Spec sheet · Traco Power
Industrial Power Supplies TIS Series, 50–600 Watt
Spec sheet12 pagesPDF 1.1 MB
Data sheet for the Traco Power TIS series DIN rail switch mode power supplies, 50 to 600 W, including the TIS 75-124 and TIS 150-124.
Covers · 2 models
The models it covers
Summary
What is in it
Traco Power's data sheet for the TIS series of industrial switch mode power supplies for DIN rail mounting, 50 to 600 W, with 12, 24, 48 and 72 VDC outputs. It lists every model with input voltage, output power, voltage and current (including the TIS 75-124 and TIS 150-124), then gives input and output specifications, regulation, ripple, protection, hold-up times, approvals and the optional redundancy, signal and DC-UPS function modules.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A Traco Power specification sheet for the TIS series of DIN-rail industrial power supplies, 50 to 600 W, among them the TIS 75-124 and TIS 150-124. It gives input, output and general specifications, the redundancy (RED), powerfail (SIG) and DC-UPS (UDS) option models, case dimensions and mounting kits. It lets the reader choose a model and check its ratings, wiring and mounting.
- Device type
- Switch mode power supply for DIN-rail mount, TIS series p. 1
- Input voltage
- Selectable 115/230 VAC input; input frequency 47 – 63 Hz p. 1, 2
- Operating temperature
- –25°C to +70°C ambient, derating 2 %/K above 50°C (122°F) p. 3
- Ripple and noise
- <50 mV pk-pk (20MHz bandwidth) p. 2
- Protection
- Short circuit: current limitation at 110 % typ., automatic restart; overvoltage trigger at 140 % typ. Vout nom. p. 2
- Efficiency
- TIS 50 ... TIS 300: 85 % typ. p. 3
- TIS 150-124 output
- TIS 150-124: 24 VDC / 6 A; weight 0.80 kg (1.76 lb) p. 8
- Switching frequency
- 80 kHz typ. (pulse width modulation) p. 3
- Input current
- Full load at 115 VAC (typ.): TIS 75: 1.3 A; TIS 150: 2.7 A p. 2
- Load regulation
- TIS 75 and TIS 150: 1.0 % (10–90% load); input variation 0.2 % p. 2
- Hold-up time
- TIS 50 ... TIS 300: min. 25 ms at 115 VAC, min. 30 ms at 230 VAC p. 2
- Mounting and terminals
- Snap-on for 35 mm DIN-rails (EN 50022); detachable screw terminal block, plugs included p. 3
- Connector sets
- TIS PLUG-1 for TIS 50/ 75/ 150; TIS PLUG-1-RED for TIS 150-1xx RED p. 8
- TIS 150 option models
- TIS 150-124 RED (redundancy, up to 5 units in parallel) and TIS 150-124 SIG (AC-powerfail, power good, remote on/off) p. 4, 5
What this sheet walks you through
- Choosing a TIS model by input, output power, voltage and current p. 1
- Building N+1 redundant systems with the RED option p. 4
- Using the AC-powerfail and power good relays and remote on/off p. 5
- Setting up a DC-UPS with external batteries p. 6, 7
- Case dimensions and weights p. 8, 9, 10
- Wall and rugged DIN-rail mounting kits p. 11
Good to know
- The RED redundancy option cannot be combined with other options and is offered for 150 W, 300 W and 600 W models. p. 4
- On UDS models the battery should be fitted with a fast blow fuse. p. 6
- On UDS models, reduce the maximum output current by the battery charging current. p. 6
- Specifications hold at nominal input voltage, full load and +25 °C after warm-up unless stated otherwise. p. 3
- Relay contacts of the RED option are rated 60 VDC / 0.36 A max. p. 4
Questions this sheet answers
What input does the TIS 150-124 take?
Its label drawing shows a 115/230 VAC, 50/60Hz input; the series has a selectable 115/230 VAC input. p. 1, 8
What is the output of the TIS 150-124?
24 VDC at 6 A. p. 8
How does a TIS power supply mount?
It snaps onto 35 mm DIN-rails; wall mounting kits are offered as options. p. 3, 11
Can TIS 150 power supplies run in parallel for redundancy?
Yes, the RED version allows parallel operation of up to 5 units with active current sharing. p. 4
What is the operating temperature of the TIS series?
–25°C to +70°C ambient, with 2 %/K derating above 50°C. p. 3