System component device list CPU module (I/O built-in) Part name
Model
CPU-OP (MON)
TDC-6344
1
Program method
Item Stored program method
Consumption current : 70mA Mass : 260g
2
Program control method
Cyclic computing method
3
Input/output control method
Image register method
4
Scanning speed
15ms/scan
5
Program capacity
Source program size: max 16K words (Executed program size:64KB)
6
Hold memory
7
Battery
Rechargeable (Lithium secondary battery : 5 years life)
CPU section
I/O section
Specifications
Program
Flash ROM
Safety data
No memory held
8
Maximum connection slot number
15-slot (including CPU-OP(MON))
9
External input/output points
256 points
10
Internal output points
2048 points
11
Display unit
7-seg LED display Display contents switch between MOD SW and INC SW operations
1
Input/output format
2
I/O points
3
Voltage/Current
4
Remarks
Input
Photo coupler
Output
FET 2 points Source(+common)
Input
6 points Sink(−common)
Output
6 points Source(+common)
Input
24VDC, 5mA/point
Output
24VDC, 0.5A/point
Double input 2 system(contact input×2) Double output 2 system
I/O module No Part name
1 SUB MON
Format Consumption current Input/ output format I/O point Voltage/ Current
TDK-6340 74mA Photo coupler
Photo coupler
Photo coupler
Output
FET
FET
FET
Input
2 points Source(+common) 6 points Sink(−common)
2 points Source(+common) 4 points Sink(−common)
6 points Sink(−common)
Output
6 points Source(+common)
4 points Source(+common)
4 points Source(+common)
Input
24VDC, 5mA/point
24VDC, 5mA/point
24VDC, 5mA/point
Output
24VDC, 0.5A/point
24VDC, 0.5A/point
24VDC, 0.5A/point
No Part name
Mass Remarks
200g
185g
185g
Double input 2 system (connection input×2) Double output 2 system
Double input 2 system (connection input×2) Double output 2 system
Double input 2 system (light curtain input×2) Double output 2 system
4 S-STP (E/LC)
Format Consumption current
Voltage/ Current
TDK-6347 68mA
Input
Remarks
I/O point
3 S-STP (LC)
TDK-6346 68mA
Mass
Input/ output format
2 S-STP (E)
TDK-6348 68mA
5 S-IN (E)
TDK-6356 62mA
6 S-IN (LC)
TDK-6357 62mA
7 S-OUT
TDK-6358 74mA
Input
Photo coupler
Photo coupler
Photo coupler
−
Output
FET
−
−
FET
Input
1 points Source(+common) 5 points Sink(−common)
8 points Source(+common) 8 points Sink(−common)
16 points Sink(−common)
− 16 points Source(+common)
Output
4 points Source(+common)
−
−
Input
24VDC, 5mA/point
24VDC, 5mA/point
24VDC, 5mA/point
−
Output
24VDC, 0.5A/point
−
−
24VDC, 0.3A/point
185g
190g
190g
250g
Double input 2 system (connection input×2, light curtain input×2) Double output 2 system
Double input 8 system (connection input×2)
Double inaput 8 system (light curtain input×2)
Double output 8 system
50
Page 52
Safety PLC
TOYOPUC-Plus Safety
JTEKT, who holds the No.1 Safety PLC share in Japan, offers a smart board type safety PLC ■ Creates optimal safety system by combining three types of units ■ Achieves space-saving safety system through decentralized layout
Structure of TOYOPUC-Plus Safety TOYOPUC-Plus Safety is comprised of 3 types of units.
Basic unit
Optional unit
IF unit
Example of separate placement using remote communication function of TOYOPUC-Plus Safety ■ Internal IO bus
■ Remote IO: 2,048
Expandable up to max. 128 IO points. Communication distance has total extension of 50 m. Expansion IO module can be connected to up to max. 3 units.
Expandable up to max. 2,048 IO points. Communication distance is max. 50 m between stations. It can be expanded to max. 31 stations. Up to max. 31 remote satellite stations can be connected.
Expansion IO module 3
Expansion IO module 2
Expansion IO module 1
CPU module
CPU
Remote satellite station 1
Remote satellite station 2
Remote satellite station 31
OS+BS
OS+BS
OS+BS
OS+BS+IF
(OS+BS)+(OS+BS+IF)
BS+IF
(OS+BS)+(BS+IF)
OS+BS+IF
Easy wiring-saving using communication cables Example of separate arrangement 1 (process wiring) Possible to implement OKI-PON (just put down) around the device.
Process A
Realizes wiring-saving! Expansion IO
Internal IO bus cable
Example of separate arrangement 2 (wiring between control cabinet and operation panel) Operation panel
Process B
Control cabinet Remote IO
Expansion IO CPU Occupied area reduction
Remote IO cable
Light curtain E-Stop button
51
Easy wiring between equipment using communication cables!!
IO connection to next process
Reduced amount of wiring through the installation of Plus Safety to the inside of the operation panel. Control PLC TOYOPUC-Plus + Plus Safety Control cabinet
Plus Safety Expansion IO IO connection
Internal IO bus cable
Page 53
Performance specifications No.
Item
1
Safety category
Specifications
2
Program method
Stored program method
3
Program control method
Cyclic calculation method
4
Input/Output control method
Image register method
5
Programming language
ISO13849-1
Scanning time
7
Response speed
9
9.0ms (point <= 128 points) 10.5ms (point <= 256 points)
Remote 2 (No. of remote I/O satellite stations <= 31 stations)
17.5ms (point <= 2048 points)
Stand alone (No. of remote I/O satellite stations = 0 stations)
15.8ms (point <= 128 points)
Remote 1 (No. of remote I/O satellite stations <= 3 stations)
18.8ms(point <= 256 point)
Remote 2 (No. of remote I/O satellite stations <= 31 stations)
32.8ms (point <= 2048 point)
Safety
128KB (safety + general)
General
No. of input/output points (safety + general)
128 point (Stand alone)
Dry contact point input 10
Safety
Input specifications
Photo coupler input (-) common Input current: 5mA/point Dry contact point input depending on parameter, Selection of light curtain input and semiconductor input
Light curtain input Semiconductor input
DC24V
Photo coupler input (-) common
Safety General
DC24V FET output (+) common Output current: 0.5A/point, includes no-fuse short-circuit protection function
General communication
13
Input current: 5mA/point
DC24V FET output (+) common Output current: 0.5A/point, includes no-fuse short-circuit protection function
Output specifications
12
2048 point (When using the remote)
DC24V
General
11
SIL3
Remote 1 (No. of remote I/O satellite stations <= 3 stations)
Program capacity (object size)
8
IEC61508
LD (+FBD)
Stand alone (No. of remote I/O satellite stations = 0 stations) 6
PL e
Exclusive selection of SN-I/F and MODBUS*-RTU
Internal IO bus
RS-485 3Mbps, Communication distance: total extension 50 m, LAN cable (Cat5), 8-core twisted pair cable Use shield cable for 1 m or more. Expansion IO module: Max. 3 units
Remote IO
RS-485 3Mbps, Communication distance: max. 50 m between stations Remote satellite station: max. 31 units
Expansion IO bus
14
Peripheral unit I/F (connection to PCwin-Safe 2)
15
External Memory
USB flash memory
16
General communication
RS-485 total extension 1 km; however, use double shield cable for 3 m or more. SN-I/F (communication between TOYOPUC and Safety PLC 1: 1 communication) Conforms to MODBUS*-RTU (1: N communication correspondence)
17
Indicator (displayed with 3 original colors of LED)
Module display, status display, operation selection display
18
No battery needed
USB Full Speed ( 12 Mbps)
Clock
Holds for 15 days using super capacitor.
Data backup
Backups of general register and fault history using FRAM
*"MODBUS" is a registered trademark of Schneider Automation Inc.
Unit list Without stud or screw Unit name
Name
Basic unit Safety
140
General
90
Safety
Optional unit (possible to mount 1 unit to the basic unit)
140
IF unit
140
90
General
90
Type
With stud and screw Name
Type
Specifications PNP
Function
Input
Output
CPU
Remote Expansion satellite IO station*1
Internal IO bus
Number that can be equipped with options
BS0016
TNC-6886 BS0016-01 BS0016-01
○
-
16 points
○(Motion is switched via settings) Max. 3 units
1 unit
BS0808
TNC-6887 BS0808-01 BS0808-01
○
8 points
8 points
○(Motion is switched via settings) Max. 3 units
1 unit
BS1204
TNC-6888 BS1204-01 BS1204-01
○
12 points
4 points
○(Motion is switched via settings) Max. 3 units
1 unit
BS1600
TNC-6889 BS1600-01 BS1600-01
○
16 points
-
○(Motion is switched via settings) Max. 3 units
1 unit
16 points (No. of input/output ○(Motion is switched via settings) Max. 3 units points is set by the setting tool.)
1 unit
BN16-P
TNC-6894
BN16-P-01 BN16-P-01
○
OS0016
TNK-6890 OS0016-01 OS0016-01
○
-
16 points
OS0808
TNK-6891 OS0808-01 OS0808-01
○
8 points
8 points
OS1600
TNK-6892 OS1600-01 OS1600-01
○
16 points
-
OS1200
TNK-6893 OS1200-01 OS1200-01
○
12 points
-
ON16-P
TNK-6896
ON16-P-01 ON16-P-01
○
16 points (No. of input/output points is set by the setting tool.)
Name
Type
Name
Type
Mode SW
USB IF
USB memory
SNI/F
Remote IO*1
IF0000
TNF-6898
IF0000-01
IF0000-01
○
○
○
○
○
IF00RS*2
TNF-6899
IF00RS-01
IF00RS-01
×
○
×
×
○
IF00SA
TNF-6934
IF00SA-01
IF00SA-01
○
○
○
○
×
IF00SJ
TNF-6935
IF00SJ-01
IF00SJ-01
○
○
×
○
×
Attached content of stud and screw attachment type Unit name
Attached content of stud and screw attachment type
Basic unit
Metal stud 16 mm, male-female (STD 16x4) Metal stud 16mm, male-male (ST 16x4MM) Metal stud 8mm, male-female (ST 8x4MF) Metal stud 8mm, male-male (ST 8x4MM) 1 set each
Metal stud 16mm, male-female (STD 16x4) Optional Metal stud 16mm, male-male (ST 16x4MM) unit 1 set each IF unit
Metal stud 16mm, male-female (STD 16x4) Metal stud 16mm, male-male (ST 16x4MM) Metal stud 8mm, male-female (ST 8x4MF) 1 set each
*1 It is necessary to select the IF unit that the remote IO port is mounted to. *2 IF unit only for remote satellite station.
52
Page 54
Safety PLC Power source/base/parts No
Name
Model
Specifications
1
Lithium battery
TIP-5426
CPU-OP (MON) rechargeable battery (spare parts)
2
BASE
TDR-6341
Base for connecting modules do not come with each module. sure to purchase the base also if purchasing modules other than the power module.
3
POWER
TDV-6338
Power supply module Able to supply up to 9 modules including the CPU SN-I/F ( Interface with the control PLC) USB connection (for a programmer connection)
4
BOOSTER
TDV-6339
Auxiliary power supply module Needed, when using more than 9 sets of modules including the CPU Mounting between the 9th module and the 10th module
Programming tool PCwin-Safe2 No
Name
Model
1
PCwin-Safe2 (Japanese)[CD-ROM]
TJA-2071
2
PCwin-Safe2 (English)[CD-ROM]
TJA-2073
3
PCwin-Safe2 (Chinese) [CD-ROM]
TJA-6314
4
PCwin-Safe2 (French) [CD-ROM]
TJA-6287
Specifications TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe、PCwin-Safe-J integrated environment software) [CD-ROM Japanese version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe、PCwin-Safe-J integrated environment software) [CD-ROM English version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe, PCwin-Safe-J integrated environment software) [CD-ROM Chinese version] TOYOPUC-PCS/PCS-J/Plus Safety programming software (PCwin-Safe, PCwin-Safe-J integrated environment software) [CD-ROM French version]
Safety-related conformed standards TOYOPUC-PCS No
Conformed standards
Outline
1
IEC 61508-1-7:2002
Functional safety of Electrical/Electronic/Programmable electronics safety-related system
2
ISO 13849-1:2008
Safety of Machinery Safety related parts of control system Part 1: General principles for design
3
EN 61131-2:2000
Programmable Controllers - Part 2 : Equipment requirements and tests
4
EN 50178:1998
Electronic Equipment for use in Power Installations
5
EN 61000-2-5/IEC 61000-2-5
Electromagnetic Compatibility (EMC)
6
NFPA79:2002
Electrical Standard for Industrial Machinery(NFPA :National Fire Protection Association )
TOYOPUC-PCS-J, Plus Safety No
Conformed standards
Outline
1
IEC 61508-1-7:2002
Functional safety of Electrical/Electronic/Programmable electronics safety-related system
2
ISO 13849-1:2008
Safety of Machinery Safety related parts of control system Part 1: General principles for design
3
EN 50178:1998
Electronic Equipment for use in Power Installations
4
EN 61000-2-5/IEC 61000-2-5
Electromagnetic Compatibility (EMC)
5
NFPA79:2006
Electrical Standard for Industrial Machinery(NFPA :National Fire Protection Association )
General specifications No
TOYOPUC-PCS
TOYOPUC-PCS-J
TOYOPUC-Plus Safety
Rated : 24VDC 2.5A (tolerance : DC 21.6〜26.4V)
Voltage: 24VDC Current:Max 1A (Allowable range: DC21.6~26.V)
Power consumption
60W
24W
Voltage:24VDC Current:Max 0.3A (acceptable range:DC20.4~28.8V) 7.2W (Total value of BS unit + IF unit + OS unit)
3
Ambient temperature
0〜50℃
0〜55℃
4
Relative humidity
5
Atmosphere
Power supply
2
目
規
格
30〜85%RH (No condensation allowed)
-10~55℃ 10~95%RH(No dew accepts.)
No corrosive gas allowed
6
Vibration resistance
IEC 60068-2-6
Constant amplitude:3.5 mm(peak) Constant accelelation:9.8 m/s2(peak) Sweep:1 octave/min. 20 times in X,Y and Z directions
7
Shock resistance
IEC60068-2-27
147m/s2, 3 times in X, Y and Z directions
Noise-proof
IEC61131-2 IEC61131-6 IEC61326-3-1
Signal line : ±1kV DC power line : ±1kV Function ground line : ±1kV
8
53
項
1
Page 55
25
External dimensions
TOYOPUC-PCS
BASE5 TAR-6148 5slots
224
BASE8 TAR-6149 8slots
308
BASE12 TAR-6094 12slots 420
400
Gateway Module
100
118
25
70
178
40
100
85 BASE5 TAR-6148 5slots
224
BASE8 TAR-6149 8slots
308
120
52
BASE12 TAR-6094 12slots 420
Gateway Module
100
TOYOPUC-PCS-J S-STP (LC)
CPU-OP (MON)
BOOSTER
S-STP (E/LC)
S-OUT
SUB MON
S-IN(E)
S-STP (E)
S-IN (LC)
120
100
POWER
100mm
52
30mm
45mm
Max. 28mm
80mm
TOYOPUC-Plus Safety
16mm 16mm 16mm 1.0mm
1.6mm
1.6mm
16mm
1.6mm 97.6mm
8 mm
16mm
1.6mm 1.6mm
54
118
70
178
85
Page 56
Motion controller
Motion controller MCML/MCSSC
Motion system is best suited for multi-axis transfer and positioning Cost
Cost
Areas where works well
High speed multi-spindle assembly
Transfer Positioning Areas where works well
Feedback control High speed multi-spindle assembly Feedback control
Transfer Positioning
・Conveyor Single function ・Conveyor Single function Single function
Large scale equipment
Small scale equipment multi-spindle synchronization transfer and positioning
Large scale equipment
Small scale equipment
Single function multi-spindle synchronization transfer and positioning Item
No. of control
2
Command type
3
Control
No. of modules
8 axes/module Max. 24 (MCML/MCSSC) Max. 2 (Plus MCML/Plus MCSSC) SFC, ladder, FBD Possible to command from Plus-CPU
Position control
○
Speed control
○
Torque control
○
[Application] Workpiece transfer [Structure] X,Y example and Z 3 axes Application 1 + turning 1 axis [Application] Workpiece transfer Best suited for multi-axis [Structure] and Z 3 axes positioning X,Y control, from small to large size. + turning 1 axis Best suited for multi-axis positioning control, from small to large size. 2 Application example
Gantry loader
Gantry loader
[Application] Pallet transfer
Application example 2 [Structure] X and Y 2 axes
Motion control Max. control axes
1
Application example 1
[Application] Pallet transfer Simplified teaching makes [Structure] X even and Ywhen 2 axes setting easy eventhere is a lot of positioning information
Transfer vehicle for FMS
Simplified teaching makes setting easy even when eventhere is a lot of positioning information
Transfer vehicle for FMS
*FBD: Function Block Diagram *SFC: Sequential Function Chart
Motion system will solve the weak points of your current motions Weak point 1 Both ladder circuits and motion programs are necessary Weak point 1for motion control. Both ladder circuits and motion programs are necessary for motion control.
Weak point 2
Setting is necessary for controllers and servo Weakamps. point 2 Setting is necessary for controllers and servo amps.
Weak point 3 Numerical values are necessary for setting position. Weak point 3 Numerical values are necessary for setting position.
55
Other company PLC and motion
Other company Amplifier
Ladder circuit
Motion program Other company Amplifier
Other company PLC and motion Ladder circuit
Solution1
MCML Plus MCML MCSSC Plus MCSSC MCMLLadder circuit only Plus MCML MCSSC Plus MCSSC
Other company PLC and motion
Motion program Other company Amplifier
Other company PLC and motion
Other company Amplifier
MCML Plus MCML MCSSC Plus MCSSC
Other company PLC and motion
Other company Amplifier
MCML Plus MCML MCSSC Plus MCSSC
MCMLLadder circuit only Plus MCML MCSSC Plus MCSSC
1253.5 setup MCML Other company Position Otherdata company Plus MCML PLC and motion Amplifier
MCSSC Plus MCSSC
Position data 1253.5 setup
Easy designing
Motion control can be realized just by using control circuits. Simpler PLC circuits due to an introduction of the function blocks. Motion control circuits using SFC allows movement of designing Solution1 equipment to beEasy expressed simpler and easier to-understand. Also, the movement can be changed with ease. Motion control can be realized just by using control circuits. Simpler PLC circuits due to an introduction of the function blocks. Motion control circuits using SFC allows movement of equipment to be expressed simpler and easier to-understand. Also, the movement be changed with ease. Easycan setup
Solution2
All setup can be carried out on an operation panel (or peripheral tools). No need to switch computer specialty application tools or cables.
Solution2
Easy setup
All setup can be carried out on an operation panel (or peripheral tools). No need to switch computer specialty application tools or cables.
Solution3
Capture
Capture
Easy teaching
Thanks to the easy teaching function, just operate and press the read button. Current location can be easily set to a target location in one go.
Solution3
Easy teaching
Thanks to the easy teaching function, just operate and press the read button. Current location can be easily set to a target location in one go.
Page 57
Realizes motion control only using ladder circuits. In addition to this feature, being able to control with SFC and FBD allows you to design more easily. PLC
Setting up controller in link parameters
MCML/Plus MCML/MCSSC/Plus MCSSC MCML Plus MCML MCSSC Plus MCSSC
PLC
Instructs movement in SFC (ladder)
Position
Parameter
Order of movement can be seen at a glance circuit in question
Condition un-match can be known
Number Command place Feed speed POS1 PCOM 0043107 FEED 0040000 ・ ・ ・
Position setting Positioning FB
POS1 movement
Data held by the controller
POS1 POS2 movement Command sending Positioning completion
・At a glance where the equipment stops ・You can locate a cause of trouble on a screen with ease
Function block for MCML control reduces design processes
Step execution complete flag (Select one of these)
When the equipment stops
No personal computers are necessary for setting up systems. Easy setup from operation panel. It is easy to set up motion from operation panel. Operation panel
Manual pulse*1 generator
Servo amplifier
MCML Plus MCML MCSSC Plus MCSSC
Servo motor *1 MCML and MCSSC require [high speed counter] or [CT10].
It is easy to monitor motors; teaching of target position setting is also easily carried out through operation panel screens. By operating in JOG mode or with a manual pulse generator, teaching can be done in one go. Reading and modification of positioning information is possible
Move position with JOG operation from the operation panel It is possible to read current value information with the "read" button
Functions No. of control axes Control mode Encoder method Positioning control
Position command
Speed command Acceleration / deceleration setting Setup data
Positioning method No. of points Position command unit Command setting unit
Linear axis position command range
Speed command unit Speed command range Acceleration / deceleration processing Acceleration / deceleration setting range Positioning control Position output Control mode
Stroke Method Speed Compensation function Others
Communication
Supported PLC Motion setting tool
MCML
Plus MCML
MCSSC Plus MCSSC 1-8 axes Positioning control Speed control Torque control Absolute type PTP control (each axis independent movement) 700 points / axis, max. 5600 points (700x8 axes) mm, deg Can be set up by parameters from decimal 0 to 5 digits -2147483647 ~ 2147483647 -214748364. 7 ~ 214748364. 7 -21474836. 47 ~ 21474836. 47 -2147483. 647 ~ 2147483. 647 -214748. 3647 ~ 214748. 3647 -21474. 83647 ~ 21474. 83647 mm/s, mm/min, deg/s, deg/min mm/s, deg/s 0 ~ 2091752000 Trapezoid acceleration / deceleration (setting can be made per acceleration/deceleration. 2-step changeable) 1 ~ 65535 Setting data (700 points/axis) position output data (16 points/axis) Parameter (for controller and servo amplifier) 65536 rotations MECHATROLINK-Ⅲ* SSCNETⅢ* 100Mbps 50Mbps Index position compensation function Unlimited long rotation function (endless operation function) / Jog feed function / Current restraint function TOYOPUC-PC10G, PC10P, TOYOPUC-PC10G, PC10P, PC3JX・PC3JX-D, PC3J, TOYOPUC-Plus CPU PC3JX・PC3JX-D, PC3J, TOYOPUC-Plus CPU PC3JL, PC3JD, PC3JG PC3JL, PC3JD, PC3JG Motion Tool
*MECHATROLINK is a registered trademark of MECHATROLINK Association. *SSCNET is a registered trademark of Mitsubishi Electric Corporation.
56
Page 58
Device list TOYOPUC-PC10G/PC3J Device
Name
PC10G
PC10G-CPU
PC10P
PC10P
Specification Memory 180K words (60K×3), FL-net/Ethernet*/FL remote (selected by a parameter) 2port, SN-1/F/PC-LINK/CMP-LINK (selected by a parameter) built-in 1port, peripheral port available for USB2.0 Memory 180K words (60K word x3), PCI bus, USB port for a peripheral device (PCwin) communication USB port for TOYOPUC BUS-EXP (EXPANSION BUS) communication, FL-net/Ethernet*/FL remote 2 ports
FL remote I/O board FL remote I/O board Dedicated PC10P expansion module PC3JX
PC3J CPU module
FL remote I/O PNP Input/output 40/40
Connecter terminal block
TCC-6353
○
○
TCC-6372
○
○
TCU-6421
○
○
One set: 1 unit for input 50 pins and 1 unit for output 60 pins
TRS-5104
USB port for PC10P communication
SN-I/F, PC-LINK, CMP-LINK 1 port
TCU-6367
○
○
PlusBUS-EX
Special expansion module for PC10P. Supports use of Plus series options
TCU-6900
○
○
*
PC3JX-CPU
Memory: 48K words (16K words×3) PC/CMP/SN-IF/MODBUS/SIO(2 ports)
TCC-6901
○
○
PC3JX-D-CPU
Memory: 48K words (16K words×3) PC/CMP/SN-IF/MODBUS/SIO(2 ports) DeviceNet* (1 port)
TCC-6902
○
○
PC3J-CPU
Memory 48K-word(16K×3)+PC/CMP, 3 programs available
TIC-5339
○
CPU built-in option PC-link or CMP-link is available
TIU-5366
Memory 48K-word(16K×3)+PC/CMP(2port), 3 programs available
TIC-5783
○
TIC-6088
○
○
*
TIC-6125
○
○
*
Option
PC3J-CPU PC/CMP
PC3JL-CPU
Memory 180K-word(60K×3) Input(-) common32points (5mA),output(+) common16points (0.3A)+output(+) common16points (0.05A), SN-I/F, PC, CMP(1port), DLNK-M2 function Memory 48K-word(16K×3) Input(+) common32points (5mA),output(-) common16points (0.3A)+output(-) common16points (0.05A), SN-I/F, PC, CMP(1port), DLNK-M2 function
PC3JG-P-CPU PC3JG-CPU
Selector module
CSA/UL CE
BUS-EXP (EXPANDED BUS)
PC3JG
Power module
Type
* * *
POWER1
Input 85-264VAC, Output 5VDC 4A
THV-2747
POWER2H
Input DC24V Output DC5V 5A
THV-6374
○
○
SELECTOR
For setting of rack No. and I/O address
THU-2765
○
○
For mounting CPU or selector,
Base
Selector base
I/O cable
8 slot base
8 miseellaneous modules, 1 I/O connector
THR-2766
○
○
8 slot base (2)
8 miseellaneous modules, 2 I/O connectors
THR-2872
○
○
6 slot base
6 miseellaneous modules, 1 I/O connector
THR-2813
○
○
4 slot base
4 miseellaneous modules, 1 I/O connector
THR-2775
○
○
2 slot base
2 miseellaneous modules, 1 I/O connector
THR-2814
○
○
8-slot selector base
Base only for 8-slot expansion with built-in selector function, 2 I/O connectors
THR-5643
○
○
6-slot selector base
Base only for 6-slot expansion with built-in selector function, 2 I/O connectors
THR-5644
○
○
4-slot selector base
Base only for 4-slot expansion with built-in selector function, 2 I/O connectors
THR-5645
○
○
I/O cable 0.5m
For connection between a CPU base or I/O base and another I/O base:0.5m
THY-2770
○
I/O cable 1m
For connection between a CPU base or I/O base and another I/O base:1m
THY-2771
○
I/O cable 1.5m
For connection between a CPU base or I/O base and another I/O base:1.5m
THY-5146
○
*
I/O cable 2m
For connection between a CPU base or I/O base and another I/O base:2m
THY-5045
○
*
I/O cable 2.5m
For connection between a CPU base or I/O base and another I/O base:2.5m
THY-5689
○
*
I/O cable 3m
For connection between a CPU base or I/O base and another I/O base:3m
THY-2995
○
*
For connection of 3 or more beses
THU-2774
○
100VAC input, 16 points
THK-2749
I/O branch module IN-11 Input
Input/Output module Output
Input/Output
Flat cable for I/O-329G
Unit for I/O-329
IN-12
24VDC input, 16 points
THK-2750
○
○
IN-22D
24VDC input, 32 points
THK-2871
○
○
IN-22H
24VDC input, 32 points, high speed input, free screw terminal stand
THK-6831
○
○
IN-SW
Switch input, 16 points
THK-5977
○
○
OUT-1
Triac output 8 points, 1A/points, 4A/8 points, 100-115VAC
THK-2751
OUT-3
Independent relay contact 8 points (240VAC/24VDC), 2A/point
THK-2931
OUT-11
Triac output 16 points, 0.5A/point, 2A/8 point, 100-115VAC
THK-2795
OUT-12
Relay contact output 16 points, 2A/point, 5A/8 points (240VAC/24VDC)
THK-2752
○
OUT-15
MOS FET output (-) common, 16 points, 1A/point, 4A/8 points
THK-2790
○
○ ○ ○
OUT-16
MOS FET output (+) common, 16 points, 1A/point, 4A/8 points
THK-2791
○
○
OUT-18
Transister output (-) common, 16 points, 0.5A/point, 2A/8 points
THK-2753
○
○
OUT-19
Transister output (+) common, 16 points, 0.5A/point, 2A/8 points
THK-2754
○
○
OUT-28D
Transister output (-) common, 32 points, 0.2A/point, 2A/16 points
THK-2870
○
○ ○
OUT-29D
Transister output (+) common, 32 points, 0.2A/point, 2A/16 points
THK-5025
○
I/O-328G
Input 32 points (5mA), Output 16 points (0.3A) + Output 16 points (0.05A) (-) common
THK-6905
○
○
I/O-329G
Input 32 points (5mA), Output 16 points (0.3A) + Output 16 points (0.05A) (+) common
THK-6410
○
○
IO 2 - 004M
Flat cable 0.4m
TXY-6573
○
*
IO 2 - 010M
Flat cable 1.0m
TXY-6576
○
*
IO 2 - 016M
Flat cable 1.6m
TXY-6579
○
*
IO 2 - 022M
Flat cable 2.2m
TXY-6583
○
*
IO 2 - 030M
Flat cable 3.0m
TXY-6587
○
*
Connector conversion unit
40P flat cable → conversion of non-screw terminal block
TXU-6086
*
*Produced on special order ● Products circled in the CSA/UL column are qualified products by CSA.
Products marked "UL" are qualified products by UL.
● ○ Marked at CE column are CE approved products. ● *Marked at the column are oder-made products.
57
Please ask detail delivery when you order.
Page 59
Device
Name
Communication module
Specification
Type
Multi-link
ML10
Supports PC/CMP (Supports 2-wire and 4-wire), M-NET, SIO and MODBUS*
TCU-6903
○
High-speed PC link
HPC-LINK
625kbps, 32 station, 2,048 points, 1,792 bytes
THU-2758
○
2PORT FL/ET/RMT
2PORT-EFR
FL-net/Ethernet/FL remote (2port)
THU-6404
○
○
FL-net Ethernet
FL/ET-T-V2H
FL-net (version2), Ethernet interface
THU-6289
○
○
Highspeed remote I/O
Master
RMT-I/O M
Master station, 625kbps Max. 31 satellites
THU-2756
○
Satellite
RMT-I/O S
Satellite
THU-2757
○
DLNK-M2
Master station, 500/250/125kbps, 63 stations, 4,096 points
THU-6099
○
○
DLNK-S
Satellite, I/O terminal type, 500/250/125kbps, 512 points
THU-5441
○
○
DLNK-S2
Satellite, between-PC link type, 500/250/125 kbps, input and output 512 points respectively
THU-5563
○
○
SC10
RS-232C,
TCU-6904
○
○
CT10
200kpps (PC input) 8Mpps (differential input)
AD-10
−10〜10V, 0〜10V, 0〜5V,1〜5V, 0〜20mA, 4〜20mA
TCK-6529
○
○
Analogue output
DA-1
1−5V, 4−20mA 2 points
THK-7931
○
○
DA-2
0−10V 2 points
THK-7932
○
○
PULSE output
PULSE OUT
Pulse output 1-axis easy positioning
THK-5109
Motion controller
MCML
Max. 8-axis positioning, MECHATROLINK-Ⅲ*
TCI-6721
○
○
MCSSC
Max. 8-axis positioning, SSCNETⅢ*
TCI-6805
○
○
DeviceNet*
Serial I/O High-speed counter Analogue input Special module
0.3〜115.2kbps,
2ch
CSA/UL CE
*
○
TCK-6856 8 points
*
*Produced on special order
Parts Device
Name
Lithium battery Connector
Specification
Type
For PC10/PC3J-CPU
For TOYOPUC-PC10/PC3J/MX/PCS/PCS-J CPU, Coin-type secondary cell
T I P-5426
For CPU
For TOYOPUC-PC2/PC2J/L2 CPU, PC2FS
TXP-2789
External connector for PC3JG and I/O-329G
A 40-pin square shape connector of soldering type (with a 40-pin resin enclosure)
T I P-5867
CSA/UL CE
*
CSA/UL CE
*
TOYOPUC-PCk Device
Name
TKC-6471
UL
○
PCk06-P-CPU
Program capacity 7,679 words Input: Built-in 20 points Output: Built-in 16 points (source output)
TKC-6472
UL
○
Input
Communication module
Type
PCk05-CPU CPU
Input/output module
Specification Program capacity 2,048 words Input: Built-in 8 points Output: Built-in 6 points (relay output)
IN-k93
Input (10 points, DC12-24V)
TKK-6473
UL
○
IN-k14
Input (16 points, DC20-28V)
TKK-6474
UL
○ ○
OUT-k12
Output (16 points, DC12-24V, source)
TKK-6475
UL
OUT-k81
Relay output (8 points, DC6-27V, AC6-240V)
TKK-6478
UL
○
Input-output
I/O-k831
Input-output (input 4 points DC12-24V, relay output 3 point )
TKK-6476
UL
○
Device net Slave kDLNK
Device net Slave
TKU-6477
Connector with a cable for a 16-point modules 1m
TKY-6486
Output
Connector with a cable
TOYOPUC-PC3JT Device
Name PC3JT-CPU
CPU
Communication
Input/Output module FL-net, Ethernet
Specification
Type
CSA/UL CE
Memory 48K-word(16K×3), CX/CMP link and PC/CMP link built-in
TIC-5994
○
Option
DLNK
Master station, 500/250/125kbps, 63 stations, 2,048 points
TIU-5996
○
Option
AS-i M
AS-i I/F
TIU-6026
○
PC3JT-I/O(+)
16 points DC24V input 16 points MOS-FET output(+) common,0.1A/point, 1A/16 points
TIU-6212
○
PC3JT-I/O(-)
16 points DC24V input 16 points MOS-FET output(-) common,0.1A/point, 1A/16 points
TIU-6213
○
PC3JT-FL/ET-V2
FL-net I/F, Ethernet I/F
TIU-6021
○
High-speed PC link High-speed remote I/O
PC3JT-HPC
PC link : 625 kbps, 32 stations, 2048 points, 1792 bytes, 1 : N communication. Remote I/O : Master station 625kbps, 2048 points, selection of max. 31satellites, built in 2 port
TIU-6022
○
S-LINK
*
PC3JT-S-LINK
S-LINK interface made by Sunx
TIU-6025
○
Special Serial I/O
PC3JT-SIO
RS-232C, 0.3−19.2Kbps, 2ch
TIU-6024
○
Cover
PC3JT cover
The cover for PC3JT
TIU-6027
Base
PC3JT base2
The base for PC3JT
TIU-6146
*
*DeviceNet is a registered trademark of Open DeviceNet Vendor Association Inc. *AS-i is an open network of AS-international (AS-i association). *MECHATROLINK is a registered trademark of MECHATROLINK Association. *SSCNET is a registered trademark of Mitsubishi Electric Corporation. *Ethernet is a registered trademark of Fuji Xerox. *MODBUS is a registered trademark of AEG Schneider Automation Inc.
58
Page 60
Device list PCDL Device
Name
CPU
PCDL
AC power supply base Base module DC power supply base
DC input Input/ Output module
DC output
AC output
Analogue module
Programmer
Type
CSA/UL
CE
TKC-6688
UL
○
D2-03B-1J
2 module base (AC power supply)
TKR-6689
UL
○
D2-04B-1J
3 module base (AC power supply)
TKR-6690
UL
○
D2-06B-1J
5 module base (AC power supply)
TKR-6691
UL
○
D2-09B-1J
8 module base (AC power supply)
TKR-6692
UL
○
D2-03BDC1-1J
2 module base (DC power supply)
TKR-6693
UL
○
D2-04BDC1-1J
3 module base (DC power supply)
TKR-6694
UL
○
D2-06BDC1-1J
5 module base (DC power supply)
TKR-6695
UL
○
D2-09BDC1-1J
8 module base (DC power supply)
TKR-6696
UL
○
D2-08ND3
8 points DC12/24V (+/-)common
TKK-6697
UL
○
D2-16ND3-3J
16 points DC24V (+/-)common
TKK-6698
UL
○
D2-32ND3
32points DC24V (+/-)common (connector type)
TKK-6718
UL
○
D2-08TD2
8 points Open collector output DC12/24V (+) common
TKK-6699
UL
○
UL
D2-16TD2-3J
16 points Open collector output DC12/24V (+) common
TKK-6700
D2-32TD2
32 points Open collector output DC12/24V (+) common (connector type)
TKK-6719
*
○ ○
D2-08TA
8 points SSR output AC100V/200V
TKK-6701
UL
○
Analogue input
Current input
F2-08AD-1
8ch/common, 4~20mA
TKK-6705
UL
○
Voltage input
F2-08AD-2
8ch/common, 0~5V/0~10V/±5V/±10V
TKK-6706
UL
○
Analogue output
Current output
F2-08DA-1
8ch, single end, 4-20mA
TKK-6707
UL
○
Voltage output
F2-08DA-2
8ch, single end, 0-5V/0-10V
TKK-6708
UL
○
D2-02RM
M-NET specifications (8 stations, 256 points)
TKU-6728
UL
○
Communication M-NET module CUnet Other modules
Specification Memory 16K words Built-in communication (Slave) I/F:RS232C(PCwin)/MODBUS*-RTU L1:FL-net * L2 : CMP-LINK/MODBUS -RTU (Slave) / Serial I/O(SIO) /PC-LINK/SN-I/F
D2-HSIO
CUnet specifications(64 stations, 4096 points)
TKU-6832
Expansion controller
D2-CM
Mounted on a base module CPU slot.
TKU-6702
UL
○
Expansion controller
D2-EM
Mounted at the right side of a base module.
TKU-6703
UL
○
Dummy panel
D2-FILL
Covering for empty slots
TKU-6704
Programming tool
PCwin (Ver.12 or more)
PC10/3/2/1 series・MX・PCDL Programmer
TJA-2032
Connecting cable
PCk connecting cable
D-SUB 9P⇔RJ12 conversion connector and RJ12⇔RJ12 Programmer connecting cable (2m) set
TKY-6485
Specification
Type
16K/48K words, Ethernet* / FL-net / FL Remote (selected by a parameter) 1port, PC/CMP/SIO/MODBUS* 1port, peripheral port available for USB2.0
TCC-6740
○
○
TCU-6741
○
○
TCU-6858
○
○
○
○
○
○
TOYOPUC-Plus Device CPU
Name Plus CPU
CSA/UL CE
Plus expansion mode (enabled when EX board is implemented) Ethernet* / FL-net / FL Remote 10Mbps / 100Mbps, EtherCAT* 100Mbps
Plus EX
PC / CMP / SIO (RS422 / RS232C) / SN- I / F / MODBUS* Additional functions
Plus expansion mode (enabled when EX2 board is implemented) Ethernet* / FL-net/FL Remote / EtherNetIP 10Mbps/100Mbps, EtherCAT* 100Mbps
Plus EX2
PC/CMP/SIO (RS422/RS232C) /SN-I/F/MODBUS
*
Communication
Motion
Input/output
Plus EFR
Etherne*t / FL-net / FL Remote 10Mbps / 100Mbps, EtherCAT* 100Mbps
TCU-6743
Plus EFR2
Ethernet* / FL-net/FL Remote / EtherNetIP 10Mbps/100Mbps, EtherCAT* 100Mbps
TCU-6859
Plus DLNK-M
DeviceNet master
TCU-6744
Plus CLNK-M
CC Link* master Ver 2.00 compatible
TCU-6824
Plus CLNK-S
CC Link* slave Ver 2.00 compatible
TCU-6830
○
○
Plus MCML
Positioning / torque / speed control max. 8-axis MECHATROLINK-III*
TCI-6819
○
○
Plus MCSSC
Positioning / torque / speed control max. 8-axis SSCNETⅢ*
TCI-6884 ○
○
*
24 inputs (5mA/24V, (-) common)
Plus IO24/16P
16 outputs (0.5A/24V, (+) common)
Cover
Plus cover
Cover for Plus
Bracket
BRA-DIN
Bracket mounting the DIN rail for Plus
● Products circled in the CSA/UL column are qualified products by CSA.
Products marked "UL" are qualified products by UL.
● ○ Marked at CE column are CE approved products. ● *Marked at the column are oder-made products.
59
Please ask detail delivery when you order.
TCU-6742 TCU-6779
*