+BS+IF)

BS+IF

(OS+BS)+(BS+IF)

OS+BS+IF

Easy wiring-saving using communication cables Example of separate arrangement 1 (process wiring) Possible to implement OKI-PON (just put down) around the device.

Process A

Realizes wiring-saving! Expansion IO

Internal IO bus cable

Example of separate arrangement 2 (wiring between control cabinet and operation panel) Operation panel

Process B

Control cabinet Remote IO

Expansion IO CPU Occupied area reduction

Remote IO cable

Light curtain E-Stop button

51

Easy wiring between equipment using communication cables!!

IO connection to next process

Reduced amount of wiring through the installation of Plus Safety to the inside of the operation panel. Control PLC TOYOPUC-Plus + Plus Safety Control cabinet

Plus Safety Expansion IO IO connection

Internal IO bus cable

Page 53

Performance specifications No.

Item

1

Safety category

Specifications

2

Program method

Stored program method

3

Program control method

Cyclic calculation method

4

Input/Output control method

Image register method

5

Programming language

ISO13849-1

Scanning time

7

Response speed

9

9.0ms (point <= 128 points) 10.5ms (point <= 256 points)

Remote 2 (No. of remote I/O satellite stations <= 31 stations)

17.5ms (point <= 2048 points)

Stand alone (No. of remote I/O satellite stations = 0 stations)

15.8ms (point <= 128 points)

Remote 1 (No. of remote I/O satellite stations <= 3 stations)

18.8ms(point <= 256 point)

Remote 2 (No. of remote I/O satellite stations <= 31 stations)

32.8ms (point <= 2048 point)

Safety

128KB (safety + general)

General

No. of input/output points (safety + general)

128 point (Stand alone)

Dry contact point input 10

Safety

Input specifications

Photo coupler input (-) common Input current: 5mA/point Dry contact point input depending on parameter, Selection of light curtain input and semiconductor input

Light curtain input Semiconductor input

DC24V

Photo coupler input (-) common

Safety General

DC24V FET output (+) common Output current: 0.5A/point, includes no-fuse short-circuit protection function

General communication

13

Input current: 5mA/point

DC24V FET output (+) common Output current: 0.5A/point, includes no-fuse short-circuit protection function

Output specifications

12

2048 point (When using the remote)

DC24V

General

11

SIL3

Remote 1 (No. of remote I/O satellite stations <= 3 stations)

Program capacity (object size)

8

IEC61508

LD (+FBD)

Stand alone (No. of remote I/O satellite stations = 0 stations) 6

PL e

Exclusive selection of SN-I/F and MODBUS*-RTU

Internal IO bus

RS-485 3Mbps, Communication distance: total extension 50 m, LAN cable (Cat5), 8-core twisted pair cable Use shield cable for 1 m or more. Expansion IO module: Max. 3 units

Remote IO

RS-485 3Mbps, Communication distance: max. 50 m between stations Remote satellite station: max. 31 units

Expansion IO bus

14

Peripheral unit I/F (connection to PCwin-Safe 2)

15

External Memory

USB flash memory

16

General communication

RS-485 total extension 1 km; however, use double shield cable for 3 m or more. SN-I/F (communication between TOYOPUC and Safety PLC 1: 1 communication) Conforms to MODBUS*-RTU (1: N communication correspondence)

17

Indicator (displayed with 3 original colors of LED)

Module display, status display, operation selection display

18

No battery needed

USB Full Speed ( 12 Mbps)

Clock

Holds for 15 days using super capacitor.

Data backup

Backups of general register and fault history using FRAM

*"MODBUS" is a registered trademark of Schneider Automation Inc.

Unit list Without stud or screw Unit name

Name

Basic unit Safety

140

General

90

Safety

Optional unit (possible to mount 1 unit to the basic unit)

140

IF unit

140

90

General

90

Type

With stud and screw Name

Type

Specifications PNP

Function

Input

Output

CPU

Remote Expansion satellite IO station*1

Internal IO bus

Number that can be equipped with options

BS0016

TNC-6886 BS0016-01 BS0016-01

○

-

16 points

○(Motion is switched via settings) Max. 3 units

1 unit

BS0808

TNC-6887 BS0808-01 BS0808-01

○

8 points

8 points

○(Motion is switched via settings) Max. 3 units

1 unit

BS1204

TNC-6888 BS1204-01 BS1204-01

○

12 points

4 points

○(Motion is switched via settings) Max. 3 units

1 unit

BS1600

TNC-6889 BS1600-01 BS1600-01

○

16 points

-

○(Motion is switched via settings) Max. 3 units

1 unit

16 points (No. of input/output ○(Motion is switched via settings) Max. 3 units points is set by the setting tool.)

1 unit

BN16-P

TNC-6894

BN16-P-01 BN16-P-01

○

OS0016

TNK-6890 OS0016-01 OS0016-01

○

-

16 points

OS0808

TNK-6891 OS0808-01 OS0808-01

○

8 points

8 points

OS1600

TNK-6892 OS1600-01 OS1600-01

○

16 points

-

OS1200

TNK-6893 OS1200-01 OS1200-01

○

12 points

-

ON16-P

TNK-6896

ON16-P-01 ON16-P-01

○

16 points (No. of input/output points is set by the setting tool.)

Name

Type

Name

Type

Mode SW

USB IF

USB memory

SNI/F

Remote IO*1

IF0000

TNF-6898

IF0000-01

IF0000-01

○

○

○

○

○

IF00RS*2

TNF-6899

IF00RS-01

IF00RS-01

×

○

×

×

○

IF00SA

TNF-6934

IF00SA-01

IF00SA-01

○

○

○

○

×

IF00SJ

TNF-6935

IF00SJ-01

IF00SJ-01

○

○

×

○

×

Attached content of stud and screw attachment type Unit name

Attached content of stud and screw attachment type

Basic unit

Metal stud 16 mm, male-female (STD 16x4) Metal stud 16mm, male-male (ST 16x4MM) Metal stud 8mm, male-female (ST 8x4MF) Metal stud 8mm, male-male (ST 8x4MM) 1 set each

Metal stud 16mm, male-female (STD 16x4) Optional Metal stud 16mm, male-male (ST 16x4MM) unit 1 set each IF unit

Metal stud 16mm, male-female (STD 16x4) Metal stud 16mm, male-male (ST 16x4MM) Metal stud 8mm, male-female (ST 8x4MF) 1 set each

*1 It is necessary to select the IF unit that the remote IO port is mounted to. *2 IF unit only for remote satellite station.

52

Page 54

Safety PLC Power source/base/parts No

Name

Model

Specifications

1

Lithium battery

TIP-5426

CPU-OP (MON) rechargeable battery (spare parts)

2

BASE

TDR-6341

Base for connecting modules do not come with each module. sure to purchase the base also if purchasing modules other than the power module.

3

POWER

TDV-6338

Power supply module Able to supply up to 9 modules including the CPU SN-I/F ( Interface with the control PLC) USB connection (for a programmer connection)

4

BOOSTER

TDV-6339

Auxiliary power supply module Needed, when using more than 9 sets of modules including the CPU Mounting between the 9th module and the 10th module

Programming tool PCwin-Safe2 No

Name

Model

1

PCwin-Safe2 (Japanese)[CD-ROM]

TJA-2071

2

PCwin-Safe2 (English)[CD-ROM]

TJA-2073

3

PCwin-Safe2 (Chinese) [CD-ROM]

TJA-6314

4

PCwin-Safe2 (French) [CD-ROM]

TJA-6287

Specifications TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe、PCwin-Safe-J integrated environment software) [CD-ROM Japanese version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe、PCwin-Safe-J integrated environment software) [CD-ROM English version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe, PCwin-Safe-J integrated environment software) [CD-ROM Chinese version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe, PCwin-Safe-J integrated environment software) [CD-ROM French version]

Safety-related conformed standards TOYOPUC-PCS No

Conformed standards

Outline

1

IEC 61508-1-7:2002

Functional safety of Electrical/Electronic/Programmable electronics safety-related system

2

ISO 13849-1:2008

Safety of Machinery Safety related parts of control system Part 1: General principles for design

3

EN 61131-2:2000

Programmable Controllers - Part 2 : Equipment requirements and tests

4

EN 50178:1998

Electronic Equipment for use in Power Installations

5

EN 61000-2-5/IEC 61000-2-5

Electromagnetic Compatibility (EMC)

6

NFPA79:2002

Electrical Standard for Industrial Machinery(NFPA :National Fire Protection Association )

TOYOPUC-PCS-J, Plus Safety No

Conformed standards

Outline

1

IEC 61508-1-7:2002

Functional safety of Electrical/Electronic/Programmable electronics safety-related system

2

ISO 13849-1:2008

Safety of Machinery Safety related parts of control system Part 1: General principles for design

3

EN 50178:1998

Electronic Equipment for use in Power Installations

4

EN 61000-2-5/IEC 61000-2-5

Electromagnetic Compatibility (EMC)

5

NFPA79:2006

Electrical Standard for Industrial Machinery(NFPA :National Fire Protection Association )

General specifications No

TOYOPUC-PCS

TOYOPUC-PCS-J

TOYOPUC-Plus Safety

Rated : 24VDC 2.5A (tolerance : DC 21.6〜26.4V)

Voltage: 24VDC Current:Max 1A (Allowable range: DC21.6~26.V)

Power consumption

60W

24W

Voltage:24VDC Current:Max 0.3A (acceptable range:DC20.4~28.8V) 7.2W (Total value of BS unit + IF unit + OS unit)

3

Ambient temperature

0〜50℃

0〜55℃

4

Relative humidity

5

Atmosphere

Power supply

2

目

規

格

30〜85%RH (No condensation allowed)

-10~55℃ 10~95%RH(No dew accepts.)

No corrosive gas allowed

6

Vibration resistance

IEC 60068-2-6

Constant amplitude:3.5 mm(peak) Constant accelelation:9.8 m/s2(peak) Sweep:1 octave/min. 20 times in X,Y and Z directions

7

Shock resistance

IEC60068-2-27

147m/s2, 3 times in X, Y and Z directions

Noise-proof

IEC61131-2 IEC61131-6 IEC61326-3-1

Signal line : ±1kV DC power line : ±1kV Function ground line : ±1kV

8

53

項

1

Page 55

25

External dimensions

TOYOPUC-PCS

BASE5 TAR-6148 5slots

224

BASE8 TAR-6149 8slots

308

BASE12 TAR-6094 12slots 420

400

Gateway Module

100

118

25

70

178

40

100

85 BASE5 TAR-6148 5slots

224

BASE8 TAR-6149 8slots

308

120

52

BASE12 TAR-6094 12slots 420

Gateway Module

100

TOYOPUC-PCS-J S-STP (LC)

CPU-OP (MON)

BOOSTER

S-STP (E/LC)

S-OUT

SUB MON

S-IN(E)

S-STP (E)

S-IN (LC)

120

100

POWER

100mm

52

30mm

45mm

Max. 28mm

80mm

TOYOPUC-Plus Safety

16mm 16mm 16mm 1.0mm

1.6mm

1.6mm

16mm

1.6mm 97.6mm

8 mm

16mm

1.6mm 1.6mm

54

118

70

178

85

Page 56

Motion controller

Motion controller MCML/MCSSC

Motion system is best suited for multi-axis transfer and positioning Cost

Cost

Areas where works well

High speed multi-spindle assembly

Transfer Positioning Areas where works well

Feedback control High speed multi-spindle assembly Feedback control

Transfer Positioning

・Conveyor Single function ・Conveyor Single function Single function

Large scale equipment

Small scale equipment multi-spindle synchronization transfer and positioning

Large scale equipment

Small scale equipment

Single function multi-spindle synchronization transfer and positioning Item

No. of control

2

Command type

3

Control

No. of modules

8 axes/module Max. 24 (MCML/MCSSC) Max. 2 (Plus MCML/Plus MCSSC) SFC, ladder, FBD Possible to command from Plus-CPU

Position control

○

Speed control

○

Torque control

○

[Application] Workpiece transfer [Structure] X,Y example and Z 3 axes Application 1 + turning 1 axis [Application] Workpiece transfer Best suited for multi-axis [Structure] and Z 3 axes positioning X,Y control, from small to large size. + turning 1 axis Best suited for multi-axis positioning control, from small to large size. 2 Application example

Gantry loader

Gantry loader

[Application] Pallet transfer

Application example 2 [Structure] X and Y 2 axes

Motion control Max. control axes

1

Application example 1

[Application] Pallet transfer Simplified teaching makes [Structure] X even and Ywhen 2 axes setting easy eventhere is a lot of positioning information

Transfer vehicle for FMS

Simplified teaching makes setting easy even when eventhere is a lot of positioning information

Transfer vehicle for FMS

*FBD: Function Block Diagram *SFC: Sequential Function Chart

Motion system will solve the weak points of your current motions Weak point 1 Both ladder circuits and motion programs are necessary Weak point 1for motion control. Both ladder circuits and motion programs are necessary for motion control.

Weak point 2

Setting is necessary for controllers and servo Weakamps. point 2 Setting is necessary for controllers and servo amps.

Weak point 3 Numerical values are necessary for setting position. Weak point 3 Numerical values are necessary for setting position.

55

Other company PLC and motion

Other company Amplifier

Ladder circuit

Motion program Other company Amplifier

Other company PLC and motion Ladder circuit

Solution1

MCML Plus MCML MCSSC Plus MCSSC MCMLLadder circuit only Plus MCML MCSSC Plus MCSSC

Other company PLC and motion

Motion program Other company Amplifier

Other company PLC and motion

Other company Amplifier

MCML Plus MCML MCSSC Plus MCSSC

Other company PLC and motion

Other company Amplifier

MCML Plus MCML MCSSC Plus MCSSC

MCMLLadder circuit only Plus MCML MCSSC Plus MCSSC

1253.5 setup MCML Other company Position Otherdata company Plus MCML PLC and motion Amplifier

MCSSC Plus MCSSC

Position data 1253.5 setup

Easy designing

Motion control can be realized just by using control circuits. Simpler PLC circuits due to an introduction of the function blocks. Motion control circuits using SFC allows movement of designing Solution1 equipment to beEasy expressed simpler and easier to-understand. Also, the movement can be changed with ease. Motion control can be realized just by using control circuits. Simpler PLC circuits due to an introduction of the function blocks. Motion control circuits using SFC allows movement of equipment to be expressed simpler and easier to-understand. Also, the movement be changed with ease. Easycan setup

Solution2

All setup can be carried out on an operation panel (or peripheral tools). No need to switch computer specialty application tools or cables.

Solution2

Easy setup

All setup can be carried out on an operation panel (or peripheral tools). No need to switch computer specialty application tools or cables.

Solution3

Capture

Capture

Easy teaching

Thanks to the easy teaching function, just operate and press the read button. Current location can be easily set to a target location in one go.

Solution3

Easy teaching

Thanks to the easy teaching function, just operate and press the read button. Current location can be easily set to a target location in one go.

Page 57

Realizes motion control only using ladder circuits. In addition to this feature, being able to control with SFC and FBD allows you to design more easily. PLC

Setting up controller in link parameters

MCML/Plus MCML/MCSSC/Plus MCSSC MCML Plus MCML MCSSC Plus MCSSC

PLC

Instructs movement in SFC (ladder)

Position

Parameter

Order of movement can be seen at a glance circuit in question

Condition un-match can be known

Number Command place Feed speed POS1 PCOM 0043107 FEED 0040000 ・ ・ ・

Position setting Positioning FB

POS1 movement

Data held by the controller

POS1 POS2 movement Command sending Positioning completion

・At a glance where the equipment stops ・You can locate a cause of trouble on a screen with ease

Function block for MCML control reduces design processes

Step execution complete flag (Select one of these)

When the equipment stops

No personal computers are necessary for setting up systems. Easy setup from operation panel. It is easy to set up motion from operation panel. Operation panel

Manual pulse*1 generator

Servo amplifier

MCML Plus MCML MCSSC Plus MCSSC

Servo motor *1 MCML and MCSSC require [high speed counter] or [CT10].

It is easy to monitor motors; teaching of target position setting is also easily carried out through operation panel screens. By operating in JOG mode or with a manual pulse generator, teaching can be done in one go. Reading and modification of positioning information is possible

Move position with JOG operation from the operation panel It is possible to read current value information with the "read" button

Functions No. of control axes Control mode Encoder method Positioning control

Position command

Speed command Acceleration / deceleration setting Setup data

Positioning method No. of points Position command unit Command setting unit

Linear axis position command range

Speed command unit Speed command range Acceleration / deceleration processing Acceleration / deceleration setting range Positioning control Position output Control mode

Stroke Method Speed Compensation function Others

Communication

Supported PLC Motion setting tool

MCML

Plus MCML

MCSSC Plus MCSSC 1-8 axes Positioning control Speed control Torque control Absolute type PTP control (each axis independent movement) 700 points / axis, max. 5600 points (700x8 axes) mm, deg Can be set up by parameters from decimal 0 to 5 digits -2147483647 ~ 2147483647 -214748364. 7 ~ 214748364. 7 -21474836. 47 ~ 21474836. 47 -2147483. 647 ~ 2147483. 647 -214748. 3647 ~ 214748. 3647 -21474. 83647 ~ 21474. 83647 mm/s, mm/min, deg/s, deg/min mm/s, deg/s 0 ~ 2091752000 Trapezoid acceleration / deceleration (setting can be made per acceleration/deceleration. 2-step changeable) 1 ~ 65535 Setting data (700 points/axis) position output data (16 points/axis) Parameter (for controller and servo amplifier) 65536 rotations MECHATROLINK-Ⅲ* SSCNETⅢ* 100Mbps 50Mbps Index position compensation function Unlimited long rotation function (endless operation function) / Jog feed function / Current restraint function TOYOPUC-PC10G, PC10P, TOYOPUC-PC10G, PC10P, PC3JX・PC3JX-D, PC3J, TOYOPUC-Plus CPU PC3JX・PC3JX-D, PC3J, TOYOPUC-Plus CPU PC3JL, PC3JD, PC3JG PC3JL, PC3JD, PC3JG Motion Tool

*MECHATROLINK is a registered trademark of MECHATROLINK Association. *SSCNET is a registered trademark of Mitsubishi Electric Corporation.

56

Page 58

Device list TOYOPUC-PC10G/PC3J Device

Name

PC10G

PC10G-CPU

PC10P

PC10P

Specification Memory 180K words (60K×3), FL-net/Ethernet*/FL remote (selected by a parameter) 2port, SN-1/F/PC-LINK/CMP-LINK (selected by a parameter) built-in 1port, peripheral port available for USB2.0 Memory 180K words (60K word x3), PCI bus, USB port for a peripheral device (PCwin) communication USB port for TOYOPUC BUS-EXP (EXPANSION BUS) communication, FL-net/Ethernet*/FL remote 2 ports

FL remote I/O board FL remote I/O board Dedicated PC10P expansion module PC3JX

PC3J CPU module

FL remote I/O PNP Input/output 40/40

Connecter terminal block

TCC-6353

○

○

TCC-6372

○

○

TCU-6421

○

○

One set: 1 unit for input 50 pins and 1 unit for output 60 pins

TRS-5104

USB port for PC10P communication

SN-I/F, PC-LINK, CMP-LINK 1 port

TCU-6367

○

○

PlusBUS-EX

Special expansion module for PC10P. Supports use of Plus series options

TCU-6900

○

○

*

PC3JX-CPU

Memory: 48K words (16K words×3) PC/CMP/SN-IF/MODBUS/SIO(2 ports)

TCC-6901

○

○

PC3JX-D-CPU

Memory: 48K words (16K words×3) PC/CMP/SN-IF/MODBUS/SIO(2 ports) DeviceNet* (1 port)

TCC-6902

○

○

PC3J-CPU

Memory 48K-word(16K×3)+PC/CMP, 3 programs available

TIC-5339

○

CPU built-in option PC-link or CMP-link is available

TIU-5366

Memory 48K-word(16K×3)+PC/CMP(2port), 3 programs available

TIC-5783

○

TIC-6088

○

○

*

TIC-6125

○

○

*

Option

PC3J-CPU PC/CMP

PC3JL-CPU

Memory 180K-word(60K×3) Input(-) common32points (5mA),output(+) common16points (0.3A)+output(+) common16points (0.05A), SN-I/F, PC, CMP(1port), DLNK-M2 function Memory 48K-word(16K×3) Input(+) common32points (5mA),output(-) common16points (0.3A)+output(-) common16points (0.05A), SN-I/F, PC, CMP(1port), DLNK-M2 function

PC3JG-P-CPU PC3JG-CPU

Selector module

CSA/UL CE

BUS-EXP (EXPANDED BUS)

PC3JG

Power module

Type

* * *

POWER1

Input 85-264VAC, Output 5VDC 4A

THV-2747

POWER2H

Input DC24V Output DC5V 5A

THV-6374

○

○

SELECTOR

For setting of rack No. and I/O address

THU-2765

○

○

For mounting CPU or selector,

Base

Selector base

I/O cable

8 slot base

8 miseellaneous modules, 1 I/O connector

THR-2766

○

○

8 slot base (2)

8 miseellaneous modules, 2 I/O connectors

THR-2872

○

○

6 slot base

6 miseellaneous modules, 1 I/O connector

THR-2813

○

○

4 slot base

4 miseellaneous modules, 1 I/O connector

THR-2775

○

○

2 slot base

2 miseellaneous modules, 1 I/O connector

THR-2814

○

○

8-slot selector base

Base only for 8-slot expansion with built-in selector function, 2 I/O connectors

THR-5643

○

○

6-slot selector base

Base only for 6-slot expansion with built-in selector function, 2 I/O connectors

THR-5644

○

○

4-slot selector base

Base only for 4-slot expansion with built-in selector function, 2 I/O connectors

THR-5645

○

○

I/O cable 0.5m

For connection between a CPU base or I/O base and another I/O base:0.5m

THY-2770

○

I/O cable 1m

For connection between a CPU base or I/O base and another I/O base:1m

THY-2771

○

I/O cable 1.5m

For connection between a CPU base or I/O base and another I/O base:1.5m

THY-5146

○

*

I/O cable 2m

For connection between a CPU base or I/O base and another I/O base:2m

THY-5045

○

*

I/O cable 2.5m

For connection between a CPU base or I/O base and another I/O base:2.5m

THY-5689

○

*

I/O cable 3m

For connection between a CPU base or I/O base and another I/O base:3m

THY-2995

○

*

For connection of 3 or more beses

THU-2774

○

100VAC input, 16 points

THK-2749

I/O branch module IN-11 Input

Input/Output module Output

Input/Output

Flat cable for I/O-329G

Unit for I/O-329

IN-12

24VDC input, 16 points

THK-2750

○

○

IN-22D

24VDC input, 32 points

THK-2871

○

○

IN-22H

24VDC input, 32 points, high speed input, free screw terminal stand

THK-6831

○

○

IN-SW

Switch input, 16 points

THK-5977

○

○

OUT-1

Triac output 8 points, 1A/points, 4A/8 points, 100-115VAC

THK-2751

OUT-3

Independent relay contact 8 points (240VAC/24VDC), 2A/point

THK-2931

OUT-11

Triac output 16 points, 0.5A/point, 2A/8 point, 100-115VAC

THK-2795

OUT-12

Relay contact output 16 points, 2A/point, 5A/8 points (240VAC/24VDC)

THK-2752

○

OUT-15

MOS FET output (-) common, 16 points, 1A/point, 4A/8 points

THK-2790

○

○ ○ ○

OUT-16

MOS FET output (+) common, 16 points, 1A/point, 4A/8 points

THK-2791

○

○

OUT-18

Transister output (-) common, 16 points, 0.5A/point, 2A/8 points

THK-2753

○

○

OUT-19

Transister output (+) common, 16 points, 0.5A/point, 2A/8 points

THK-2754

○

○

OUT-28D

Transister output (-) common, 32 points, 0.2A/point, 2A/16 points

THK-2870

○

○ ○

OUT-29D

Transister output (+) common, 32 points, 0.2A/point, 2A/16 points

THK-5025

○

I/O-328G

Input 32 points (5mA), Output 16 points (0.3A) + Output 16 points (0.05A) (-) common

THK-6905

○

○

I/O-329G

Input 32 points (5mA), Output 16 points (0.3A) + Output 16 points (0.05A) (+) common

THK-6410

○

○

IO 2 - 004M

Flat cable 0.4m

TXY-6573

○

*

IO 2 - 010M

Flat cable 1.0m

TXY-6576

○

*

IO 2 - 016M

Flat cable 1.6m

TXY-6579

○

*

IO 2 - 022M

Flat cable 2.2m

TXY-6583

○

*

IO 2 - 030M

Flat cable 3.0m

TXY-6587

○

*

Connector conversion unit

40P flat cable → conversion of non-screw terminal block

TXU-6086

*

*Produced on special order ● Products circled in the CSA/UL column are qualified products by CSA.

Products marked "UL" are qualified products by UL.

● ○ Marked at CE column are CE approved products. ● *Marked at the column are oder-made products.

57

Please ask detail delivery when you order.

Page 59

Device

Name

Communication module

Specification

Type

Multi-link

ML10

Supports PC/CMP (Supports 2-wire and 4-wire), M-NET, SIO and MODBUS*

TCU-6903

○

High-speed PC link

HPC-LINK

625kbps, 32 station, 2,048 points, 1,792 bytes

THU-2758

○

2PORT FL/ET/RMT

2PORT-EFR

FL-net/Ethernet/FL remote (2port)

THU-6404

○

○

FL-net Ethernet

FL/ET-T-V2H

FL-net (version2), Ethernet interface

THU-6289

○

○

Highspeed remote I/O

Master

RMT-I/O M

Master station, 625kbps Max. 31 satellites

THU-2756

○

Satellite

RMT-I/O S

Satellite

THU-2757

○

DLNK-M2

Master station, 500/250/125kbps, 63 stations, 4,096 points

THU-6099

○

○

DLNK-S

Satellite, I/O terminal type, 500/250/125kbps, 512 points

THU-5441

○

○

DLNK-S2

Satellite, between-PC link type, 500/250/125 kbps, input and output 512 points respectively

THU-5563

○

○

SC10

RS-232C,

TCU-6904

○

○

CT10

200kpps (PC input) 8Mpps (differential input)

AD-10

−10〜10V, 0〜10V, 0〜5V,1〜5V, 0〜20mA, 4〜20mA

TCK-6529

○

○

Analogue output

DA-1

1−5V, 4−20mA 2 points

THK-7931

○

○

DA-2

0−10V 2 points

THK-7932

○

○

PULSE output

PULSE OUT

Pulse output 1-axis easy positioning

THK-5109

Motion controller

MCML

Max. 8-axis positioning, MECHATROLINK-Ⅲ*

TCI-6721

○

○

MCSSC

Max. 8-axis positioning, SSCNETⅢ*

TCI-6805

○

○

DeviceNet*

Serial I/O High-speed counter Analogue input Special module

0.3〜115.2kbps,

2ch

CSA/UL CE

*

○

TCK-6856 8 points

*

*Produced on special order

Parts Device

Name

Lithium battery Connector

Specification

Type

For PC10/PC3J-CPU

For TOYOPUC-PC10/PC3J/MX/PCS/PCS-J CPU, Coin-type secondary cell

T I P-5426

For CPU

For TOYOPUC-PC2/PC2J/L2 CPU, PC2FS

TXP-2789

External connector for PC3JG and I/O-329G

A 40-pin square shape connector of soldering type (with a 40-pin resin enclosure)

T I P-5867

CSA/UL CE

*

CSA/UL CE

*

TOYOPUC-PCk Device

Name

TKC-6471

UL

○

PCk06-P-CPU

Program capacity 7,679 words Input: Built-in 20 points Output: Built-in 16 points (source output)

TKC-6472

UL

○

Input

Communication module

Type

PCk05-CPU CPU

Input/output module

Specification Program capacity 2,048 words Input: Built-in 8 points Output: Built-in 6 points (relay output)

IN-k93

Input (10 points, DC12-24V)

TKK-6473

UL

○

IN-k14

Input (16 points, DC20-28V)

TKK-6474

UL

○ ○

OUT-k12

Output (16 points, DC12-24V, source)

TKK-6475

UL

OUT-k81

Relay output (8 points, DC6-27V, AC6-240V)

TKK-6478

UL

○

Input-output

I/O-k831

Input-output (input 4 points DC12-24V, relay output 3 point )

TKK-6476

UL

○

Device net Slave kDLNK

Device net Slave

TKU-6477

Connector with a cable for a 16-point modules 1m

TKY-6486

Output

Connector with a cable

TOYOPUC-PC3JT Device

Name PC3JT-CPU

CPU

Communication

Input/Output module FL-net, Ethernet

Specification

Type

CSA/UL CE

Memory 48K-word(16K×3), CX/CMP link and PC/CMP link built-in

TIC-5994

○

Option

DLNK

Master station, 500/250/125kbps, 63 stations, 2,048 points

TIU-5996

○

Option

AS-i M

AS-i I/F

TIU-6026

○

PC3JT-I/O(+)

16 points DC24V input 16 points MOS-FET output(+) common,0.1A/point, 1A/16 points

TIU-6212

○

PC3JT-I/O(-)

16 points DC24V input 16 points MOS-FET output(-) common,0.1A/point, 1A/16 points

TIU-6213

○

PC3JT-FL/ET-V2

FL-net I/F, Ethernet I/F

TIU-6021

○

High-speed PC link High-speed remote I/O

PC3JT-HPC

PC link : 625 kbps, 32 stations, 2048 points, 1792 bytes, 1 : N communication. Remote I/O : Master station 625kbps, 2048 points, selection of max. 31satellites, built in 2 port

TIU-6022

○

S-LINK

*

PC3JT-S-LINK

S-LINK interface made by Sunx

TIU-6025

○

Special Serial I/O

PC3JT-SIO

RS-232C, 0.3−19.2Kbps, 2ch

TIU-6024

○

Cover

PC3JT cover

The cover for PC3JT

TIU-6027

Base

PC3JT base2

The base for PC3JT

TIU-6146

*

*DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc. *AS-i is an open network of AS-international (AS-i association). *MECHATROLINK is a registered trademark of MECHATROLINK Association. *SSCNET is a registered trademark of Mitsubishi Electric Corporation. *Ethernet is a registered trademark of Fuji Xerox. *MODBUS is a registered trademark of AEG Schneider Automation Inc.

58

Page 60

Device list PCDL Device

Name

CPU

PCDL

AC power supply base Base module DC power supply base

DC input Input/ Output module

DC output

AC output

Analogue module

Programmer

Type

CSA/UL

CE

TKC-6688

UL

○

D2-03B-1J

2 module base (AC power supply)

TKR-6689

UL

○

D2-04B-1J

3 module base (AC power supply)

TKR-6690

UL

○

D2-06B-1J

5 module base (AC power supply)

TKR-6691

UL

○

D2-09B-1J

8 module base (AC power supply)

TKR-6692

UL

○

D2-03BDC1-1J

2 module base (DC power supply)

TKR-6693

UL

○

D2-04BDC1-1J

3 module base (DC power supply)

TKR-6694

UL

○

D2-06BDC1-1J

5 module base (DC power supply)

TKR-6695

UL

○

D2-09BDC1-1J

8 module base (DC power supply)

TKR-6696

UL

○

D2-08ND3

8 points DC12/24V (+/-)common

TKK-6697

UL

○

D2-16ND3-3J

16 points DC24V (+/-)common

TKK-6698

UL

○

D2-32ND3

32points DC24V (+/-)common (connector type)

TKK-6718

UL

○

D2-08TD2

8 points Open collector output DC12/24V (+) common

TKK-6699

UL

○

UL

D2-16TD2-3J

16 points Open collector output DC12/24V (+) common

TKK-6700

D2-32TD2

32 points Open collector output DC12/24V (+) common (connector type)

TKK-6719

*

○ ○

D2-08TA

8 points SSR output AC100V/200V

TKK-6701

UL

○

Analogue input

Current input

F2-08AD-1

8ch/common, 4~20mA

TKK-6705

UL

○

Voltage input

F2-08AD-2

8ch/common, 0~5V/0~10V/±5V/±10V

TKK-6706

UL

○

Analogue output

Current output

F2-08DA-1

8ch, single end, 4-20mA

TKK-6707

UL

○

Voltage output

F2-08DA-2

8ch, single end, 0-5V/0-10V

TKK-6708

UL

○

D2-02RM

M-NET specifications (8 stations, 256 points)

TKU-6728

UL

○

Communication M-NET module CUnet Other modules

Specification Memory 16K words Built-in communication (Slave) I/F:RS232C(PCwin)/MODBUS*-RTU L1:FL-net * L2 : CMP-LINK/MODBUS -RTU (Slave) / Serial I/O(SIO) /PC-LINK/SN-I/F

D2-HSIO

CUnet specifications(64 stations, 4096 points)

TKU-6832

Expansion controller

D2-CM

Mounted on a base module CPU slot.

TKU-6702

UL

○

Expansion controller

D2-EM

Mounted at the right side of a base module.

TKU-6703

UL

○

Dummy panel

D2-FILL

Covering for empty slots

TKU-6704

Programming tool

PCwin (Ver.12 or more)

PC10/3/2/1 series・MX・PCDL Programmer

TJA-2032

Connecting cable

PCk connecting cable

D-SUB 9P⇔RJ12 conversion connector and RJ12⇔RJ12 Programmer connecting cable (2m) set

TKY-6485

Specification

Type

16K/48K words, Ethernet* / FL-net / FL Remote (selected by a parameter) 1port, PC/CMP/SIO/MODBUS* 1port, peripheral port available for USB2.0

TCC-6740

○

○

TCU-6741

○

○

TCU-6858

○

○

○

○

○

○

TOYOPUC-Plus Device CPU

Name Plus CPU

CSA/UL CE

Plus expansion mode (enabled when EX board is implemented) Ethernet* / FL-net / FL Remote 10Mbps / 100Mbps, EtherCAT* 100Mbps

Plus EX

PC / CMP / SIO (RS422 / RS232C) / SN- I / F / MODBUS* Additional functions

Plus expansion mode (enabled when EX2 board is implemented) Ethernet* / FL-net/FL Remote / EtherNetIP 10Mbps/100Mbps, EtherCAT* 100Mbps

Plus EX2

PC/CMP/SIO (RS422/RS232C) /SN-I/F/MODBUS

*

Communication

Motion

Input/output

Plus EFR

Etherne*t / FL-net / FL Remote 10Mbps / 100Mbps, EtherCAT* 100Mbps

TCU-6743

Plus EFR2

Ethernet* / FL-net/FL Remote / EtherNetIP 10Mbps/100Mbps, EtherCAT* 100Mbps

TCU-6859

Plus DLNK-M

DeviceNet master

TCU-6744

Plus CLNK-M

CC Link* master Ver 2.00 compatible

TCU-6824

Plus CLNK-S

CC Link* slave Ver 2.00 compatible

TCU-6830

○

○

Plus MCML

Positioning / torque / speed control max. 8-axis MECHATROLINK-III*

TCI-6819

○

○

Plus MCSSC

Positioning / torque / speed control max. 8-axis SSCNETⅢ*

TCI-6884 ○

○

*

24 inputs (5mA/24V, (-) common)

Plus IO24/16P

16 outputs (0.5A/24V, (+) common)

Cover

Plus cover

Cover for Plus

Bracket

BRA-DIN

Bracket mounting the DIN rail for Plus

● Products circled in the CSA/UL column are qualified products by CSA.

Products marked "UL" are qualified products by UL.

● ○ Marked at CE column are CE approved products. ● *Marked at the column are oder-made products.

59

Please ask detail delivery when you order.

TCU-6742 TCU-6779

*